• 제목/요약/키워드: Contact diameter

검색결과 491건 처리시간 0.028초

주철의 표면로울링에서 이송량과 로울링 회수에 따른 변화 연구 (Effects of Rolling Numbers and Feeds on Surface Deformation in Surface Rolling of Cast Iron)

  • 육굉수;이용철;곽수헌
    • 한국정밀공학회지
    • /
    • 제6권3호
    • /
    • pp.68-77
    • /
    • 1989
  • The surface rolling for cylindrical surface of a grey cast iron was carried out using a lathe with a simple newly-designed tool system. A surface rolling tool used was steel ball whose diameter was 3/8 inch (9.525mm) The effects of rolling feeds and number of rolling on surface rolling were investigated. The contact pressure between ball and workpiece which was considered as Hertz's contact problem was examined and the track of motion of a ball on the cylindrical surface of a work- piece was measured according to the rolling feed. The results obtained were as follows; 1. The roughness of the machined surface which was originally 5.3 .approx. 28 umRz decreased to 1.2 .approx. 5 umRz according to rolling feeds and numbers of rolling. 2. The hardness increased from Hv 260 to Hv 290 .approx. 310 through 2 .approx. 4 rollings according to the roughness of machined surfaces. 3. The reduction of diameter was found to be proportional to the variations of roughness of previous machined surfaces. About 60% to 90% of reduction in diameter was made during the first rolling process. 4. An equation relating the reduction of diameter and the variation of surface roughness after surface rolling was presented using a geometric surface model. 5. An equation for the calculation of dynamic contact area between pressure ball and workpiece according to the rolling feed was presented.

  • PDF

소프트콘택트렌즈 피팅과 관련된 가시홍채직경 및 검열크기에 대한 상관관계 (A Relationship Between Visible Iris Diameter and Palpebral Aperture Size : Considered to Solve Uncomfortable Feeling of Soft Contact Lens)

  • 이정윤;육도진;이지영
    • 한국안광학회지
    • /
    • 제19권3호
    • /
    • pp.285-293
    • /
    • 2014
  • 목적: 초등학생에서 일반인을 대상으로 가시홍채직경(수평, 수직) 및 검열의 폭과 길이를 측정하여 이들의 상관관계 및 소프트콘택트렌즈 크기의 연령별 적합성을 알아보고자 하였다. 방법: 안질환이 없고 외형적으로 미용을 포함한 눈 수술을 하지 않은 초등학생에서 일반인 총 514명(1028안)을 대상으로 가시홍채직경(수평, 수직)과 검열의 폭과 길이를 측정하고 분석하였다. 결과: 가시홍채수평직경과 수직직경은 연령별 남녀 간의 유의한 차이는 없었으나, 중학생과 대학생의 검열의 길이와 고등학생의 검열의 폭은 남학생과 여학생 간 유의한 차이가 있었다(p<0.05). 또한, 남녀 모두 가시홍채수평직경, 가시홍채수직직경, 검열의 길이 그리고 검열의 폭에서 연령별로 유의한 차이를 보였다. 가시홍채직경과 검열의 크기는 문헌에 기준한 정상범위 근사치보다 검열의 폭은 남녀를 포함한 전체 대상자의 27.9%, 가시홍채직경은 36.0%가 작은 것으로 나타났다. 결론: 가시홍채직경과 검열의 크기는 소프트콘택트렌즈의 직경 결정에 영향을 미치며, 특히 렌즈 삽입시 피검자의 불편함을 덜어주기 위해서 좀 더 세심하게 고려되어야 할 사항이라고 사료된다.

압연기용 Roll의 동견부(Chamfer=Barrel Edge)에서의 음력집중의 완화 대책 (Analysis on contact stress concentration at the end of strip mill rolls)

  • 소야신시
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 제7회 압연 심포지엄
    • /
    • pp.13-16
    • /
    • 2009
  • In order to investigate the effects of geometry factors such as a roil diameter ratio and backup roll crown of the stress concentration factor on the edge of backup roil end, 3-dimensional FEM analyses of stress at the contact of backup roll and work roll assembled in a 4-high strip mill were carried out, It was made clear that the peak stress at the edge is about 2 to 3 times of that at the longitudinal center of the roll barrel and the peak stress proportionally increase with decreasing the ratio of backup roll diameter to work roll diameter Furthermore a crowning on the backup roll is effective to decrease the maximum edge stress.

  • PDF

LVDT 센서를 이용한 외경 측정 방안에 대한 연구 (A Study on the out-diameter measuring machine by the LVDT sensors)

  • 황정호;노지훈;박기홍
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.291-292
    • /
    • 2006
  • Currently A demand of high precision workpiece is increasing in industry. At present, roundness measuring machine using Air bearing, coordinate measuring machine that are used from measurement station. but these machines will not be able to apply to In-line process. because of like these machine's price are very expensive and measurement time is long. also, the complexity of conventional roundness measurement method based on fourier transform, it makes difficult to development analysis program. This work present new architecture of a Out-diameter measuring system fur analysis of roundness of product. In this system, the influence of table motion errors is minimize by using two LVDT sensor and knife edge contact tip. We are produce a test machine and make an experimenter on Out-diameter of test bearing. The measurement result compared with roundness measuring machine.

  • PDF

임플란트 직경이 골유착에 미치는 영향에 관한 연구 (INFLUENCE OF IMPLANT DIAMETER ON THE OSSEOINTEGRATION OF IMPLANTS : AN EXPERIMENTAL STUDY IN RABBITS)

  • 이준호;신상완;권상호
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.169-181
    • /
    • 2003
  • Statement of problem : The survival rate of wide diameter implants was lower than of 3.75-mm implants in some clinical researches. Purpose : The purpose of this study was to investigate the influence of implant diameter on the osseointegration of implants in the rabbit femoral condyle and tibial metaphyses by means of removal torque measurements and histomorphometric analysis. Material and Method : Ten adult New Zealand White rabbits were used in this study Two 3.75-mm diameter implants were inserted through one cortical layer in the tibial metaphyses and one 3.75-mm diameter implant was inserted in the femoral condyle. 5.0-mm diameter implants were inserted in the other leg in the same manner. A total of 60 implants (3.75-mm diameter implants:30 : 5.0-mm diameter implants:30) were installed. After a healing time of 4 and 12 weeks, the peak removal torque values required to shear off the implants were recorded. From the removal torque values (Ncm) obtained, the mean shear stress ($N/mm^2$) was calculated. And the percentage of direct bone-to-implant contact and the percentage of bone area inside the thread were measured by Kappa Image Base-metreo. The Student's t-test was undertaken for statistical analysis (p<0.05). Results : The removal torque value of 5.0-mm diameter implants was higher than of 3.75-mm diameter implants (p<0.05). The difference of shear stress value between 3.75-mm and 5.0-mm diameter implants was not statistically significant (p>0.05). The percentage direct bone-to-implant contact had no statistical difference between two groups (p>0.05). The percentage of bone area inside the thread had no statistical difference between two groups (p>0.05). Conclusion It is concluded that the quality f osseointegration is not influenced by increasing implant diameter.

Effect of Different Conditions of Sodium Chloride Treatment on the Characteristics of Kenaf Fiber Bundles

  • Tamaryska, SETYAYUNITA;Ragil, WIDYORINI;Sri Nugroho, MARSOEM;Denny, IRAWATI
    • Journal of the Korean Wood Science and Technology
    • /
    • 제50권6호
    • /
    • pp.392-403
    • /
    • 2022
  • Currently, composite board manufacturing using natural fibers has the potential to expand owing to environmental awareness. To produce a composite board, treatment is required to improve the mechanical and physical properties of the natural fibers. In this study, sodium chloride (NaCl) was used for the chemical treatment. However, studies on chemical treatments using NaCl are limited. This study aimed to investigate the characteristics of kenaf fibers after NaCl treatment. The NaCl treatment concentrations were 1, 3, and 5 wt.% at room temperature, with soaking durations of 1, 2, and 3 h. The tensile strength, strain, and Young's modulus were measured to evaluate the mechanical properties of the fibers. The fiber bundle diameter, weight change owing to treatment, and contact angle were determined to analyze the effect of NaCl treatment. The kenaf fiber bundle treated with 5 wt.% NaCl for 3 h exhibited the highest tensile strength, Young's modulus, reduction in fiber bundle diameter, weight change, and decrease in contact angle compared to those of untreated fiber bundles. The tensile properties of the fiber bundle exhibited a tendency to decrease with increasing fiber bundle diameter. Increasing the soaking duration from 1 to 2 h did not result in a significant decrease in the fiber bundle diameter or an increase in tensile strength. However, a further increase in the soaking duration from 2 to 3 h resulted in a considerable decrease in the fiber bundle diameter and an increase in the tensile strength.

구강병소에 대한 펄스형 Nd: YAG 레이저의 치료효과 (The Therapeutic Effects of a Pulsed Nd:YAG Laser on Oral Lesions)

  • 신금백
    • Journal of Oral Medicine and Pain
    • /
    • 제22권2호
    • /
    • pp.309-325
    • /
    • 1997
  • In order to set the lasing variables and evaluate, clinically, the therapeutic effects of a pulsed Nd:YAG laser on oral lesion, the author applied the laser energy from a fiberoptic delivered, free running, pulsed Nd:YAG laser (wavelength 1064nm, Pulse duration 120$\mu$sec, fiber diameter 200$\mu$m/320$\mu$m) to 22 cases of oral soft tissue lesions and 6 cases of oral hard tissue lesions. The obtained results were as follows : 1. The effective excision with contact mode and the effective hemostasis of accompanied bleeding with noncontact mode were occurred by lasing on oral soft tissue lesions with fiber diameter of 320$\mu$m under the variables of 2.0~4.0W and 20~50Hz which were controlled into high power/low pulses for excision, low power/high pulses for hemostasis, low power in granulation tissue and high power in fibrous tissue according to therapeutic goals and tissue conditions. 2. About 50% of decreasing effect on hypersensitivity was occurred by lasing with non-contact and contact mode on cervical abrasion which caused dentinal hypersensitivity with fiber diameter of 320$\mu$m under the variables of 0.7 - 1.0W and 10Hz which were applied 2~3 times with 1 week interval. 3. The effective sterilization of infected root canal and lesion of periapical abscess was occurred by lasing with contact and spiral modes on wall of root canal and periapical abscess with fiber diameter of 200$\mu$m of which the tip was placed about 1mm shorter than root canal length under the variables of 1.OW and 10Hz.

  • PDF

아이라이너 침착에 의한 소프트 콘택트렌즈 파라미터의 변화 및 세척효과의 비교 (Comparisons of the Change in Soft Contact Lenses Parameters and the Cleaning Efficiency after Eyeliner Deposition)

  • 박미정;김사현;구보경;김소라
    • 한국안광학회지
    • /
    • 제18권2호
    • /
    • pp.107-115
    • /
    • 2013
  • 목적: 본 연구에서는 눈 화장품인 아이라이너에 노출시킨 소프트 콘택트렌즈의 파라미터가 어떻게 변하는가를 알아보고, 세척방법을 달리하여 세척하였을 때의 세척효과와 렌즈 파라미터의 회복정도를 비교하고자 하였다. 방법: 서로 다른 재질로 제조된 3종류의 소프트 콘택트렌즈에 각각 1시간, 4시간 및 6시간 동안 아이라이너를 침착시킨 후 안경용 초음파 세척 및 손 세척을 시행하였으며, 세척 전후 렌즈의 가시광선 투과도, 직경 및 표면의 변화를 비교하였다. 결과: 소프트 콘택트렌즈의 가시광선 투과도는 아이라이너의 침착시간이 길어질수록 감소하였다. 렌즈의 표면을 관찰한 결과 아이라이너의 침착 양상은 렌즈재질의 물성에 따라 다르게 나타나 narafilcon A 재질 렌즈에서 가장 침착이 큼을 알 수 있었다. 렌즈 직경은 hilafilcon B 및 etafilcon A 재질 렌즈는 감소하였으나, narafilcon A재질 렌즈는 증가하는 것으로 나타났다. 이러한 아이라이너의 침착은 안경용 초음파 세척기를 이용한 세척보다는 다목적 용액을 이용한 손 세척 시 세척효율이 우수한 것으로 나타났으나 렌즈의 직경이나 가시광선 투과도, 렌즈표면 등 렌즈 파라미터가 원래 상태로 회복되는 데에는 한계가 있었다. 결론: 이상의 결과로 소프트렌즈를 착용한 상태에서 눈 화장 하는 것을 최소화하는 것이 옳으며, 반복적으로 눈 화장을 할 때에는 렌즈 파라미터의 변화를 고려한 착용시간의 단축이나 빠른 렌즈의 교체주기가 필요하다고 사료된다.

Performance analysis of spherical indentation process during loading and unloading - a contact mechanics approach

  • Gandhi, V.C. Sathish;Kumaravelan, R.;Ramesh, S.
    • Structural Engineering and Mechanics
    • /
    • 제52권3호
    • /
    • pp.469-483
    • /
    • 2014
  • In an indentation approach, the smooth rigid spherical ball penetrated into a deformable flat is considered for the study based on contact mechanics approach. The elastic-plastic frictionless spherical indentation analysis has been under taken in the finite element analysis using "ABAQUS" and experimental study. The spherical indentation has been studied for the materials like steel, aluminium, copper and brass with an identical spherical indenter for diverse indentation depths. The springback analysis is executed for studying the actual indentation depth after the indenter is unloaded. In the springback simulation, the material recovers its elastic deformation after the indenter is unloaded. The residual diameter and depth of an indentation for various materials are measured and compared with simulation results. It shows a good agreement between the simulation and an experimental studies.

Line Laser 를 이용한 목재단면 측정 및 영상보정 방법 (A Method of Wood Section Measuring and the Image Calibration Using Line Laser)

  • 김기환;박민수;김도엽;이석용;이응석
    • 한국정밀공학회지
    • /
    • 제33권8호
    • /
    • pp.641-646
    • /
    • 2016
  • The best method of measuring wood diameter is a contact-type device: however, obtaining an accurate result can be problematic under certain circumstances. In this study, we used a laser beam and a CCD camera that did not require contact with wood. The wood is illuminated by the laser beam, and the CCD camera captures this illumination. The measurement results were determined by processing of the captured image sequences. This paper explains the use of image processing and laser systems for measurement of wood under circumstances in which physical contact is impossible.