• Title/Summary/Keyword: Contact Treatment

Search Result 1,611, Processing Time 0.023 seconds

Centrifuge Model Tests on Trafficability of Very Soft Ground Treated with Geotextile and Sand Mat (토목섬유와 모래로 처리된 초연약지반의 장비주행성에 대한 원심모형실험)

  • Jun, Sang-Hyun;Lee, Jong-Ho;Yoo, Nam-Jae
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.3
    • /
    • pp.13-23
    • /
    • 2010
  • In this study, centrifuge model tests with 50 g gravitational condition were performed to evaluate the bearing capacity of very soft ground, improved by spreading geotextile and sand on the surface of ground, for the heavy machinery to be able to access. For undrained shear strength of ground model, prepared with the clay sampled from the field, being in the range of 3.1~11.7 kPa, bearing capacity tests were performed with the model footing and the loading system built to simulate the heavy machinery on the ground model treated with geotextile and sand. Test results were compared with theoretically and numerically evaluated ones. Test results about load-settlement curves showed that the bearing capacity increases with the increase of the undrained shear strength of ground. Punching shear or local shear failure was also observed. For a relatively low undrained shear strength of ground, settlement behavior is found to be crucial to evaluating the trafficability of machinery whereas bearing capacity becomes a dominant factor with the increase of undrained shear strength of ground. The method for assessing the bearing capacity of the ground related to trafficability of machinery is presented by acquiring the regression relationship between the contact pressure of machinery and settlements using load-settlement curves with the change of the undrained shear strength. Furthermore, results of numerical analyses about load-settlement relation are in relatively good agreement with those of centrifuge model test.

Selection of Aerial Spraying Control Agent and Susceptibility of Pinewood Nematode Vectors to Spraying Using Unmanned Aerial Vehicles (소나무재선충 매개충에 대한 항공방제 약제 탐색 및 무인항공기 살포에 의한 매개충의 약제 감수성)

  • Junheon Kim;Sangjune Nam;Jinyoung Song
    • Korean journal of applied entomology
    • /
    • v.62 no.1
    • /
    • pp.43-48
    • /
    • 2023
  • The efficacy of spinetoram sprayed from an unmanned helicopter to control two insect vectors of pine wood nematodes, Monochamus alternatus and M. saltuarius was assessed. By using a ULV (Ultra Low Volume) sprayer, the mortality rates of phenthoate, bifenthrin, etofenprox, and diflubenzuron, which are registered for use against coleopteran insects, indoxacarb and spinetoram, which are registered for use against lepidopteran insects, were evaluated for efficacy as aerial spraying agents. The ULV test, using 33- and 55-fold dilutions of phenthoate, bifenthrin, indoxacarb, and spinetoram demonstrated a 100% insect mortality rate upon contact and feeding mortality on the third day after treatment, while etofenprox and diflubenzuron exhibited a slightly lower mortality rate than the remaining compounds. Consequently, spinetoram was selected as a candidate pesticide for aerial spraying and its efficacy to control the insect vectors was assessed. The x 33 dilution of spinetoram resulted in a 98.6-100% control efficacy against two insect vectors. However, risk assessment for bees following aerial spraying will be necessary before applying the pesticide to control insect vectors.

The Clinical Investigation of Necrotizing Fasciitis in Burn Center (화상센터에서 치료한 괴사성근막염의 임상적 고찰)

  • Kim, Euimyung;Chun, Jin Woo;Kim, Young Min;Yoon, Jae Chul;Lim, Hae Jun;Cho, Yong Suk;Kim, Dohern;Hur, Jun;Chun, Wook
    • Journal of the Korean Burn Society
    • /
    • v.22 no.2
    • /
    • pp.66-70
    • /
    • 2019
  • Purpose: The necrotizing fasciitis is a terrifying infectious disease that can rapidly spreads to surrounding tissues when fascia is infected and it can cause sepsis to death if not properly diagnosed and treated. The purpose of this study is to investigate the characteristics, causes, and treatment methods of necrotizing fasciitis in Korea through reviewing patients admitted to our burn center. Methods: 21 patients with necrotizing fasciitis were selected for this study among those inpatients with electronic medical records (EMR) admitted to Hallym University Hangang Sacred Heart Medical Center from Jan 1, 2008 to June 30, 2019. The medical records and wound photos of those 21 selected subjects were reviewed. Results: There were 13 male and 8 female patients and mean age was 58.76 years old. 13 of 21 subjects were survived and 8 died (38% mortality rate). The surgical treatments performed were I&D, fasciotomy, debridement, allograft, burring, STSG, flap, and amputation. The most common causes were burns in 9 subjects (6 contact burns) and cellulitis occurred on skins in 5 subjects. And other various causes were observed as fournier's gangrene, stab wound, intramuscular injection, tumor and bleu toe syndrome (toe necrosis). The infected areas were 11 feet and legs, 7 hips, 3 abdomen and trunk in 21 subjects. Of the 8 deaths, 3 were infected in feet and legs, 2 were infected in hips, and 2 were infected in abdomen and trunk. As for underlying diseases, 12 patients with hypertension or diabetes were the highest and others such as cancer and stroke were found. Conclusion: The only method to increase the survival rate is to 'suspect' the disease as much as possible and perform early extensive excision. It is advisable to treat the disease by the burn center to properly provide adequate and optimal wound management, infection control, medical care and nutritional supports.

Full mouth rehabilitation of a patient with excessive worn dentition by increasing vertical dimension of occlusion: a case report (과도한 치아 마모 환자에서 교합수직고경 증가를 동반한 완전구강회복 증례)

  • Jong Seok Lee;Ji Suk Shim;Jae Jun Ryu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.234-244
    • /
    • 2023
  • Tooth wear refers to the loss of dental hard tissue caused by various physiological and pathological causes, and excessive pathological wear can cause complications such as pathological changes in dimensions, occlusal disharmony, loss of function, and aesthetic problems. The cause of tooth wear can be caused by attrition, abrasion, corrosion and abfraction, and it is known to act in a multifactorial etiology in interocclusal activity. In patients with excessive pathological wear, it is important to determine whether or not the vertical dimension of occlusion is reduced, and complete oral rehabilitation should be achieved with the adaptation of the neuromuscular and temporomandibular joint through accurate diagnosis and analysis. The patient in this case was a 63-year-old male patient, who presented discomfort to cold beverage due to severe tooth wear. After analysis of the patient's vertical dimension of occlusion, a full mouth rehabilitation was performed with increasing vertical dimension of occlusion. The goal of treatment was to improve the occlusal plane with the equal-intensity contact of all teeth, harmonious anterior guidance and immediate disclusion of all posterior contacts. After rehabilitation, the patient was satisfied with function and esthetic appearance.

Efficacy of Commercial Sanitizers for the Inactivation of Listeria monocytogenes on the Processing Equipment for Enoki Mushrooms (팽이버섯 재배 현장에서 Listeria monocytogenes의 성장을 억제하기 위한 살균 처리 기술 개발)

  • Kyung Min Park;Su-Bin Lee;Do-Young Jung;Song-Yi Choi;Injun Hwang;Se-Ri Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.6
    • /
    • pp.508-516
    • /
    • 2023
  • The consumption of enoki mushrooms has been associated with cases of listeriosis produced by Listeria monocytogenes, highlighting the significance of sanitizing food-contact surface, such as the velcro used in welding processing of enoki mushrooms, to ensure microbial safety. We investigated the inhibitory activity of nine chemical disinfectants at regular concentrations against L. monocytogenes isolated from a mushroom farm environment. The bacterial suspension was prepared in phosphate buffered saline and mushroom extract broth and inoculated onto the velcro surface. After inoculation, most disinfectants reduced the initial 8 log CFU/coupon concentration by less than 2 log CFU/coupon during a 5-min treatment. Slightly acidic hypochlorous water showed a reduction of approximately 4 log CFU/coupon when tested for more than 30 min at the maximum allowable concentration of 200 mg/L. Sodium hypochlorite solution showed a reduction of approximately 5 log CFU/coupon when used at 100 mg/L for 60 min. Peracetic acid, at the maximum allowable concentration of 300 mg/L, showed the most effective reduction of 5 log CFU/coupon or more when the surface was treated with 37.5 mg/L for 30 min. These results indicate that peracetic acid can be used as the disinfectant strategy to control cross-contamination of L. monocytogenes on the velcro surface of plastic wrappers used in the welding processing of enoki mushrooms.

A Study on the Control of Hygroscopicity and Hardness in Polymer Surfaces (고분자 표면의 흡습성 및 경도 제어 연구)

  • Jinil Kim;Young Nam Jung;Doa Kim;Myung Yung Jeong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.4
    • /
    • pp.86-90
    • /
    • 2023
  • The packaging of electronic devices performs a protective function to ensure that their durability and reliability are not affected by changes in the operating environment caused by external factors. Recent advances in materials have led to ongoing research into bonded packaging of heterogeneous materials such as polymers and inorganic materials in electronic devices. In this packaging process, it is important to have a binding that joins the materials and ensures the operating environment, which includes adhesion to the substrate, corrosion and oxidation resistance through moisture removal, and durability. In this study, the hygroscopicity of the coating layer by modifying the polymer surface based on PVA was evaluated by controlling and measuring the contact angle, and the adhesion was confirmed by applying water-based ink and testing according to ASTM_D3363. For the durability of the polymer surface, the IPL post-treatment process was used to improve the hardness and toughness against applied voltage, and the pencil hardness test and nanoindentation test were conducted. Through this, we analyzed and proposed solutions to ensure the reliability and durability of polymer devices in polymer microfabrication against environmental factors such as moisture, temperature fluctuations and adhesion, and surface abrasion.

A Qualitative Research on the Evaluation of Healthcare and Welfare Network for Vulnerable Populations : Focusing on the Dalgubeol Health Doctor Services (취약계층 대상 보건의료·복지 네트워크 사업 성과에 대한 질적연구 : 달구벌건강주치의사업을 중심으로)

  • Su-Jin Lee;Jong-Yeon Kim;Jae-Wook Kang;Hye-Jin Lee
    • Journal of agricultural medicine and community health
    • /
    • v.48 no.4
    • /
    • pp.262-274
    • /
    • 2023
  • Objectives: This study examined the evaluation and potential improvements of 'Integrated Healthcare and Social Welfare service model' based on the experiences of practitioners from institutions participating in the 'Dalgubeol Health Doctor Services' and the service recipients. Methods: Qualitative research was conducted from September to November 2022 in this study, focusing on 4 providers from the dedicated Dalgubeol Health Doctor Services Team, 5 contact partners from affiliated organizations, and 6 service beneficiaries. The data gathered underwent thematic analysis. Results: The evaluation indicated that Dalgubeol Health Doctor Services has proven to be effective in addressing the complex needs of vulnerable populations. By providing integrated services through quick and simple beneficiary selection and resource linkage, it has contributed to the resolution of complex demands, recovery of positive attitudes towards life, and improvement in quality of life for users who have fear the use of medical and welfare services. Dalgubeol Health Doctor Services has established an integrated health care system involving not only public but also private organizations, from the referral agency to the service provider. Centered around Daegu Medical Center and involving five tertiary hospitals, it has established a model that supports treatment appropriate to the severity of the patient, from mild to severe. Conclusions: These findings indicate an enhancement in health equity, achieved through the active identification and subsequent health and welfare issue resolution of individuals marginalized from medical benefits.

A Study on Hydrophobic Surface Treatment for Microfluidic System Fabrication Based on SLA 3D Printing Method (SLA 3D 프린팅 방식 기반의 미세 유체 시스템 제작을 위한 소수성 표면 처리 연구)

  • Jae Uk Heo;Seo Jun Bae;Do Jin Im
    • Korean Chemical Engineering Research
    • /
    • v.62 no.1
    • /
    • pp.105-111
    • /
    • 2024
  • The SLA (Stereolithography Apparatus) method is a type of 3D printing technique predicated on the transformation of liquid photocurable resin into a solid form through UV laser exposure, and its application is increasing in various fields. In this study, we conducted research to enhance the hydrophobicity and transparency of SLA 3D printing surfaces for microfluidic system production. The enhancement of surface hydrophobicity in SLA outputs was attainable through the application of hydrophobic coating methods, but the coating durability under different conditions varied depending on the type of hydrophobic coating. Additionally, to simultaneously achieve the required transparency and hydrophobic properties for the fabrication of microfluidic systems, we applied hydrophobic coatings to the proposed transparency enhancement method from prior research and compared the changes in contact angles. Teflon coating was proposed as a suitable hydrophobic coating method for the fabrication of microfluidic systems, given its excellent transparency and high coating durability in various environmental conditions, in comparison to titanium dioxide coating. Finally, we produced an Electrophoresis of Charged Droplet (ECD) chip, one of the digital microfluidics systems, using SLA 3D printing with the proposed Teflon coating method (Fluoropel 800). Droplet manipulation was successfully demonstrated with the fabricated chip, confirming the potential application of SLA 3D printing technology in the production of microfluidic systems.

Comparative analysis of the in vivo kinetic properties of various bone substitutes filled into a peri-implant canine defect model

  • Jingyang Kang;Masaki Shibasaki;Masahiko Terauchi;Narumi Oshibe;Katsuya Hyodo;Eriko Marukawa
    • Journal of Periodontal and Implant Science
    • /
    • v.54 no.2
    • /
    • pp.96-107
    • /
    • 2024
  • Purpose: Deproteinized bovine bone or synthetic hydroxyapatite are 2 prevalent bone grafting materials used in the clinical treatment of peri-implant bone defects. However, the differences in bone formation among these materials remain unclear. This study evaluated osteogenesis kinetics in peri-implant defects using 2 types of deproteinized bovine bone (Bio-Oss® and Bio-Oss/Collagen®) and 2 types of synthetic hydroxyapatite (Apaceram-AX® and Refit®). We considered factors including newly generated bone volume; bone, osteoid, and material occupancy; and bone-to-implant contact. Methods: A beagle model with a mandibular defect was created by extracting the bilateral mandibular third and fourth premolars. Simultaneously, an implant was inserted into the defect, and the space between the implant and the surrounding bone walls was filled with Bio-Oss, Bio-Oss/Collagen, Apaceram-AX, Refit, or autologous bone. Micro-computed tomography and histological analyses were conducted at 3 and 6 months postoperatively (Refit and autologous bone were not included at the 6-month time point due to their rapid absorption). Results: All materials demonstrated excellent biocompatibility and osteoconductivity. At 3 months, Bio-Oss and Apaceram-AX exhibited significantly greater volumes of formation than the other materials, with Bio-Oss having a marginally higher amount. However, this outcome was reversed at 6 months, with no significant difference between the 2 materials at either time point. Apaceram-AX displayed notably slower bioresorption and the largest quantity of residual material at both time points. In contrast, Refit had significantly greater bioresorption, with complete resorption and rapid maturation involving cortical bone formation at the crest at 3 months, Refit demonstrated the highest mineralized tissue and osteoid occupancy after 3 months, albeit without statistical significance. Conclusions: Overall, the materials demonstrated varying post-implantation behaviors in vivo. Thus, in a clinical setting, both the properties of these materials and the specific conditions of the defects needing reinforcement should be considered to identify the most suitable material.

Analysis of Indicator Microorganism Concentration in the Rice Cultural Plot after Reclaimed Water Irrigation (하수처리수 관개후 벼재배 시험구에서 지표미생물 거동 분석)

  • Jung, Kwang-Wook;Jeon, Ji-Hong;Ham, Jong-Hwa;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.1 s.106
    • /
    • pp.112-121
    • /
    • 2004
  • A study was performed to examine the effects of UV-disinfected reclaimed water on microorganism concentration during rice culture. Four treatments were used and each one was triplicated to evaluate the changes of microorganism concentrations: stream water irrigation (STR), biofilter effluent irrigation (BE), UV-disinfected water irrigation with dose of 6 mW ${\cdot}$ s $cm{-2}$ (UV-6), and UV-disinfected water irrigation with dose of 16 mW ${\cdot}$ s $cm{-2}$ (UV-16). The indicator microorganisms of interest were total coliform (TC), fecal coliform (FC), and E. coli. The biofilter effluent from 16-unit apartment sewage treatment plant was used as reclaimed water and flowthrough type UV-disinfection system was used. Concentrations of indicator microorganisms in the treatment plots ranged from $10^2$ to $10^5$ MPN/100 mL during 24 hours after irrigation in May and June, where initial irrigation water for transplanting reparation was biofilter-effluent without UV-disinfection. It implies that initial irrigation using only non-disinfected reclaimed water for puddling in paddy field can be health-concerned because of more chance of farmer's physical contact with elevated concentration of microorganisms. The concentrations of microorganisms varied widely with rainfall, and treatments using UV-disinfected water irrigation showed significantly lower concentrations than others and their levels were within the range of paddy rice field with normal surface water irrigation. The mean concentrations of STR and BE during growing season were in the range of 4 ${\times}\;10^3$ MPN/100 mL for TC, and 2${\times}\;10^3$ MPN/100 mL for FC and E, Coli, While mean concentrations of UV-S and UV-lS were less than 1${\times}\;10^3$ MPN/100 mL for all the indicator microorganisms. Overall, UV-disinfection was thought to be feasible and practical alternative for agricultural reuse of secondary level effluent in Korea.