• Title/Summary/Keyword: Construction Condition

Search Result 3,663, Processing Time 0.026 seconds

Domestic Aggregate Quality Status and Mechanical Properties of Concrete According to Quality of Aggregate (국내 골재 품질 현황 및 골재등급에 따른 콘크리트의 역학적 특성에 관한 연구)

  • Min, Choong-Siek;Park, Jong-Ho;Jeong, Yong;Lee, Jae-Hyun;Kim, Yong-Ro;Kim, Hyo-Rak
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.207-208
    • /
    • 2012
  • This study is aimed to utilize for basic material of concrete quality management through evaluate properties of fresh and hardened concrete with the aggregate quality. As a result, fine aggregate's slump change of between one grade was 8~82% and in case of coarse aggregate, slump change of between one grade was 2~22% on same mixing condition. The unit water for same workability condition, unit water was increased 16kg/㎥ with decreasing of one grade for fine aggregate and unit water was increased 5kg/㎥ with decreasing of one grade for coarse aggregate.

  • PDF

Temperature Rise of Steel bars Located in a Gang Form Before Placing Concrete During Hot Weather Condition (서중환경시 갱폼 거푸집 내부 철근의 온도변화)

  • Kim, Kyoung-Hoon;Son, Ho-Jung;Lim, Chun Keun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.11-12
    • /
    • 2012
  • This study investigates the temperature rise of reinforcement bars located in the middle of the form (for reinforcement concrete) during hot weather condition. The temperature was measured for three consecutive days before placing concrete. Test results showed that the temperature started to increase at 7:00 AM before sun rised, and peaked at around 2:00 PM. It was found that the thinner the diameter of a reinforcement bar, the higher is the speed of temperature rise and drop of the bar. The peak level of temperature for D13, D19, D25 and D32 was 54.4℃, 55.2℃, 56.4℃ and 60.2℃, respectively.

  • PDF

Strength Development of Mock-up Concrete Structure subjected to Extremely Low Temperature Condition Due to Curing Methods (극저온 조건에서의 양생방법 변화에 따른 실구조체 콘크리트의 강도발현 특성)

  • Jung, Eun-Bong;Jung, Sang-Hyeon;Ahn, Sang-Ku;Ko, Gyeong-Taek;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.47-49
    • /
    • 2012
  • Under this study, the characteristics of concrete intensity condition following the curing method under the extremely low temperature environment have been contemplated, and as a result, in the event of insulation + heat cable curing, the intensity and accumulated temperature accomplishment period is required for two times of requiring initial frost damage prevention than the case of heating + heat insulation curing method due to the insufficient calories supplied in general.

  • PDF

Study on Rock classification of Rock Socketed Drilled Shaft (현장타설말뚝의 암반 근입부 암판정 사례연구)

  • Park, Woan-Suh;Yoo, Jai-Hyun;Lee, Woo-Cheol;Joo, Yong-Sun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.658-663
    • /
    • 2010
  • Recently the most of deep foundation were socketed into weathered rock or soft rock to carry large foundation loads. The end bearing behavior of piles socketed in rock is generally dependent on the rock mass conditions with discontinuities and rock strength. Therefore, it is very important that the estimating rock classification with relation of TCR, RQD and unpredicted rock condition. In this study, the construction failure example of drilled shaft due to mistaking to estimate the rock classification on penetration were analyzed in site, so we hope to discuss problems of determining the rock socketed length of drilled shaft on construction.

  • PDF

A Study on the Actual Condition of Electrical Construction Supervision and Countermeasure of It (전기분야감리제도의 운영실태 및 개선방안에 관한 연구)

  • 고선환;장우진
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.147-150
    • /
    • 2002
  • Domestic electrical construction inspection system was introduced into building site in 1963 by registered architects' law, meanwhile, inspector appointed by ministry of owners lake charge of Government managing building site. Afterwards several systems has been adopted to heal some problems each of them has revealed. These times Government granted authority for inspection on surveillancer, furthermore, formulate a supervising system which articulate the responsibilities of supervision and put it in effect as of 1st, January, 1994. This supervision system gets rid of factors causing faulty work to a considerable extent. However, as it is still in early stage, the system has various problems to overcome, For example, actual state of handling modifications of design in accordance with supervision system in field shows a difference between process provided by law and field process. Thus this study inquire and analyze actual condition of supervision system, at the same time, problems occuring in modifications of design under supervision, and then propose a way to improve it

  • PDF

Frontal Flow Field Construction for Wall Boundary Condition Treatment and Frontal Remeshing Using Spline Curve in Injection Molding Simulation (사술성형 모사에 있어서 벽면 경계조건 처리를 위한 선단 유동장 생성기법과 spline 곡선을 이용한 선단 격자 재구성)

  • 윤재륜
    • The Korean Journal of Rheology
    • /
    • v.5 no.1
    • /
    • pp.34-48
    • /
    • 1993
  • 최근 CAD/CAM의 발전과 더불어 사출성형공정은 여러분야에 폭넓게 응용되고 있 다. 사출성형공정은 크게 충전과정(filling stage), 냉각과정(cooling stage), 보압과정(packing stage)로 나누어 지는데 이중 충전과정은냉각과정과 보압과정에서 나타날 물리적인 현상과 최종 성형품의 기계적 성질에 중요한 영향을 끼치게 된다. 충전과정의 수치 해석 방법은 대 표적으로 control volume method, branching flow method, transient moving boun-dary method로 구분된다. 본 연구에서는 격자의 형태를 양호하게 형성시키고 유동선단의 형태를 개선하기위한 기법인 Spline 곡선을 이용한 선단격자 재구성(frontal remeshing using spline curve)과 수치해석에 소요되는 시간을 줄이기 위하여 벽면경계조건 처리를 위한 선단 유동 장생성(frontal flow field construction for wall boun-dary condition treatment)기법을 개발 하고 transient moving voundary method에 적용시켜 원형 평판과 인장 및 굽힘시편 그리고 두께가 변하는 사각 형상을 가진 캐비터에서의 충전과정을 수치해석하였다. 그결과 압력 분 포, 온도분포, 속도장, 유동선단의 진전형태 등이 기존에 제출된 해석결과와 비교하여 볼 때 만족스러운 수치해석결과를 보였다.

  • PDF

Selection of Priority for Revitalization by Analyzing Rural House Type (농촌주택 유형분석을 통한 재생우선순위 도출)

  • Park, Gil-Beom;Park, Jun-Mo;Kim, Ok-Kyue;Bang, Se-Ra
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.174-175
    • /
    • 2014
  • A Rural house in Chungcheong area have been variety of matters, rapid deterioration of house and incomplete of maintenance control, that is represented lack of durability heating from lack of heat insulation property, health worsening form use of toxic substance and so on. For farmers who did not know where to repair and how to repair, they are urgently needed measures of standard and basis that is to realize a condition of rural house. Accordingly, this study drew major matters and priority for revitalization through analysis of type of rural house from research on the actual condition in order to develope of diagnostic criteria of rural house.

  • PDF

Fundamental Properties of High Quality Concrete Using Grading of Coarse Aggregate by region (권역별 골재 입도보정 사용에 따른 고품질 콘크리트의 기초적 특성)

  • Kim, Dae-Geon;Choi, Sang-Hwan;Moon, Gyeong-Sik;Jo, Man-Ki;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.138-139
    • /
    • 2014
  • In this study, conventional aggregate obtained from a ready mixed concrete factory and the aggregate with a modified grading produced in lab. condition were prepared. Results showed that a good grading of aggregate the ratio of 5~13 mm and 13~25 mm is 20~40 % produced in the lab. condition significantly improved the slump and the compressive strength of the concrete.

  • PDF

Electro Chemical Protection Property for Reinforced Geo-Polymer Specimen Under Ocean Environment and Accelerated Test (철근보강 지오폴리머 콘크리트 시험체에 전기화학적 방식기법 적용과 방식성능 분석)

  • Park, Dong-Cheon;Cho, Gyu-hwan
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.178-179
    • /
    • 2014
  • Corrosion is very serious problem in RC structure under ocean environment. There is no enough experiment information using the reinforced geo polymer concrete applied by electo chemical protection system. Three condition, such as tidal zone, submerged zone and crack were simulated to geo polymer specimen. Corrosion rate and natural electrode potential were measured through accelerated test. Anti corrosion property of geo polymer was better than OPC regardless of specimen condition and applied time.

  • PDF

A Study on the Test Methods of Bond Strength in Waterproofing and Anti-corrosion Materials by Reversed Pressure (역수압 작용을 고려한 방수·방식재의 부착강도 시험방법에 관한 연구)

  • Kim, Meong-Ji;Choi, Su-Young;Choi, Sung-Min;Oh, Sung-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.232-233
    • /
    • 2014
  • Recently, water treatment facility is usually eastablished in underground, and waterproofing and anti-corrosion materials for concrete structures applied water treatment tank is developing in various ways. However, as the limit of research focused on durability improvement of top coating material, it is insufficient to study on the adhesion strength between the concrete surface and primer. Therefore, there is to confirm the adhesion of between concrete surface and the three primers used as anti-corrosion waterproofing materials, and to investigate the properties of adhesion strength according to the condition such as wet codition and water pressure condition of the concrete surface in this study.

  • PDF