• Title/Summary/Keyword: Constant Pressure Control

Search Result 276, Processing Time 0.023 seconds

Effects of Sanjointang on Hemodynamic Functions of Isolated Rat Heart Induced by Sleep Deprivation (산조인탕이 수면박탈 흰쥐 심장의 혈역학적 기능에 미치는 영향)

  • Shin, Yu-Jeong;Kim, Deog-Gon
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.24 no.3
    • /
    • pp.106-120
    • /
    • 2010
  • Objectives: Sanjointang has been clinically used much for treating sleeplessness. However, the effects of Sanjointang in artificial sleep deprivation situations are not known. The purpose of this study is to evaluate the heart rate, left ventricular systolic pressure, left ventricular diastolic pressure, +dp/dt maximum, -dp/dt maximum, and -dp/dt / +dp/dt ratio which are related to the hemodynamic functions of the heart by using sleep-deprived Sparague-Dawley rats, in order to clarify the impact of Sanjointang on hemodynamic functions of the heart of sleep deprived rats. Methods: Eighteen hearts were removed from the male Sparague-Dawley rats weighting about 180g were perfused by the Langendorff technique with modified 37 Krebs-Henseleit's buffer solution at a constant perfusion pressure (60mmHg). They were randomly assigned to one of the following three groups, 1) Normal group (those which did not have sleep deprivation and received normal saline administration), 2) Control group (sleep deprived and normal saline administered), 3) Sample group (sleep deprived and Sanjointang was administered). Control and sample groups rats were deprived 96 hours of sleep by using the modified multiple platform technique. Heart rate, left ventricular systolic pressure, left ventricular diastolic pressure, +dp/dt maximum, -dp/dt maximum, -dp/dt / +dp/dt ratio were evaluated at baseline after the administration of either normal saline or Sanjointang. Results: The heart rate and -dp/dt / +dp/dt ratio was significantly decreased in rats with 96 hours of sleep deprived significantly decreased. The change in the heart rate after administering Sanjointang did not show any significant difference. The left ventricular systolic pressure of the removed heart significantly decreased due to Sanjointang administration, while the left ventricular diastolic pressure significantly increased (p<0.05). The +dp/dt maximum and -dp/dt maximum both significantly decreased in the removed heart after administering Sanjointang. (p<0.05). There was no significant difference observed in the -dp/dt / +dp/dt ratio after administering Sanjointang. Conclusions: According to the results above, sleep deprivation significantly decreases heart rate and -dp/dt / +dp/dt ratio. This is considered as a result of exhaustion due to accumulation of fatigue. Meanwhile, Sanjointang reduced left ventricular systolic pressure and raised left ventricular diastolic pressure, and relieved the contractility and relaxation of the myocardium. Consequently, this reduces the burden of the heart and creates a relatively stabilized heart condition similar to a sleeping condition.

A STUDY ON THE FLOW CHARACTERISTICS OF AIR-KNIFE USING A CONSTANT EXPANSION RATE NOZZLE (팽창률이 일정한 노즐을 사용한 AIR-KNIFE 유동에 관한 연구)

  • Lee, Dong-Won;Kang, Nam-Cheol;Kim, Guen-Young;Kwon, Young-Doo;Kwon, Soon-Bum
    • Journal of computational fluids engineering
    • /
    • v.13 no.4
    • /
    • pp.1-7
    • /
    • 2008
  • In the process of continuous hot-dip galvanizing, it is well known that the gas wiping through an air knife system is most effective because of its uniformity in coating thickness, possibility of thin coating, workability in high speed, and simplicity of control. However, gas wiping used in the galvanizing process brings about a problem of splashing at the strip edge above a certain high speed of process. It is also known that the problem of edge splashing is more harmful than that at the mid strip surface. For a given liquid(of a certain viscosity and surface tension), the onset of splashing mainly depends upon the strip velocity, the gas-jet pressure, and the nozzle's stand-off distance. In these connections in the present study, we proposed three kinds of air knife system having nozzles of constant expansion rate, and compared the jet structures issuing from newly proposed nozzle systems with the result by a conventional one. In numerical analysis, the governing equations are consisted of two-dimensional time dependent Navier-Stokes equations, and the standard k-${\varepsilon}$ turbulence model is employed to solve turbulence stress and so on. As the result, it is found that we had better use the constant expansion-rate nozzle which can be interpreted from the point view of the energy saving for the same coating thickness. Also, we better reduce the size of separation bubble and enhance the cutting ability at the strip surface, by using an air-knife having constant expansion-rate nozzle.

Development and Verification of Analytical Model of a Pilot Operated Flow Control Valve for 21-ton Electric Excavator (21톤급 전기 굴삭기용 파일럿 작동식 유량제어 밸브의 해석모델 개발 및 검증)

  • Kim, D.M.;Nam, Y.Y.;Seo, J.H.;Jang, J.S.
    • Journal of Drive and Control
    • /
    • v.12 no.3
    • /
    • pp.52-59
    • /
    • 2015
  • An electro hydraulic poppet valve (EHPV) and a variable orifice poppet are assembled in a single block, which is referred to as a RHINO but is also generally called a pilot-operated flow control valve. In this study, we analyzed the structure and the operating principle for a RHINO applied in a 21-ton electric excavator system. The RHINO was experimentally tested to measure the dynamic responses and the pressure energy loss. In this test, we investigated the variation in the conductance coefficient according to the increase in the supply pressure under a constant current and a variation in the flow rate according to the increase in the current. Then, the geometrical shapes and the spring stiffness of the RHINO were considered to develop an analysis model. The characteristics (current-force and hysteresis) for the solenoid based on the experimental data were reflected in the analysis model that was developed, and the reliability of the analysis model was also verified by comparing the experimental and analytical results. The developed model is thus considered to be reliable for use in a wide range of applications, including optimum design, sensitivity analysis, parameter tuning, etc.

Hydraulic Characteristics of Deep and Low Permeable Rock Masses in Gyeongju Area by High Precision Constant Pressure Injection Test (고정밀도 정압 주입시험에 의한 경주 지역 대심도 저투수성 암반 수리특성 연구)

  • Bae, SeongHo;Kim, Hagsoo;Kim, Jangsoon;Park, Eui Seob;Jo, Yeonguk;Ji, Taegu;Won, Kyung-Sik
    • Tunnel and Underground Space
    • /
    • v.31 no.4
    • /
    • pp.243-269
    • /
    • 2021
  • Since the early 2010s, the social importance of research and practical projects targeting deep geological disposal of high-level nuclear waste, underground CO2 storage and characterization of deep subsurface by borehole investigation has been increasing. In this regard, there is also a significant increase in the need for in situ test technology to obtain quantitative and reliable information on the hydraulic characteristics of deep rock mass. Through years of research and development, we have independently set up Deep borehole Hydraulic Test System (DHTS) based on the key apparatuses designed and made with our own technology. Using this system, high precision constant pressure injection tests were successfully completed at the two 1 km boreholes located in Mesozoic granite and sedimentary rock regions, Gyeongju. During the field tests, it was possible to measure very low flow rate below 0.01 l/min with micro flow rate injection/control module. In this paper, the major characteristics of DHTS are introduced and also some results obtained from the high precision field tests under the deep and low permeable rock mass environment are briefly discussed.

Composite Pressure Vessel for Natural Gas Vehicle by Filament Winding (필라멘트 와인딩 공정에 의한 천연가스 차량용 복합재료 압력용기)

  • 김병선;김병하;김진봉
    • Composites Research
    • /
    • v.17 no.5
    • /
    • pp.1-6
    • /
    • 2004
  • Composite pressure vessels with HDPE (high density polyethlyne) liner with metal boss at each end were developed by Filament Winding Process. The vessel is composed of a dome-shaped part at each end and a cylinder-shaped part at the middle of the vessel. The environmental tests carried out for possible vessel materials such as High Density Polyethlyn (HDPE), resins and reinforcing fibers up to a year showed no significant damages. The boss was designed to minimize the gas leak which was verified by FEM analysis. Most ideal fiber tension was obtained by experimental method and the fiber volume fraction, $\textrm{V}_{f}$, obtained by image analyzer were 55.4 % in cylinder and 55.6 % in dome parts, respectively. Winding pattern is programmed to control the composite thickness in the dome areas such that the failure of the vessel may occur in the cylinder. During the cure, the vessel was rotated and a constant internal pressure of 0.62 bar was applied. From this, the vessel's burst pressure is improved by 28 %. The burst and fatigue tests for under-wound and fully wound vessel showed satisfactory results.

True Rolling Technique of New Gravure-Offset Printing for R2R Over-Piling (R2R 중첩인쇄를 위한 그라비어오프셋인쇄의 투루롤링 기술)

  • Choi, Byung-Oh;Jo, Jeong-Dai;Kim, Dong-Soo;Lim, Kyu-Jin;Ryu, Byung-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.10
    • /
    • pp.1131-1140
    • /
    • 2011
  • A new rotary gravure-offset printing unit is constructed by paralleling a gravure plate cylinder, a blanket cylinder and a impression roller. A Muti-Unit Gravure-Offset Printing Press(MUGOP) equipped with a series of the 3 printing units is utilized for roll-to-roll fine printing. Its core technology is precise over-piling printing of fine patterns. The severe problems of 'slurring' and 'doubling' in typical offset printing are unavoidable, which can be eliminated by applying a soft pad-type blanket cylinder and the unique 'true rolling' technique. Nip pressure between the blanket cylinder and the plate cylinder is measured by the constant pressure control system which equipped with load cells attached on the cylinders' axes. The running circumference of the blanket cylinder is increased to reach the same circumference of the plate cylinder as the pressure increasing, so that the specifications of the blanket cylinder is determined by the relationships of its shore hardness, diameter and nip pressure. When a softer blanket is used, a blanket cylinder of smaller diameter could give higher nip pressure. Realization of the true rolling technique on the MUGOP makes multilayer printing possible as well as fine printing in printed electronics.

Model for Estimating CO2 Concentration in Package Headspace of Microbiologically Perishable Food

  • Lee, Dong-Sun;Kim, Hwan-Ki;An, Duck-Soon;Yam, Kit L.
    • Preventive Nutrition and Food Science
    • /
    • v.16 no.4
    • /
    • pp.364-369
    • /
    • 2011
  • Levels of carbon dioxide gas, a metabolite of microbial growth, have been reported to parallel the onset of microbial spoilage and may be used as a convenient index for a packaged food's shelf life. This study aimed to establish a kinetic model of $CO_2$ production from perishable food for the potential use for shelf life control in the food supply chain. Aerobic bacterial count and package $CO_2$ concentration were measured during the storage of seasoned pork meat at four temperatures (0, 5, 10 and $15^{\circ}C$), and their interrelationship was investigated to establish a mathematical model. The microbial growth at constant temperature was described by using model of Baranyi and Roberts. $CO_2$ production from the stored food could be explained by taking care of its yield and maintenance factors linked to the microbial growth. By establishing the temperature dependence of the microbial growth and $CO_2$ yield factor, $CO_2$ partial pressure or concentration in package headspace could be estimated to a limited extent, which is helpful for controlling the shelf life under constant and dynamic temperature conditions. Application and efficacy of the model needs to be improved with further refinement in the model.

THEORETICAL ANALYSIS FOR STUDYING THE FRETTING WEAR PROBLEM OF STEAM GENERATOR TUBES IN A NUCLEAR POWER PLANT

  • LEE CROON YEOL;CHAI YOUNG SUCK;BAE JOON WOO
    • Nuclear Engineering and Technology
    • /
    • v.37 no.2
    • /
    • pp.201-206
    • /
    • 2005
  • Fretting, which is a special type of wear, is defined as small amplitude relative motion along the contacting interface between two materials. The structural integrity of steam generators in nuclear power plants is very much dependent upon the fretting wear characteristics of Inconel 690 U-tubes. In this study, a finite element model that can simulate fretting wear on the secondary side of the steam generator was developed and used for a quantitative investigation of the fretting wear phenomenon. Finite element modeling of elastic contact wear problems was performed to demonstrate the feasibility of applying the finite element method to fretting wear problems. The elastic beam problem, with existing solutions, is treated as a numerical example. By introducing a control parameter s, which scaled up the wear constant and scaled down the cycle numbers, the algorithm was shown to greatly reduce the time required for the analysis. The work rate model was adopted in the wear model. In the three-dimensional finite element analysis, a quarterly symmetric model was used to simulate cross tubes contacting at right angles. The wear constant of Inconel 690 in the work rate model was taken as $K=26.7{\times}10^{-15}\;Pa^{-1}$ from experimental data obtained using a fretting wear test rig with a piezoelectric actuator. The analyses revealed donut-shaped wear along the contacting boundary, which is a typical feature of fretting wear.

Mixed Flow and Oxygen Transfer Characteristics of Vertical Orifice Ejector (수직 오리피스 이젝터의 혼합유동 및 산소전달 특성)

  • Kim, Dong Jun;Park, Sang Kyoo;Yang, Hei Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.1
    • /
    • pp.61-69
    • /
    • 2015
  • The objective of this study is to experimentally investigate the mixed flow behaviors and oxygen transfer characteristics of a vertical orifice ejector. The experimental apparatus consisted of an electric motor-pump, an orifice ejector, a circulation water tank, an air compressor, a high speed camera unit and control or measurement accessories. The mass ratio was calculated using the measured primary flow rate and suction air flow rate with experimental parameters. The visualization images of vertically injected mixed jet issuing from the orifice ejector were qualitatively analyzed. The volumetric oxygen transfer coefficient was calculated using the measured dissolved oxygen concentration. At a constant primary flow rate, the mass ratio and oxygen transfer coefficient increase with the air pressure of compressor. At a constant air pressure of the compressor, the mass ratio decreases and the oxygen transfer coefficient increases as the primary flow rate increases. The residence time and dispersion of fine air bubbles and the penetration of mixed flow were found to be important parameters for the oxygen transfer rate owing to the contact area and time of two phases.

Numerical Analysis and Optimum Design of Disposable Drug Infuser Using Fluid-Structure Interaction Technique (유체-구조 상호작용기법을 이용한 일회용 약물주입기의 성능 해석 및 최적 설계)

  • Kim, Heon-Young;Kim, Hak-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1595-1602
    • /
    • 2010
  • A disposable drug infuser is used to provide drugs to patients who are not hospitalized; in this infuser, an elastic recovery force is exerted by a diaphragm made of a rubber-like materialsuch that a constant amount of drugs is provided to a patient. The drug infuser has to control the speed and amount of drugs to be released, as well as the overall duration for which they are to be administered. However, in a drug infuser with an elastic diaphragm, the infusion pressure depends on the amount of drug remaining within the infuser, and the amount of drug infused gradually decreases as the amount remaining in the infuser decreases. In this study, a finite element procedure involving the application of the fluid-structure interaction technique was developed and the performance of the elastic type disposable drug infuser was analyzed. The optimum design for ensuring that the infusion pressure remains constant throughout the duration of usage, including during infusion and discharge, was determined by this procedure.