• Title/Summary/Keyword: Constant Correction

Search Result 239, Processing Time 0.026 seconds

A Case of Seismic Crosshole Tomography Applying Borehole Deviation Correction (시추공 편차 보정을 적용한 탄성파시추공토모그래피 사례)

  • Kang, Jong-Seok;Cha, Young-Ho;Jo, Churl-Hyun;Choi, Jong-Ho;Shim, Weon-Hum;Park, Yong-Sung
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.221-224
    • /
    • 2006
  • seismic crosshole tomography works applying borehole deviation correction were performed at a test site to detect a small cavity. Two correction methods were applied. The one is the constant distance correction which adds constant distance to surface borehole distance and the other is the constant angle correction which considers an angle between surface borehole location and bottom borehole location. After applying the corrections, the distortions of the image diminished while its resolution improved. Though the constant angle correction is the most appropriate correction method, the constant distance correction can delineate the small cavity sufficiently.

  • PDF

A Study on the Correction Factor of Flow Angel by using the One Dimentional Performance Model of Torque Converter (토크 컨버터의 1차원 성능 모델을 이용한 유동 각도 보정 계수에 관한 연구)

  • Im, Won-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.2 s.173
    • /
    • pp.506-517
    • /
    • 2000
  • One dimensional performance model has been used for the design of torque converter. The model is based on the concept of constant mean flow path and constant flow angle. These constant-assumed para meters make the design procedure to be simple. In practice, some parameters are usually replaced with geometric raw data and, the constant experiential correction factors have been used to minimize the design error. These factors have no definite physical meaning and so they cannot be applied confidently to the other design condition. In this study, the detail dynamic model of torque converter is presented to establish the theoretical background of correction factors. To verify the validity of theoretical model, steady state performance test was carried out on the several input speed. The oil temperature effect on the performance is analysed and adjusted. The constant equivalent flow angles are determined at a part of performance region by comparing the theoretical model and the test data. The sensitivity of correction factors to the input speeds are studied and the change of torus flow is presented.

A Power Supply System for Lighting of Aerodromes by Using Power Factor Correction and Constant Current Regulator (PFC 및 CCR에 의한 항공조명용 전원공급장치의 개발)

  • Shon, Jin-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2150-2156
    • /
    • 2007
  • According as level of industry develops day after day, electricity load system of industry requires high level control, effectiveness and high efficiency. Among supply and control unit of suitable power supply in these load characteristic, inverter systems of constant current regulate is used widely control of lighting and electric heating system. But, problems that power factor deterioration and fast response of control, efficiency, harmonics and etc are still remain. Therefore, in this paper proposed an inverter systems with constant current regulation and power factor correction (PFC) circuit for lighting and beaconing of aerodromes. The effectiveness of the proposed system confirmed through experimental results of 10[kW] power supply system.

Error Correction by Redundant Bits in Constant Amplitude Multi-code CDMA

  • Song, Hee-Keun;Kim, Sung-Man;Kim, Bum-Gon;Kim, Tong-Sok;Ko, Dae-Won;Kim, Yong-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.11C
    • /
    • pp.1030-1036
    • /
    • 2006
  • In this paper, we present two methods of correcting bit errors in constant amplitude multi-code (CAMC) CDMA, which uses the redundant bits only. The first method is a parity-based bit correction with hard-decision, where the received signals despread into n two-dimensional structure with both horizontal parity and vertical parity. Then, an erroneous bit is corrected for each $4{\times}4$ pattern. The second method is a turbo decoding, which is modified from the decoding of a single parity check product code (SPCPC). Experimental results show that, in the second method, the redundant bits in CAMC can be fully used for the error correction and so they are not really a loss of channel bandwidth. Hence, CAMC provides both a low peak-to-average power ratio and robustness to bit errors.

Scaling theory to minimize the roll-off of threshold voltage for ultra fine MOSFET (미세 구조 MOSFET에서 문턱전압 변화를 최소화하기 위한 최적의 스켈링 이론)

  • 정학기;김재홍;고석웅
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.4
    • /
    • pp.719-724
    • /
    • 2003
  • In this paper, we have presented the simulation results about threshold voltage of nano scale lightly doped drain (LDD) MOSFET with halo doping profile. Device size is scaled down from 100nm to 40nm using generalized scaling. We have investigated the threshold voltage for constant field scaling and constant voltage scaling using the Van Dort Quantum Correction Model (QM) and direct tunneling current for each gate oxide thickness. We know that threshold voltage is decreasing in the constant field scaling and increasing in the constant voltage scaling when gate length is reducing, and direct tunneling current is increasing when gate oxide thickness is reducing. To minimize the roll off characteristics for threshold voltage of MOSFET with decreasing channel length, we know $\alpha$ value must be nearly 1 in the generalized scaling.

Scaling theory to minimize the roll-off of threshold voltage for nano scale MOSFET (나노 구조 MOSFET의 문턱전압 변화를 최소화하기 위한 스케일링 이론)

  • 김영동;김재홍;정학기
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.494-497
    • /
    • 2002
  • In this paper, we have presented the simulation results about threshold voltage of nano scale lightly doped drain (LDD) MOSFET with halo doping profile. Device size is scaled down from 100nm to 40nm using generalized scaling. We have investigated the threshold voltage for constant field scaling and constant voltage scaling using the Van Dort Quantum Correction Model(QM) and direct tunneling current for each gate oxide thickness. We know that threshold voltage is decreasing in the constant field scaling and increasing in the constant voltage scaling when gate length is reducing, and direct tunneling current is increasing when gate oxide thickness is reducing. To minimize the roll-off characteristics for threshold voltage of MOSFET with decreasing channel length, we know u value must be nearly 1 in the generalized scaling.

  • PDF

Approximate Multiplier With Efficient 4-2 Compressor and Compensation Characteristic (효율적인 4-2 Compressor와 보상 특성을 갖는 근사 곱셈기)

  • Kim, Seok;Seo, Ho-Sung;Kim, Su;Kim, Dae-Ik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.1
    • /
    • pp.173-180
    • /
    • 2022
  • Approximate Computing is a promising method for designing hardware-efficient computing systems. Approximate multiplication is one of key operations used in approximate computing methods for high performance and low power computing. An approximate 4-2 compressor can implement hardware-efficient circuits for approximate multiplication. In this paper, we propose an approximate multiplier with low area and low power characteristics. The proposed approximate multiplier architecture is segmented into three portions; an exact region, an approximate region, and a constant correction region. Partial product reduction in the approximation region are simplified using a new 4:2 approximate compressor, and the error due to approximation is compensated using a simple error correction scheme. Constant correction region uses a constant calculated with probabilistic analysis for reducing error. Experimental results of 8×8 multiplier show that the proposed design requires less area, and consumes less power than conventional 4-2 compressor-based approximate multiplier.

Power Factor Correction in ZVT PWM Boost Converter (ZVT PWM Boost 컨버터에 있어서의 역률개선)

  • Kim, Jin-Sung;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.619-621
    • /
    • 1996
  • This paper presents the study on the development of the power factor correction convener with ZVT Boost converter, which is better than the conventional PWM Boost converter to increase the switching frequency for high density and lower stress of switch. A simple DC and small signal model for the power factor correction converter with constant switching frequency is derived. The guide line for design of controller is summarized.

  • PDF

CORRECTION METHOD OF ESTIMATED INSERTION-LOSS WITH FLOW

  • Nishimura, Tsuyoshi;Usagawa, Tsuyoshi;Ebata, Masanao
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.746-751
    • /
    • 1994
  • The four-terminal transmission matrix method has been widely used to estimate the insertion-loss. However, the predictins using the equations in the four-terminal transmission matrix method do not reflect a practical phenomenon accurately, In this paper, the correction method to derive the insertion-loss for a constant sound pressure source is presented. The method of correction to the four-terminal transmission matrix method was proposed by rewriting the real and imaginary parts as they depend solely on the flow velocity. Then the result was compensated for by adding the component of the temperature gradient.

  • PDF

Position Correction Method for Misaligned Hall-Effect Sensor of BLDC Motor using BACK-EMF Estimation (역기전력 추정법을 이용한 브러시리스 직류 전동기의 홀센서 상전류 전환시점 보상 방법)

  • Park, Je-Wook;Kim, Jong-Hoon;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.246-251
    • /
    • 2012
  • This paper proposes a new position compensation method for misaligned Hall-effect sensors of BLDCM(Brushless DC Motor). If the Hall-effect sensors are installed at wrong position, the exact rotor position cannot be obtained. Therefore, when the BLDCM is controlled with this wrong position, the torque ripple can be increased and the average torque also decreases. The back-EMF of BLDCM can be obtained by using the voltage equation and by multiplying the back-EMF constant and rotor speed. At a constant speed, the estimated back-EMF by using the multiplication of the back-EMF constant and rotor speed is constant, but the estimated back-EMF from the voltage equation decreases at the commutation point because the line-to-line back-EMF of two conducting phases is start to decrease at this point. Therefore, by using the difference between these two estimated back-EMFs, the commutation point of the phase current can be determined and position compensation can be carried out. The proposed position correction method doesn't require additional hardware circuit and can be easily implemented. The validity of the proposed position compensation method is verified through several experiments.