• Title/Summary/Keyword: Connection Management)

Search Result 1,442, Processing Time 0.03 seconds

A Unified Design Methodology Development For XML Application based on Relational Database using UML Class (UML 클래스를 이용한, 관계형 데이터베이스 기반의 XML 응용을 위한 통합 설계 방법론 개발)

  • 방승윤;주경수
    • The Journal of Society for e-Business Studies
    • /
    • v.8 no.1
    • /
    • pp.85-102
    • /
    • 2003
  • Nowadays an information exchange on XML such as B2B electronic commerce is spreading. Therefore the systematic and stable management mechanism for storing the exchanged information is needed. For this goal there are many research activities for connection between XML application and relational database. But because XML data have hierarchical structures and relational database can store only flat-structured data, we need to make the conversion rule which changes the hierarchical architecture to 2-dimensional information. Accordingly the modeling methodology for storing each structured information in relational database is needed. In this paper, we introduce a XML modeling methodology to design W3C XML schema using UML and we propose a unified design methodology for relational database schema to store XML data efficiently in relational databases. In the second place, in order to verify objectivity of a unified design methodology. By the way of Ronald Bourret, First we introduce the method of the transformation from XML schema to object model and second we translate object model into relational database schema. Therefore we show the mutual consistency between those consequence, and so can verify a unified design methodology.

  • PDF

Evaluation of Community Health Center for Vulnerable Population in Urban Areas (취약계층 주민을 위한 도시형 지역사회중심 간호센터 평가)

  • Park, Kyung-Min;Kim, Chung-Nam;Koh, Hyo-Jung;Park, Yeong-Sook;Park, Jung-Sook
    • Research in Community and Public Health Nursing
    • /
    • v.18 no.2
    • /
    • pp.266-275
    • /
    • 2007
  • Purpose: The purpose of this study was to evaluate achievements of a community health center for vulnerable population in urban areas and to find out its strength and weakness. Method: This evaluative study employed system theories and analytic techniques. Results: The purpose of improving vulnerable population's health-related self-care abilities adequately met the operation of programs. This center maintained close connection to a nursing college as a information resource. The subjects' satisfaction was high because team members who visited them were faithful and there were face-to-face contact, sufficient time set, closeness and resourcefulness. There were needs for regular meetings to discuss overall matters in organizing the program and to improve management skills. The mean score of health promotion lifestyle was 2.23 on a 4 point scale. This score indicates what in higher than vulnerable people in other communities. Conclusions: Community-based nursing centers for vulnerable population in urban areas should be developed as support organizations and community network.

  • PDF

The intruder traceback mechanism based on active networks (액티브 네트워크 기반 침입자 역추적 메커니즘)

  • Lee Young-seok
    • Journal of Internet Computing and Services
    • /
    • v.6 no.1
    • /
    • pp.1-12
    • /
    • 2005
  • Recently, the patterns of cyber attack through internet have been various and have become more complicated and thus it is difficult to detect a network intruder effectively and to response the intrusion quickly. Therefore, It is almost not possible to chase the real location of a network intruder and to isolate the Intruder from network in UDP based DoS or DDoS attacks spoofing source IP address and in TCP based detour connection attacks. In this paper, we propose active security architecture on active network to correspond to various cyber attacks promptly. Security management framework is designed using active technology, and security control mechanism to chase and isolate a network intruder is implemented. We also test the operation of the active security mechanism implemented on test_bed according to several attack scenarios and analyze the experiment results.

  • PDF

Study on Current Limiting Characteristics of YBCO Thin-Film Wire with Insulation Layer

  • Doo, Seung-Gyu;Du, Ho-Ik;Jeon, An-Gyoon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.1
    • /
    • pp.20-23
    • /
    • 2013
  • When applying superconducting wire to power machines, an investigation needs to be carried out on the characteristics of wire phase changes in connection with the insulating layer. This study examined trends in the increase of the wire's resistance and the characteristics of its recovery from quenching by a current-applied cycle at temperatures of 90 K, 180 K, and 250 K. The procedure was conducted based on the thickness and presence (or absence) of the insulating wire layers. To achieve this, YBCO thin-film wires with the same critical temperatures were prepared with copper and stainless steel stabilizing layers. At levels (-one, three, and five-), with superior performance, polyimide pressure-sensitive adhesive tape was attached to the wires at a very low temperature. The eight prepared test samples were wound around the linear frames. The wire's voltage and current created from the phase change characteristics were measured at the wire's prescribed temperature, using the four-point probe method. The wire's resistance and recovery characteristics were examined for each cycle at temperatures of 90 K, 180 K, and 250 K.

Internet Based Remote Control and Monitoring System using Digital Timer (디지털 타이머를 이용한 인터넷 기반의 원격제어 및 모니터링)

  • Lee Y.G.;Kang S.Y.;Kim E.J.;Bark C.S.;Lim Y.C.;Kim G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.83-88
    • /
    • 2001
  • This paper deals with the economical equipment control which is used by internet network system at the industrial workplace. If the control devices can be accessed by internet, we can have the developed possibility of work conditions. In this paper, we presented the advanced digital timer which has a communication function to control and observe panel to realize control solution based on internet to be easily applicable at workplace with low cost. and we used 485 serial communication module to have parallel expansibility and safety. And, this system was experimented and designed for easy system management and status check from remote station through internet As the result of experiment, the circuit configuration would be more simplified than the existing, and it is expected that multi connection control and monitoring can be simply implemented with low cost equipment at industrial workplace.

  • PDF

Modified BLUE Packet Buffer for Base-Stations in Mobile IP-based Networks

  • Hur, Kyeong
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.5
    • /
    • pp.530-538
    • /
    • 2011
  • Performance of TCP can be severely degraded in Mobile IP-based wireless networks where packet losses not related to network congestion occur frequently during inter-subnetwork handoffs by user mobility. To solve such a problem in the networks using Mobile IP, the packet buffering method at a base station(BS) recovers those packets dropped during handoff by forwarding the buffered packets at the old BS to the mobile users. But, when the mobile user moves to a congested BS in a new foreign subnetwork, those buffered packets forwarded by the old BS are dropped and TCP transmission performance of a mobile user degrades severely. In this paper, we propose a Modified BLUE(MBLUE) buffer required at a BS to increase TCP throughput in Mobile IP-based networks. When a queue length exceed a threshold and congestion grows, MBLUE increases its packet drop probability. But, when a TCP connection is added at new BS by a handoff, the old BS marks the buffered packets. And new BS receives the marked packets without dropping. Simulation results show that MBLUE buffer reduces congestion during handoffs and increases TCP throughputs.

The Operating Characteristics Analysis of Utility Interactive PV Power Generation System (계통연계형 태양광 발전시스템의 운전특성 분석)

  • 이현우;고강훈
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.23-30
    • /
    • 2003
  • This paper analyzes the characteristic of utility connection type solar power generation system which it is available to connect the utility. And the operation characteristic of this system is compared and analyzed when it is operated in the real system. The constructional and operational problem were obtained by that result. Overcoming that defect is that finding the proper place to be well operated and to find the best place for getting the sunshine data. This method could increase the efficiency of the generation system. And more, current OS in operating system and monitoring management couldn't solve the problem so that improving OS and constructing data backup system should be implemented, This paper proposes the plan to solve that defect in the real system.

Proactive Data Dissemination Protocol on Distributed Dynamic Sink Mobility Management in Sensor Networks (센서 네트워크에서 다수의 이동 싱크로의 에너지 효율적인 데이터 전파에 관한 연구)

  • Hwang Kwang-Il;Eom Doo-Seop;Hur Kyeong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.9B
    • /
    • pp.792-802
    • /
    • 2006
  • In this paper, we propose an energy-efficient proactive data dissemination protocol with relatively low delay to cope well with highly mobile sink environments in sensor networks. In order for a dissemination tree to continuously pursue a dynamic sink, we exploit two novel algorithms: forward sink advertisement and distributed fast recovery. In our protocol, the tree is shared with the other slave sinks so that we call it Dynamic Shared Tree (DST) protocol. DST can conserve considerable amount of energy despite maintaining robust connection from all sources to sinks, since tree maintenance of DST is accomplished by just distributed local exchanges. In addition, since the DST is a kindof sink-oriented tree, each source on the DST disseminates data with lower delay along the tree and it also facilitates in-network processing. Through simulations, it is shown that the presented DST is considerably energy-efficient, robust protocol with low delay compared to Directed Diffusion, TTDD, and SEAD, in highly mobile sink environment.

DC-Voltage Regulation for Solar-Variable Speed Hybrid System (태양광 기반의 가변속 하이브리드 시스템을 위한 직류 전압 제어)

  • Niyitegeka, Gedeon;Lee, Kyungkyu;Choi, Jaeho;Song, Yujin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.3
    • /
    • pp.231-237
    • /
    • 2016
  • Recently, the interest in DC systems to achieve more efficient connection with renewable energy sources, energy storage systems, and DC loads has been growing extensively. DC systems are more advantageous than AC systems because of their low conversion losses. However, the DC-link voltage is variable during operation because of different random effects. This study focuses on DC voltage stabilization applied in stand-alone DC microgrids by means of voltage ranges, power management, and coordination scheme. The quality and stability of the entire system are improved by keeping the voltage within acceptable limits. In terms of optimized control, the maximum power should be tracked from renewable resources during different operating modes of the system. The ESS and VSDG cover the power shortage after all available renewable energy is consumed. Keeping the state of charge of the ESS within the allowed bands is the key role of the control system. Load shedding or power generation curtailment should automatically occur if the maximum tolerable voltage variation is exceeded. PSIM-based simulation results are presented to evaluate the performance of the proposed control measures.

Evaluation for mechanical hardness of gas turbine rotor bolt according to deterioration of specimen (시편의 열화에 따른 가스터빈 로터볼트 기계적 강도평가)

  • Gil, D.S.;Ahn, Y.S.;Park, S.K.
    • Journal of Power System Engineering
    • /
    • v.15 no.4
    • /
    • pp.19-24
    • /
    • 2011
  • The operational efficiency of domestic gas turbine is about 25% and it is now in the trend of the gradual growth in spite of the severe temperature, frequent starting and shutdown according to the environmental management and the energy-efficient use. Rotor bolts of gas turbine in power plants have been the cause of defects because these gas turbines have been operated for a long time under the high pressure and temperature environment experiencing the aging change and stress concentration of the bonded part. The connection parts of the bolt revealed various failure shape and these parts were elongated under very low pressure when operated in the relaxed condition. The cause is in the lack of the metal distribution in the bottle lack area and the cap screw of the bolt is broken totally in case that the nut is fastened in most cases. Gas turbine rotor bolts are connected to the rotor wheel and these bolts caused the vibration, the bulk accident of the rotor in the event that the coupling power among these bolts was relaxed. Therefore, we would like to evaluate the soundness of the main part of the gas turbine rotor bolt through the measurement of the inner condition change along with the mechanic deterioration and temperature, stress in the gas turbine rotor material.