• Title/Summary/Keyword: Connecting Rate

Search Result 218, Processing Time 0.02 seconds

MDP-Based Stepwise Network Reconfiguration Scheme for Dynamic WDM Network (동적 WDM네트워크를 위한 MDP기반의 단계적 망 재구성 기법)

  • Park, Byoung-Seob
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.1
    • /
    • pp.160-168
    • /
    • 2008
  • We completed a new cluster system based on WDM by proposing virtual topology reconfiguration schemes. The key idea of the proposed scheme Is to construct a set with the longest chains of requests of connecting nodes which need to be assigned a wavelength. All the sets have no common factor, that is, there is no duplicated link among the requests of connecting. After making the set satisfying this condition, we could assign a wavelength to per corresponding set. We could reconfigure a virtual topology with this scheme collectively. we compared our scheme to existing approaches by the OWns simulation tool. As the results, we gained improved performances, reducing 10% of blocking rate and improving 30% of ADM utilization in terms of the blocking probability and the ADM utilization.

A Study on Women's Wear Manufacturing Industries (II) - Automation of the Facilities and Ratio of Impaired goods - (숙녀복(淑女服) 봉제업계(縫製業界) 실태(實態) 연구(硏究) (II) - 생산설비(生産設備) 자동화(自動化)와 생산제품(生産製品) 불량수준(不良水準) -)

  • Uh, Mi-Kyung;Sohn, Hee-Soon
    • Journal of Fashion Business
    • /
    • v.1 no.2
    • /
    • pp.46-54
    • /
    • 1997
  • The purpose of this study is to understand women's wear manufacturing industries. First, the study was to investigate the present production systems and how much the automatic facility are by comparing them. This study enhanced more efficient, stable, and suitable work line. This intern will direct the way in which automatic facilities will be created. Second, through this study on the general character of the inspectors, the ratio of impaired goods, and the reasons for unsatisfactory goods, I intended to find out a way to decrease the impaired goods and to produce competitive and high quality goods. The results of the survey can be summarized as follows; 1. The result of the research on the automatic industrial facilities shows that the majority of the factories (77.4%) are 40% below the automatic facility rate. The reasons for this according to order are that was a deficit in money, no reason for expensive machines, and lack of the technique and the number of workers required to handle the machines. 2. At this time, the most required equipments are shown according to its importance; automatic sewing machine, automatic cutting machine, automatic spreading machine, and finishing & pressing machine. So in the women's wear manufacturing industries, they think that they need more automatic cutting machine, automatic spreading machine in the cutting field rather than high price automatic machine in the sewing field such as pattern former, pocket welting, automatic sleeve connecting machine and automatic label connecting machine. 3. The result of the research in the goods quality shows that the average impaired rate is 12.7% at the first inspection. In addition the average rate for complete impaired rate is 1.52%. The line system shows that it has a impaired rate that is double the rate of the pair system. Because of this, the industries plan to combine the line system and pair system to create an improved and suitable production system which can boost the quality and productivity of the goods. 4. The fabric is the main point of the impaired goods. The factors of the impaired goods in manufacturing are the lack of mental abilities of the worker, impaired fabrics and a lack of cooperation in the working system. Furthermore, there is a lack of technique for new material. 5. To prohibit impaired goods in manufacturing, there need to be a way to educate the workers and to enhance the workers' mind on the productive goods. Also there need to increase in the investments of automatic production machines. Finally there need to be a standardized working line. Therefore, there need to be an improvement on the management of the production of goods, the development of technique and an increase in the education for the workers, with this there will be a decrease in impaired goods, and an increase in better quality of goods to enforce the domestic apparel industries.

  • PDF

The Optimized Standards and Criteria for Installing Switches on Distribution Feeder (국내 배편계통의 최적 개폐기 설치 기준)

  • Jo, Nam-Hun;Ha, Bok-Nam;Lee, Heung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.5
    • /
    • pp.238-246
    • /
    • 2002
  • Utilities are trying to install the equipment of high quality to avoid deterioration of supply reliability. In addition, many sectionalizing switches which can decrease the total outage value for a fault are installed for the same reason. Therefore, utilities are interested in stun dards and criteria for installing switches to optimize the total cost on distribution systems. The affect of sectionalizing switches installed on distribution feeder is gradually decreased because the failure rate on distribution feeder is decreased. Also the automation for distribution systems is widely applied for the efficient operation. Therefore, the renewal for installation standards of sectionalizing switches Is required to reflect the current operation situation. The variable data is used to consider the KEPCO's real situation of distribution feeder as follows; the feeder capacity, connecting rate, feeder length, failure rate of distribution feeder, the failure rate of switches, perception time of feeder fault, the restoration time for a faulted section, the transfer time to other feeders, and the switching time. In this study, We propose equations which can determine the number of sectionalizing switches for minimizing the outage and switch installation cost.

The optimized standards and criteria for installing switches on distribution feeder (국내 배전계통의 최적 개폐기 설치 기준(I))

  • Cho, Nam-Hun;O, Jae-Hyeong;Lee, Heung-Ho;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.70-73
    • /
    • 2002
  • Utilities are trying to install the equipment of high quality to avoid deterioration of supply reliability. In addition, many sectionalizing switches which can decrease the total outage value for a fault are installed for the same reason. Therefore, utilities are interested in standards and criteria for installing switches to optimize the total cost on distribution systems. The affect of sectionalizing switches installed on distribution feeder is gradually decreased because the failure rate on distribution feeder is decreased. Also the automation for distribution systems is widely applied for the efficient operation. Therefore, the renewal for installation standards of sectionalizing switches is required to reflect the current operation situation. The variable data is used to consider the KEPCO's real situation of distribution feeder as follows; the feeder capacity, connecting rate, feeder length, failure rate of distribution feeder, the failure rate of switches, perception time of feeder fault, the restoration time for a faulted section, the transfer time to other feeders, and the switching time. In this study, We propose equations which can determine the number of sectionalizing switches for minimizing the outage and switch installation cost.

  • PDF

Comparison of Egress Modeling and Experiments for Joint Flow Rate in the Staircase (피난계단 합류 시 유동률에 대한 피난실험 및 모델링 비교)

  • Hwang, Eun-Kyoung;Woo, Sujin;Kim, Jong-Hoon;Kim, Woon-Hyung
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.41-46
    • /
    • 2014
  • Junction at the staircase is one of key factors for building egress analysis. The most important factor is the congestion at the door or somewhere connecting from bigger area to smaller one. The other factor is the congestion in the staircase. It happens when people from upper floors meets people from the connecting floor. Especially egress situation at the high-rise building is worse. The simulation of the junction is only described by physical agent algorithms in egress model. For that reason, the description of phenomena will validate with the result of experiment and estimate the gap between modeling and experiment. In this research, the experiment of the junction and the simulation was conducted and validated. The gap between the experiment and the modeling was estimated. The flow rates of modeling were lower than the modeling.

Experimental Study on the Effect of DC Electric Field on Extinction Characteristics of Counterflow Diffusion Flame (대향류 확산화염의 소염특성에 미치는 직류전기장의 영향에 관한 실험적 연구)

  • Park, I.H.;Kim, M.K.;Won, S.H.;Cha, M.S.;Chung, S.H.
    • 한국연소학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.253-259
    • /
    • 2006
  • The effect of DC electric fields on the flame extinction was investigated experimentally in counterflow configurations for the methane/oxygen/nitrogen diffusion flame. The electric fields was applied by connecting the high voltage and ground terminals to the upper and lower burners, respectively. In case of having electric fields, several modes of flame extinction was observed according to the electric field intensity and strain rate defined by the exit velocity. To visualize and characterize the flame structure and intensity, planar LIF technique was adopted for OH radicals. Consequently, several length scales, including the flame width, thickness, and height from the burner tip, were introduced to explain the various flame behaviors and to characterize the flame extinctions. It was found that the variation of flame width and the chemical reaction are strongly related to a critical electric field intensity, thus the various modes of diffusion flame extinction could be observed due to the electric fields.

  • PDF

Rheological Properties of Cooked Noodles with Different Starch Content Using Tensile Tests

  • Kim, Su-Kyoung;Lee, Seung-Ju
    • Food Science and Biotechnology
    • /
    • v.18 no.4
    • /
    • pp.1013-1018
    • /
    • 2009
  • Several rheological terms were introduced to estimate the properties of cooked noodles with different starch content using tensile tests. Ring-shaped specimens were prepared by connecting both ends of the noodle strip before cooking. Hencky strain and rate, as well as true stress were applied in constant deformation tests. The elastic region on the curves of strain vs. stress was not clearly identified. Strain hardening in the subsequent plastic region was more prominent in low-starch noodles. Elongational viscosities at lower strain rates were used to differentiate noodles with different starch content, representing the dominant effect of protein content in the range of lower strain rates. In stress relaxation tests, the reciprocal of Peleg's constant $K_1$ (initial decay rate) and $K_2$ (asymptotic level) increased and decreased respectively, with an increase in starch content. This indicated that addition of starch contributed to the noodles becoming viscous liquid rather than elastic solid.

Durability Characteristics of Glass Fiber Reinforced Polymer Composite Clapping Plates for Application of Rubber Dam (고무댐에 적용하기 위한 유리섬유보강 복합재료 클랩핑 플레이트의 내구 특성)

  • Lee, Jeong-Woo;Park, Chan-Gi;Kim, Jong-Ok;Lee, Seung-Kee;Kim, Pil-Sik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.5
    • /
    • pp.17-23
    • /
    • 2011
  • Steel clapping plate is used to connecting rubber body in rubber dam. However, once the steel clapping plate corrodes, it may cause faults, such as the same problems experienced by typical reinforcing steel. This study evaluated the applicability of glass fiber reinforced polymer composite(GFRP) clapping plate as a substitute for steel clapping plate. Absorption and load test were conducted to evaluate the decrease in durability of GFRP clapping plate exposed to deterioration environments. In the durability test results, the absorption rate of GFRP clapping plate was appeared as 0.6~1.0% in 50 day of immersion time. Also, the fracture load decreased with accelerated degradation environment exposure. Moreover, the absorption rate in GFRP clapping plate increased as degradation progressed, reducing the fracture load.

Crankshaft Bearing Design Adapting Continuous Oil Supply System (연속오일공급 형태의 크랭크샤프트 베어링 설계)

  • Yun Jeong-Eui
    • Tribology and Lubricants
    • /
    • v.20 no.2
    • /
    • pp.84-90
    • /
    • 2004
  • It is very important to improve the durability and reliability of crankshaft because of conflicting demands for lower fuel consumption and higher power output. In this study, for the crankshaft bearing design, analyses were conducted to determine the lubrication characteristics such as oil flow rate, minimum oil film thickness, friction force and increase of oil temperature at main bearing and connecting rod bearing. Additionally, supplied oil pressure and temperature effects on the bearings were simulated to figure out lubrication characteristics on the bearings. Finally the effects of increasing the bearing width and clearance were introduced on the lubrication characteristics.

Zone based Ad Hoc Network Construction Scheme for Local IoT Networks

  • Youn, Joosang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.12
    • /
    • pp.95-100
    • /
    • 2017
  • In this paper, we propose a zone based ad hoc network construction scheme which support ad hoc path between nodes in local IoT networks consisting of IoT devices with the constrained feature, such as low power, the limited transmission rate and low computing capacity. Recently, the various routing protocols have been studied to support ad hoc networking of local IoT environments. This is, because basis RPL protocol is deigned to be used for the connecting service with Internet through gateway, ad hoc path between nodes in local IoT networks is not supported in basis RPL protocol. Thus, in this paper, the proposed routing scheme provides both ad hoc path and Infra path through gateway, supporting basis RPL protocol simultaneously. Through simulation, we show that the proposed routing scheme with zone based path selection scheme improves the performance of the success rate of end-to-end data transmission and the end-to-end delay, compared to basis RPL protocol.