• Title/Summary/Keyword: Conformity test

Search Result 318, Processing Time 0.023 seconds

Development of Mineral Admixture for Concrete Using Spent Coffee Grounds (커피찌꺼기를 활용한 콘크리트 혼화재의 개발)

  • Kim, Sung-Bae;Lee, Jae-Won;Choi, Yoon-Suk
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.3
    • /
    • pp.185-194
    • /
    • 2022
  • Coffee is one of the most consumed beverages in the world and is the second largest traded commodity after petroleum. Due to the great demand of this product, large amounts of waste is generated in the coffee industry, which are toxic and represent serious environmental problems. This study aims to study the possibility of recycling spent coffee grounds (SCG) as a mineral admixture by replacing the cement in the manufacturing of concrete. To recycle the coffee g rounds, the SCG was dried to remove moisture and fired in a kiln at 850 ℃ for 8 hours. Carbonized coffee grounds are produced as coffee grounds ash (CGA) through ball mill grinding. The chemical composition of the prepared coffee grounds ash was investigated using X-ray fluorescence (XFR). According to the chemical composition analysis, the major elements of coffee grounds ash are K2O(51.74 %), CaO(15.92 %), P2O5(14.39 %), MgO(7.74 %) and SO3(6.89 %), with small amounts of F2O3(0.66 %), SiO2(0.59 %) and Al2O3(0.31 %) content. To evaluate quality and mechanical properties, substitutions of 5, 10, and 15 wt.% of coffee grounds ash (CGA) were tested. From the quality test results, the 28-day activity index of CGA5 reached 80 %, and the flow value ratio reached 96 %, which is comparable to the minimum requirement for second-grade FA. From the test results of the mortar, the optimal results have been found in specimens with 5 wt-% coffee grounds ash, showing good mechanical and physical properties.

Study on the sampling inspection method for reliability assurance of lot (로트의 신뢰성 보증 샘플링검사 방식에 대한 연구)

  • Jaiwook Baik
    • Industry Promotion Research
    • /
    • v.8 no.1
    • /
    • pp.111-117
    • /
    • 2023
  • Sampling inspection methods for quality control have been proposed a lot in the industry. However, the sampling inspection method for reliability, which is a quality over time, has been relatively less presented, and there are not many literatures that are clearly summarized. Therefore, this paper focuses on the reliability conformity test to verify that the reliability evaluation scale value of the target is satisfied during the reliability test. To this end, first, we look at the conditions that both consumers and producers can satisfy in terms of the OC curve and find out what sampling methods satisfy the desired level of producer risk and consumer risk. Next, two methods of the reliability sampling methods such as attribute and variable reliability sampling methods are examined. Specifically, the attribute reliability sampling method is a form of sampling plan where n samples are tested for a certain period of T hours and the lot is accepted if the number of failures is less than or equal to a certain number c. On the other hand, the variable reliability sampling method is a form of sampling plan where the lot is accepted if the reliability evaluation scale such as MTBF satisfies a certain standard. Both sampling plans may also use inspection tables.

Evaluating efficiency of Split VMAT plan for prostate cancer radiotherapy involving pelvic lymph nodes (골반 림프선을 포함한 전립선암 치료 시 Split VMAT plan의 유용성 평가)

  • Mun, Jun Ki;Son, Sang Jun;Kim, Dae Ho;Seo, Seok Jin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.145-156
    • /
    • 2015
  • Purpose : The purpose of this study is to evaluate the efficiency of Split VMAT planning(Contouring rectum divided into an upper and a lower for reduce rectum dose) compare to Conventional VMAT planning(Contouring whole rectum) for prostate cancer radiotherapy involving pelvic lymph nodes. Materials and Methods : A total of 9 cases were enrolled. Each case received radiotherapy with Split VMAT planning to the prostate involving pelvic lymph nodes. Treatment was delivered using TrueBeam STX(Varian Medical Systems, USA) and planned on Eclipse(Ver. 10.0.42, Varian, USA), PRO3(Progressive Resolution Optimizer 10.0.28), AAA(Anisotropic Analytic Algorithm Ver. 10.0.28). Lower rectum contour was defined as starting 1cm superior and ending 1cm inferior to the prostate PTV, upper rectum is a part, except lower rectum from the whole rectum. Split VMAT plan parameters consisted of 10MV coplanar $360^{\circ}$ arcs. Each arc had $30^{\circ}$ and $30^{\circ}$ collimator angle, respectively. An SIB(Simultaneous Integrated Boost) treatment prescription was employed delivering 50.4Gy to pelvic lymph nodes and 63~70Gy to the prostate in 28 fractions. $D_{mean}$ of whole rectum on Split VMAT plan was applied for DVC(Dose Volume Constraint) of the whole rectum for Conventional VMAT plan. In addition, all parameters were set to be the same of existing treatment plans. To minimize the dose difference that shows up randomly on optimizing, all plans were optimized and calculated twice respectively using a 0.2cm grid. All plans were normalized to the prostate $PTV_{100%}$ = 90% or 95%. A comparison of $D_{mean}$ of whole rectum, upperr ectum, lower rectum, and bladder, $V_{50%}$ of upper rectum, total MU and H.I.(Homogeneity Index) and C.I.(Conformity Index) of the PTV was used for technique evaluation. All Split VMAT plans were verified by gamma test with portal dosimetry using EPID. Results : Using DVH analysis, a difference between the Conventional and the Split VMAT plans was demonstrated. The Split VMAT plan demonstrated better in the $D_{mean}$ of whole rectum, Up to 134.4 cGy, at least 43.5 cGy, the average difference was 75.6 cGy and in the $D_{mean}$ of upper rectum, Up to 1113.5 cGy, at least 87.2 cGy, the average difference was 550.5 cGy and in the $D_{mean}$ of lower rectum, Up to 100.5 cGy, at least -34.6 cGy, the average difference was 34.3 cGy and in the $D_{mean}$ of bladder, Up to 271 cGy, at least -55.5 cGy, the average difference was 117.8 cGy and in $V_{50%}$ of upper rectum, Up to 63.4%, at least 3.2%, the average difference was 23.2%. There was no significant difference on H.I., and C.I. of the PTV among two plans. The Split VMAT plan is average 77 MU more than another. All IMRT verification gamma test results for the Split VMAT plan passed over 90.0% at 2 mm / 2%. Conclusion : As a result, the Split VMAT plan appeared to be more favorable in most cases than the Conventional VMAT plan for prostate cancer radiotherapy involving pelvic lymph nodes. By using the split VMAT planning technique it was possible to reduce the upper rectum dose, thus reducing whole rectal dose when compared to conventional VMAT planning. Also using the split VMAT planning technique increase the treatment efficiency.

  • PDF

Effects of Limestone Powder and Silica Fume on the Hydration and Pozzolanic Reaction of High-Strength High-Volume GGBFS Blended Cement Mortars (고강도 고함량 고로슬래그 혼합 시멘트 모르터의 수화 및 포졸란 반응에 미치는 석회석 미분말과 실리카퓸의 영향)

  • Jeong, Ji-Yong;Jang, Seung-Yup;Choi, Young-Cheol;Jung, Sang-Hwa;Kim, Sung-Il
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.2
    • /
    • pp.127-136
    • /
    • 2015
  • To evaluate the effects of limestone powder and silica fume on the properties of high-strength high-volume ground granulated blast-furnace slag (GGBFS) blended cement concrete, this study investigated the rheology, strength development, hydration and pozzolanic reaction characteristics, porosity and pore size distribution of high-strength mortars with the water-to-binder ratio of 20, 50 to 80% GGBFS, up to 20% limestone powder, and up to 10% silica fume. According to test results, compared with the Portland cement mixture, the high-volume GGBFS mixture had much higher flow due to the low surface friction of GGBFS particles and higher strength in the early age due to the accelerated cement hydration by increase of free water; however, because of too low water-to-binder ratio and cement content, and lack of calcium hydroxide content, the pozzolanic reactio cannot be activated and the long-term strength development was limited. Limestone powder did not affect the flowability, and also accelerate the early cement hydration. However, because its effect on the acceleration of cement hydration is not greater than that of GGBFS, and it does not have hydraulic reactivity unlikely to GGBFS, compressive strength was reduced proportional to the replacement ratio of limestone powder. Also, silica fume and very fine GGBFS lowered flow and strength by absorbing more free water required for cement hydration. Capillary porosities of GGBFS blended mortars were smaller than that of OPC mortar, but the effect of limestone powder on porosity was not noticeable, and silica fume increased porosity due to low degree of hydration. Nevertheless, it is confirmed that the addition of GGBFS and silica fume increases fine pores.

Comparison and Evaluation of radiotherapy plans by multi leaf collimator types of Linear accelerator (선형가속기의 다엽콜리메이터 형태에 따른 치료계획 비교 평가)

  • Lim, Ji Hye;Chang, Nam Joon;Seok, Jin Yong;Jung, Yun Ju;Won, Hui Su;Jung, Hae Youn;Choi, Byeong Don
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.129-138
    • /
    • 2018
  • Purpose : An aim of this study was to compare the effect of multi leaf collimator(MLC) types for high dimension radiotherapy in treatment sites used clinically. Material and Method : 70 patients with lung cancer, spine cancer, prostate cancer, whole pelvis, head and neck, breast cancer were included in this study. High definition(HD) MLC of TrueBeam STx (Varian Medical system, Palo Alto, CA) and millenium(M) MLC of VitalBeam (Varian Medical system, Palo Alto, CA) were used. Radiotherapy plans were performed for each patient under same treatment goals with Eclipse (Version 13.7, Varian Palo Alto USA, CA). To compare the indicators of the radiotherapy plans, planning target volume(PTV) coverage, conformity index(CI), homogeneity index(HI), and clinical indicators for each treatment sites in normal tissues were evaluated. To evaluate low dose distribution, $V_{30%}$ values were compared according to MLC types. Additionally, length and volume of targets for each treatment sites were investigated. Result : In stereotatictic body radiotherapy(SBRT) plan for lung, the average value of PTV coverage was reduced by 0.52 % with HD MLC. With SBRT plan using HD MLC for spine, the average value of PTV coverage decreased by 0.63 % and maximum dose decreased by 1.13 %. In the test of CI and HI, the values in SBRT plan with HD MLC for spine were 1.144, 1.079 and the values using M MLC were 1.160, 1.092 in SBRT plan for lung, The dose evaluation of critical organ was reduced by 1.48 % in the ipsilateral lung mean dose with HD MLC. In prostate cancer volumetric modulated arc therapy(VMAT) with HD MLC, the mean dose and the $V_{30}$ of bladder and the mean dose and the $V_{25}$ of rectum were reduced by 0.53 %, 1.42 %, 0.97 %, and 0.69 %, respectively (p<0.05). The average value of heart mean dose was reduced by 0.83 % in breast cancer VMAT with M MLC. Other assessment indices for treatment sites showed no significant difference between treatment plans with two types of MLC. Conclusion : Using HD MLC had a positive impact on the PTV coverage and normal tissue sparing in usually short or small targets such as lung and spine SBRT and prostate VMAT. But, there was no significant difference in targets with long and large such as lung, head and neck, and whole pelvis for VMAT.

  • PDF

Comparative evaluation of dose according to changes in rectal gas volume during radiation therapy for cervical cancer : Phantom Study (자궁경부암 방사선치료 시 직장가스 용적 변화에 따른 선량 비교 평가 - Phantom Study)

  • Choi, So Young;Kim, Tae Won;Kim, Min Su;Song, Heung Kwon;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.89-97
    • /
    • 2021
  • Purpose: The purpose of this study is to compare and evaluate the dose change according to the gas volume variations in the rectum, which was not included in the treatment plan during radiation therapy for cervical cancer. Materials and methods: Static Intensity Modulated Radiation Therapy (S-IMRT) using a 9-field and Volumetric Modulated Arc Therapy (VMAT) using 2 full-arcs were established with treatment planning system on Computed Tomography images of a human phantom. Random gas parameters were included in the Planning Target Volume(PTV) with a maximum change of 2.0 cm in increments of 0.5 cm. Then, the Conformity Index (CI), Homogeneity Index (HI) and PTV Dmax for the target volume were calculated, and the minimum dose (Dmin), mean dose (Dmean) and Maximum Dose (Dmax) were calculated and compared for OAR(organs at risk). For statistical analysis, T-test was performed to obtain a p-value, where the significance level was set to 0.05. Result: The HI coefficients of determination(R2) of S-IMRT and VMAT were 0.9423 and 0.8223, respectively, indicating a relatively clear correlation, and PTV Dmax was found to increase up to 2.8% as the volume of a given gas parameter increased. In case of OAR evaluation, the dose in the bladder did not change with gas volume while a significant dose difference of more than Dmean 700 cGy was confirmed in rectum using both treatment plans at gas volumes of 1.0 cm or more. In all values except for Dmean of bladder, p-value was less than 0.05, confirming a statistically significant difference. Conclusion: In the case of gas generation not considered in the reference treatment plan, as the amount of gas increased, the dose difference at PTV and the dose delivered to the rectum increased. Therefore, during radiation therapy, it is necessary to make efforts to minimize the dose transmission error caused by a large amount of gas volumes in the rectum. Further studies will be necessary to evaluate dose transmission by not only varying the gas volume but also where the gas was located in the treatment field.

An Experimental Study on the Residual Compressive Strength of PCM Depending on Temperature Variations (온도변화에 따른 폴리머 시멘트 모르타르의 잔존압축강도 특성에 관한 실험적 연구)

  • Seo, Dong-Goo;Koo, In-Hyuk;Yoon, Ung-Gi;Kim, Bong-Chan;Kim, Hyung-Jun;Kwon, Young-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.5
    • /
    • pp.483-489
    • /
    • 2015
  • The Purpose of this study was to establish the basic data on the mechanical properties of PCM in the high temperature range. To this end, an experiment was conducted on the characteristics of the residual compressive strength by temperature (100, 200, 400 and $600^{\circ}C$) with a fixed temperature heating. An after heating test was performed to investigate the properties after fire damage. The result showed that the residual compressive strength of PCM had a tendency to decrease, regardless of the type of polymer. It was also found that when the contents were low, the residual compressive strength started to greatly decrease from the high temperature range of $400^{\circ}C$, and that the specimen containing PAE showed a steeper slope than the specimen containing EVA. However, since little studies have been conducted on the mechanical properties of PCM with the high temperature, it is considered that, in addition to this study, basic studies must be preceded, including studies on the repairing methods.

CHARACTERISTICS OF UNRULY & DELINQUENT ADOLESCENTS ADMITTED TO A PSYCHIATRIC INPATIENT UNIT (청소년 병동에 입원한 비행 청소년의 특성에 관한 연구)

  • Lee, Young-Sik;Kim, Wun-Jung;Carey, Michael
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.8 no.1
    • /
    • pp.70-82
    • /
    • 1997
  • Objective:This study was performed to identify and understand the characteristics of adolescents who had a history of police arrest and/or were adjudicated unruly/delinquent by the juvenile court. Method:The study employed a retrospective reivew of coumputer-recorded data set on 210 consecutive admissions to an adolescent psychiatric inpatient unit. Three groups(No Police Contact, N=115;Police Contact Only, N=60;Adjudicated, N=35) were compared on the areas of a) cognitive and educational performance b) emotion:anxiety, depression, suicidality c) personality d) family and life experiences. Standardized assessments were administered to all subjects using WISC-Ⅲ, Kaufman Test of Educational Achievement, Millon Adolescent Personality Inventory, Reynolds Adolescent Depression Scale, Revised-Chilren’s Manifest Anxiety Scale, Suicide Ideation Questionnarie, Suicide Behavior Interive, Life Events Checklist, and Family Environmental Scale. A subgroup of the subjects, 60 cases also received a standardized interview by Child Assessment Schedule. Results:The characteristic findings of the delinquent group(the police contact only and adjudicated subjects combined) included (1) a high rate of adoption, sexual promiscuity, out of home placement, and repeated psychiatric hospitalization, (2) low verbal IQ scores and educational achievements, (3) high impulsivity, low social conformity, and high forcefulness in personality inventory, (4) low activityrecreation orientation and low moral religious emphasis in family environment, (5)a high frequency of adverse life experiences, (6) among 3 groups, the Police Contact Only group showed the lowest depression, anxiety and suicidal ideation scores, (7) a high diagnostic frequency of conduct disorder, ODD, and ADHD. Conclusions:The adolescent psychiatric inpatients with a delinquent history presented with a certain clinical, family, psychometric characteristics that warrant specific clinical intervention strategies for their cognitive deficits, an impulsive personality style, family dysfunction with adverse life experiences and disruptive behavioral disorders, different from the rest of adolescent psychiatric inpatients.

  • PDF

Nation-wide Interoperable Transportation Card K-CASH System Development (전국호환 교통카드 K-CASH 시스템 개발)

  • Lee, Ki-Han;Kim, Hye-Hyeon;Kim, Tae-Hee;Maeng, Jae-Hwan;Park, Ha-Na
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.4
    • /
    • pp.102-112
    • /
    • 2010
  • The existing K-CASH system doesn't allow compatible between different regions, different public transportations and the technologies made by different operators. If a K-cash user wants to use public transportation charged not by K-CASH but other operator, then he or she would have to get other type of card available for that transportation. Also, the incompatibility of the existing K-CASH might cause unnecessary expense because similar systems would have to be doubly constructed if the K-CASH operator would like to install the K-CASH system on the same infra as the other operators already did. As a result, a system which allows people to use just one card for their convenience regardless of regions, types of transportation and operators has been strongly demanded. In this paper, we developed Nation-wide Interoperable K-Cash system, Nation-wide Interoperable K-CASH Card, Purchase terminal, Purchase SAM and Settlement system that were updated from the existing K-CASH system. And we performed a conformity test to confirm performance. Also Korea Financial Telecommunications & Clearings and the KORAIL NETWARKS and the HiPlusCard joined for the testbed in Gwangju for 6 months. This result of testbed finally proved that the Nation-wide Interoperable K-CASH system is completely compatible.

Development of the Fixed Slab Analogy Device for the Measurement of Stress Intensity Factor (응력확대계수 측정용 고정 슬랩상사 장치의 개발)

  • 정진석;최선호;황재석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.1999-2010
    • /
    • 1992
  • The fixed slab analogy device which can measure stress intensity factors(S.I.F) experimentally by slab analogy theory is developed in this paper. The margin of errors resulted from the new testing apparatus are between 0.02% and 8.25%. Therefore, it is assured that this one can be effectively used for the more accurate measurement of S.I.F.( $k_{I}$, $k_{I I}$) than conventional apparatus. The pitch of master grating used in this experiment is 0.1mm It is known that the ratio of the distance from crack tip to the crack length on obtaining the accurate stress intensity factor is between 0.4 and 0.7. The optimum curvature radius of slab is about 125mm. The thickness of slab(plate) used in the fixed slab analogy device is 0.05mm(P.V.C. ; E = 64 MN/ $m^{2}$, .nu.=0.38), which is proved to be suitable for the test. The optimum material for the frame(slab`s external boundary) is a alloy tool steel(SKS 5) plate and its thickness is 1mm. In this research, the rigid cracks are directly bonded to the slab surface by cyanoacrylate adhesive for the easiness of slab making and conformity to the practical crack figure. The material of rigid crack is thin steel plate. It is expected that the developed method can be used effectively for the analysis of $k_{I}$ and $k_{I I}$ of arbitrary shaped or distributed cracks.cks.