폐암의 SABR(Stereotactic Ablative Radiotherapy)시 복부압박(Abdominal compression)과 CPAP(Continuous Positive Air Pressure)를 이용한 치료계획의 비교 및 평가 (Comparison and evaluation of treatment plans using Abdominal compression and Continuous Positive Air Pressure for lung cancer SABR)

  • 김대호;손상준;문준기;박장필;이제희
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.35-46
    • /
    • 2021
  • 목 적 : 폐암의 정위 절제 방사선 치료(Stereotactic Ablative Radiation Therapy, SABR)시 복부압박을 이용한 치료계획과 양압지속유지기(The Continuous Positive Air Pressure, CPAP)를 이용한 치료계획을 비교, 분석하여 방사선 치료 효과 향상에 기여하고자 한다. 대상 및 방법 : 본원의 폐의 SABR 환자 중 2명을 대상으로 복부 압박 고정 장치(the Body Pro-Lok, BPL)와 CPAP를 이용한 치료 계획을 수립하여, RTOG 0813에서 제안한 parameter들과 균질도(Homogeneity Index, HI), 일치도(Conformity Index, CI)를 통해 치료계획을 분석하였다. 또한 모든 4D CT에서 각 Phase별 계획용 표적 체적(Planning Target Volume, PTV) 중심의 X, Y, Z축 움직임을 분석하고, PTV와 손상위험장기(Organ At Risk, OAR)의 체적과 평균 선량을 구하여 비교하였다. 그리고 4개의 원뿔형빔 전산화단층촬영(Cone Beam Computed Tomography, CBCT)을 이용하여, PTV 중심점과 0°, 90°, 180°, 270° 중 세 방향에서의 흉강내 접점까지의 직선거리를 측정하고, 각 방향에서 평균거리 값과의 차이를 비교하였다. 결 과 : BPL과 CPAP를 사용하여 얻은 치료계획은 모두 RTOG의 권고값을 따랐으며, 균질도와 일치도에서도 큰 차이가 없었다. PTV 중심의 X축, Y축, Z축 움직임은 A 환자의 경우 BPL 사용시 0.49 cm, 0.37 cm, 1.66 cm, CPAP 사용시 0.16 cm, 0.12 cm, 0.19 cm을 보였고, B 환자의 경우 BPL 사용시 0.22 cm, 0.18 cm, 1.03 cm, CPAP 사용시 0.14 cm, 0.11 cm, 0.4 cm을 보였다. CPAP 사용시 BPL 사용시보다 A 환자의 경우 ITV가 46.27% 감소하였고 좌측 폐의 체적이 41.94% 증가하였으며, 평균선량은 심장에서 52.81% 감소하였다. B 환자의 경우 좌측 폐 106.89%, 우측 폐 87.32% 체적이 증가하였고, 평균선량은 위에서 44.30% 감소하였다. 각 방향의 직선거리 값과 평균거리 값과의 최대 차이는 A 환자의 경우 a방향에서 0.05 cm, b방향에서 0.05 cm, c방향에서 0.41 cm 났고, B 환자의 경우 d방향에서 0.19 cm, e방향에서 0.49 cm, f방향에서 0.06 cm 차이가 났다. 결 론 : CPAP 사용시 폐용적의 증가를 통해 표적 근처 OAR의 선량을 BPL 사용시보다 더 효과적으로 감소시킬 수 있으며, 호흡에 따른 종양의 움직임 제한에도 더 효과적으로 기여할 수 있다는 것을 확인하였다. 추후 CPAP의 다양한 부위 적용과 다른 치료기와의 결합을 통해 방사선 치료 효과를 개선시킬 수 있을 것으로 사료된다.

유방암 세기조절방사선치료에서의 호흡운동 영향 (Impact of Respiratory Motion on Breast Cancer Intensity-modulated Radiation Therapy)

  • 정원규;정미주;신동오;김동욱
    • 한국의학물리학회지:의학물리
    • /
    • 제27권2호
    • /
    • pp.93-97
    • /
    • 2016
  • 유방암 환자에 대한 세기조절방사선치료(IMRT)를 수행함에 있어서 환자의 호흡이 계획표적부피(PTV) 내의 선량분포에 미치는 영향을 평가하고 그 영향을 감소시킬 수 있는 방안에 대해 연구를 수행하였다. 이에 따라 호흡위상별 전산화단층 촬영술(4DCT) 영상을 획득하여 IMRT 치료계획에 적용하고 호흡위상 30%와 60%, 90%에서 PTV에 조사된 선량분포와 선량균질지수(HI), 덮힘율지수(CVI), 처방선량지수(CI)를 선량-부피히스토그램(DVH)을 이용하여 비교하였다. 또한 치료 부위의 피부에 조직보상체와 가상계획표적부피 설정을 통하여 유방암 IMRT중에 발생할 수 있는 호흡운동에 의한 부작용 감소 효과를 평가해 보았다. 조직보상체를 사용하지 않는 경우에 HI가 2배 증가하고 CVI는 상대적으로 감소하였으나 조직 보상체와 가상계획표적부피를 사용한 경우에는 환자의 호흡에 따른 표적부피 선량 변화가 상대적으로 크지 않게 평가되었다. 따라서 유방암 환자의 대한 IMRT 치료에서의 정밀도 향상을 위하여 조직보상체 및 가상계획표적부피 사용이 한가지 방안이 될 수 있을 것으로 사료된다.

식도암 세기조절방사선치료와 용적세기조절회전치료에 대한 Jaw-Tracking의 유용성 평가 (Effectiveness Assessment on Jaw-Tracking in Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy for Esophageal Cancer)

  • 오현택;유순미;전수동;김민수;송흥권;윤인하;백금문
    • 대한방사선치료학회지
    • /
    • 제31권1호
    • /
    • pp.33-41
    • /
    • 2019
  • 목 적: 식도암 방사선치료 시 세기조절방사선치료(Intensity Modulated Radiation Therapy, IMRT) 및 용적세기조절회전치료(Volumetric Modulated Arc Therapy, VMAT)에서 Jaw-Tracking 기법 유 무에 따라 저선량 영역에 대한 주변 정상장기의 용적선량을 분석하여 그 유용성을 평가하고자 한다. 대상 및 방법: 본 원에서 사용하고 있는 선형가속기 VitalBeamTM(Varian Medical System, U.S.A)으로 식도암 방사선치료를 받은 27명을 대상으로 하였으며, 치료계획은 Eclipse(Ver. 13.6 Varian, U.S.A)를 이용하여 Jaw-Tracking(JT)을 사용한 치료계획과 Non Jaw-Tracking(NJT) 치료계획을 수립하였으며, 치료계획용적(Planning Target Volume, PTV)에 빗장위림프절(Supraclavicular Lymph Nodes, SCL)이 포함되어 있는 T자형 PTV를 가진 환자를 대상으로 하였다. 조사범위에 대한 영향을 확인하기 위해 복강(Celiac) 포함 여부로 비교군을 나누었다. 수립된 치료계획의 비교를 위해 손상위험장기는 양측 폐, 심장, 척수를 비교하였으며 Conformity Index(CI), Homogeneity Index(HI)를 비교하였다. 임상적용 검증을 위해 전자포탈영상장치(Electronic Portal Imaging Device, EPID)를 이용하여 Portal Dosimetry를 실시하였고, 선량 영역의 임계치(Threshold)를 10 %, 5 %, 0 %로 매개변수로 설정하여 감마분석을 실시하였다. 결 과: 모든 치료계획은 3 mm / 3 %, 감마통과율 95 % 기준에 대해 Threshold 10 %의 경우 95 % 이상으로 JT, NJT 모두 통과하였으며, IMRT는 Threshold가 5 %, 0 %로 줄어들수록 JT보다 NJT의 값이 1 % 이상 줄어 들었다. IMRT에서 양측 폐의 $V_5$$V_{10}$은 JT에서 Celiac을 포함하지 않을 때 최대 14.7 %, 평균 8.5 %, 5.3 % 만큼 감소했고, $D_{mean}$$72.3{\pm}51cGy$ 감소하였으며, Celiac을 포함할 때 JT에서 선량감소가 증가하였다. 심장의 $D_{mean}$$68.9{\pm}38.5cGy$, 척수의 $D_{max}$$39.7{\pm]30.1cGy$만큼 감소하였다. VMAT은 JT기법 사용 시 폐에서 $V_5$ 평균 2.5 % 감소하였고, 심장 및 척수에서 소량 감소하였으며, Celiac 포함 시 JT의 선량감소가 증가하였다. 결 론: 식도암 치료계획에서 IMRT가 JT 사용 시 양측 폐의 $V_5$, $V_{10}$에서 유의미한 감소가 나타났고, 저 선량영역에서 조사범위가 클수록 선량감소가 크게 나타났다. 따라서 식도암 방사선치료에는 IMRT가 VMAT보다 JT 적용 시 더 효과적이며, 저 선량영역에서의 MLC 누설 및 투과선량으로부터 정상장기를 보호할 수 있다.

Adjuvant Radiotherapy after Breast Conserving Treatment for Breast Cancer:A Dosimetric Comparison between Volumetric Modulated Arc Therapy and Intensity Modulated Radiotherapy

  • Liu, Zhe-Ming;Ge, Xiao-Lin;Chen, Jia-Yan;Wang, Pei-Pei;Zhang, Chi;Yang, Xi;Zhu, Hong-Cheng;Liu, Jia;Qin, Qin;Xu, Li-Ping;Lu, Jing;Zhan, Liang-Liang;Cheng, Hong-Yan;Sun, Xin-Chen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권8호
    • /
    • pp.3257-3265
    • /
    • 2015
  • Background: Radiotherapy is an important treatment of choice for breast cancer patients after breast-conserving surgery, and we compare the feasibility of using dual arc volumetric modulated arc therapy (VMAT2), single arc volumetric modulated arc therapy (VMAT1) and Multi-beam Intensity Modulated Radiotherapy (M-IMRT) on patients after breast-conserving surgery. Materials and Methods: Thirty patients with breast cancer (half right-sided and half left-sided) treated by conservative lumpectomy and requiring whole breast radiotherapy with tumor bed boost were planned with three different radiotherapy techniques: 1) VMAT1; 2) VMAT2; 3) M-IMRT. The distributions for the planning target volume (PTV) and organs at risk (OARs) were compared. Dosimetries for all the techniques were compared. Results: All three techniques satisfied the dose constraint well. VMAT2 showed no obvious difference in the homogeneity index (HI) and conformity index (CI) of the PTV with respect to M-IMRT and VMAT1. VMAT2 clearly improved the treatment efficiency and can also decrease the mean dose and V5Gy of the contralateral lung. The mean dose and maximum dose of the spinal cord and contralateral breast were lower for VMAT2 than the other two techniques. The very low dose distribution (V1Gy) of the contralateral breast also showed great reduction in VMAT2 compared with the other two techniques. For the ipsilateral lung of right-sided breast cancer, the mean dose was decreased significantly in VMAT2 compared with VMAT1 and M-IMRT. The V20Gy and V30Gy of the ipsilateral lung of the left-sided breast cancer for VMAT2 showed obvious reduction compared with the other two techniques. The heart statistics of VMAT2 also decreased considerably compared to VMAT1 and M-IMRT. Conclusions: Compared to the other two techniques, the dual arc volumetric modulated arc therapy technique reduced radiation dose exposure to the organs at risk and maintained a reasonable target dose distribution.

전 이성 뇌 암의 정위 방사선수술에서 Couch 회전에 따른 VMAT의 선량 정확성 평가 (Evaluation of VMAT Dose Accuracy According to Couch Rotation in Stereotactic Radiation Surgery of Metastatic Brain Cancer)

  • 나귀금;박병석;차우정;박용철
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.117-125
    • /
    • 2021
  • 목 적: 본 연구는 뇌 정위 방사선수술에서 비 동일 면빔 사용 시 couch 회전에 따른 Set-up 오차에 대한 상관관계를 알아보고 선량 학적 차이 평가를 통해 치료 용적의 추가적인 margin 설정을 제안하고자 한다. 대상 및 방법: 4개의 Arc beam을 사용하였으며 전체 beam 중에 non coplanar beam의 빈도 수를 달리하는 각각의 시나리오 치료 계획을 만들었다. 이후 couch를 회전한 후 Exact system을 이용하여 couch Setup 오차 값을 측정하였다. 이를 적용하여 재 치료 계획을 만들어 선량적 정확성을 평가하였다. 결 과 : Couch가 30°, 45°, 60°, 90°로 회전하였을 시 X축 이동 값의 평균은 각 0.29 mm, 0.26 mm, 0.51 mm, 0.08 mm으로 측정되었다. Y축 이동 값의 평균은 각 0.75 mm, 0.5mm, 0.35 mm, 0.29 mm 으로 측정되었다. Z축 이동 값의 평균은 각 0.5 mm, 0.28 mm, 0.22 mm, 0.1 mm으로 측정되었다. 선량 학적 결과로는 1-NC VMAT, 2-NC VMAT, 3-NC VMAT 모두 각 initial plan 대비 D99에서 0.1%, 3.1%, 1.9% 선량 감소하였고 1-NC VMAT의 GTV의 CI(Conformity Index)는 0.8이며 2-NC VMAT는 0.79, 3-NC VMAT는 0.75이다. 결 론 : NC-VMAT의 뇌 정위 방사선수술 시 전체 beam의 개수 중 50% 이상의 non coplanar beam을 사용하여 치료하는 경우 couch 회전 시 image verification 이 각각 필요하다. 그러나 선형가속기 장비 특성상 couch가 회전된 상태에서 image verification이 가능하지 않다면 GTV에 couch 회전으로 인한 최대 오차 값을 포함하는 1.5 mm margin을 추가하여 치료 계획을 수립하는 것이 유용할 것으로 사료된다.

좌측 유방암의 방사선치료 자세와 선량인자의 상관관계 분석 (Correlation analysis of radiation therapy position and dose factors for left breast cancer)

  • 전재완;박철우;홍종수;진성진;강정훈
    • 대한방사선치료학회지
    • /
    • 제29권1호
    • /
    • pp.37-48
    • /
    • 2017
  • 목 적: 방사선치료의 가장 기본적인 조건은 정상조직의 불필요한 피폭을 방지하는 것이다. 유방암의 경우는 폐와 심장에 조사되는 선량이 중요하게 평가되는 인자이다. 따라서 유방암 방사선치료 자세에 따른 정상조직에 조사되는 선량을 비교하고 그 연관성을 상관관계 분석을 통하여 결과를 확인하여 보다 효과적인 유방암 방사선 치료방법을 모색하고자 한다. 대상 및 방법: 본원을 내원한 좌측 유방암 환자 30명을 대상으로 Supine, Prone Position에서 CT image를 획득하였다. Eclipse Treatment Planning System(Version 11, USA)을 이용하여 전산화치료계획을 수립하였다. DVH(Dose Volume Histogram)을 통해 Position 별로 정상조직에 조사된 선량을 비교하였다. 그 결과를 바탕으로 SPSS(Version 18)을 이용하여 각 정상조직의 선량인자를 통계분석하고 항목 간 상관관계 분석 및 독립표본 t-test를 통하여 그 연관성을 알아보았다. 그리고 MIRADA RTx(Version Advanced 1.6, UK)를 이용하여 HI(Homogeneity Index)와 CI(Conformity Index)를 Supine, Prone Position에서 값을 구하고 비교하였다. 결 과: 유방암의 전산화치료계획의 결과 폐의 경우는 Supine Position에서 V20은 $16.5{\pm}2.6%$, V30은 $13.8{\pm}2.2%$, Mean dose는 $779.1{\pm}135.9cGy$(Absolute value)를 보였다. Prone Position은 위 순서대로 $3.1{\pm}2.2%$, $1.8{\pm}1.7%$, $241.4{\pm}138.3cGy$를 보였다. Prone Position이 전반적으로 낮은 선량을 나타내었고 평균선량 537.7 cGy가 더 적게 폐에 조사되었다. 심장의 경우에는 Supine, Prone 순서대로 V30은 $8.1{\pm}2.6%$, $5.1{\pm}2.5%$, Mean dose는 $594.9{\pm}225.3cGy$, $408{\pm}183.6cGy$를 보였다. Prone Position에서 평균선량 182.6 cGy가 더 적게 조사된다는 것을 확인하였다. 통계분석 결과 신뢰도 분석지표인 Cronbach's Alpha value는 0.563이였고 변수간의 상관관계분석 결과 치료자세와 폐의 선량평가인자는 대략 0.89 이상으로 그 상관관계가 높았다. 반면 심장의 경우는 V30은 0.488, Mean dose는 0.418로 상관관계가 다소 적었다. 마지막으로 독립표본 t-test 결과 치료자세와 폐, 심장의 선량평가인자가 신뢰수준 99 %에서 모두 유의하게 나타났다($p-value{\leq}0.05$). 결 론: 현재 방사선치료는 최첨단 선형가속기와 다양화된 전산화치료계획 기술이 개발되고 있다. 이 발전의 기본전제 조건은 PTV(Planning Target Volume) 주위의 정상조직 보호라고 생각한다. 물론 유방암 환자를 Prone Position에서 치료하면 Set-up의 재현성 문제와 다소 많은 시간이 소요되지만 이 실험결과에서 보듯이 Prone Position에서 폐와 심장에 들어가는 선량을 줄일 수 있으며 그 연관관계도 의미가 있다는 것을 확인하였다. 결론적으로 Prone Position에서 충분한 치료시간을 확보하고 정확한 치료부위 확인이 이루어진다면 환자에게 보다 좋은 방사선치료를 제공할 수 있다고 생각된다.