• Title/Summary/Keyword: Conformity index (CI)

Search Result 66, Processing Time 0.022 seconds

Clinical Analysis of Inverse Planning for Radiosurgery ; Gamma Knife Treatment Plan Study (방사선 수술 역방향 치료계획 유용성 평가)

  • Jin, Seong Jin;Je, Jae Yong;Park, Cheol Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.343-348
    • /
    • 2015
  • The purpose of this study is a comparison of forward planning(FP) and inverse planning(IP) of a radiosurgery procedure. 10 patients of acoustic schwannoma MR image were used for treatment plan. FP-1,2 and IP were established under the same condition. FP and IP were compared by number of shot, conformity index(CI), paddic conformity index(PCI), gradiant index(GI) and treatment time. On average the treatment plan produced by IP tool provided an improved or similar CI, PCI, GI and reduced treatment time as compared to the FP (CI;FP-1:0.85, FP-2:0.86, IP:0.94, PCI;FP-1:0.79, FP-2:0.81, IP:0.78, GI;FP-1:2.94, FP-2:2.94, IP:3.01). The inverse planning system provides a clinically useful plan while reducing the planning time and treatment time.

The comparison of treatment planning between stereotactic radiosurgery planning systems (정위방사선수술 치료계획시스템간의 치료계획비교)

  • 김기환;조문준;김재성;김준상;신교철;김진기;오영기;정동혁;김정기
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.171-175
    • /
    • 2001
  • We analyze the relation of dose volume histogram, conformity index and homogeneity index based on RTOG9005 for treatment planning result between framed based stereotactic radiosurgery(SRS) system and frameless SRS/T system to verify the difference of two systems in the intracranial target. There is same treatment planning result by two treatment planning systems.

  • PDF

Dosimetric Comparison of Three Dimensional Conformal Radiation Radiotherapy and Helical Tomotherapy Partial Breast Cancer (유방암 환자의 3D-CRT, TOMO 방법에 따른 선량 분포 평가)

  • Kim, Dae-Woong;Kim, Jong-Won;Choi, Yun-Kyeong;Kim, Jung-Soo;Hwang, Jae-Woong;Jeong, Kyeong-Sik;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.11-15
    • /
    • 2008
  • Purpose: The goal of radiation treatment is to deliver a prescribed radiation dose to the target volume accurately while minimizing dose to normal tissues. In this paper, we comparing the dose distribution between three dimensional conformal radiation radiotherapy (3D-CRT) and helical tomotherapy (TOMO) plan for partial breast cancer. Materials and Methods: Twenty patients were included in the study, and plans for two techniques were developed for each patient (left breast:10 patients, right breast:10 patients). For each patient 3D-CRT planning was using pinnacle planning system, inverse plan was made using Tomotherapy Hi-Art system and using the same targets and optimization goals. We comparing the Homogeneity index (HI), Conformity index (CI) and sparing of the organs at risk for dose-volume histogram. Results: Whereas the HI, CI of TOMO was significantly better than the other, 3D-CRT was observed to have significantly poorer HI, CI. The percentage ipsilateral non-PTV breast volume that was delivered 50% of the prescribed dose was 3D-CRT (mean: 40.4%), TOMO (mean: 18.3%). The average ipsilateral lung volume percentage receiving 20% of the PD was 3D-CRT (mean: 4.8%), TOMO (mean: 14.2), concerning the average heart volume receiving 20% and 10% of the PD during treatment of left breast cancer 3D-CRT (mean: 1.6%, 3.0%), TOMO (mean: 9.7%, 26.3%) Conclusion: In summary, 3D-CRT and TOMO techniques were found to have acceptable PTV coverage in our study. However, in TOMO, high conformity to the PTV and effective breast tissue sparing was achieved at the expense of considerable dose exposure to the lung and heart.

  • PDF

A Study on the Relationship of Change of Mechanical Properties and Carbonyl Index Induced through Short-wavelength Ultraviolet Radiation (254 nm) for High Density Polyethylene (단파장 자외선(254 nm)에 노출된 고밀도 폴리에틸렌 수지의 카르보닐 지수(CI)와 기계적 물성 변화의 관계에 관한 연구)

  • Kim, Chang-Hwan;Shin, Jin-Yong
    • Applied Chemistry for Engineering
    • /
    • v.24 no.2
    • /
    • pp.138-143
    • /
    • 2013
  • This paper studied the possibility to predict a mechanical property variation from changes in created carbonyl bands by irradiating the surface of high-density polyethylene with short-wavelength ultraviolet radiation of 254 nm to induce a fast chemical degradation. The meaning of this study lies in checking whether a mechanical property change with the same chemical property as the induced optical deterioration is caused by using a UVC lamp with high photon energy instead of optical deterioration via xenon arc light source and outdoor exposure test via natural sunlight requiring a long time. The mechanical strength of high-density polyethylene checked by a tensile test and a creep destruction test showed a similar tendency with CI changes. In particular, the yield strength and elongation had a close relationship with the exposure time to ultraviolet radiation. Accordingly, this paper presented a method to grasp the mechanical property change outdoors requiring a long time more fast through the relationship between the mechanical property change and the carbonyl index using a UVC lamp causing the fast surface degradation.

Variation of optimization techniques for high dose rate brachytherapy in cervical cancer treatment

  • Azahari, Ahmad Naqiuddin;Ghani, Ahmad Tirmizi;Abdullah, Reduan;Jayamani, Jayapramila;Appalanaido, Gokula Kumar;Jalil, Jasmin;Aziz, Mohd Zahri Abdul
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1414-1420
    • /
    • 2022
  • High dose rate (HDR) brachytherapy treatment planning usually involves optimization methods to deliver uniform dose to the target volume and minimize dose to the healthy tissues. Four optimizations were used to evaluate the high-risk clinical target volume (HRCTV) coverage and organ at risk (OAR). Dose-volume histogram (DVH) and dosimetric parameters were analyzed and evaluated. Better coverage was achieved with PGO (mean CI = 0.95), but there were no significant mean CI differences than GrO (p = 0.03322). Mean EQD2 doses to HRCTV (D90) were also superior for PGO with no significant mean EQD2 doses than GrO (p = 0.9410). The mean EQD2 doses to bladder, rectum, and sigmoid were significantly higher for NO plan than PO, GrO, and PGO. PO significantly reduced the mean EQD2 doses to bladder, rectum, and sigmoid but compromising the conformity index to HRCTV. PGO was superior in conformity index (CI) and mean EQD2 doses to HRCTV compared with the GrO plan but not statistically significant. The mean EQD2 doses to the rectum by PGO plan slightly exceeded the limit from ABS recommendation (mean EQD2 dose = 78.08 Gy EQD2). However, PGO can shorten the treatment planning process without compromising the CI and keeping the OARs dose below the tolerance limit.

Comparing the dosimetric impact of fiducial marker according to density override method : Planning study (양성자 치료계획에서 fiducial marker의 density override 방법에 따른 선량변화 비교 : Planning study)

  • Sung, Doo Young;Park, Seyjoon;Park, Ji Hyun;Park, Yong Chul;Park, Hee Chul;Choi, Byoung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.19-26
    • /
    • 2017
  • Purpose: The application of density override is very important to minimize dose calculation errors by fiducial markers of metal material in proton treatment plan. However, density override with actual material of the fiducial marker could make problem such as inaccurate target contouring and compensator fabrication. Therefore, we perform density override with surrounding material instead of actual material and we intend to evaluate the usefulness of density override with surrounding material of the fiducial marker by analyzing the dose distribution according to the position, material of the fiducial marker and number of beams. Materials and Method: We supposed that the fiducial marker of gold, steel, titanium is located in 1.5, 2.5, 4.0, 6.0 cm from the proton beam's end of range using water phantom. Treatment plans were created by applying density override with the surrounding material and actual material of the fiducial marker. Also, a liver cancer patient who received proton therapy was selected. We located the fiducial marker of gold, steel, titanium in 0, 1.5, 3.5 cm from the proton beam's end of range and the treatment plans were created by same method with water phantom. Homogeneity Index(HI), Conformity Index(CI) and maximum dose of Organ At Risk(OAR) in Planning Target Volume(PTV) as the evaluation index were compared according to the material, position of the fiducial marker and number of beam. Results: The HI value was more decreased when density override with surrounding material of the fiducial marker was performed comparing with density override with actual material. Especially the HI value was increased when the fiducial marker was located farther from the proton beam's end of the range for a single beam and the fiducial marker's position was closer to isocenter for two or more beams. The CI value was close to 1 and OAR maximum dose was greatly reduced when density override with surrounding material of the fiducial marker was performed comparing with density override with actual material. Conclusion: Density override with surrounding material can be expected to achieve more precise proton therapy than density override with actual material of the fiducial marker and could increase the dose uniformity and target coverage and reduce the dose to surrounding normal tissues for the small fiducial markers used in clinical practice. Most of all, it is desirable to plan the treatment by avoiding the fiducial marker of metal material as much as possible. However, if the fiducial marker have on the beam path, density override of the surrounding material can be expected to achieve more precise proton therapy.

  • PDF

Evaluation of Dose Volume and Radiobiological Indices by the Dose Calculation Grid Size in Nasopharyngeal Cancer VMAT (비 인두암 체적 조절 호형 방사선 치료의 선량 계산 격자 크기에 따른 선량 체적 지수와 방사선 생물학적 지수의 평가)

  • Kang, Dong-Jin;Jung, Jae-Yong;Shin, Young-Joo;Min, Jung-Whan;Shim, Jae-Goo;Park, So-Hyun
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.265-272
    • /
    • 2020
  • The purpose of this study was to investigate the dose-volume indices and radiobiological indices according to the change in dose calculation grid size during the planning of nasopharyngeal cancer VMAT treatment. After performing the VMAT treatment plan using the 3.0 mm dose calculation grid size, dose calculation from 1.0 mm to 5.0 mm was performed repeatedly to obtain a dose volume histogram. The dose volume index and radiobiological index were evaluated using the obtained dose volume histogram. The smaller the dose calculation grid size, the smaller the mean dose for CTV and the larger the mean dose for PTV. For OAR of spinal cord, brain stem, lens and parotid gland, the mean dose did not show a significant difference according to the change in dose calculation grid size. The smaller the grid size, the higher the conformity of the dose distribution as the CI of the PTV increases. The CI and HI showed the best results at 3.0 mm. The smaller the dose calculation grid size, the higher the TCP of the PTV. The smaller the dose calculation grid size, the lower the NTCP of lens and parotid. As a result, when performing the nasopharynx cancer VMAT plan, it was found that the dose calculation grid size should be determined in consideration of dose volume index, radiobiological index, and dose calculation time. According to the results of various experiments, it was determined that it is desirable to apply a grid size of 2.0 - 3.0 mm.

A Comparative Study of Radiation Therapy Planning between Volumetric-Modulated Arc Therapy and Three-Dimensional Conformal Radiotherapy in Nasopharyngeal Cancer (비인두암의 방사선치료 시 삼차원입체조형 치료기법과 용적세기조절회전치료기법의 비교연구)

  • Kim, Ji-Sung;Lee, Seok-Ho;Lee, Seung-Heon;Kim, Hye-Young;Choi, Jin-Ho;Lee, Kyu-Chan;Kim, Dong-Young
    • Korean Journal of Head & Neck Oncology
    • /
    • v.26 no.2
    • /
    • pp.171-177
    • /
    • 2010
  • 연구목적 : 비인두암 환자들을 대상으로 방사선치료 시 삼차원입체조형치료기법과 용적세기조절회전치료기법을 비교하고 이하선을 포함한 정상조직 보호에 있어 그 차이점을 알아 보고자 본 연구를 시행하였다. 대상 및 방법 : 비인두암 환자 5명을 대상으로 치료계획용 CT(computed tomography)를 시행 후 삼차원입체조형방사선치료계획 과 용적세기조절회전치료계획을 시행하였다. 이를 바탕으로 얻은 선량분포, conformity index(CI) 그리고 선량체적 히스토그램을 통해 손상위험장기(organ at risk)와 계획용표적체적(planning target volume)을 비교 분석하였다. 결 과 : 분석결과 이하선에 조사되는 평균선량이 용적세기조절회전치료계획에서는 43.9%로 삼차원입체조형치료계획에서의 89.4% 보다 유의하게(p=0.043) 감소하였다. 계획용표적체적 conformity index의 경우 용적세기조절회전치료계획 (CI=1.06)에서 삼차원입체조형치료계획(CI=2.55) 보다 유의하게(p=0.043) 향상된 결과를 보였다. 결 론 : 비인두암 환자에서 용적세기조절회전 치료계획 시 삼차원입체조형치료계획 보다 유의하게 이하선에 평균선량이 줄었고 계획용 표적체적에 대한 conformity도 유의하게 향상되는 결과를 보였다. 본 연구가 적은 수의 환자를 대상으로 하였으나 용적세기조절회전치료기법을 시행 시 구강건조증의 발생을 줄일 수 있을 것으로 기대된다. 향후 더 많은 환자군을 대상으로 한 임상연구가 필요할 것으로 사료된다.

Influence of different boost techniques on radiation dose to the left anterior descending coronary artery

  • Park, Kawngwoo;Lee, Yongha;Cha, Jihye;You, Sei Hwan;Kim, Sunghyun;Lee, Jong Young
    • Radiation Oncology Journal
    • /
    • v.33 no.3
    • /
    • pp.242-249
    • /
    • 2015
  • Purpose: The purpose of this study is to compare the dosimetry of electron beam (EB) plans and three-dimensional helical tomotherapy (3DHT) plans for the patients with left-sided breast cancer, who underwent breast conserving surgery. Materials and Methods: We selected total of 15 patients based on the location of tumor, as following subsite: subareolar, upper outer, upper inner, lower lateral, and lower medial quadrants. The clinical target volume (CTV) was defined as the area of architectural distortion surrounded by surgical clip plus 1 cm margin. The conformity index (CI), homogeneity index (HI), quality of coverage (QC) and dose-volume parameters for the CTV, and organ at risk (OAR) were calculated. The following treatment techniques were assessed: single conformal EB plans; 3DHT plans with directional block of left anterior descending artery (LAD); and 3DHT plans with complete block of LAD. Results: 3DHT plans, regardless of type of LAD block, showed significantly better CI, HI, and QC for the CTVs, compared with the EB plans. However, 3DHT plans showed increase in the $V_{1Gy}$ at skin, left lung, and left breast. In terms of LAD, 3DHT plans with complete block of LAD showed extremely low dose, while dose increase in other OARs were observed, when compared with other plans. EB plans showed the worst conformity at upper outer quadrants of tumor bed site. Conclusion: 3DHT plans offer more favorable dose distributions to LAD, as well as improved target coverage in comparison with EB plans.

Comparison of Three Different Helmet Bolus Device for Total Scalp Irradiation (Total Scalp의 방사선 치료 시 Helmet Bolus 제작방법에 관한 연구)

  • Song, Yong-Min;Kim, Jong-Sik;Hong, Chae-Seon;Ju, Sang-Gyu;Park, Ju-Young;Park, Su-Yeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.31-37
    • /
    • 2012
  • Purpose: This study evaluated the usefulness of Helmet bolus device using Bolx-II, paraffin wax, solid thermoplastic material in total scalp irradiation. Materials and Methods: Using Rando phantom, we applied Bolx-II (Action Products, USA), paraffin wax (Densply, USA), solid thermoplastic material (Med-Tec, USA) on the whole scalp to make helmet bolus device. Computed tomography (GE, Ultra Light Speed16) images were acquired at 5 mm thickness. Then, we set up the optimum treatment plan and analyzed the variation in density of each bolus (Philips, Pinnacle). To evaluate the dose distribution, Dose-homogeneity index (DHI, $D_{90}/D_{10}$) and Conformity index (CI, $V_{95}/TV$) of Clinical Target Volume (CTV) using Dose-Volume Histogram (DVH) and $V_{20}$, $V_{30}$ of normal brain tissues. we assessed the efficiency of production process by measuring total time taken to produce. Thermoluminescent dosimeters (TLD) were used to verify the accuracy. Results: Density variation value of Bolx-II, paraffin wax, solid thermoplastic material turned out to be $0.952{\pm}0.13g/cm^3$, $0.842{\pm}0.17g/cm^3$, $0.908{\pm}0.24g/cm^3$, respectively. The DHI and CI of each helmet bolus device which used Bolx-II, paraffin wax, solid thermoplastic material were 0.89, 0.85, 0.77 and 0.86, 0.78, 0.74, respectively. The result of Bolx-II was the best. $V_{20}$ and $V_{30}$ of brain tissues were 11.50%, 10.80%, 10.07% and 7.62%, 7.40%, 7.31%, respectively. It took 30, 120, 90 minutes to produce. The measured TLD results were within ${\pm}7%$ of the planned values. Conclusion: The application of helmet bolus which used Bolx-II during total scalp irradiation not only improves homogeneity and conformity of Clinical Target Volume but also takes short time and the production method is simple. Thus, the helmet bolus which used Bolx-II is considered to be useful for the clinical trials.

  • PDF