• Title/Summary/Keyword: Conformal dome

Search Result 5, Processing Time 0.019 seconds

A Compact Top-View Conformal Optical System Based on a Single Rotating Cylindrical Lens with Wide Field of Regard

  • Yu, Linyao;Wei, Qun;Zheng, Jinggao;Ge, Mingda;Zhang, Tianyi
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.64-69
    • /
    • 2016
  • A new compact conformal dome optical system was established, and the aberration characteristics of the dome were investigated using Zernike aberration theory. The aberrations induced by the dome at different fields of regard (FORs) from 30° to 100° were effectively balanced by a rotating cylindrical lens. This kind of optical system can be widely used in top-view optical searching devices. A design method was introduced and the optimization results analyzed in detail. The results showed that the Zernike aberrations produced by the conformal dome were decreased dramatically. Also, a complete conformal optical system was designed, to further illustrate the aberration correction effect of the rotating cylindrical lens. Using a cylindrical lens not only provided a large FOR, but also simplified enormously the structure of the conformal optical system.

A New Full-Aperture Reflective Null Measuring Method for Conformal Dome

  • Yan, Xudong;Wang, Junhua;Xu, Min
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.174-179
    • /
    • 2016
  • In this paper, a novel full-aperture reflective null measuring method is proposed to detect the transmission wavefront of a conformal dome surface. An aspheric compensator is designed and placed behind the dome to reflect the aspheric testing wave back to the same path. To ensure the feasibility of this method, tolerance analysis is conducted, and guidance to assembly is given accordingly. The accuracy of this method is verified to be λ/30 (λ =3.39 μm) by Monte Carlo algorithm. In addition, the influence of different error factors, including the thickness error and decenter error of the dome, on the testing wavefront is analyzed. Simulation and experiment indicate that this method is practical and simple, and can measure the conformal domes precisely and comprehensively.

Analysis of the Radiation Pattern of Conformal Array Transducers (곡면 배열 트랜스듀서의 방사 특성 해석)

  • Kim, Hoe-Yong;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.7
    • /
    • pp.431-438
    • /
    • 2010
  • The radiation pattern of conformal transducers installed on a curved surface is likely to be complicated depending on the array pattern on the curved surface. In this research, the acoustic sources constituting a conformal transducer are arrayed in equi-angle, equi-interval, and geodesic dome forms, and the radiation pattern function of each of the array geometries has been derived, and therewith the radiation pattern has been analyzed for each array geometry. Based on the analysis result, we have determined the equi-interval array geometry that provides the widest beam width with the lowest side lobe level among the three array geometries. Results of the present work are expected to be utilized to the design of conformal transducer structures.

Optimal Design of Conformal Array Transducers (곡면 배열 트랜스듀서의 최적 설계)

  • Kim, Hoe-Yong;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.1
    • /
    • pp.51-61
    • /
    • 2012
  • In this research, we have analyzed the trend of radiation pattern variation in relation to the change of design variables such as source interval and source number for conformal array transducers arranged in equi-angle, equi-interval, and geodesic dome forms. Through statistical multiple regression analysis of the results, we derived functional forms of the side lobe level and the beamwidth in terms of the design variables. Futhermore, the structure of the array transducer was optimized to achieve the smallest side lobe level while satisfying the requirements on beam width by the GA (genetic algorithm) method. Based on the optimized results, we have determined the equi-interval form as the optimal array geometry among the three conformal array geometries.

Comparison of Dose Distributions Calculated by Anisotropic Analytical Algorithm and Pencil Beam Convolution Algorithm at Tumors Located in Liver Dome Site (간원개에 위치한 종양에 대한 Anisotropic Analyticalal Algorithm과 Pencil Beam Convolution 알고리즘에 따른 전달선량 비교)

  • Park, Byung-Do;Jung, Sang-Hoon;Park, Sung-Ho;Kwak, Jeong-Won;Kim, Jong-Hoon;Yoon, Sang-Min;Ahn, Seung-Do
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.106-113
    • /
    • 2012
  • The purpose of this study is to evaluate the variation of radiation dose distribution for liver tumor located in liver dome and for the interest organs(normal liver, kidney, stomach) with the pencil beam convolution (PBC) algorithm versus anisotropic Analyticalal algorithm (AAA) of the Varian Eclipse treatment planning system, The target volumes from 20 liver cancer patients were used to create treatment plans. Treatment plans for 10 patients were performed in Stereotactic Body Radiation Therapy (SBRT) plan and others were performed in 3 Dimensional Conformal Radiation Therapy (3DCRT) plan. dose calculation was recalculated by AAA algorithm after dose calculation was performed by PBC algorithm for 20 patients. Plans were optimized to 100% of the PTV by the Prescription Isodose in Dose Calculation with the PBC algorithm. Plans were recalculated with the AAA, retaining identical beam arrangements, monitor units, field weighting and collimator condition. In this study, Total PTV was to be statistically significant (SRS: p=0.018, 3DCRT: p=0.006) between PBC and AAA algorithm. and in the case of PTV, ITV in liver dome, plans for 3DCRT were to be statistically significant respectively (p=0.013, p=0.024). normal liver and kidney were to be statistically significant (p=0.009, p=0.037). For the predictive index of dose variation, CVF ratio was to be statistically significant for PTV in the liver dome versus PTV (SRS r=0.684, 3DCRT r=0.732, p<0.01) and CVF ratio for Tumor size was to be statistically significant (SRS r=-0.193, p=0.017, 3DCRT r=0.237, p=0.023).