• 제목/요약/키워드: Conformal

검색결과 774건 처리시간 0.025초

The response of thrombosis in the portal vein or hepatic vein in hepatocellular carcinoma to radiation therapy

  • Bae, Bong Kyung;Kim, Jae-Chul
    • Radiation Oncology Journal
    • /
    • 제34권3호
    • /
    • pp.168-176
    • /
    • 2016
  • Purpose: The purpose of current study is to evaluate the response of the patients with portal vein thrombosis (PVT) or hepatic vein thrombosis (HVT) in hepatocellular carcinoma (HCC) treated with three-dimensional conformal radiation therapy (3D-CRT). In addition, survival of patients and potential prognostic factors of the survival was evaluated. Materials and Methods: Forty-seven patients with PVT or HVT in HCC, referred to our department for radiotherapy, were retrospectively reviewed. For 3D-CRT plans, a gross tumor volume (GTV) was defined as a hypodense filling defect area in the portal vein (PV) or hepatic vein (HV). Survival of patients, and response to radiation therapy (RT) were analyzed. Potential prognostic factors for survival and response to RT were evaluated. Results: The median survival time of 47 patients was 8 months, with 1-year survival rate of 15% and response rate of 40%. Changes in Child-Pugh score, response to RT, Eastern cooperative oncology group performance status (ECOG PS), hepatitis C antibody (HCVAb) positivity, and additional post RT treatment were statistically significant prognostic factors for survival in univariate analysis (p = 0.000, p = 0.018, p = 0.000, p = 0.013, and p = 0.047, respectively). Of these factors, changes in Child-Pugh score, and response to RT were significant for patients' prognosis in multivariate analysis (p = 0.001 and p = 0.035, respectively). Conclusion: RT could constitute a reasonable treatment option for patients with PVT or HVT in HCC with acceptable toxicity. Changes in Child-Pugh score, and response to RT were statistically significant factors of survival of patients.

Gemcitabine-based Concurrent Chemoradiotherapy Versus Chemotherapy Alone in Patients with Locally Advanced Pancreatic Cancer

  • Wang, Bu-Hai;Cao, Wen-Miao;Yu, Jie;Wang, Xiao-Lei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권5호
    • /
    • pp.2129-2132
    • /
    • 2012
  • Objective: To explore improved treatment by retrospectively comparing survival time of gemcitabine-based concurrent chemoradiotherapy (GemRT) versus chemotherapy (Gem) alone in patients with locally advanced pancreatic cancer (LAPC). Methods: From January 2005 to June 2010, 56 patients with LAPC from Subei People's Hospital were treated either with Gem (n=21) or GemRT (n=35). Gem consisted of 4-6 cycles gemcitabine alone (1000 mg/m2 on Days 1, 8, 15, 28-day a cycle). GemRT consisted of 50.4Gy/28F radiotherapy with concurrent 2 cycles of gemcitabine (1000 $mg/m^2$ on days of radiation 1, 8, 15, 21-day a cycle). Radiation was delivered to the gross tumor volume plus 1-1.5 cm by use of a three-dimensional conformal technique. The follow-up time was calculated from the time of diagnosis to the date of death or last contact. Kaplan-Meier methodology wes used to evaluate survival. Results: Patient characteristics were not significantly different between treatment groups. The disease control rate and the objective response rate of GemRT versus Gem was 97.1% vs 71.4%, 74.3% vs 38.1%. The overall survival (OS) was significantly better for GemRT compared to Gem (median 13 months versus 8 months; 51.4% versus 14.3% at 1 year, respectively). Conclusion: Radiation therapy at 50.4Gy with 2 concurrent cycles of gemcitabine results in favorable rates of OS. Concurrent chemoradiotherapy should be the first choice for patients with LAPC.

Water vapor permeation properties of $Al_2O_3/TiO_2$ passivation layer on a poly (ether sulfon) substrate

  • 권태석;문연건;김웅선;문대용;김경택;한동석;신새영;박종완
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.160-160
    • /
    • 2010
  • Organic electronic devices require a passivation layer to ensure sufficient lifetime. Specifically, flexible organic electronic devices need a barrier layer that transmits less than $10^{-6}\;g/m^2/day$ of water and $10^{-5}\;g/m^2/day$ of oxygen. To increase the lifetime of organic electronic device, therefore, it is indispensable to protect the organic materials from water and oxygen. Severe groups have reported on multi-layerd barriers consisting inorganic thin films deposited by plasma enhenced chemical deposition (PECVD) or sputtering. However, it is difficult to control the formation of granular-type morphology and microscopic pinholes in PECVD and sputtering. On the contrary, atomic layer deoposition (ALD) is free of pinhole, highly uniform, conformal films and show good step coverage. In this study, the passivation layer was deposited using single-process PEALD. The passivation layer, in our case, was a bilayer system consisting of $Al_2O_3$ films and a $TiO_2$ buffer layer on a poly (ether sulfon) (PES) substrate. Because the deposition temperature and plasma power have a significant effect on the properties of the passivation layer, the characteristics of the $Al_2O_3$ films were investigated in terms of density under different deposition temperatures and plasma powers. The effect of the $TiO_2$ buffer layer also was also addressed. In addition, the water vapor transmission rate (WVTR) and organic light-emitting diode (OLEDs) lifetime were measured after forming a bilayer composed of $Al_2O_3/TiO_2$ on a PES substrate.

  • PDF

국제물품매매에서 물품의 계약적합성에 관한 연구 (A Study on the Conformity of the Goods under International Sale)

  • 오현석
    • 무역상무연구
    • /
    • 제66권
    • /
    • pp.25-46
    • /
    • 2015
  • The purpose of this paper is to provide a legal implication about conformity of goods in the international commercial transactions. There are so many legal relationship after the formation of contract. The most of important thing among the obligations of seller is to provide conformal goods which are of quantity, quality and description required by the contract and which are contained or packaged in the manner required by the contract. If seller violate above duties, seller take the warranty liability. However, CISG describe the conformity of the goods instead of the warranty as follows. First, CISG Art.35(1) states standards for determining whether goods delivered by the seller conform to the contract and Art.35(2) describes standards relating to the goods' quality, function and packaging that, while not mandatory, are presumed to be a part of sales contracts. Article 35(2) is comprised of four subparts. Two of the subparts (article 35(2) (a) and article 35(2)(d)) apply to all contracts unless the parties have agreed otherwise. Second, CISG Art.36 and 38 deals with the time at which a lack of conformity in the goods must have arisen in order for the seller to be liable for it. If seller lack of conformity becomes apparent only after that time, seller is liable for a lack of conformity existing when risk passed to the buyer. Third, CISG Art.49 describe that a buyer who claims that delivered goods do not conform to the contract has an obligation to give the seller notice of the lack of conformity. The most of important things about CISG articles and precedents is that buyer is aware of the lack of conformity and notice it to seller. Failure to satisfy the notice requirements of article 39 eliminates a buyer's defence, based on a lack of conformity in delivered goods, to a seller's claim for payment of the price. Consequently, parties of contract had better agree to the notifying times about lack of conformity. Also, If seller fined the non-conformity, seller has to notify this circumstance to the buyer within short period or agreed time.

  • PDF

Role of salvage radiotherapy for regional lymph node recurrence after radical surgery in advanced gastric cancer

  • Kim, Byoung Hyuck;Eom, Keun-Yong;Kim, Jae-Sung;Kim, Hyung-Ho;Park, Do Joong
    • Radiation Oncology Journal
    • /
    • 제31권3호
    • /
    • pp.147-154
    • /
    • 2013
  • Purpose: To evaluate the role of salvage radiotherapy (RT) for the treatment of regional lymph node recurrence (RLNR) after radical surgery in advanced gastric cancer. Materials and Methods: We retrospectively analyzed medical records of 26 patients who underwent salvage treatment after diagnosis of RLNR between 2006 and 2011. Patients with peritoneal seeding or distant metastasis were excluded. Eighteen patients received RT with or without chemotherapy and the other 8 did chemotherapy only without RT. A three-dimensional conformal RT was performed with median dose of 56 Gy (range, 44 to 60 Gy). Sixteen patients had fluoropyrimidine-based chemotherapy, 5 did taxane-based chemotherapy, and irinotecan was applied in 4. Results: With a median follow-up of 20 months (range, 5 to 57 months), median overall survival (OS) and progression-free survival (PFS) after diagnosis of RLNR were 29 months and 12 months in the entire patients, respectively. Radiotherapy (p = 0.007) and disease-free interval (p = 0.033) were statistically significant factors for OS in multivariate analysis. Median OS was 36 months in patients who received RT and 16 months in those who did not. Furthermore, delivery of RT (p < 0.001), complete remission after salvage treatment (p = 0.040) and performance status (p = 0.023) were associated with a significantly better PFS. Gastrointestinal toxicities from RT were mild in most patients. Conclusion: Salvage RT combined with systemic chemotherapy may be an effective treatment managing RLNR from advanced gastric cancer.

Radiotherapy for gastric mucosa-associated lymphoid tissue lymphoma: dosimetric comparison and risk assessment of solid secondary cancer

  • Bae, Sun Hyun;Kim, Dong Wook;Kim, Mi-Sook;Shin, Myung-Hee;Park, Hee Chul;Lim, Do Hoon
    • Radiation Oncology Journal
    • /
    • 제35권1호
    • /
    • pp.78-89
    • /
    • 2017
  • Purpose: To determine the optimal radiotherapy technique for gastric mucosa-associated lymphoid tissue lymphoma (MALToma), we compared the dosimetric parameters and the risk of solid secondary cancer from scattered doses among anterior-posterior/ posterior-anterior parallel-opposed fields (AP/PA), anterior, posterior, right, and left lateral fields (4_field), 3-dimensional conformal radiotherapy (3D-CRT) using noncoplanar beams, and intensity-modulated radiotherapy composed of 7 coplanar beams (IMRT_co) and 7 coplanar and noncoplanar beams (IMRT_non). Materials and Methods: We retrospectively generated 5 planning techniques for 5 patients with gastric MALToma. Homogeneity index (HI), conformity index (CI), and mean doses of the kidney and liver were calculated from the dose-volume histograms. Applied the Biological Effects of Ionizing Radiation VII report to scattered doses, the lifetime attributable risk (LAR) was calculated to estimate the risk of solid secondary cancer. Results: The best value of CI was obtained with IMRT, although the HI varied among patients. The mean kidney dose was the highest with AP/PA, followed by 4_field, 3D-CRT, IMRT_co, and IMRT_non. On the other hand, the mean liver dose was the highest with 4_field and the lowest with AP/PA. Compared with 4_field, the LAR for 3D-CRT decreased except the lungs, and the LAR for IMRT_co and IMRT_non increased except the lungs. However, the absolute differences were much lower than <1%. Conclusion: Tailored RT techniques seem to be beneficial because it could achieve adjacent organ sparing with very small and clinically irrelevant increase of secondary solid cancer risk compared to the conventional techniques.

Radiotherapy for locally recurrent rectal cancer treated with surgery alone as the initial treatment

  • Tanaka, Hidekazu;Yamaguchi, Takahiro;Hachiya, Kae;Okada, Sunaho;Kitahara, Masashi;Matsuyama, Katsuya;Matsuo, Masayuki
    • Radiation Oncology Journal
    • /
    • 제35권1호
    • /
    • pp.71-77
    • /
    • 2017
  • Purpose: Although the technical developments of radiotherapy have been remarkable, there are currently few reports on the treatment results of radiotherapy for local recurrence of rectal cancer treated with surgery alone as initial treatment in this three-dimensional conformal radiotherapy era. Thus, we retrospectively evaluated the treatment results of radiotherapy for local recurrence of rectal cancer treated with surgery alone as the initial treatment. Materials and Methods: Thirty-two patients who underwent radiotherapy were enrolled in this study. The dose per fraction was 2.0-3.5 Gy. Because the treatment schedule was variable, the biological effective dose (BED) was calculated. Results: Local control (LC) and overall survival (OS) rates from the completion of radiotherapy were calculated. The 1-, 2-, 3-, 4-, and 5-year LC rates were 51.5%, 24.5%, 19.6%, 19.6%, and 13.1%, respectively. LC rates were significantly higher for the high BED group (${\geq}75Gy_{10}$) than for the lower BED group (<$75Gy_{10}$). All patients who reported pain achieved pain relief. The duration of pain relief was significantly higher for the high BED group than for the lower BED group. The 1-, 2-, 3-, 4-, and 5-year OS rates were 82.6%, 56.5%, 45.2%, 38.7%, and 23.2%, respectively. There was a trend toward higher OS rates in with higher BED group compared to lower BED group. Conclusion: For patients with unresectable locally recurrent rectal cancer treated with surgery alone, radiotherapy is effective treatment. The prescribed BED should be more than $75Gy_{10}$, if the dose to the organ at risk is within acceptable levels.

The role of salvage radiotherapy in recurrent thymoma

  • Yang, Andrew Jihoon;Choi, Seo Hee;Byun, Hwa Kyung;Kim, Hyun Ju;Lee, Chang Geol;Cho, Jaeho
    • Radiation Oncology Journal
    • /
    • 제37권3호
    • /
    • pp.193-200
    • /
    • 2019
  • Purpose: To explore the role of salvage radiotherapy (RT) for recurrent thymoma as an alternative to surgery. Materials and Methods: Between 2007 and 2015, 47 patients who received salvage RT for recurrent thymoma at Yonsei Cancer Center were included in this study. Recurrent sites included initial tumor bed (n = 4), pleura (n = 19), lung parenchyma (n = 10), distant (n = 9), and multiple regions (n = 5). Three-dimensional conformal and intensity-modulated RT were used in 29 and 18 patients, respectively. Median prescribed dose to gross tumor was 52 Gy (range, 30 to 70 Gy), with equivalent doses in 2-Gy fractions (EQD2). We investigated overall survival (OS), progression-free survival (PFS), and patterns of failure. Local failure after salvage RT was defined as recurrence at the target volume receiving >50% of the prescription dose. Results: Median follow-up time was 83 months (range, 8 to 299 months). Five-year OS and PFS were 70% and 22%, respectively. The overall response rate was 97.9%; complete response, 34%; partial response, 44.7%; and stable disease, 19.1%. In multivariate analysis, histologic type and salvage RT dose (≥52 Gy, EQD2) were significantly associated with OS. The high dose group (≥52 Gy, EQD2) had significantly better outcomes than the low dose group (5-year OS: 80% vs. 59%, p = 0.046; 5-year PFS: 30% vs. 14%, p=0.002). Treatment failure occurred in 34 patients; out-of-field failure was dominant (intra-thoracic recurrence 35.3%; extrathoracic recurrence 11.8%), while local failure rate was 5.8%. Conclusion: Salvage RT for recurrent thymoma using high doses and advanced precision techniques produced favorable outcomes, providing evidence that recurrent thymoma is radiosensitive.

Development of the DVH management software for the biologically-guided evaluation of radiotherapy plan

  • Kim, Bo-Kyong;Park, Hee-Chul;Oh, Dong-Ryul;Shin, Eun-Hyuk;Ahn, Yong-Chan;Kim, Jin-Sung;Han, Young-Yih
    • Radiation Oncology Journal
    • /
    • 제30권1호
    • /
    • pp.43-48
    • /
    • 2012
  • Purpose: To develop the dose volume histogram (DVH) management software which guides the evaluation of radiotherapy (RT) plan of a new case according to the biological consequences of the DVHs from the previously treated patients. Materials and Methods: We determined the radiation pneumonitis (RP) as an biological response parameter in order to develop DVH management software. We retrospectively reviewed the medical records of lung cancer patients treated with curative 3-dimensional conformal radiation therapy (3D-CRT). The biological event was defined as RP of the Radiation Therapy Oncology Group (RTOG) grade III or more. Results: The DVH management software consisted of three parts (pre-existing DVH database, graphical tool, and $Pinnacle^3$ script). The pre-existing DVH data were retrieved from 128 patients. RP events were tagged to the specific DVH data through retrospective review of patients' medical records. The graphical tool was developed to present the complication histogram derived from the preexisting database (DVH and RP) and was implemented into the radiation treatment planning (RTP) system, $Pinnacle^3$ v8.0 (Phillips Healthcare). The software was designed for the pre-existing database to be updated easily by tagging the specific DVH data with the new incidence of RP events at the time of patients' follow-up. Conclusion: We developed the DVH management software as an effective tool to incorporate the phenomenological consequences derived from the pre-existing database in the evaluation of a new RT plan. It can be used not only for lung cancer patients but also for the other disease site with different toxicity parameters.

Highly Flexible Touch Screen Panel Fabricated with Silver Nanowire Crossing Electrodes and Transparent Bridges

  • Jeon, Youngeun;Jin, Han Byul;Jung, Sungchul;Go, Heungseok;Lee, Innam;Lee, Choonhyop;Joo, Young Kuil;Park, Kibog
    • Journal of the Optical Society of Korea
    • /
    • 제19권5호
    • /
    • pp.508-513
    • /
    • 2015
  • A capacitive-type touch screen panel (TSP) composed of silver nanowire (AgNW) crossing electrodes and transparent bridge structures was fabricated on a polycarbonate film. The transparent bridge structure was formed with a stack of Al-doped ZnO (AZO) electrodes and SU-8 insulator. The stable and robust continuity of the bridge electrode over the bridge insulator was achieved by making the side-wall slope of the bridge insulator low and depositing the conformal AZO film with atomic layer deposition. With an extended exposure time of photolithography, the lower part of the SU-8 layer around the region uncovered by the photomask can be exposed enough to the UV light scattered from the substrate. This leads to the low side-wall slope of the bridge insulator. The fabricated TSP sample showed a large capacitance change of 22.71% between with and without touching. Our work supplies the technological clue for ensuring long-term reliability to the highly flexible and transparent TSP made by using conventional fabrication processes.