• Title/Summary/Keyword: Confinement stress

Search Result 225, Processing Time 0.027 seconds

Effect of axial loading conditions and confinement type on concrete-steel composite behavior

  • Nematzadeh, Mahdi;Fazli, Saeed
    • Computers and Concrete
    • /
    • v.25 no.2
    • /
    • pp.95-109
    • /
    • 2020
  • This paper aims to analytically study the effect of loading conditions and confinement type on the mechanical properties of the concrete-steel composite columns under axial compressive loading. The axial loading is applied to the composite columns in the two ways; only on the concrete core, and on the concrete core and steel tube simultaneously, which are called steel tube-confined concrete (STCC) and concrete-filled steel tube (CFST) columns, respectively. In addition, the confinement is investigated in the three types of passive, short-term active and long-term active confinement. Nonlinear finite element 3D models for analyzing these columns are developed using the ABAQUS program, and then these models are verified with respect to the recent experimental results reported by the authors on the STCC and CFST columns experiencing active and passive confinements. Axial and lateral stress-strain curves as well as the failure mode for qualitative verification, and compressive strength for quantitative verification are considered. It is found that there is a good consistency between the finite element analysis results and the experimental ones. In addition, a parametric study is performed to evaluate the effect of axial loading type, prestressing ratio, concrete compressive strength and steel tube diameter-to-wall thickness ratio on the compressive behavior of the composite columns. Finally, the compressive strength results of CFST specimens obtained via the finite element analysis are compared with the values specified by the international codes and standards including EC4, CSA, ACI-318, and AISC, with the results showing that ACI-318 and AISC underestimate the compressive strength of the composite columns, while EC4 and CSA codes present overestimated values.

Constitutive Model of Laterally Confined High Strength Concrete (횡구속된 고강도 콘크리트의 구성모델)

  • Yun, Sung-Hwan;Kang, Yoon-Sig;Park, Tae-Hyo
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.4
    • /
    • pp.481-488
    • /
    • 2010
  • Since existing constitutive models developed for confined normal strength concrete overestimate ductility when they are applied to confined high strength concrete, these models cannot be directly applied to confined high strength concrete. In an effort to solve this problem, an accurate stress-strain relationship of the hihg strength concrete needs to be formulated by examining the confinement effects due to increase of the concrete strength. In this study, a constitutive model is developed to express the stress-strain relationship of confined high strength concrete by carrying out regression analysis of the main parameters affection strength and ductile behavior of reinforced high strength concrete columns. Twenty-five test specimens were chosen from the reported experimental studies in the literature. The experimental results of stress-strain relationships of show a good agreement with results of the stress-strain relationships of suggested high strength concrete, covering a strength range between 60 and 124 MPa.

Effects of Confinement and Transport Stress on Physiological Condition in Olive Flounder, Paralichthys olivaceus (가두기와 활어수송 스트레스가 넙치, Paralichthys olivaceus의 생리조건에 미치는 영향)

  • ;;;William H. Neill
    • Journal of Aquaculture
    • /
    • v.16 no.3
    • /
    • pp.135-141
    • /
    • 2003
  • Physiological responses (cortisol, glucose, lactic acid, osmolality and hematology) of olive flounder (Paralichthys olivaceus) to stressors associated with confinement and subsequent transport were investigated. Specimens were subjected to confinement stress for 3 h, prior to transport for 15 h. Two different size cohorts of the fish, large (839.6$\pm$162.7 g) and small (98.2$\pm$14.8 g), were used. Experimental cohorts of the fish were divided into 3 groups for blood sampling: group A, sampled at the beginning of confinement and 3 h before transport (BT, -3 h), after confinement and at the beginning of transport (BT, 0 h), 3 h after transport had begun (AT, 3 h), and after 15 h transport (AT, 15 h); group B, sampled at BT, 0 h, at AT, 3 h, and at AT, 15 h; and, group C, sampled at AT, 3 h, and at AT, 15 h. In the cohort of large fish, plasma cortisol levels of the A group were increased over time, from 4.2 ng/ml (BT,-3 h), to 92.0 ng/ml (BT, 0 h), 118.5 ng/ml (AT, 3 h) and 105.5 ng/ml (AT, 15 h). A similar pattern was evident in the B group, in which cortisol increased from 47.5 ng/ml (BT, 0 h) to 53.5 ng/ml (AT, 15 h); and, for the C group, in which cortisol increased from 43.5 ng/ml (AT, 3 h) to 71.5 ng/ml (AT, 15 h). Glucose levels of the A group also were significantly increased, from 39.5 mg/dl (BT,-3 h), to 121.0 mg/dl (BT, 0 h),298.0 mg/dl (AT, 3 h) and 260.5 mg/dl (AT, 15 h). Lactic acid levels increased markedly during transport, from less than 1 mmol/L (BT, 0 h) to 12.0 mmol/L (AT, 15 h). Plasma osmolality increased from 405.5 mOsm/kg (BT, -3 h, for group A) to values near 500 mOsM/kg subsequent to confinement and transport. In the small-size cohort, plasma cortisol, glucose, lactic acid and osmolality levels showed similar but less pronounced trends than those observed for the large-size cohort. This research provides baseline data on cortisol, glucose, lactic acid, osmolality and hematological responses to confinement and transport, which should be useful to aquaculturists working with olive flounder and to scientists studying other flatfish species.

Axial Behavior of Concrete Cylinders Confined with FRP Wires (FRP 와이어 보강 콘크리트 공시체의 압축거동)

  • Cho, Baiksoon;Lee, Jong-Han;Choi, Eunsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.1765-1775
    • /
    • 2013
  • The application of FRP wire as a mean of improving strength and ductility capacity of concrete cylinders under axial compressive load through confinement is investigated experimentally in this study. An experimental investigation involves axial compressive test of three confining amounts of FRP wire and three concrete compressive strengths. The effectiveness of FRP wire confinement on the concrete microstructure were examined by evaluating the internal concrete damage using axial, circumferential, and volumetric strains. The axial stress-strain relations of FRP wire confined concrete showed bilinear behavior with transition region. It showed strain-hardening behavior in the post-cracking region. The load carrying capacity was linearly increased with increasing of the amount of FRP wire. The ultimate strength of the 35 MPa specimen confined with 3 layer of FRP wire was increased by 286% compared to control one. When the concrete were effectively confined with FRP wire, horizontal cracks were formed by shearing. It was developed from sudden expansion of the concrete due to confinement ruptures at one side while the FRP wire was still working in hindering expansion of concrete at the other side of the crack. The FRP wire failure strains obtained from FRP wire confined concrete tests were 55~90%, average 69.5%, of the FRP wire ultimate uniaxial tensile strain. It was as high as any other FRP confined method. The magnitude of FRP wire failure strain was related to the FRP wire effectiveness.

Stress-Strain Relations of Plain and Confined Concrete (횡보강 효과를 고려한 콘크리트의 응력-변형도 관계)

  • 김진근;이태규;서용표
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1990.04a
    • /
    • pp.116-121
    • /
    • 1990
  • Baxed on the results tested by various researchers, a complete stress-strain relation of plain and confined concrete is proposed. The peak strength and the corresponding strain are calculated by using the Mohr-Coulomb theory and elastic tri-axial constitutive relation. A parametric study was conducted to assess the influence of the plain concrete strength, the degree of confinement, the shape of the section, and the tie configuration for the square section. According to this model, the behavior of concrete section is predicted, and compared with experimental data and other proposed models on circular and square sections. A good agreement between theoretical and experimental results is observed.

  • PDF

The Experimental Study on Stress-Strain Relation of Confined Concrete with Different Transverse Reinforcements (횡철근 상세에 따른 횡구속 콘크리트의 응력-변형률에 관한 연구)

  • Jeong Hyeok Chang;Sun Chang Ho;Kim Ick Hyun;Lee Jong Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.117-120
    • /
    • 2005
  • In order to achieve target ductility the stress-strain relation of confined concrete is indispensible. In this study the specimens with different transverse reinforcement ratios were tested. The test results were compared with empirical equations and the characteristics of confinement effect were investigated.

  • PDF

Characteristics of stress-strain relations of confined rectangular sectional concrete elements with various lateral reinforcement ratios and cross-ties (횡철근비와 cross-tie가 다른 횡구속 사각단면 콘크리트의 응력-변형률 특성)

  • Jeong, Hyeok-Chang;Park, Tae-Soo;Sun, Chang-Ho;Kim, Ick-Hyun;Lee, Jong-Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.89-92
    • /
    • 2006
  • In order to achieve target ductility the stress-strain relation of confined concrete is indispensible. In this study the specimens with different transverse reinforcement ratios were tested. The test results were compared with empirical equations and the characteristics of confinement effect were investigated.

  • PDF

An Experimental Study on Uniaxial Compressive Behavior of RC Circular Columns Laterally Confined with Prestressing Aramid Fiber Strap (아라미드 스트랩으로 프리스트레싱 횡구속된 RC 원형기둥의 일축압축거동에 관한 실험적 연구)

  • Han, Sang-Hoon;Hong, Ki-Nam;Lee, Jae-Bum
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.2
    • /
    • pp.159-168
    • /
    • 2009
  • In this study, strength, stiffness and confinement effect with stress-strain and stress-volumetric strain curves for improved uniaxial compressive behavior of RC circular columns laterally confined with prestressing aramid fiber strap were experimentally investigated. The test variables were the specimens with or without axial reinforcing bar and the number and spacing of strap, prestressing level, the types of reinforcing fiber (CFS, GFS). As a result, the failure type of the columns was very stable and strength increase rate was about 73% comparison with the general RC columns. Moreover, the strain increase rate is very small and the axial displacement confinement effect was very effective compared with existry methods (CFS, GFS), the initial and final lateral confinement effect was excellent.

Self-consolidating concrete filled steel tube columns - Design equations for confinement and axial strength

  • Lachemi, M.;Hossain, K.M.A.;Lambros, V.B.
    • Structural Engineering and Mechanics
    • /
    • v.22 no.5
    • /
    • pp.541-562
    • /
    • 2006
  • This paper compares the performance of axially loaded concrete filled steel tube (CFST) columns cast using a conventionally vibrated normal concrete (NC) and a novel self-consolidating concrete (SCC) made with a new viscosity modifying admixture (VMA). A total of sixteen columns with a standard compressive strength of about 50 MPa for both SCC and NC were tested by applying concentric axial load through the concrete core. Columns were fabricated without and with longitudinal and hoop reinforcement (Series I and Series II, respectively) in addition to the tube confinement. The slenderness of the columns expressed as height to diameter ratio (H/D) ranged between 4.8 and 9.5 for Series CI and between 3.1 and 6.5 for Series CII. The strength and ductility of SCC columns were found comparable to those of their NC counterparts as the maximum strength enhancement in NC columns ranged between 1.1% and 7.5% only. No significant difference in strain development was found due to the presence of SCC or NC or due to the presence of longitudinal and hoop reinforcement. Biaxial stress development in the steel tube as per von Mises yield criterion showed similar characteristics for both SCC and NC columns. The confined strength ($f^{\prime}_{cc}$) of SCC was found to be lower than that of NC and $f^{\prime}_{cc}$ also decreased with the increase of slenderness of the columns. Analytical models for the prediction of confined concrete strength and axial strength of CFST columns were developed and their performance was validated through test results. The proposed models were found to predict the axial strength of CFST columns better than existing models and Code based design procedures.

Uniaxial Compression Behavior of Circular RC Columns Confined by Carbon Fiber Sheet Wraps (탄소섬유시트로 구속된 원형 RC기둥의 일축압축 거동)

  • Han, Sang Hoon;Hong, Ki Nam
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.2
    • /
    • pp.125-133
    • /
    • 2007
  • External confinement by CFS (Carbon Fiber Sheet) is a very effective retrofit method for the reinforced concrete columns subject to either static or seismic loads. For the reliable and cost-effective design of CFS, an accurate stress-strain curve is required for CFS-confined concrete. In this paper, uniaxial compression test on short RC column with circular section was performed. To evaluate the effect of confinement on the stress-strain relationship of CFS-confined concrete, CFS area ratio, spiral area ratio, and concrete compressive strength are considered as the test variables. Experiment results indicate that CFS jacketing significantly enhances strength and ductility of concrete. In addition, the CFS-jacketed specimens with the spiral steel show the lower load increasement ratio than those without the spiral steel.