• Title/Summary/Keyword: Configuration factor

Search Result 532, Processing Time 0.026 seconds

Comprehensive Analysis of Major Factors Associated with the Performance of Reverse Osmosis Desalination Plant for Energy-saving (에너지 소모를 고려한 역삼투 해수담수화 플랜트 주요 성능인자 영향 분석)

  • Kim, Jihye;Lee, Kyung-Hyuk;Lim, Jae-Lim
    • Membrane Journal
    • /
    • v.29 no.6
    • /
    • pp.314-322
    • /
    • 2019
  • A worsened drought in Chungnam province of Korea due to climate change and increasing water demand at Daesan industrial complex have motivated the 100,000 ㎥/d seawater desalination project. In this study, therefore, the comprehensive analysis of parameters affecting the reverse osmosis (RO) performance was conducted. Under the various conditions of feedwater salinity and temperature in Daesan, energy consumption was calculated as 2.39 ± 0.13 kWh/㎥. The decrease in membrane flux and recovery rate positively impacted annual operation cost. The average total dissolved solids (TDS) of the permeate and energy consumption with highly permeable membrane according to the membrane manufacturer were 3.84 mg/L and 2.22 ± 0.13 kWh/㎥, respectively. In addition, energy saving up to 0.29 kWh/㎥ or cost reduction of membrane module up to 15.6% is expected by changing the RO configuration from full two pass to partial or split partial two pass.

Performance Analysis of Group Scheduling for Core Nodes in Optical Burst Switching Networks (광 버스트 스위칭 네트워크의 코어 노드를 위한 그룹 스케줄링 성능 분석)

  • 신종덕;이재명;김형석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.8B
    • /
    • pp.721-729
    • /
    • 2004
  • In this paper, we applied a group scheduling algorithm to core nodes in an optical burst switching (OBS) network and measured its performance by simulation. For the case of core nodes with multi-channel input/output ports, performance of the group scheduling has been compared to that of the immediate scheduling. Since the group scheduling has a characteristic of scheduling a group of bursts simultaneously in a time window using information collected from corresponding burst header packets arrived earlier to a core node, simulation results show that the group scheduling outperforms the immediate scheduling in terms of both burst loss probability and channel utilization and the difference gets larger as the load increases. Another node configuration in which wavelength converters are equipped at the output ports has also been considered. In this case, even though both performance metrics of the group scheduling are almost the same as those of the immediate scheduling in the offered load range between 0.1 and 0.9, the group scheduling has lower wavelength conversion rate than the immediate scheduling by at least a factor of seven. This fact leads us to the conclusion that the group scheduling makes it possible to implement more economical OBS core nodes.

XA and Non-XA Interface Methodology of an X/Open DTP-based Trading System in Finance Industry (X/Open DTP 기반 증권사 트레이딩 시스템에서의 XA/Non-XA 인터페이스 방법)

  • Kim, Yong-Tae;Byun, Chang-Woo;Park, Seog
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.9 no.5
    • /
    • pp.498-508
    • /
    • 2003
  • In the field of finance, Trading System of Securities is a very vulnerable application when it faces any small problems just for one minute. Since Trading System changes its environment from mainframes to client/server, its safety becomes the most important factor. Even though most If systems are configured by general guidelines currently, Trading System is an exception that it is configured by specific and rather ad hoc guidelines in order to ensure its safe management. In this thesis, I will prove the validity of specific and ad hoc configuration in the environment of Trading Systems where I use both XA interface system and Non-XA interface to configure its system based on 3-Tier Client/server computing environment through middleware, TP-Monitor, in the X/Open DTP Model. In order to validate the Trading System, I will compare and analyze the error of data of an order and ability to restore using both XA and Non-XA interfaces while testing take-over scenario on the assumption of the system's failure.

Control of $Ca^{2+}$- Influx by $Ca^{2+}$/Calmodulin Dependent Protein Kinase II in the Activation of Mouse Eggs

  • Yoon, Sook-Young;Kang, Da-Won;Bae, In-Ha
    • Development and Reproduction
    • /
    • v.15 no.1
    • /
    • pp.31-39
    • /
    • 2011
  • Change in intracellular $Ca^{2+}$-concentration ($[Ca^{2+}]_i$) is an essential event for egg activation and further development. $Ca^{2+}$ ion is originated from intracellular $Ca^{2+}$-store via inositol 1,4,5-triphosphate receptor and/or $Ca^{2+}$ influx via $Ca^{2+}$ channel. This study was performed to investigate whether changes in $Ca^{2+}$/calmodulin dependent protein kinase II (CaM KII) activity affect $Ca^{2+}$ influx during artificial egg activation with ethanol using $Ca^{2+}$ monitoring system and whole-cell patch clamp technique. Under $Ca^{2+}$ ion-omitted condition, $Ca^{2+}$-oscillation was stopped within 30 min post microinjection of porcine sperm factor, and ethanol-induced $Ca^{2+}$ increase was reduced. To investigate the role of CaM KII known as an integrator of $Ca^{2+}$- oscillation during mammalian egg fertilization, CaM KII activity was tested with a specific inhibitor KN-93. In the eggs treated with KN-93, ethanol failed to induce egg activation. In addition, KN-93 inhibited inward $Ca^{2+}$ current ($I_{Ca}$) in a time-dependent manner in whole-cell configuration. Immunostaining data showed that the voltage-dependent $Ca^{2+}$ channels were distributed along the plasma membrane of mouse egg and 2-cell embryo. From these results, we suggest that $Ca^{2+}$ influx during fertilization might be controlled by CaM KII activity.

Chromosome and Spindle Configuration of Mouse Oocytes after Vitrification at the Mature Stage (마우스 성숙난자의 유리화 동결법에 따른 동결 융해 후의 염색체와 방추사의 분석)

  • ;;;;Gary B. Anderson
    • Korean Journal of Animal Reproduction
    • /
    • v.25 no.3
    • /
    • pp.287-292
    • /
    • 2001
  • Selection of oocyte cryopreseivation method is a prerequisite factor for developing an effective bank system. To develop an effective vitrification method, we examined whether damages in spindle and chromosome morphology induced by vitrification. Intact cumulus-enclosed oocytes were vitrified with DPBS with 5.5 M ethylene glycol and 1.0 M sucrose, and loaded onto eletron microscopic copper grid for storing in liquid nitrogen. Intact vitrified and thawed oocytes were immunostaining for tubulin and karyotying for chromosome. Vitrfied and thawed oocytes had a higher rate of chromosome (32.8% vs. 19.6%) and spindle (32.3% vs. 20.2%) abnormalities compared with fresh oocytes. Mouse oocytes after vitrification at the mature stage showed increased incidence of chromosomal and spindle abnormalities.

  • PDF

A Study on the Current Status of Baekje Parade Costume Shown in Festivals - Focusing on Hanseong Baekje Cultural Festival and Yeongam Wangin Cultural Festival - (축제에서 재현된 백제행렬복식의 현황연구 - 한성백제문화제와 영암왕인문화축제를 중심으로 -)

  • Ma, Yoo-Ree;Kim, Eun-Jung
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.17 no.2
    • /
    • pp.27-43
    • /
    • 2015
  • Festival costume shown in festival parades targeting historical events or figures helps to understand the theme of festival and grants visual effects and at the same time, is an important factor to identify then-cultural environment. Accordingly, this study aims to make a periodic review of traditional costumes used in parades for Hanseong Baekje Cultural Festival and Yeongam Wangin Cultural Festival which are both the festivals that backgrounded Baekje period, make a comparative analysis of the archetypes of reproduction costume vs Baekje costume, understand the problems of festival costume, and seek developmental directions. After making a comparative analysis of reproduction costume shown in festival parades, it was found that king costume, queen costume, governmental official costume, and humble class costume were all different from Baekje costume in terms of configuration, materials, color, shape, and creating method of costumes, and problems were drawn. When it comes to costume items, Pasul and Danryungpoh that didn't belong to Baekje period were worn. The problems in color research can be identified in governmental official costume. The problems in type of costume are shown in the length of po worn outside, margin of width, and degree of restoring accessories. Therefore, it seems to be necessary to convey and identify costume creating method by festival parade-related persons.

  • PDF

Air Tightness Performance of Residential Timber Frame Buildings

  • Kim, Hyun-Bae;Park, Joo-Saeng;Hong, Jung-Pyo;Oh, Jung-Kwon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.2
    • /
    • pp.89-100
    • /
    • 2014
  • Energy consumption statistics in 2005 from the Korea Energy Management Corporation show that building energy usage was about 24.2% of total domestic energy consumption, and 64% of total building energy usage was consumed by residential buildings. Thus, about 10% of total domestic energy consumption is due to the heating of residential buildings. Building energy can be calculated by the configuration of the building envelope and the rate of infiltration (the volume of the infiltration of outdoor air and the leakage of indoor air), and by doing so, the annual energy usage for heating and cooling. Therefore, air-tightness is an important factor in building energy conservation. This investigate air infiltration and various factors that decrease it in timber frame buildings and suggest ways to improve air-tightness for several structural types. Timber frame buildings can be classified into light frame, post and beam, and log house. Post and beam includes Han-ok (a Korean traditional building). Six light frame buildings, three post and beam buildings, one Korean traditional Han-ok and a log house were selected as specimens. Blower door tests were performed following ASTM E779-03. The light frame buildings showed the highest air-tightness, followed by post and beam structures, and last, log houses.

Experimental Study on the Damping Estimation of the 5×5 Partial Fuel Assembly (5×5 부분핵연료 집합체의 감쇠추정을 위한 실험적 연구)

  • Lee, Kang-Hee;Yoon, Kyung-Ho;Song, Kee-Nam
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.2 s.107
    • /
    • pp.163-168
    • /
    • 2006
  • The PWR Nuclear Fuel assembly consists of more than 250 fuel rods that are supported by leaf springs in the cells of more than 10 Spacer Grids (SG) along the rod length. Since it is not easy to conduct mechanical tests on a full-scale model basis, the small-scaled rod bundle $(5\times5)$ which is called partial fuel assembly is generally used for various performance tests during the development stage. As one of the small-scaled tests, a flow test should be carried out in order to verify the performance of the spacer grid to obtain the Flow-Induced Vibration (FIV) characteristics of the scaled fuel assembly over the specified flow range. A vibration test should be also performed to obtain the modal parameters of the assembly prior to the flow test. In this study, we want to develop the estimation procedure of the damping ratio for the scaled test assembly. For the damping factor of the partial fuel assembly and the grid cage at the first vibration mode, as one of the vibration tests, a so-called pluck testing has been performed in air as a preliminary test prior to in-flow damping measurement test. Logarithmic decrement method is used for calculation of the damping ratio. Estimated damping ratio of the partial fuel assembly is about $0.7\%$ with reasonable error of $2\%$ for the previous results. Nonlinear behavior of the partial fuel assembly might be stem mainly from the rod-grid support configuration.

Ground Vibration Test for Korea Sounding Rocket - III (KSR-III의 전기체 모달 시험)

  • 우성현;김영기;이동우;문남진;김홍배
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.441-447
    • /
    • 2002
  • KSR-III(Korea Sounding Rocket - III), which is being developed by Space Technology R&D Division of KARI(Korea Aerospace Research Institute) will be launched in late 2002. It is a three-stage, liquid propellant rocket which can reach 250 km altitude and will carry out observation of ozone layer and scientific experiments, such as microgravity experiment, and atmospheric measurement. KSR-III is believed to be an intermediate to the launch vehicle capable of carrying a satellite to its orbit. Space Test Department of KARI performed GVT(Ground Vibration Test) fer KSR-III EM at Rocket Test Building of KARI. GVT is very important for predicting the behavior of rocket in its operation, developing flight control program and performing aerodynamic analysis. This paper gives an introduction of rocket GVT configuration and information on test procedures, techniques and results of It. In this test. to simulate free-free condition, test object hung in the air laterally by 4 bungee cords specially devised. For the excitation of test object, pure random signal by two electromagnetic shakers was used and total 22 frequency response functions were achieved. Polyreference parameter estimation was performed to identify the modal parameters with MIMO(Multi-Input-Multi-Output) method. As the result of the test, low frequency mode shapes and modal parameters below 60Hz were identified

  • PDF

Electrical and Mechanical Noise Study of the 765kV Transmission Line (765kV 송전선로의 전기적 및 기계적 소음고찰)

  • Lee,
    • Journal of KSNVE
    • /
    • v.6 no.1
    • /
    • pp.89-95
    • /
    • 1996
  • If the transmission line voltage is greater than 500kV, audible noise (AN) and hum noise (HN) due to corona discharges on the conductor would be an important design factor for the conductor selection of transmission line. Also there is an aeolian noise: wind noise(WN) from the tower and the conductor due to wind. This paper presents the results of a statistical analysis of audible noise, hum noise, aeolian noise of 6-480mm$^{2}$ conductor bundle in KEPRI 765kV Test Transmission Line which was constructed to develop 765kV double circuit AC transmission line for the first time in the world. The result of the analysis shows that 6-480mm$^{2}$ conductor bundle and tower satisfy configuration the audible noise design criterion of 50dB(A).

  • PDF