• Title/Summary/Keyword: Configuration factor

Search Result 532, Processing Time 0.025 seconds

Precision Measurement of Silicon Wafer Resistivity Using Single-Configuration Four-Point Probe Method (Single-configuration FPP method에 의한 실리콘 웨이퍼의 비저항 정밀측정)

  • Kang, Jeon-Hong;Yu, Kwang-Min;Koo, Kung-Wan;Han, Sang-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1434-1437
    • /
    • 2011
  • Precision measurement of silicon wafer resistivity has been using single-configuration Four-Point Probe(FPP) method. This FPP method have to applying sample size, shape and thickness correction factor for a probe pin spacing to precision measurement of silicon wafer. The deference for resistivity measurement values applied correction factor and not applied correction factor was about 1.0 % deviation. The sample size, shape and thickness correction factor for a probe pin spacing have an effects on precision measurement for resistivity of silicon wafer.

Dependence of the Gain Factor of the Reflective Polarizer on the Configuration of Optical Sheets

  • Lee, Byung-Woo;Yu, Mi-Yeon;Ko, Jae-Hyeon
    • Journal of Information Display
    • /
    • v.10 no.1
    • /
    • pp.28-32
    • /
    • 2009
  • The correlation between the optical performance of the reflective polarizer, which is a key optical component for the brightness enhancement of the liquid crystal display (LCD), and the configuration of optical sheets was investigated in a direct-lit CCFL (cold-cathode fluorescent lamp) backlight. The optical gain of the reflective polarizer, the polarization state of the light emitted from each film, and the loss factor for the polarization conversion process occurring in the lower part of the backlight were determined using a phenomenological approach for the polarization recycling process. The present study suggests that the correlation between the optical performance of the brightness enhancement films and the backlight configuration should be carefully considered in the optimization of the backlight structure.

Configuration Management System for Rotorcraft Multi-Component Developement (회전익기 다품종부품 개발을 위한 형상관리 체계)

  • Kim, Hyun-Gi;Kim, Hwakbum;Kim, Sungchan
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.20 no.3
    • /
    • pp.35-43
    • /
    • 2012
  • Medium size rotorcraft consist of approximately 5,000 key components. The components must satisfy the target weight and performance requirement through optimization. Therefore a rotorcraft component has approximately 100 times higher unit cost for mass production than the equivalent of an automobile's, along with huge development cost. Configuration management consists of four main parts : configuration identification, configuration control, configuration audit, and data management. In development programme, configuration management is one of the methods to save development cost, and setting a well-structured configuration management system according to the Military Standard is an important factor in success of the programme. The paper proposes a configuration management system suitable for development of various multi-use components development and presents that the configuration management was performed successfully during dual-use component development programme using the established system.

Robust Analysis for Configuration of Redundant Intertial Sensors

  • Yang, Cheol-Kwan;Kim, Jeong-Yong;Shim, Duk-Sun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.116.4-116
    • /
    • 2001
  • We consider a robust configuration problem of inertial sensors for inertial navigation system(INS). Fault detection and isolation(FDI) is necessary to improve reliability of the system. For FDI, there used to be more than three mutually orthogonal sensors and thus we have to consider configuration methods of sensors. Various studies in this area have been done, but the former results did not consider effect of uncertainty(misalignment, scale factor error) to determine the configuration of the sensors. In this paper robust configuration of sensors is proposed through sensitivity analysis. Also total least square(TLS) method ...

  • PDF

Development of Optimal Control of Heliostat System Using Configuration Factor and Solar Tracking Device (형상계수와 태양추적장치를 이용한 헬리오스타트 제어 시스템 개발)

  • Lee, Dong Il;Jeon, Woo Jin;Baek, Seung Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.12
    • /
    • pp.1177-1183
    • /
    • 2012
  • This study aims to develop a system that maximizes the radiative heat transfer from the heliostat to the receiver by using the configuration factor and a solar tracking device. As the heat transfer from the heliostat to the receiver is delivered by solar radiation, the configuration factor commonly utilized for radiation is applied to control the heliostat. Tracking the sun and calculating its position are possible by using an illuminance sensor (CdS) and Simulink. By applying optimized algorithms programmed using Simulink that maximize the configuration factors among the heliostat, receiver, and sun in real time, the solar absorption efficiency of the receiver can be maximized. Simulations were performed on how to change the angle required to control the elevation and azimuthal angle of the heliostat during the daytime with respect to various distances.

Optimal Configuration of Redundant Inertial Sensors with Uncertainty (불확실성을 고려한 중복 관성센서의 최적 배치)

  • Shim Duk-Sun;Yang Cheol-Kwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.2
    • /
    • pp.81-86
    • /
    • 2005
  • In this paper we consider an optimal configuration problem for redundant inertial sensors which have uncertainty such as misalignment, scale factor error. The optimal configuration problem is treated from the viewpoint of navigation accuracy. We propose a necessary and sufficient condition for the optimal configuration of redundant sensors with no uncertainty, and a sufficient condition for the optimal configuration of redundant sensors with uncertainty. Finally we propose a condition for the optimal configuration based both navigation performance and FDI(fault detection and isolation).

Planning for Construction and Expanding of Distribution Substation Considering Contingency (상정사고를 고려한 배전용 변전소 신,증설 계획 수립)

  • Choi, Sang-Bong;Kim, Dae-Kyeong;Jeong, Seong-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.7
    • /
    • pp.303-308
    • /
    • 2001
  • This paper presents algorithm to plan construction and expanding of substation considering contingency accidents by proposing utilization factor according to configuration of substation bank system. In this paper, firstly, proper sphere of supply area by each district which could be standardized with respect to its supply capacity is established under assumption of long term load forecasting. Secondly, goal of utilization ratio based on configuration of substation bank was set to keep reliability by remaining sound bank when it happen to one bank accidents. Finally, it is set up for optimal construction and expanding of substation considering economy and reliability simultaneously about substation to exceed these ratio. To verify proposed algorithm, at first, after adopting a part of Kangnam area in Seoul as area for testing, it is divided into several regions for this area according to power branches of power utility. Secondly, by deriving correlation factor between load demand and economic indicators in these region respectively, the regional load forecasting was performed with economic growth and city plan scenario. Finally, based on the predicted load demand by region and land use data which is identified from air-photographic, the load demand by district was predicted. Also, planning for substation considering contingency is formulated to expand taking into account computing utilization factor which is based on configuration of substation bank respectively.

  • PDF

Power Factor Correction of Single-phase Boost Converter for Low-cost Type UPS Configuration (저 가격형 UPS를 구성하기 위한 단상 부스트 컨버터의 고 역률 제어)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.3
    • /
    • pp.145-150
    • /
    • 2013
  • A novel AC to DC PWM converters with unity input power factor are proposed to overcome the above shortcoming. The main function of these converters is to shape the input line current to force it exactly in phase with the input AC voltage. Therefore, the input power factor can be improved to near unity and the input current harmonics can be eliminated. In this paper, half-bridge converter with two active switches and two diodes are utilized for low-cost type UPS configuration. By having only two semiconductors in the current path at any time, losses can be reduced over the conventional boost topology. Also, this converter provides controllable dc-link voltage, high power factor, and low cost type converter by simple power circuits. Simulation results show that the proposed half-bridge converter/inverter control technique can be applied to single-phase low-cost type UPS systems successfully.

The Relation Between Magnetic Field Configuration And The Flux Expansion Factor

  • Lee, Hwan-Hee;Magara, Tetsuya;An, Jun-Mo;Kang, Ji-Hye
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.85.1-85.1
    • /
    • 2012
  • In this study we use three-dimensional magnetohydrodynamic simulations of flux emergence from solar subsurface layer to corona. In order to study the twist parameter of magnetic field we compare the simulations for strongly twisted and weakly twisted cases. Based on the results, we derive a flux expansion factor of selected flux tubes which is a ratio of expanded cross section to the one measured at the footpoint of the flux tube. To understand the effect of flux expansion factor, we make a comparison between magnetic field configuration and the expansion factor. By using a fitting function of hyperbolic tangent we derive noticeable correlations among the strength of the vertical magnetic field, current density and expansion factor. We discuss what these results tell about the relationship between the twist of emerging field and the mechanism for the solar wind.

  • PDF

A Fast Algorithm of the Apparent Factor Calculation for Distance Relay Setting without Fault Analysis

  • Jo, Yong-Hwan;Xiang, Ling;Choi, Myeon-Song;Park, Ji-Seung;Lim, Seong-Il;Kim, Sang-Tae;Lee, Seung-Jae
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.64-69
    • /
    • 2013
  • For power system protection, the distance relay settings are important. Apparent factor is a necessary parameter in distance relay settings. Apparent factors have to be calculated when setting the distance relays and doing the resetting in case of configuration change in power system. The problem is that the current method to calculate apparent factor requires tools and plenty of time to do fault analysis and this method is complex especially in case of configuration change. Therefore this paper proposes a fast algorithm to calculate apparent factor without the fault analysis. Test results prove that this algorithm is simple and accurate by simulation.