• Title/Summary/Keyword: Confidence of Performance

Search Result 1,109, Processing Time 0.038 seconds

Maintenance of Platelet Counts with Low Level QC Materials and the Change in P-LCR according to Hemolysis with XN-9000 (XN-9000장비에서 Low Level QC물질에서의 혈소판 수 관리와 용혈에 따른 P-LCR의 변화)

  • Shim, Moon-Jung;Lee, Hyun-A
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.4
    • /
    • pp.399-405
    • /
    • 2018
  • The platelet count in clinical laboratories is essential for the diagnosis and treatment of hemostasis abnormalities, and accurate platelet counting in the low count range is of prime importance for deciding if a platelet transfusion is needed and for monitoring after chemotherapy. Quality control is designed to reduce and correct any deficiencies in the internal analytical process of a clinical laboratory prior to the release of patient results. Fragmented erythrocytes are the major confusing factors for platelet counting because of their similar size to platelets. The authors found that the low range QC values were out of 2SD with a Sysmex automatic analyzer in internal quality control process. Thus far, there has been little discussion on the relationship between hemolysis and the platelet parameters. Therefore, this study focused on the performance of automated platelet counts, including the PLT-F, the PLT-I, and PLT-O methods at the low platelet range using the low level QC materials and compared the 5 platelet parameters with the hemolyzed samples. The results showed that the CV was the smallest with PLT-F and P-LCR increased from 18.4 to 31.9% in the hemolysis samples. These results indicate that a more accurate estimation of the platelet counts can be achieved using the PLT-F method than the PLT-I method at the low platelet range. The use of the PLT-F system improves the confidence of results in low platelets samples in a routine hematology laboratory. The results suggest that P-LCR is a new parameter in assessing samples when the specimen is suspected of hemolysis and deterioration. Nevertheless, further studies will be needed to establish the relationship with P-LCR and hemolysis using human blood specimens.

Use of Artificial Intelligence for Reducing Unnecessary Recalls at Screening Mammography: A Simulation Study

  • Yeon Soo Kim;Myoung-jin Jang;Su Hyun Lee;Soo-Yeon Kim;Su Min Ha;Bo Ra Kwon;Woo Kyung Moon;Jung Min Chang
    • Korean Journal of Radiology
    • /
    • v.23 no.12
    • /
    • pp.1241-1250
    • /
    • 2022
  • Objective: To conduct a simulation study to determine whether artificial intelligence (AI)-aided mammography reading can reduce unnecessary recalls while maintaining cancer detection ability in women recalled after mammography screening. Materials and Methods: A retrospective reader study was performed by screening mammographies of 793 women (mean age ± standard deviation, 50 ± 9 years) recalled to obtain supplemental mammographic views regarding screening mammography-detected abnormalities between January 2016 and December 2019 at two screening centers. Initial screening mammography examinations were interpreted by three dedicated breast radiologists sequentially, case by case, with and without AI aid, in a single session. The area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and recall rate for breast cancer diagnosis were obtained and compared between the two reading modes. Results: Fifty-four mammograms with cancer (35 invasive cancers and 19 ductal carcinomas in situ) and 739 mammograms with benign or negative findings were included. The reader-averaged AUC improved after AI aid, from 0.79 (95% confidence interval [CI], 0.74-0.85) to 0.89 (95% CI, 0.85-0.94) (p < 0.001). The reader-averaged specificities before and after AI aid were 41.9% (95% CI, 39.3%-44.5%) and 53.9% (95% CI, 50.9%-56.9%), respectively (p < 0.001). The reader-averaged sensitivity was not statistically different between AI-unaided and AI-aided readings: 89.5% (95% CI, 83.1%-95.9%) vs. 92.6% (95% CI, 86.2%-99.0%) (p = 0.053), although the sensitivities of the least experienced radiologists before and after AI aid were 79.6% (43 of 54 [95% CI, 66.5%-89.4%]) and 90.7% (49 of 54 [95% CI, 79.7%-96.9%]), respectively (p = 0.031). With AI aid, the reader-averaged recall rate decreased by from 60.4% (95% CI, 57.8%-62.9%) to 49.5% (95% CI, 46.5%-52.4%) (p < 0.001). Conclusion: AI-aided reading reduced the number of recalls and improved the diagnostic performance in our simulation using women initially recalled for supplemental mammographic views after mammography screening.

A Study on Estimating Route Travel Time Using Collected Data of Bus Information System (버스정보시스템(BIS) 수집자료를 이용한 경로통행시간 추정)

  • Lee, Young Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.1115-1122
    • /
    • 2013
  • Recently the demands for traffic information tend to increase, and travel time might one of the most important traffic information. To effectively estimate exact travel time, highly reliable traffic data collection is required. BIS(Bus Information System) data would be useful for the estimation of the route travel time because BIS is collecting data for the bus travel time on the main road of the city on real-time basis. Traditionally use of BIS data has been limited to the realm of bus operating but it has not been used for a variety of traffic categories. Therefore, this study estimates a route travel time on road networks in urban areas on the basis of real-time data of BIS and then eventually constructs regression models. These models use an explanatory variable that corresponds to bus travel time excluding service time at the bus stop. The results show that the coefficient of determination for the constructed regression model is more than 0.950. As a result of T-test performance with assistance from collected data and estimated model values, it is likely that the model is statistically significant with a confidence level of 95%. It is generally found that the estimation for the exact travel time on real-time basis is plausible if the BIS data is used.

A Study on the Properties of Foamed Concrete with Plaster Using the Experimental Design (실험계획법을 이용한 석고 혼입 기포콘크리트의 특성에 관한 연구)

  • Lee, Sang-An;Kim, Wha-Jung;Yoon, Sang-Chun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.6
    • /
    • pp.130-137
    • /
    • 2013
  • This research was performed through the experimental design to get the statistical analysis on foamed concrete mixed plaster with hydrogen peroxide. In this experiment, we set the ratio of each material, which part of lightweight concrete, as experimental factors and evaluated on the mechanical properties by statistical analysis for response variables obtained from experiments. Experimental factors are plaster replacement, water binder ratio, and hydrogen peroxide ratio. Response variables are dry density, compressive strength, and flexural strength. Mixing design of the foamed concrete set up a total of 15 experimental points by Box-Behnken (BB) method of the response surface analysis. Thus, the results of a study were summarized as follows. Values of the probability in experimental factors (plaster replacement, water binder ratio and hydrogen peroxide ratio) on the response variables were estimated to be significant at the 95% of confidence limit. On response surface analysis for dry density of foamed concrete, water binder ratio and hydrogen peroxide ratio were estimated to be significant (${\alpha}$ = 0.05), and the relationship between the amount of void and the water content for dry density is inverse proportional. On response surface analysis for the compressive strength of foamed concrete, water binder ratio, hydrogen peroxide ratio and (hydrogen peroxide ratio)$^2$ was estimated to be significant (${\alpha}$ = 0.05). On response surface analysis for the flexural strength of foamed concrete, water binder ratio, hydrogen peroxide ratio was estimated to be significant (${\alpha}$ = 0.05). Through multi response surface analysis, we found the optimal area that meets performance goals.

Implementation of LDPC Decoder using High-speed Algorithms in Standard of Wireless LAN (무선 랜 규격에서의 고속 알고리즘을 이용한 LDPC 복호기 구현)

  • Kim, Chul-Seung;Kim, Min-Hyuk;Park, Tae-Doo;Jung, Ji-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.12
    • /
    • pp.2783-2790
    • /
    • 2010
  • In this paper, we first review LDPC codes in general and a belief propagation algorithm that works in logarithm domain. LDPC codes, which is chosen 802.11n for wireless local access network(WLAN) standard, require a large number of computation due to large size of coded block and iteration. Therefore, we presented three kinds of low computational algorithms for LDPC codes. First, sequential decoding with partial group is proposed. It has the same H/W complexity, and fewer number of iterations are required with the same performance in comparison with conventional decoder algorithm. Secondly, we have apply early stop algorithm. This method reduces number of unnecessary iterations. Third, early detection method for reducing the computational complexity is proposed. Using a confidence criterion, some bit nodes and check node edges are detected early on during decoding. Through the simulation, we knew that the iteration number are reduced by half using subset algorithm and early stop algorithm is reduced more than one iteration and computational complexity of early detected method is about 30% offs in case of check node update, 94% offs in case of check node update compared to conventional scheme. The LDPC decoder have been implemented in Xilinx System Generator and targeted to a Xilinx Virtx5-xc5vlx155t FPGA. When three algorithms are used, amount of device is about 45% off and the decoding speed is about two times faster than convectional scheme.

The Effect of Education on Motor Skill Assessment Tool for Occupational Therapists (작업치료사를 위한 운동성 평가도구의 교육효과)

  • Choi, Jeong-sil;Kim, Min-Joo
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.10 no.2
    • /
    • pp.63-72
    • /
    • 2020
  • Objective : The purpose of this study is to investigate the effect of intensive one-day training on Movement Assessment Battery for Children-2 screening developmental coordination disorder. Methods : We provided intensive one-day training which combined lecture and practice on MABC-2 assessment tools for 33 trainees. Interrater reliability was calculated by using Intraclass correlation coefficient (ICC) with the raw score of results scored simultaneously by experts and trainees of MABC-2. Results : The 33 female trainees with an average of five years and three months of experience and less experience using motor skill assessment tools scored raw score while watching the performance scenes of normal children. The results of the ICC between experts and training participants in MABC-2 obtained a high confidence 0.95 and above (p<.001). Conclusion : Clinicians who participated in one-day training seems to use MABC-2 effectively. Through this, one-day training seems to be effective in acquiring new motor skill assessment tools.

Feasibility Study on the Methodology of Test and Evaluation for UAV Positioning (무인항공기 위치정확도 시험평가 기법 연구)

  • Ju, Yo-han;Moon, Kyung-kwan;Kang, Bong-seok;Jeong, Jae-won;Son, Han-gi;Cho, Jeong-hyun
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.6
    • /
    • pp.530-536
    • /
    • 2018
  • Recently, many studies for interoperability of UAV in the NAS has been performed since the application range and demand of UAV are continuously increased. For the interoperation of UAV in the NAS, technical standards and certification system for UAV which is equivalent to the commercial aircraft are required and test and evaluation methodology must be presented by standards. In this paper, qualification test and evaluation methodology aboutfor the UAV navigation system is proposed. For the research, the mission profile and operation environment of UAV were analyzed. Thereafter the test criteria were derived and the test methodology were established. Finally, the simulation and demonstration using test-bed UAV were performed. As a result of the test, it was confirmed that the navigation system of test UAV has a position accuracy about 1.4 meters at 95% confidence level in the entire flight stage.

Bioequivalence of pioglitazone tablet to Actos® tablet (Pioglitazone 30 mg) (액토스정®(피오글리타존 30 mg)에 대한 염산피오글리타존정의 생물학적동등성)

  • Yeom, Hyesun;Lee, Tae Ho;Youm, Jeong-Rok;Song, Jin-Ho;Han, Sang Beom
    • Analytical Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.101-108
    • /
    • 2009
  • The bioequivalence of two pioglitazone tablets, Actos$^{(R)}$ tablet (Takeda Chemical Industries, reference drug) and Pioglitazone tablet (Boryung Company, test drug) was evaluated according to the guidelines of Korea Food and Drug Administration. Twenty-eight healthy male Korean volunteers received each medicine (pioglitazone dose of 30 mg) in a $2{\times}2$ crossover study with one week washout interval. After drug administration, blood samples were collected at specific time intervals from 0-36 hours. The plasma concentrations of pioglitazone were determined by high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). The total chromatographic run time was 5 min and calibration curves were linear over the concentration range of 5-2000 ng/mL for pioglitazone. The method was validated for selectivity, sensitivity, linearity, accuracy and precision. The pharmacokinetic parameters were determined from the plasma concentration-time profiles of both formulations. The primary calculated pharmacokinetic parameters were compared statistically to evaluate bioequivalence between the two preparations. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for Pioglitazone tablet and Actos$^{(R)}$ tablet were log0.9422~log1.1040 and log0.9200~log1.1556, respectively. Based on the statistical considerations, we can conclude that the test drug, Pioglitazone tablet was bioequivalent to the reference drug, Actos$^{(R)}$ tablet.

A Study on Mitigation of Psychological Instability of Soldiers by Direct Exposure to the SMR Wave (감각운동 리듬(SMR파)파 직접노출에 의한 심리적 불안상태 해소에 관한 연구)

  • Kim, Kyoung-Lae;Kim, Koo-Bum;Cho, Seok-Su;Park, Jung Soon;Kim, Hyung Jun;Yeo, Sun Gu;Min, Byeong Chan
    • Science of Emotion and Sensibility
    • /
    • v.22 no.3
    • /
    • pp.103-108
    • /
    • 2019
  • Although the Korean Armistice Agreement resulted in complete cessation of the hostilities of the Korean War, it also initiated a rule that obligates Korean men to compulsorily participate in military service. However, psychological factors such as anxiety, stress, and negative perception among the young participants joining the military lead to inefficiency in training and performance. Several types of media production companies have been tasked to deal with this problem. However, their tools have not adequately addressed the root causes of the psychological distress. Stress rates are still high among the youth. This paper offers a method of reducing anxiety and psychological stress among those joining the military. It also aims to help improve concentration and cope with the pessimism of military life. The study measured the increase in concentration as well as the changing rate of anxiety and psychological stress in the participants of two experimental groups. A significant result with t = 2.487, p = 0.042, and 95% confidence levels was revealed by analyzing the data pertaining to the experimental group that was directly exposed to the sensorimotor rhythm (SMR) wave implying that this brain wave alleviated feelings of anxiety and psychological stress. The method proposed in this paper can thus be applied to mitigate stress in soldiers and help them with their personal and military lives. Further interdisciplinary experiments examining the associations between the electrocardiogram and electroencephalogram are required.

Estimation of Measurement Uncertainty for the HPLC Analysis of Deoxynivalenol in Wheat (밀에서 HPLC에 의한 데옥시니발레놀 분석의 측정불확도 산정)

  • Ok, Hyun-Ee;Chang, Hyun-Joo;Ahn, Jang-Hyuk;Cho, Jae-Young;Chun, Hyang-Sook
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.3
    • /
    • pp.258-264
    • /
    • 2009
  • The principal objective of this study was to estimate the measurement uncertainty associated with determination of deoxynivalenol (DON), a mycotoxin generated by Fusarium strain, in food. In service of this goal, wheat as a food matrix was analyzed via high performance liquid chromatography-ultraviolet (HPLC-UV) detection using an immunoaffinity column for clean-up. The uncertainty sources in the measurement process were identified by sample weight, final volume, and sample concentration in extraction volume with components including standard stock solution, working standard solution, 5 standard solutions, calibration curve, matrix, and instrument. The expanded uncertainty for DON at a concentration of 300 ${\mu}g/kg$ was estimated as 71.62 ${\mu}g/kg$ using a coverage factor of two, which provides a confidence level of approximately 95%. The most influential component in the uncertainty sources was the recovery of the wheat matrix, followed by the calibration curve. These results indicate that all efforts may be directed toward reducing the uncertainties of the recovery of the wheat matrix and the calibration curve to obtain a reliable HPLC-UV method for DON analysis in wheat.