• Title/Summary/Keyword: Confidence cone

Search Result 26, Processing Time 0.029 seconds

Bootstrap Confidence Cones for Spherical Data (구형자료(球型資料)에 대(對)한 부트스트랩 신뢰원추체(信賴圓錐體))

  • Shin, Yang-Kyu
    • Journal of the Korean Data and Information Science Society
    • /
    • v.3 no.1
    • /
    • pp.33-46
    • /
    • 1992
  • The set of eigenvectors of the second moment matrix and the mean vector are the measures of orientation for a distribution supported on the unit sphere. Bootstrap confidence cone for the eigenvector is constructed and the consistency of this method is discussed. The performance of our bootstrap cone for the eigenvector is compared with that of the asymptotic confidence cones for two measures under the parametric assumptions for the underlying distributions and that of the bootstrap cone for the mean vector by Monte Carlo simulation.

  • PDF

Double Bootstrap Confidence Cones for Sphericla Data based on Prepivoting

  • Shin, Yang-Kyu
    • Journal of the Korean Statistical Society
    • /
    • v.24 no.1
    • /
    • pp.183-195
    • /
    • 1995
  • For a distribution on the unit sphere, the set of eigenvectors of the second moment matrix is a conventional measure of orientation. Asymptotic confidence cones for eigenvector under the parametric assumptions for the underlying distributions and nonparametric confidence cones for eigenvector based on bootstrapping were proposed. In this paper, to reduce the level error of confidence cones for eigenvector, double bootstrap confidence cones based on prepivoting are considered, and the consistency of this method is discussed. We compare the perfomances of double bootstrap method with the others by Monte Carlo simulations.

  • PDF

Does cone-beam CT alter treatment plans? Comparison of preoperative implant planning using panoramic versus cone-beam CT images

  • Guerrero, Maria Eugenia;Noriega, Jorge;Castro, Carmen;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.121-128
    • /
    • 2014
  • Purpose: The present study was performed to compare the planning of implant placement based on panoramic radiography (PAN) and cone-beam computed tomography (CBCT) images, and to study the impact of the image dataset on the treatment planning. Materials and Methods: One hundred five partially edentulous patients (77 males, 28 females, mean age: 46 years, range: 26-67 years) seeking oral implant rehabilitation were referred for presurgical imaging. Imaging consisted of PAN and CBCT imaging. Four observers planned implant treatment based on the two-dimensional (2D) image data-sets and at least one month later on the three-dimensional (3D) image dataset. Apart from presurgical diagnostic and dimensional measurement tasks, the observers needed to indicate the surgical confidence levels and assess the image quality in relation to the presurgical needs. Results: All observers confirmed that both imaging modalities (PAN and CBCT) gave similar values when planning implant diameter. Also, the results showed no differences between both imaging modalities for the length of implants with an anterior location. However, significant differences were found in the length of implants with a posterior location. For implant dimensions, longer lengths of the implants were planned with PAN, as confirmed by two observers. CBCT provided images with improved scores for subjective image quality and surgical confidence levels. Conclusion: Within the limitations of this study, there was a trend toward PAN-based preoperative planning of implant placement leading towards the use of longer implants within the posterior jaw bone.

Optimizing cone-beam computed tomography exposure for an effective radiation dose and image quality balance

  • Ananda Amaral Santos;Brunno Santos de Freitas Silva;Fernanda Ferreira Nunes Correia;Eleazar Mezaiko;Camila Ferro de Souza Roriz;Maria Alves Garcia Silva;Deborah Queiroz Freitas;Fernanda Paula Yamamoto-Silva
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.159-169
    • /
    • 2024
  • Purpose: The aim of this study was to evaluate the influence of different cone-beam computed tomography (CBCT) acquisition protocols on reducing the effective radiation dose while maintaining image quality. Materials and Methods: The effective dose emitted by a CBCT device was calculated using thermoluminescent dosimeters placed in a Rando Alderson phantom. Image quality was assessed by 3 experienced evaluators. The relationship between image quality and confidence was evaluated using the Fisher exact test, and the agreement among raters was assessed using the kappa test. Multiple linear regression analysis was performed to investigate whether the technical parameters could predict the effective dose. P-values<0.05 were considered to indicate statistical significance. Results: The optimized protocol (3 mA, 99 kVp, and 450 projection images) demonstrated good image quality and a lower effective dose for radiation-sensitive organs. Image quality and confidence had consistent values for all structures (P<0.05). Multiple linear regression analysis resulted in a statistically significant model. The milliamperage (b=0.504; t=3.406; P=0.027), kilovoltage peak (b=0.589; t=3.979; P=0.016) and number of projection images (b=0.557; t=3.762; P=0.020) were predictors of the effective dose. Conclusion: Optimized CBCT acquisition protocols can significantly reduce the effective radiation dose while maintaining acceptable image quality by adjusting the milliamperage and projection images.

An extremum method for bending-wrinkling predictions of inflated conical cantilever beam

  • Wang, Changguo;Du, Zhenyong;Tan, Huifeng
    • Structural Engineering and Mechanics
    • /
    • v.46 no.1
    • /
    • pp.39-51
    • /
    • 2013
  • An extremum method is presented to predict the wrinkling characteristics of the inflated cone in bending. The wrinkling factor is firstly defined so as to obtain the wrinkling condition. The initial wrinkling location is then determined by searching the maximum of the wrinkling factor. The critical wrinkling load is finally obtained by determining the ratio of the wrinkling moment versus the initial wrinkling location. The extremum method is proposed based on the assumption of membrane material of beam wall, and it is extended to consider beam wall with thin-shell material in the end. The nondimensional analyses show that the initial wrinkling location is closely related to the taper ratio. When the taper ratio is higher than the critical value, the initial wrinkles will be initiated at a different location. The nondimensional critical wrinkling load nonlinearly increases as the taper ratio increases firstly, and then linearly increases after the critical taper ratio. The critical taper ratio reflects the highest load-carrying efficiency of the inflated cone in bending, and it can be regarded as a measure to optimize the geometry of the inflated cone. The comparative analysis shows fairly good agreement between analytical and numerical results. Over the whole range of the comparison, the mean differences are lower than 3%. This gives confidence to use extremum method for bending-wrinkling analysis of inflated conical cantilever beam.

다목적 콘 관입시험기의 활용

  • Bae, Myeong-Ho;Yoon, Hyung-Koo;Kim, Ju-Han;Lee, Jong-Sub
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.163-170
    • /
    • 2010
  • Today, In-Situ testing for measureing geotechnical characterization are divided by Cone Penetration Test, Standard Penetration Test and Dilatometer Test, and will vary depending on soil conditions have been applied (Korea Geotechnical Engineering, 2006). However, these methods can be applied on sand or soft clay soil. Now, many studies are progressing for evaluating the stiffness characteristic of rocks and IGM. and Nam moon suk(2006) did Texas Cone Penetrometer Test for designing field penetration pile intruded at rocks and IGM. but, reliability of Texas Cone Penetration Test has confidence limits because TCPT is testing in Texas centrally, and energy dose not measure Woojin Lee, etc. (1998) did calculate Standard Penetration Test Hammer's dynamic energy efficiency by using dongjaeha analyzer. this research, we installed strain gage and accelerometer for supply existing equipment, and develop MCP that can use variety soils. this thesis, we measured energy at head and tip of Rod for evaluating energy that transport at free falling. As a result, Energy differences are occurred at head and tip of Rod.

  • PDF

Use of preoperative cone-beam computed tomography to aid in establishment of endodontic working length: A systematic review and meta-analysis

  • Paterson, Andrew;Franco, Vittorio;Patel, Shanon;Foschi, Federico
    • Imaging Science in Dentistry
    • /
    • v.50 no.3
    • /
    • pp.183-192
    • /
    • 2020
  • Purpose: This study was performed to assess the accuracy of preoperative cone-beam computed tomography (CBCT), when justified for other reasons, in locating the apical foramen and establishing the working length. Materials and Methods: Six electronic databases were searched for studies on this subject. All studies, of any type, were included if they compared measurements of working length with preoperative CBCT to measurements using an electronic apex locator (EAL) or histological reference standard. Due to the high levels of heterogeneity, an inverse-variance random-effects model was chosen, and weighted mean differences were obtained with 95% confidence intervals and P values. Results: Nine studies were included. Compared to a histological reference standard, CBCT indicated that the apical foramen was on average 0.40 mm coronal of its histological position, with a mean absolute difference of 0.48 mm. Comparisons were also performed to an EAL reference standard, but the conclusions could not be considered robust due to high levels of heterogeneity in the results. Conclusion: A low level of evidence is produced suggesting that preoperative CBCT shows the apical foramen to be on average 0.40 mm coronal to its histological position, with a mean absolute difference of 0.48 mm.

A Study on the Determination of Depth of Soft Ground by Cone Resistance (피조콘 관입저항치($q_c$)를 이용한 연약지반 심도결정에 관한 연구)

  • 신윤섭;김민철;김연정;김영웅
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.701-708
    • /
    • 2003
  • Recently, piezocone penetration test is frequently conformed in order to estimate the characteristics of soft ground with standard penetration test, generally used in the past. The soil characteristics, such as cone penetration resistance, friction resistence and excessive pore water pressure, can be evaluated continuously through the piezocone penetration test. In Incheon International Airport 2nd phase site preparation, standard penetration test and piezocone penetration test were used in order to increase the confidence for determination of soft ground depth. And the compressible layer was determined by the comparison between the preconsolidation pressure and the designed increase pressure. As the results, the relation between standard penetration test and piezocone penetration test shows q$_{c}$=(1.09~l.63)N at the soft ground, determined by 5/30 N value. And q$_{c}$=(1.21~l.98)N was shown at the point of compressible layer, evaluated by the preconsolidation pressure. These results were applied to determination for the depth of soft ground and to design the improvement for the soft clay.lay.

  • PDF

Accuracy and reliability of stitched cone-beam computed tomography images

  • Egbert, Nicholas;Cagna, David R.;Ahuja, Swati;Wicks, Russell A.
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.41-47
    • /
    • 2015
  • Purpose: This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Material and Methods: Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer's imaging software. The same measurements were then taken with the CBCT software. Results: The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study. Conclusion: The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.

A Study on the Determination of Construction Depth of Vertical Drain by Cone Resistance (콘 관입저항치를 이용한 수직배수재 타설심도 결정에 관한 연구)

  • Kim, Yeon-Jung;Kim, Nam-Ho;Shin Yun-Sup
    • 기술발표회
    • /
    • s.2006
    • /
    • pp.261-269
    • /
    • 2006
  • Recently, piezocone penetration test is frequently used in order to estimate the characteristics of soft ground with standard penetration test; generally used in the past In this study, standard penetration test, piezocone penetration test, driving resistance of vertical drain were used in order to increase the confidence for determination of soft ground depth. And the compressible layer was determined by the comparison between the preconsolidation pressure and the designed increase pressure. As the results, the relation between standard penetration test and piezocone penetration test shows $q_c$=(1.09~1.63)N at the soft ground, determined by 5/30 N value. And $q_c$(1.21~1.98)N was shown at the point of compressible layer, evaluated by the preconsolidation pressure. And driving resistance of vertical drain is 70 f/$cm^2$ which is equal to 10kgf/$cm^2$ cone penetration resistance.

  • PDF