• 제목/요약/키워드: Cone penetration resistance

검색결과 111건 처리시간 0.024초

Applicability of Mini-Cone Penetration Test Used in a Soil Box

  • Sugeun Jeong;Minseo Moon;Daehyeon Kim
    • 한국지반신소재학회논문집
    • /
    • 제22권4호
    • /
    • pp.83-92
    • /
    • 2023
  • In this study, we conducted verification of key influencing factors during cone penetration testing using the developed Mini Cone Penetration Tester (Mini-CPT), and compared the experimental results with empirical formulas to validate the equipment. The Mini-CPT was designed to measure cone penetration resistance through a Strain Gauge, and the resistance values were calibrated using a Load Cell. Moreover, the influencing factors were verified using a model ground constituted in a soil box. The primary influencing factors examined were the boundary effect of the soil box, the distance between cone penetration points, and the cone penetration speed. For the verification of these factors, the experiment was conducted with the model ground having a relative density of 63.76% in the soil box. It was observed that the sidewall effect was considerably significant, and the cone penetration resistance measured at subsequent penetration points was higher due to the influence between penetration points. However, within the speed range considered, the effect of penetration speed was almost negligible. The measured cone penetration resistance was compared with predicted values obtained from literature research, and the results were found to be similar. It is anticipated that using the developed Mini-CPT for constructing model grounds in the laboratory will lead to more accurate geotechnical property data.

소형콘의 관입저항력을 이용한 점토의 액성한계측정에 관한 연구 (Study on the Measurement of Liquid Limit Using a Penetration Resistance of Small Cone in Clay Soil)

  • 손무락;이재용
    • 한국지반공학회논문집
    • /
    • 제32권10호
    • /
    • pp.5-15
    • /
    • 2016
  • 본 연구에서는 소형콘의 관입저항력을 이용한 점토의 액성한계를 측정하기 위하여 카올리나이트 점토와 벤토나이트 점토의 비율을 다양하게 혼합한 점토흙에 대하여 함수비와 소형콘의 관입저항력을 조사하고 기존의 동적(Casagrande 시험법) 및 정적(Fall cone 시험법) 액성한계 시험결과와 직접 비교하였다. 비교결과 다양한 점토흙의 함수비에 따른 관입저항력 관계곡선에서 변곡점이 형성된다는 것을 파악하였으며 이 때의 함수비가 정적액성한계(Fall cone)시험법에 의한 액성한계 값과 매우 유사함을 파악하였다. 변곡점이 형성된 점에서의 소형콘의 관입저항력은 약 0.2kPa로 나타났으며 이 때 의 함수비가 점토흙의 액성한계를 나타낸다는 것을 확인하였다. 이와 같은 연구결과를 토대로 향후 점토의 액성한계를 파악하는데 본 연구에서 조사된 0.2kPa의 소형콘의 관입저항력이 유용한 지표가 될 수 있다는 사실을 파악하였다. 또한 소형콘의 관입저항력을 이용한 액성한계 시험법을 제시하였다.

조석 영향에 의한 해성준설토의 강도변화 특성에 관한 연구 (Characteristics of the Strength Change of Dredged Soil by Tide Influence)

  • 천병식;김봉수;이원택;도종남
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.1071-1074
    • /
    • 2008
  • In this study, the behavior of dredged soil was measured by repeated tide and analyzed the change of settlements and cone penetration resistance by centrifuge model about dredged soil of Kunsan-Janghang site that maximum tidal range is 7.4m. Consequently the settlements of dredged soil by repeated tide in the 2nd month was 0.489 m. After 12th month, the total settlements was 0.524 m in the model. It meaned the settlements of dredged soil by repeated tide in the 2th month was 80% of the settlements. Also, with the lapse of time, cone penetration resistance increased centrifuge model test for catching the strength change of dredged soil by repeated tide. After 10th month, there were not almost changes. cone penetration resistance in 10th month was measured more 3.5~5.6 times than that in its early stages. Also, with the lapse of time, cone penetration resistance increased almost linearly. And, when we surveyed the relation between cone penetration resistance and time, as depth increased, cone penetration resistance rose.

  • PDF

Arbitrary Lagrangian-Eulerian 기법에 의거한 콘 관입 해석 (An Analysis of Cone Penetration Based on Arbitrary Larangian-Eulerian Method)

  • Oh, Se-Boong
    • 한국지반공학회논문집
    • /
    • 제17권6호
    • /
    • pp.85-98
    • /
    • 2001
  • Arbitrary Lagrangian-Eulerian(ALE) 기법에 의거하여 콘 관입문제를 해석하였다. 완전한 관입을 모의하기 위하여 ABAQUS/Explicit을 이용하여 지반의 상향 유동을 모델링하는 정상상태해석(steady state analysis)을 수행하였다. 단일 지층의 해석에서는 흙 입자의 유동 경로와 변형률이 strain path method와 일관된 결과를 나타내고 있음을 확인하였고 극한저항을 합리적으로 계산할 수 있었다. 상이한 지층에 콘을 관입하는 경우에 대해서도 콘 저항이 전이하는 경향을 해석할 수 있었다. 따라서 ALE 해법의 정상상태해석으로 층상 지층에 대한 완전한 관입을 해석할 수 있었다.

  • PDF

Characterization of railway substructure using a hybrid cone penetrometer

  • Byun, Yong-Hoon;Hong, Won-Taek;Lee, Jong-Sub
    • Smart Structures and Systems
    • /
    • 제15권4호
    • /
    • pp.1085-1101
    • /
    • 2015
  • Changes in substructure conditions, such as ballast fouling and subgrade settlement may cause the railway quality deterioration, including the differential geometry of the rails. The objective of this study is to develop and apply a hybrid cone penetrometer (HCP) to characterize the railway substructure. The HCP consists of an outer rod and an inner mini cone, which can dynamically and statically penetrate the ballast and the subgrade, respectively. An accelerometer and four strain gauges are installed at the head of the outer rod and four strain gauges are attached at the tip of the inner mini cone. In the ballast, the outer rod provides a dynamic cone penetration index (DCPI) and the corrected DCPI (CDCPI) with the energy transferred into the rod head. Then, the inner mini cone is pushed to estimate the strength of the subgrade from the cone tip resistance. Laboratory application tests are performed on the specimen, which is prepared with gravel and sandy soil. In addition, the HCP is applied in the field and compared with the standard dynamic cone penetration test. The results from the laboratory and the field tests show that the cone tip resistance is inversely proportional to the CDCPI. Furthermore, in the subgrade, the HCP produces a high-resolution profile of the cone tip resistance and a profile of the CDCPI in the ballast. This study suggests that the dynamic and static penetration tests using the HCP may be useful for characterizing the railway substructure.

Cone penetrometer incorporated with dynamic cone penetration method for investigation of track substructures

  • Hong, Won-Taek;Byun, Yong-Hoon;Kim, Sang Yeob;Lee, Jong-Sub
    • Smart Structures and Systems
    • /
    • 제18권2호
    • /
    • pp.197-216
    • /
    • 2016
  • The increased speed of a train causes increased loads that act on the track substructures. To ensure the safety of the track substructures, proper maintenance and repair are necessary based on an accurate characterization of strength and stiffness. The objective of this study is to develop and apply a cone penetrometer incorporated with the dynamic cone penetration method (CPD) for investigating track substructures. The CPD consists of an outer rod for dynamic penetration in the ballast layer and an inner rod with load cells for static penetration in the subgrade. Additionally, an energy-monitoring module composed of strain gauges and an accelerometer is connected to the head of the outer rod to measure the dynamic responses during the dynamic penetration. Moreover, eight strain gauges are installed in the load cells for static penetration to measure the cone tip resistance and the friction resistance during static penetration. To investigate the applicability of the developed CPD, laboratory and field tests are performed. The results of the CPD tests, i.e., profiles of the corrected dynamic cone penetration index (CDI), profiles of the cone tip and friction resistances, and the friction ratio are obtained at high resolution. Moreover, the maximum shear modulus of the subgrade is estimated using the relationships between the static penetration resistances and the maximum shear modulus obtained from the laboratory tests. This study suggests that the CPD test may be a useful method for the characterization of track substructures.

CPT와 DMT를 이용한 고결모래의 변형계수 추정 (Estimation of Deformation Modulus of Cemented Sand using CPT and DMT)

  • 이문주;최성근;홍성진;이우진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.484-491
    • /
    • 2008
  • The purpose of this study is to compare the cementation effect on cone resistance and DMT indices and to evaluate the deformation characteristic of cemented sand using cone resistance and dilatometer modulus. Specimens of various relative densities with three different cementation levels are prepared in a large calibration chamber under different vertical stress levels. Test result shows that the cone resistance and dilatometer modulus underestimate the deformation modulus of cemented sand, since in situ penetration tests such as CPT and DMT damage the cementation bonds during penetration. By regression analysis, the constrained modulus of cemented sand is related with the cone resistance and the dilatometer modulus.

  • PDF

연약지반에 대한 더치콘과 피에조콘 관입시험 비교 연구 (Comparative Study of Dutch Cone and Piezocone Penetration Test on Soft Ground)

  • 원정윤;장병욱;우철웅;윤상묵
    • 한국농공학회지
    • /
    • 제45권2호
    • /
    • pp.96-106
    • /
    • 2003
  • 134 Dutch cone (mechanical cone) and 9 piezocone (electronic cone) penetration tests have been performed in the southwestern part of Korea. In general, Dutch cone results may be different from that of piezocone due to the difference in structure of the cones. 6 Dutch cone and piezocone test data which were obtained at the same point respectively, were analyzed and plotted in soil classification chart proposed by Robertson et. al.(1986, 1990). Cone factors of Dutch cone and piezocone test empirically have been determined using laboratory and field vane test results. Using this cone factors, it was shown that there was good correlation between shear strength estimated using cone resistance and that of laboratory test and field vane tests. It was found that there was a good correlation between cone resistance from Dutch cone and that from piezocone. Relationship formula was also suggested. Dutch cone test provides a useful means for stratigraphic profiling in large project and has some advantage over piezocone in particular situations, such as very soft clay ground and dredged area.

주행형(走行型) Cone-Penetrometer 개발(開發)에 관(關)한 연구(硏究) (Development of Travelling Cone-Penetrometer)

  • 이기명;송재관;장대철;정성원
    • Journal of Biosystems Engineering
    • /
    • 제12권3호
    • /
    • pp.1-6
    • /
    • 1987
  • The objective of this study is to develop a soil hardness tester which can estimate tillage resistance with tae travelling cone-penetrometer. For the study, a series of tests was performed using the cone penetrating in the horizontal direction. Based on the tests above, soil hardness was represented by travelling cone-index vs depth of cone penetration, travelling speed and moisture contents of the soil Resistance characteristics obtained from the experiments were compared with those by a vertical cone-penetrometer and the Yamanaka's soil hardness tester. Following conclusions were made from the study. 1. 8 to 9 peaks per one meter were detected in the resistance curve of cone penetration regardless of the travelling speed of cone-penetrometer when it penetrated the soil in the horizontal direction. This phenomenon seemed to be a similar one noticed in shearing pitch of plowing. 2. Cone index increased as travelling speed increased from 0.08m/sec to 0.5m/sec. 3. Linear relationship was found between the cone indices measured by the travelling coe-penetrometer and Yamanaka's hardness tester. 4. Increasing rate of the cone indices measured by vertical cone-penetrometer decreased as the depth of soil increased while the cone indices by the travelling cone-pentrometer increased linearly.

  • PDF

원위치 관입실험기를 활용한 철도 노반 평가 (Railbed Evaluation by using In-situ Penetration Test)

  • 김주한;박정희;윤형구;고태훈;이종섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.261-267
    • /
    • 2011
  • The test fit has commonly used for the evaluation of the railbed condition, and indirect methods by using the compressional wave are also studied. the direct evaluation method by penetration test has not been studied. For the measurement of in-situ cone tip resistance of the railbed with minimizing the disturbance of the upper railbed. the cone penetrometer with the helical type outer rod(CPH) was developed. The outer rod, which has helical screw, is penetrated through the gravel layer and provides the reaction force for cone penetration testing. the cone tip resistances are measured by the mini cone penetrometer, where diameter is 15mm. For the developing the mini cone, strain gauge installation, circuit configuration, penetration rates and calibration process are considered. For the easy penetration of the screw rod in the field, the reaction force stepping plate and guide column are arranged. The screw rod are penetrated through the gravel layer. And the mini cone was pushed into the subgrade railbed at the penetration rate of 1mm/sec. The penetration test shows that the cone tip resistance increases along the depth. In addition, the subgrade condition is evaluated. This study demonstrates that the CPH may be effectively used for the evaluation of subgrade method any damage of the gravel layer.

  • PDF