• 제목/요약/키워드: Cone Resistance

검색결과 198건 처리시간 0.025초

CPT를 이용한 부산점토의 압축특성에 관한 연구 (Estimation of compressibility for Busan clay by CPT)

  • 홍성진;이문주;심성현;이우진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.320-325
    • /
    • 2009
  • The constrained modulus, representative property to evaluate compressibility of soil, is needed to estimate the settlement of ground structure. A series of lab and field cone penetration tests for clayey soil of Busan new-port and Noksan industrial area were conducted to evaluate the estimation method of constrained modulus. Since CPT generates large deformation of ground, it is difficult to correlate the cone resistance with the constrained modulus. Therefore, appropriate correlation between them is essential to estimate the constrained modulus based on CPT results. The test results show that the ratio of the constrained modulus to the cone resistance is inversely proportional with plasticity index. Based on this result, the estimation method of constrained modulus for Busan clay is suggested.

  • PDF

경량 동적콘관입시험기를 이용한 화강풍화토의 다짐도에 따른 역학특성 (A Mechanical Properties According to the Compaction Degree on Weathered Granite Soil Using Lightweight Dynamic Cone Penetrometer)

  • 김연일;김진영;심재록;최진;강권수;백원진;이강일
    • 한국지반신소재학회논문집
    • /
    • 제13권3호
    • /
    • pp.21-30
    • /
    • 2014
  • 본 연구에서는 남원 사면현장에서 채취된 화강풍화토를 이용하여 경량 동적콘관입시험기의 국내 사면현장에서 적용성을 조사하였다. 그리고 다짐도와 함수비 변화에 따른 경량 동적콘관입시험을 수행하고, 다짐도, 간극비, 포화도와 콘관입 저항치와의 상관성을 분석하였다. 그 결과로 최적함수비의 건조측에서 함수비 증가와 더불어 관입저항치가 급격히 증가하고 습윤측에서 크게 감소하는 경향을 나타내었다. 또한 물리적 특성과의 상관관계에서 다짐도 및 포화도가 클수록 콘 저항치가 선형적으로 증가하는 것을 확인하였다. 이로 인해 역학특성 변화에 따른 함수비, 간극비, 포화도와 콘관입저항치 사이에 높은 상관성을 보여 사면조사시 경량 동적콘관입시험기의 현장적용이 가능할 것으로 판단된다.

고결모래의 콘선단저항과 미소변형전단탄성계수 관계 (Relationship between Cone Tip Resistance and Small-Strain Shear Modulus of Cemented Sand)

  • 이문주;이우진;김재정;최영민
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.331-340
    • /
    • 2009
  • This study evaluates the relationship between cone tip resistance ($q_c$) and small-strain shear modulus ($G_{max}$) of cemented sand. For this purpose, a series of miniature cone penetration and bender element tests are performed in calibration chamber specimens with various gypsum contents. Experimental results show that both $q_c$ and $G_{max}$ of sand increase with increasing cementation level as well as relative density and vertical confining stress. However, the relative density and vertical confining stress has more significant influence on $G_{max}$ and $q_c$ of uncemented sand than those of cemented sand. It is observed that the $G_{max}/q_c$ ratio of cemented sand decreases with increasing relative density. This result means that state variables have more affect on $q_c$ than $G_{max}$ of cemented sand. Test results also show that the effect of vertical stress on $G_{max}-q_c$ relation is reduced by cementation effect.

  • PDF

초소형 마이크로콘 관입시험기의 개발 및 적용 (Development and Application of Ultra Small Micro-Cone Penetrometer)

  • 이종섭;신동현;윤형구;이우진
    • 한국지반공학회논문집
    • /
    • 제24권2호
    • /
    • pp.77-86
    • /
    • 2008
  • 흙의 교란영역과 측정값은 관입시험기의 크기에 영향을 받는다. 관입기의 크기가 작을수록 더 국부적인 값을 얻을 수 있다. 관입시험 시 흙의 교란을 최소화하면서 흙의 특성을 파악하기 위하여 극소형 마이크로콘(외경 5mm)을 설계 및 제작하였다. 선단저항력은 마이크로콘 선단부에 설치된 변형률계를 이용하여 측정하였다. 뿐만 아니라 선단 저항력으로부터 마찰저항력 성분을 효과적으로 제거하기 위하여 이중관 형식의 마찰 슬리브를 채택하였다. 설계 시 변형률계의 설치, 회로구성, 관입시스템, 관입속도, 측정률, 작동 온도, 그리고 calibration 과정이 고려되었다. 점토의 경계면, 점토-모래지반의 경계면을 마이크로콘을 적용함으로써 효과적으로 찾아 낼 수 있었다. 뿐만 아니라, 마이크로 콘과 직경 16mm의 미니어처 콘을 이용하여 측정한 선단저항력이 매우 유사하지만, 마이크로 콘의 해상도가 매우 높은 것으로 나타났다. 본 논문은 마이크로 콘이 매우 높은 해상도 그리고 주변지반의 변형을 최소화하면서 흙의 경계면을 효과적으로 감지할 수 있음을 보여준다.

굴뚝의 우수유입방지 특성 (Characteristics of Rainfall Protection for Stacks)

  • 김종철;김태형
    • 한국산업보건학회지
    • /
    • 제10권1호
    • /
    • pp.18-31
    • /
    • 2000
  • A stack must be designed to 1) reduce or eliminate rainfall or snowfall into a industrial exhaust system, 2) minimize a resistance to flow, 3) maximize the vertical dispersion of the contaminated air and 4) minimize maintenance. The weather cone stacks and the elbow-type stacks are very popular in Korea. But they add some resistance to the exhaust system resulting in reduction of air flow rate, but also deflect the noxious contaminants downward in undiluted form. To solve these problems, ACGIH (American Conference of Governmental Industrial Hygienists) suggested the vertical discharge stack with concentric space between the upper stack with larger diameter and the lower stack with smaller diameter. The preliminary test showed that the vertical discharge stacks did not have the good rainfall protection. The reversed cone were newly devised to satisfy the requirements for the good stack. Subsequently, the amount of rain being penetrated through the stacks was measured while the stacks were simultaneously and naturally exposed to rain in the same area outside. Test results indicate that none of the stacks tested completely exclude rain. The efficiency of rainfall protection and the pressure loss coefficient were compared. The temporary conclusion was reached to the point that the reversed cone stack is the best one. Further research is underway.

  • PDF

원위치 관입실험기를 활용한 철도 노반 평가 (Railbed Evaluation by using In-situ Penetration Test)

  • 김주한;박정희;윤형구;고태훈;이종섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.261-267
    • /
    • 2011
  • The test fit has commonly used for the evaluation of the railbed condition, and indirect methods by using the compressional wave are also studied. the direct evaluation method by penetration test has not been studied. For the measurement of in-situ cone tip resistance of the railbed with minimizing the disturbance of the upper railbed. the cone penetrometer with the helical type outer rod(CPH) was developed. The outer rod, which has helical screw, is penetrated through the gravel layer and provides the reaction force for cone penetration testing. the cone tip resistances are measured by the mini cone penetrometer, where diameter is 15mm. For the developing the mini cone, strain gauge installation, circuit configuration, penetration rates and calibration process are considered. For the easy penetration of the screw rod in the field, the reaction force stepping plate and guide column are arranged. The screw rod are penetrated through the gravel layer. And the mini cone was pushed into the subgrade railbed at the penetration rate of 1mm/sec. The penetration test shows that the cone tip resistance increases along the depth. In addition, the subgrade condition is evaluated. This study demonstrates that the CPH may be effectively used for the evaluation of subgrade method any damage of the gravel layer.

  • PDF

해머 타격과 관입량 측정이 자동화된 소형 동적콘관입시험기의 현장 적용성 연구 (A Study on the Field Application of a Small Dynamic Cone Penetration Tester Using Hammer Automatic Strike and Penetration Measurement)

  • 채휘영;권순달
    • 한국지반환경공학회 논문집
    • /
    • 제24권12호
    • /
    • pp.5-11
    • /
    • 2023
  • 도로나 태양광 발전시설의 인위적으로 조성된 지반이 집중호우와 같은 강우에 의해서 약화되면서 발생되는 산사태, 토석류 등에 의해 경제적 피해가 발생하고 있다. 인위적으로 조성된 지반의 안정성을 파악하기 위해서 지층의 구성상태, 역학적 특성등의 지반정보 확인이 매우 중요하다. 하지만 조사부지가 대부분 급경사로 이루어지거나 진입로가 대부분 없기 때문에 지반정보를 확인하기 위해 일반적으로 사용되고 있는 시추장비와 표준관입시험의 수행이 쉽지 않다. 본 연구에서는 소형화한 오거시추 장비와 자동낙하장치를 적용한 동적콘관입시험(Dinamic Cone Penetrometer, DCP) 장비를 개발하여 산지태양광 부지에서의 적용성을 확인하기 위하여 콘저항값 및 동적콘관입시험값과 표준관입시험값의 상관관계를 분석하였다. 그 결과 콘저항값은 qc = 0.46 N, 동적콘관입시험값(Nd)는 Nd = 1.58 N으로 기존연구자들의 결과와 유사한 값을 확인하여 그 신뢰성을 확보하였다.

휴대용콘의 선단저항값을 이용한 모래의 상대밀도 및 내부마찰각 추정 (Estimation of the Relative Density and Internal Friction Angle for Sand using Cone-tip Resistance of the PCPT)

  • 박재성;손영환;노수각;봉태호
    • 한국농공학회논문집
    • /
    • 제54권4호
    • /
    • pp.137-145
    • /
    • 2012
  • Sand is one of the essential materials used for social infrastructure construction such as embankment, landfill and backfill. It was known that mechanical properties and shear strength of sand are closely related to relative density. Therefore it is very important to determine accurate relative density. In this study, Portable Cone Penetration Tester (PCPT) was used to estimate the relative density and the internal friction angle of sand. PCPT cone-tip resistance ($q_c$) was measured changing the relative density of the two soil samples.Standard sand (JMJ) and Busan sand (BS). Also, a direct shear test was performed to investigate relationship between relative density and internal friction angle. The size and shape of soil particles were confirmed by using Scanning Electron Microscope (SEM). As a result, the log value of $q_c$ was linearly correlated with relative density and internal friction angle. In particular, the internal friction angle of BS sample was greater than that of JMJ, which was due to difference of the shape and mean size of particles. This result shows that it is important to determine the shape and size of particles as well as relative density to define mechanical property of sand. Through this study, it can be more effectively and conveniently to investigate relative density and shear strength of sand by using PCPT in situ.

준설토의 퇴적형상과 수침조건에 따른 토목섬유 튜브 내 준설토의 콘 저항치에 관한 연구 (A Study on the Shape and Cone Resistance of Dredged Fill in Geotextile Tube under Water and Drained Conditions)

  • 김형주;원명수;이장백;김영신
    • 대한토목학회논문집
    • /
    • 제36권1호
    • /
    • pp.85-96
    • /
    • 2016
  • 본 연구에서는 채움모듈 형태에 따른 준설토의 퇴적분포와 튜브 형상 그리고 토목섬유 튜브의 수침조건에 따른 튜브 내 준설토의 콘 관입 저항특성을 규명하고자 일련의 시험을 수행하였다. 채움모듈 형태에 따른 아크릴 토조와 비닐 튜브 준설토의 퇴적분포를 관찰한 결과 I형 채움모듈은 분화구형상을 나타내고 역T형 채움모듈은 수평방향으로 균등하게 준설토가 퇴적되는 것으로 나타났다. 새만금 내부로부터 채취한 준설토의 채움 단계 별 튜브의 변형은 튜브로부터 배수가 종료됨과 거의 동시에 튜브의 변형이 수렴되고, 토목섬유 튜브 내 준설토의 콘 저항치는 배수의 경우가 수침 보다 2~6배정도 크게 나타났다.

준설해사로 다짐된 방조제 제체 성토부의 콘저항치와 전기비저항 관계 (Cone resistance and electrical resistivity with Depth at Dredged Sea Sand Region)

  • 송성호;강미경
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2008년도 공동학술대회
    • /
    • pp.37-40
    • /
    • 2008
  • 준설해사를 이용하여 성토된 방조제 제체 매질에서 채취한 시료에 대하여 전기비저항을 실측하였으며, 소형루프 전자탐사의 1차원 역산 자료를 비교 분석한 결과 높은 상관성이 나타남을 확인하였다. 이러한 소형루프 전자탐사결과를 콘관입시험 결과와 비교하여, 비저항값과 콘저항치와의 상관성을 분석하였다. 분석 결과 준설해사로 성토된 방조제의 경우 1 ohm-m 이하의 비저항값이 나타나는 구간과 콘저항치가 50 $kgf/cm^2$ 이하로 매우 낮은 값을 나타내는 구간이 일치하는 것으로 나타났다. 따라서 향후 준설해사로 성토된 방조제의 경우 정기적인 비저항 모니터링의 결과를 활용한 유지 관리 업무에 활용이 가능한 것으로 나타났다.

  • PDF