• Title/Summary/Keyword: Cone Beam Computed Tomography(CBCT)

Search Result 554, Processing Time 0.029 seconds

Comparison of micro-computerized tomography and cone-beam computerized tomography in the detection of accessory canals in primary molars

  • Acar, Buket;Kamburoglu, Kivanc;Tatar, Ilkan;Arikan, Volkan;Celik, Hakan Hamdi;Yuksel, Selcen;Ozen, Tuncer
    • Imaging Science in Dentistry
    • /
    • v.45 no.4
    • /
    • pp.205-211
    • /
    • 2015
  • Purpose: This study was performed to compare the accuracy of micro-computed tomography (CT) and cone-beam computed tomography (CBCT) in detecting accessory canals in primary molars. Materials and Methods: Forty-one extracted human primary first and second molars were embedded in wax blocks and scanned using micro-CT and CBCT. After the images were taken, the samples were processed using a clearing technique and examined under a stereomicroscope in order to establish the gold standard for this study. The specimens were classified into three groups: maxillary molars, mandibular molars with three canals, and mandibular molars with four canals. Differences between the gold standard and the observations made using the imaging methods were calculated using Spearman's rho correlation coefficient test. Results: The presence of accessory canals in micro-CT images of maxillary and mandibular root canals showed a statistically significant correlation with the stereomicroscopic images used as a gold standard. No statistically significant correlation was found between the CBCT findings and the stereomicroscopic images. Conclusion: Although micro-CT is not suitable for clinical use, it provides more detailed information about minor anatomical structures. However, CBCT is convenient for clinical use but may not be capable of adequately analyzing the internal anatomy of primary teeth.

Endodontic management of a maxillary first molar with three roots and seven root canals with the aid of cone-beam computed tomography

  • Nayak, Gurudutt;Singh, Kamal Krishan;Shekhar, Rhitu
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.3
    • /
    • pp.241-248
    • /
    • 2015
  • Variation in root canal morphology, especially in maxillary first molar presents a constant challenge for a clinician in their detection and management. This case report describes the successful root canal treatment of a three rooted right maxillary first molar presenting with three canals each in the mesiobuccal and distobuccal roots and one canal in the palatal root. The clinical detection of this morphologic aberration was made using a dental operating microscope, and the canal configuration was established after correlating and computing the clinical, radiographic and cone-beam computed tomography (CBCT) scan findings. CBCT images confirmed the configuration of the canals in the mesiobuccal and distobuccal roots to be Al-Qudah and Awawdeh type (3-2) and type (3-2-1), respectively, whereas the palatal root had a Vertucci type I canal pattern. This report reaffirms the importance of careful examination of the floor of the pulp chamber with a dental operating microscope and the use of multiangled preoperative radiographs along with advanced diagnostic aids such as CBCT in identification and successful management of aberrant canal morphologies.

Anomalies of the clivus of interest in dental practice: A systematic review

  • McCartney, Troy E.;Mupparapu, Mel
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.351-361
    • /
    • 2021
  • Purpose: The clivus is a region in the anterior section of the occipital bone that is commonly imaged on large-volume cone-beam computed tomography (CBCT). There have been several reports of incidental clivus variations and certain pathological entities that have been attributed to the variations. This study aimed to evaluate the effects of these variations within the scope of dentistry. Materials and Methods: Medical databases (PubMed, Scopus, and Web of Science) were searched using a controlled vocabulary (clival anomalies, cone-beam CT, canalis basilaris medianus, fossa navicularis magna, clival variation). The search was limited to English language, humans, and studies published in the last 25 years. The articles were exported into RefWorks® and duplicates were removed. The remaining articles were screened and reviewed for supporting information on variations of the clivus on CBCT imaging. Results: Canalis basilaris medianus and fossa navicularis magna were the most common anomalies noted. Many of these variations were asymptomatic, with most patients unaware of the anomaly. In certain cases, associated pathologies ranged from developmental (Tornwaldt cyst), to acquired (recurrent meningitis). While no distinct pathognomonic aspects were noted, there were unique patterns of radiographic diagnosis and treatment modalities. Most patients had a normal course of follow-up. Conclusion: Interpretation of CBCT volumes is a skill every dentist must possess. When reviewing large-volume CBCT scans, the clinician should be able to distinguish pathology from normal anatomic variations within the skull base. The majority of clivus variations are asymptomatic and will remain undetected unless incidentally noted on radiographic examinations.

How to Choose and Use the CBCT (임상가를 위한 특집 1 - CBCT의 선택과 처방)

  • An, Chang-Hyeon
    • The Journal of the Korean dental association
    • /
    • v.52 no.3
    • /
    • pp.132-138
    • /
    • 2014
  • The emergence of Cone Beam Computed Tomography(CBCT) in the late 1990s represented an innovative advancement in the field of dental and maxillofacial radiology because it greatly reduced the radiation exposure to patients and offered 3D images easily. The 3D information generated by this technique brings the potential of improved diagnosis and treatment planning for a wide range of clinical applications in dentistry. The use of CBCT includes diagnosis and surgical assessment of the orofacial hard tissue lesions, dental implant treatment planning and postoperative evaluation, TMJ assessment, diagnosis of craniofacial fracture, orthodontics, endodontics, and so on. All CBCT examinations should be justified on an individualized needs. The clinical benefits to the patient for each CBCT scan must outweigh the potential risks associated with exposure to ionizing radiation. CBCT scans should be taken with initially obtained medical and dental histories of patients and a close clinical examination. CBCT should be considered as an imaging alternative of other conventional radiography in cases where the anatomical structures of interest may not be seen. The smallest possible field of view(FOV) and the lowest setting of tube current and scan time should be chosen, and the entire images scanned should be interpreted by a qualified expert.

Evaluation of imaging reformation with cone beam computed tomography for the assessment of bone density and shape in mandible (Cone beam형 전산화단층영상에서 골의 형태와 밀도의 평가)

  • Hong, Sang-Woo;Kim, Gyu-Tae;Choi, Yon-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.38 no.1
    • /
    • pp.49-56
    • /
    • 2008
  • Purpose: Diagnostic estimation of destruction and formation of bone has the typical limit according to capacity of x-ray generator and image detector. So the aim of this study was to find out how much it can reproduce the shape and the density of bone in the case of using recently developed dental type of cone beam computed tomography, and which image is applied by new detector and mathematic calculation. Materials and Methods: Cone beam computed tomography (PSR 9000N, Asahi Roentgen Ind. Co., Ltd., Japan) and soft x-ray radiography were executed on dry mandible that was already decalcified during 5 hours, 10 hours, 15 hours, 20 hours, and 25 hours. Estimating and comparing of those came to the following results. Results: The change of inferior border of mandible and anterior border of ramus in the region of cortical bone was observed between first 5 and 10 hours of decalcification. The reproduction of shape and density in the region of cortical bone and cancellous bone can be hardly observed at cone beam computed tomography compared with soft x-ray radiography. The difference of decrease of bone density according to hours of decalcification increase wasn't reproduced at cone beam computed tomography compared with soft x-ray radiography. Conclusion: CBCT images revealed higher spatial resolution. However, contrast resolution in region of low contrast sensitivity is the inferiority of images' property.

  • PDF

Comparison of Volumes between Four-Dimensional Computed Tomography and Cone-Beam Computed Tomography Images using Dynamic Phantom (호흡동조전산화단층촬영과 콘빔전산화단층촬영의 팬텀 영상 체적비교)

  • Kim, Seong-Eun;Won, Hui-Su;Hong, Joo-Wan;Chang, Nam-Jun;Jung, Woo-Hyun;Choi, Byeong-Don
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.123-130
    • /
    • 2016
  • Purpose : The aim of this study was to compare the differences between the volumes acquired with four-dimensional computed tomography (4DCT)images with a reconstruction image-filtering algorithm and cone-beam computed tomography (CBCT) images with dynamic phantom. Materials and Methods : The 4DCT images were obtained from the computerized imaging reference systems (CIRS) phantom using a computed tomography (CT) simulator. We analyzed the volumes for maximum intensity projection (MIP), minimum intensity projection (MinIP) and average intensity projection (AVG) of the images obtained with the 4DCT scanner against those acquired from CBCT images with CT ranger tools. Results : Difference in volume for node of 1, 2 and 3 cm between CBCT and 4DCT was 0.54~2.33, 5.16~8.06, 9.03~20.11 ml in MIP, respectively, 0.00~1.48, 0.00~8.47, 1.42~24.85 ml in MinIP, respectively and 0.00~1.17, 0.00~2.19, 0.04~3.35 ml in AVG, respectively. Conclusion : After a comparative analysis of the volumes for each nodal size, it was apparent that the CBCT images were similar to the AVG images acquired using 4DCT.

  • PDF

Characteristic features of fungus ball in the maxillary sinus and the location of intralesional calcifications on computed tomographic images: A report of 2 cases

  • Lee, Jae-Hoon;Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.50 no.4
    • /
    • pp.377-384
    • /
    • 2020
  • This report presents 2 cases of sinus fungus ball and describes the characteristic radiographic features of fungus ball in the maxillary sinus. Two female patients, aged 62 and 40 years, sought consultations at a dental hospital for the treatment of dental implants and tooth pain, respectively. Panoramic radiography and small field-of-view(FOV) cone-beam computed tomography (CBCT) did not provide detailed information for the radiographic diagnosis of fungus ball due to the limited images of the maxillary sinus. Additional paranasal sinus computed tomographic images showed the characteristic features of fungus ball, such as heterogeneous opacification and intralesional calcification of the maxillary sinus. The calcified materials of the fungus balls were located in the middle and superior regions of the maxillary sinus. It is necessary to use large-FOV CBCT for the detection of calcified materials in the upper maxillary sinus to confirm the diagnosis of fungus ball.

Arrested pneumatization of the sphenoid sinus mimicking intraosseous lesions of the skull base

  • Jalali, Elnaz;Tadinada, Aditya
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.67-72
    • /
    • 2015
  • Arrested pneumatization of the sphenoid sinus is a developmental variant that is not always well recognized and is often confused with other pathologies associated with the skull base. This report describes the case of a patient referred for cone-beam computed tomography (CBCT) imaging for dental implant therapy. CBCT demonstrated a well-defined incidental lesion in the left sphenoid sinus with soft tissue-like density and sclerotic borders with internal curvilinear opacifications. The differential diagnoses included intraosseous lipoma, arrested pneumatization of the sphenoid sinus, chondrosarcoma, chondroid chordoma, and ossifying fibroma. The radiographic diagnosis of arrested pneumatization was based on the location of the lesion, its well-defined nature, the presence of internal opacifications, and lack of expansion. Gray-scale CBCT imaging of the area demonstrated values similar to fatty tissue. This case highlighted the fact that benign developmental variants associated with the skull base share similar radiographic features with more serious pathological entities.

Atypical periosteal reaction and unusual bone involvement of ameloblastoma: A case report with 8-year follow-up

  • Charoenlarp, Pornkawee;Silkosessak-Chaiudom, Onanong;Vipismakul, Vichittra
    • Imaging Science in Dentistry
    • /
    • v.51 no.2
    • /
    • pp.195-201
    • /
    • 2021
  • Unusual radiographic findings of intraosseous ameloblastoma have been reported and discussed. In the case discussed herein, cone-beam computed tomography (CBCT) clearly showed many radiographic features that were ambiguous on conventional radiographs, including an ill-defined periphery, extensive superficial buccal extension with minimal lingual extension, obvious bucco-crestal expansion, and multiple triangular (Codman's triangle-like) areas of periosteal reaction. Based on the above-mentioned findings, the differential diagnosis was a long-term infected benign or low-grade malignant lesion. An incisional biopsy was performed, and the histopathologic diagnosis was acanthomatous ameloblastoma. Recurrence of the lesion was clearly detected on CBCT images at 4 and 8 years after surgery. These unusual radiographic findings have never been reported to be associated with ameloblastoma, and thus may contribute to novel concepts in radiographic interpretation in the future. This report also underscores the important role played by CBCT as a comprehensive diagnostic tool and for definite confirmation of recurrence.

Maxillary sinus septa: comparison between panoramic radiography and CBCT (상악동 중격: 파노라마 방사선사진과 CBCT의 비교)

  • Nah, Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • v.40 no.2
    • /
    • pp.59-62
    • /
    • 2010
  • Purpose : To investigate and compare the prevalence, size, and location of maxillary sinus septa on panoramic and cone beam computed tomography (CBCT) images. Materials and Methods : Two hundred patients who had taken both panoramic and CBCT images were included. The location of maxillary sinus septa on the panoramic radiographs were recorded and confirmed on the CBCT images. Also the size of septa was measured on the reformatted CBCT images. Results : The prevalence of the patients who had maxillary sinus septa was 51.0% and they showed 179 septa totally. Among them 51.0% of the patients had one septum, 32.4% two septa, 13.7% three, and 2.9% four. The measured heights of the septa were $4.37{\pm}2.87\;mm$, $3.51{\pm}2.47\;mm$, and $3.04{\pm}2.37\;mm$ in the medial, middle, and lateral areas, respectively. It was revealed that 1.0% was located at canine region, 18.0% at first premolar, 25.0% at second premolar, 22.7% at first molar, 19.8% at second molar, and 14.0% at third molar region. Among 213 septa depicted by the panoramic radiographs, only 69.0% were confirmed at the CBCT images. Conclusion : Since various heights and courses of the septa can develop in all parts of the maxillary sinus, adequate assessment of the inner aspect of the maxillary sinus is essential to avoid complications during sinus augmentation procedures. CBCT scanning is the preferred radiographic method for detecting the presence of sinus septa.