• Title/Summary/Keyword: Cone Beam Computed Tomography(CBCT)

Search Result 552, Processing Time 0.022 seconds

Comparison of conventional lateral cephalograms with corresponding CBCT radiographs

  • Park, Chang-Seo;Park, Jae-Kyu;Kim, Huijun;Han, Sang-Sun;Jeong, Ho-Gul;Park, Hyok
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.201-205
    • /
    • 2012
  • Purpose: This study was performed to assess the compatibility of cone beam computed tomography (CBCT) synthesized cephalograms with conventional cephalograms, and to find a method for obtaining normative values for three-dimensional (3D) assessments. Materials and Methods: The sample group consisted of 10 adults with normal occlusion and well-balanced faces. They were imaged using conventional and CBCT cephalograms. The CBCT cephalograms were synthesized from the CBCT data using OnDemand 3D software. Twenty-one angular and 12 linear measurements from each imaging modality were compared and analyzed using paired-t test. Results: The linear measurements between the two imaging modalities were not statistically different (p>0.05) except for the U1 to facial plane distance. The angular measurements between the two imaging modalities were not statistically different (p>0.05) with the exception of the gonial angle, ANB difference, and facial convexity. Conclusion: Two-dimensional cephalometric norms could be readily used for 3D quantitative assessment, if corrected for lateral cephalogram distortion.

Bone change of mandibular condyle using cone beam computed tomography (Cone beam형 전산화단층촬영법을 이용한 하악과두의 골변화에 관한 연구)

  • Lee, Ji-Un;Kim, Hyung-Seop;Song, Ju-Seop;Kim, Kyoung-A;Koh, Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.139-147
    • /
    • 2007
  • Purpose: To assess bone changes of mandibular condyle using cone beam computed tomography (CBCT) in temporomandibular disorder (TMD) patients. Materials and Methods: 314 temporomandibular joints (TMJs) images of 163 TMD patients were examined at the Department of Oral and Maxillofacial Radiology, Chonbuk National University. The images were obtained by PSR9000N (Asahi Roentgen Co., Japan) and reconstructed by using Asahivision software (Asahi Roentgen Co., Japan). The CBCT images were examined three times with four weeks interval by three radiologists. Bone changes of mandibular condyle such as flattening, sclerosis, erosion and osteophyte formation were observed in sagittal, axial, coronal and 3 dimensional images of the mandibular condyle. The statistical analysis was performed using SPSS 12.0. Intra- and interobserver agreement were performed by 3 radiologists without the knowledge of clinical information. Results: Osteophyte (2.9%) was found more frequently on anterior surface of the mandibular condyle. Erosion (31.8%) was found more frequently on anterior and medial surfaces of the mandibular condyle. The intraobserver agreement was good to excellent (k=0.78-0.84), but interobserver agreement was fair (k=0.45). Conclusion: CBCT can provide high qualified images of bone changes of the TMJ with axial, coronal and 3 dimensional images.

  • PDF

Nutrient canals on mandibular anterior region in cone beam computed tomography (Cone beam형 전산화 단층영상을 이용한 하악전치부 영양관의 연구)

  • Kang Jung-Ho;Kim Gyu-Tae;Choi Yong-Suk;Hwang Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.36 no.3
    • /
    • pp.137-143
    • /
    • 2006
  • Purpose : To evaluate location, distribution, diameter, and length of the nutrient canals on mandibular anterior region using a cone beam computed tomography (CBCT). Materials and Methods : Mandibular CBCT was performed on 33 adults (18 males and 15 females) with no history of systemic disease, and any other dental surgery history Location, distribution, diameter, and length of the nutrient canals on mandibular anterior region were radiographically evaluated. A statistical comparison was done by SPSS. Results : In the location and distribution of nutrient canals, they were found in 6.8% at labial portion above root apex, in 93.28% at lingual portion above root apex in 46.2% at labial portion below root apex, and in 53.6% at lingual portion below root apex. Nutrient canals at lingual portion above root apex were most frequently observed between central and lateral incisors, and those at labial and lingual portion below root apex were most frequently observed between central incisors. The mean diameters of nutrient canals were 0.54 mm at labial portion above root apex, 0.61 mm at lingual portion above root apex, 0.66 mm at labial portion below root apex, and 0.76 mm at lingual portion below root apex. The mean lengths of nutrient canals were 2.63 mm at labial portion above root apex, 3.74 mm at lingual portion above root apex, 4.51 mm at labial portion below root apex, and 6.77 mm at lingual portion below root apex. Conclusion : CBCT is useful device to evaluate the anatomical structure of nutrient canals on mandibular anterior region.

  • PDF

ASSESSMENT OF BONE DENSITY ON MAXILLA AFTER IMPLANTATION WITH CONE BEAM COMPUTED TOMOGRAPHY (Cone Beam Computed Tomography를 이용한 상악 임플란트 식립 전후의 골밀도 변화에 관한 연구)

  • Choi, Jeong-Hun;Lee, Ju-Min;Kim, Yong-Deok;Shin, Sang-Hun;Chung, In-Kyo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.3
    • /
    • pp.229-235
    • /
    • 2010
  • Purpose: This study examined the significance of increased bone density according to time after implantation on maxilla using demographic data with CBCT and compared the bone density between before vs. after implantation using the Hounsfield index. Materials and Methods: Twenty-five implant site on maxilla were selected. Cone-beam computerized tomography (CBCT) scans were used for the analysis. The implant sites were evaluated digitally using the Hounsfield scale with EzImplant TM and the results were compared over time. Statistical data over time was carried out to determine the correlation between the recorded Hounsfield unit (HU) over time and gender difference using repeated ANOVA. Results: The bone density of implantation site over time showed an increase in the HU mean values. Immediately after implantation, bone density was significantly increased than bone density before implantation. Until 6 month follow-up, bone density showed stable increasement. There is no significant difference on gender. Conclusions: Using CBCT, bone density increased over time after implantation on maxilla. Bone density measurements using CBCT might provide an objective assessment of the bone quality as well as the correlation between bone density and stability of implant.

Cone-Beam Computed Tomographic Assessment of Temporomandibular Joint Morphology in Patients with Temporomandibular Joint Disc Displacement and in Healthy Subjects: A Pilot Study

  • Choi, Hang-Moon;Park, Moon-Soo
    • Journal of Oral Medicine and Pain
    • /
    • v.41 no.2
    • /
    • pp.41-47
    • /
    • 2016
  • Purpose: The purpose of this study was to analyze the size and morphology of mandibular condyle and mandibular fossa between temporomandibular joint (TMJ) disc displacement (DD) patients and healthy subjects using cone-beam computed tomography (CBCT). Methods: Twenty healthy subjects and twenty TMJ DD patients participated in this study respectively. We made five measurements in mandibular condyle (medio-lateral dimension, antero-posterior dimension, condyle height, intercondylar distance and intercondylar angle) and two measurements in mandibular fossa (mandibular fossa depth and articular eminence angle) using CBCT image. Results: There was no difference between two groups in medio-lateral dimension. In case of antero-posterior dimension, average of healthy controls was larger than that of TMJ DD patients, but that was not significant statistically. There were no significant differences between two groups in condyle height. Comparing intercondylar distance and intercondylar angle between two groups, there was no significant difference between two groups. In comparison of mandibular fossa depth and articular eminence angle, there was no significant difference between two groups. Conclusions: We couldn't find any definite relationship between TMJ morphology and TMJ DD.

Incidental occurrence of an unusually large mastoid foramen on cone-beam computed tomography and review of the literature

  • Syed, Ali Z.;Sin, Cleo;Rios, Raquel;Mupparapu, Mel
    • Imaging Science in Dentistry
    • /
    • v.46 no.1
    • /
    • pp.39-45
    • /
    • 2016
  • The incidental finding of an enlarged mastoid foramen on the right posterior mastoid region of temporal bone is reported, together with a discussion of its clinical significance. A 67-year-old female underwent the pre-implant assessment of a maxillary left edentulous region. A cone-beam computed tomographic (CBCT) image was acquired and referred for consultation. Axial CBCT slices revealed a unilateral, well-defined, noncorticated, low-attenuation, transosseous defect posterior to the mastoid air cells in the right temporal bone. The borders of the osseous defect were smooth and continuous. No other radiographic signs suggestive of erosion or sclerosis were noted in the vicinity. The density within the defect was homogenous and consistent with a foramen and/or soft tissue. The patient's history and physical examination revealed no significant medical issues, and she was referred to a neuroradiologist for a second opinion. The diagnosis of an enlarged mastoid foramen was made and the patient was reassured.

Accuracy of maxillofacial prototypes fabricated by different 3-dimensional printing technologies using multi-slice and cone-beam computed tomography

  • Yousefi, Faezeh;Shokri, Abbas;Farhadian, Maryam;Vafaei, Fariborz;Forutan, Fereshte
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.41-47
    • /
    • 2021
  • Purpose: This study aimed to compare the accuracy of 3-dimensional(3D) printed models derived from multidetector computed tomography (MDCT) and cone-beam computed tomography (CBCT) systems with different fields of view (FOVs). Materials and Methods: Five human dry mandibles were used to assess the accuracy of reconstructions of anatomical landmarks, bone defects, and intra-socket dimensions by 3D printers. The measurements were made on dry mandibles using a digital caliper (gold standard). The mandibles then underwent MDCT imaging. In addition, CBCT images were obtained using Cranex 3D and NewTom 3G scanners with 2 different FOVs. The images were transferred to two 3D printers, and the digital light processing (DLP) and fused deposition modeling (FDM) techniques were used to fabricate the 3D models, respectively. The same measurements were also made on the fabricated prototypes. The values measured on the 3D models were compared with the actual values, and the differences were analyzed using the paired t-test. Results: The landmarks measured on prototypes fabricated using the FDM and DLP techniques based on all 4 imaging systems showed differences from the gold standard. No significant differences were noted between the FDM and DLP techniques. Conclusion: The 3D printers were reliable systems for maxillofacial reconstruction. In this study, scanners with smaller voxels had the highest precision, and the DLP printer showed higher accuracy in reconstructing the maxillofacial landmarks. It seemed that 3D reconstructions of the anterior region were overestimated, while the reconstructions of intra-socket dimensions and implant holes were slightly underestimated.

Correlation analysis between radiation exposure and the image quality of cone-beam computed tomography in the dental clinical environment

  • Song, Chang-Ho;Yeom, Han-Gyeol;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.283-288
    • /
    • 2022
  • Purpose: This study was conducted to measure the radiation exposure and image quality of various cone-beam computed tomography (CBCT) machines under common clinical conditions and to analyze the correlation between them. Materials and Methods: Seven CBCT machines used frequently in clinical practice were selected. Because each machine has various sizes of fields of view (FOVs), 1 large FOV and 1 small FOV were selected for each machine. Radiation exposure was measured using a dose-area product (DAP) meter. The quality of the CBCT images was analyzed using 8 image quality parameters obtained using a dental volume tomography phantom. For statistical analysis, regression analysis using a generalized linear model was used. Results: Polymethyl-methacrylate (PMMA) noise and modulation transfer function (MTF) 10% showed statistically significant correlations with DAP values, presenting positive and negative correlations, respectively (P<0.05). Image quality parameters other than PMMA noise and MTF 10% did not demonstrate statistically significant correlations with DAP values. Conclusion: As radiation exposure and image quality are not proportionally related in clinically used equipment, it is necessary to evaluate and monitor radiation exposure and image quality separately.

Cone-beam computed tomographic reconstructions in the evaluation of maxillary impacted canines

  • David MacDonald;Sharifa Alebrahim;Edwin Yen;Jolanta Aleksejuniene
    • Imaging Science in Dentistry
    • /
    • v.53 no.2
    • /
    • pp.145-151
    • /
    • 2023
  • Purpose: Prior to cone-beam computed tomography (CBCT), orthodontic competence included radiological interpretation. Nevertheless, maxillary impacted canines (MICs), because of their position and adjacent complex anatomy, have been challenging to interpret, particularly with regard to root resorption. Although CBCT cross-sectional reconstructions of MICs yielded clearer insights into its diagnosis and treatment planning, the value of simultaneously using 2 different cross-sectional or multiplanar reconstructions of the CBCT datasets - orthogonal and curved/panoramic multiplanar reconstructions - has hitherto not been considered. Materials and Methods: Both orthogonal and curved/panoramic multiplanar reconstruction series of 5 screenshots were each reconstructed from the 5 cm×5 cm CBCT datasets of 15 separate MICs. Fifteen credentialled and experienced orthodontist volunteers reviewed 2 separate PowerPoints of 15 randomized series each, 1 week apart. Their review considered 6 factors that could affect treatment: the position and level of the MIC, the presence or absence of root resorption, ankylosis, cysts, and dilaceration. Results: All 15 orthodontists were statistically similar regarding overall years of experience and of CBCT use. Although either reconstruction alone allowed the orthodontists to determine whether ankylosis and, to a lesser extent, most of the other features were present or absent in the MIC, reviewing both reconstructions together was necessary to determine whether root resorption was present or absent in the adjacent tooth. Conclusion: Reviewing both orthogonal and curved/panoramic multiplanar reconstructions was necessary to evaluate the presence or absence of root resorption in the teeth adjacent to MICs and that of many other features.

Radiographic evaluation of dentigerous cyst with cone beam CT (콘빔형전산화단층장치를 이용한 함치성낭의 방사선학적 연구)

  • Park, Yong-Chan;Lee, Wan;Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.40 no.3
    • /
    • pp.115-121
    • /
    • 2010
  • Purpose : The purpose of this study was to accurately analyze the radiographic characteristics of dentigerous cyst (DC) with multiplanar images of cone beam computed tomography (CBCT). Materials and Methods : Thirty eight radiographically and histopathologically proven cases of DCs were analyzed with panoramic radiograph and CBCT, retrospectively. The radiographic CT pattern, symmetry of radiolucency around the unerupted tooth crown, ratio of long length to short length, degree of cortical bone alternation, effects on adjacent tooth, and cyst size were analyzed. Relative frequencies of these radiographic features were evaluated. In order to compare the CBCT features of DC with those of odontogenic keratocyst (OKC), 9 cases of OKCs were analyzed with the same method radiographically. Results : DCs consisted of thirty unilocular cases (79.0%), seven lobulated cases (18.4%) and one multilocular case (2.6%). Eight were asymmetric (21.0%) and thirty were symmetric (79.0%). Maxillary DC showed rounder shape than mandibular DC (L/S ratio; maxilla 1.32, mandible 1.67). Alternations of lingual cortical bone (14 cases, 48.2%) were more frequent than those of buccal side (7 cases, 24.1%). CBCT images of DC showed definite root resorption and bucco-lingual tooth displacement. These findings were hardly observed on panoramic radiographs of DCs. Comparison of CBCT features of DC with those of OKC showed several different features. Conclusions : CBCT images of DC showed various characteristic radiographic features. Therefore, CBCT can be helpful for the diagnosis of DC radiographically.