• Title/Summary/Keyword: Cone Angle

Search Result 375, Processing Time 0.023 seconds

The evaluation for the usability ofthe Varian Standard Couch modelingusing Treatment Planning System (치료계획 시스템을 이용한 Varian Standard Couch 모델링의 유용성 평가)

  • Yang, yong mo;Song, yong min;Kim, jin man;Choi, ji min;Choi, byeung gi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.77-86
    • /
    • 2016
  • Purpose : When a radiation treatment, there is an attenuation by Carbon Fiber Couch. In this study, we tried to evaluate the usability of the Varian Standard Couch(VSC) by modeling with Treatment Planning System (TPS) Materials and Methods : VSC was scanned by CBCT(Cone Beam Computed Tomography) of the Linac(Clinac IX, VARIAN, USA), following the three conditions of VSC, Side Rail OutGrid(SROG), Side Rail InGrid(SRIG), Side Rail In OutSpine Down Bar(SRIOS). After scan, the data was transferred to TPS and modeled by contouring Side Rail, Side Bar Upper, Side Bar Lower, Spine Down Bar automatically. We scanned the Cheese Phantom(Middelton, USA) using Computed Tomography(Light Speed RT 16, GE, USA) and transfer the data to TPS, and apply VSC modeled previously with TPS to it. Dose was measured at the isocenter of Ion Chamber(A1SL, Standard imaging, USA) in Cheese Phantom using 4 and 10 MV radiation for every $5^{\circ}$ gantry angle in a different filed size($3{\times}3cm^2$, $10{\times}10cm^2$) without any change of MU(=100), and then we compared the calculated dose and measured dose. Also we included dose at the $127^{\circ}$ in SRIG to compare the attenuation by Side Bar Upper. Results : The density of VSC by CBCT in TPS was $0.9g/cm^3$, and in the case of Spine Down Bar, it was $0.7g/cm^3$. The radiation was attenuated by 17.49%, 16.49%, 8.54%, and 7.59% at the Side Rail, Side Bar Upper, Side Bar Lower, and Spine Down Bar. For the accuracy of modeling, calculated dose and measured dose were compared. The average error was 1.13% and the maximum error was 1.98% at the $170^{\circ}beam$ crossing the Spine Down Bar. Conclusion : To evaluate the usability for the VSC modeled by TPS, the maximum error was 1.98% as a result of compassion between calculated dose and measured dose. We found out that VSC modeling helped expect the dose, so we think that it will be helpful for the more accurate treatment.

  • PDF

Development of Quality Assurance Program for the On-board Imager Isocenter Accuracy with Gantry Rotation (갠트리 회전에 의한 온-보드 영상장치 회전중심점의 정도관리 프로그램 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.212-223
    • /
    • 2006
  • Positional accuracy of the on-board imager (OBI) isocenter with gantry rotation was presented in this paper. Three different type of automatic evaluation methods of discrepancies between therapeutic and OBI isocenter using digital image processing techniques as well as a procedure stated in the customer acceptance procedure (CAP) were applied to check OBI isocenter migration trends. Two kinds of kV x-ray image set obtained at OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ},\;270^{\circ}$ and every $10^{\circ}$ and raw projection data for cone-beam CT reconstruction were used for each evaluation method. Efficiencies of the methods were also estimated. If a user needs to obtain an isocenter variation map with full gantry rotation, a method taking OBI image for every $10^{\circ}$ and fitting with 5th order polynomial was appropriate. However for a mere quality assurance (QA) purpose of OBI isocenter accuracy, it was adequate to use only four OBI Images taken at the OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ}\;and\;270^{\circ}$. Maximal discrepancy was 0.44 mm which was observed between the OBI source angle of $90^{\circ}\;and\;180^{\circ}$ OBI isocenter accuracy was maintained below 0.5 mm for a year. Proposed QA program may be helpful to Implement a reasonable routine QA of the OBI isocenter accuracy without great efforts.

  • PDF

A Study on the Basic Pattern Drafting Method Development of Men's J$\breve{o}$-go-ri -Collar Construction (2)- (남자저고리 원형제도법 개발을 위한 연구(2) -깃구성을 중심으로-)

  • 정옥임
    • Journal of the Korean Home Economics Association
    • /
    • v.37 no.7
    • /
    • pp.17-27
    • /
    • 1999
  • According to the design method for constructing the Korean Men's Jo-go-ri(the traditional Korean jacket)collar, there are differences in form after its completion. In the construction design of the midsection of the gusset as in that of the basic pattern Jo-go-ri, not only was the positioning of the two sides of the collar not smooth, but also, when the collar strip(Dongjung) was attached, there would be an imbalance on one side or the other so that it was difficult to achieve symmetry. Therefore in this project, by applying the pattern design of the gusset midsection to that of the collar midsection, not only did attaching the collar(Kit) and the collar strip create a visual effect by equalizing the lengths of the two sides, but the construction was also easy. This method of construction introduces the three-dimensional aspect of the human form in its conic, spherical and cylindrical aspects, so that, through schematizing the scientific character of Korea's clothing, its appropriateness is verified. As a matter of fact, since there is no standardization of pattern whether for educational use or for mass-produced clothing, so that even the patterns used in computer-assisted design are executed according to the designer's personal skill, the reality is that after completion of construction the quality has not been uniform. For this schematization, inverse calculation of measurements pertaining to the calculation formula and of teaching materials has been referenced. In particular, the partial regulation of the calculation formula pertaining to the basic pattern construction, the method of making the collar midsection, and the construction method of the extreme and mean ratio adjustment, can be adjusted for all measurements, thereby providing the establishment of a design criterion and the possibility of the standardization of construction methods. The production method for the basic pattern design is as follows: 1) The conic angle for the Jo-go-ri's girth, length end neck width is fixed at 70(72) degree. 2) The radius of the cone is sleeve length. 3) The bust girth calculation formula is B/4 + 2.5 cm. 4) The armhole formula is B/4 + 2.5cm. 5) The neck width formula is B/10. 6) The ratio of the collar junction{width of collar(Kit) + width of collar strip(Dongjung) to the gusset length is 5:8. 7) The length of the side seam is a length intersecting the armhole line and the conic radius of sleeve length, that is an arc that exceeds the length of the Jo-go-ri's midsection.

  • PDF

Experimental Analysis of a Supersonic Plasma Wind Tunnel Using a Segmented Arc Heater with the Power Level of 0.4 MW (0.4 MW 급 분절형 아크 히터를 이용한 초음속 플라즈마 풍동 특성 실험)

  • Kim, Min-Ho;Lee, Mi-Yeon;Kim, Jeong-Soo;Choi, Chea-Hong;Seo, Jun-Ho;Moon, Se-Yeon;Hong, Bong-Guen
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.9
    • /
    • pp.700-707
    • /
    • 2013
  • Experimental analyses on a supersonic plasma wind tunnel of CBNU (Chonbuk National University) were carried out. In these experiments, a segmented arc heater was employed as a plasma source and operated at the gas flow rates of 16.3 g/s and the total currents of 300 A. The input power reached ~350 kW with the torch efficiency of 51.4 %, which is defined as the ratio of total exit enthalpy to the input power. The pressure of plasma gas in the arc heater was measured up to 4 bar while it was down to ~45 mbar in a vacuum chamber through a Laval nozzle. During this conversion process, the generated supersonic plasma was expected to have a total enthalpy of ~11 MJ/kg from the measured input power and torch efficiency. In addition to the measurement of total enthalpy, a cone type probe was inserted into the supersonic plasma flow in order to estimate the angle between shock layer and surface of the probe. From these measurements, the temperature and the Mach number of the supersonic plasma were predicted as ~2,950 K and ~3.7, respectively.

A numerical study on pull-out behaviour of cavern-type rock anchorages (수치해석에 의한 암반상의 지중정착식 앵커리지 인발 거동 연구)

  • Hong, Eun-Soo;Cho, Gye-Chun;Baak, Seng Hyoung;Park, Jae-Hyun;Chung, Moonkyung;Lee, Seong-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.6
    • /
    • pp.521-531
    • /
    • 2014
  • This paper is a study for behaviour of cavern type anchorage tunnels for suspension bridges with cable tension. Anchorage behaviour, design method for anchorage, and failure surface angle, ${\delta}$ are analyzed by comparing numerical analysis results and ultimate pullout capacities($P_u$) using bilinear corelation equation. Results show that design depths for cavern type anchorage tunnels are easily checked with linear relationships for $P/{\gamma}/H$ vs. displacement and $P_u/{\gamma}/H$ vs. H/b. The analysis results of maximum shear strain distribution and plastic status show that failure shapes are closer to circular arc model than soil cone model which frequently used. To an easy calculation of the ultimate pullout capacity, we propose a simple bilinear failure model in this study. The calculated ultimate pullout capacities from the proposed bilinear corelation equation using two failure angles results are similar to the ultimate pullout capacities from numerical analysis.

Development of a Closed Roof Model for Liquid Manure Storage Tanks to Prevent Corrosion and Atmospheric Diffusion of Oder Gases (부식과 악취가스 대기확산 방지를 위한 액비저장조 밀폐형 지붕모델 개발)

  • Yun, N.K.;Lee, S.H.;Kim, K.W.;Yum, S.H.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.1
    • /
    • pp.61-68
    • /
    • 2008
  • The roof structural model of liquid manure storage tank was designed to improve a structural safety and an ability of resistance to corrosion by the bad environmental condition with high humidity and high gas concentration. Due to corrosion of a general steel, the 5 years used materials were reduced to one-third of a new material in the result of a bending strength test. Some structural materials were tested to evaluate a strength and an anti-corrosion, and stainless steel pipe (STS439), steel angle with zinc hot dipping, rectangular steel pipe covered with FRP (Fiberglass Reinforced Plastics) resin were selected finally. A stainless steel is more expansive about $3{\sim}5$ times than general structural steel. But its durability under heavy corrosive environment is expected twice as long as general steel. The roof models were designed as closed cone type for each of the three structural materials. In the result of a FEM (Finite Element Method) structural analysis for the developed models, the safe snow depth was higher 2.3 times than a general roof structure, when elements of equal section modulus were used.

  • PDF

Azimuthal Distribution of Daily Maximum Temperatures Observed at Sideslopes of a Grass-covered Inactive Parasitic Volcano ("Ohreum") in Jeju Island (제주도 초지피복 기생화산("오름")의 방위별 일 최고기온 분포)

  • Seo, Hee-Chul;Jeon, Seung-Jong;Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.10 no.1
    • /
    • pp.25-31
    • /
    • 2008
  • Information on daily maximum air temperature is important in predicting the status of plants and insects, but the uneven and sparse distribution of weather stations prohibits timely access to the data in regions with complex topography. Since cumulative solar irradiance plays a critical role in determining daily maximum temperature on any sloping surfaces, derivation of a quantitative relationship between cumulative solar irradiance and the resultant daily maximum temperature is a prerequisite to development of such estimation models. Air temperatures at 8 sideslope locations with similar elevation and slope angle but aspect, circumventing a cone-shaped, grass-covered parasitic volcano (c.a., 570 m diameter for the bottom circle and 90m bottom-to-top height), were measured from June to December in 2007. Daily maximum temperatures from each location were compared with the average of 8 locations (assumed to be the temperature measured at a "horizontal reference" position). The temperature deviation at all locations increased with the day of year (or sun elevation) from summer solstice to winter solstice. Averaged over the entire period, the south facing location was warmer by $1^{\circ}C$ in daily maximum temperature than "horizontal reference" and the north facing location was cooler by $0.8^{\circ}C$ than the reference, resulting in the year round average south-north temperature difference of $1.8^{\circ}C$. In November, both south and north facing slopes showed the greatest deviation of $+2.0^{\circ}C$ and $-1.3^{\circ}C$, respectively in daily maximum temperature at monthly scale. On a daily scale, the greatest deviation was +3.8 and $2.7^{\circ}C$ at the south and north slope, respectively. The cumulative solar irradiance (on the slope for 4 hours from 11:00 to 15:00 TST) explained >60% of the variance in daily maximum temperature deviations among 8 locations, suggesting a feasibility of developing an estimation model for daily maximum temperature over complex topography at landscape scales.

- The Review of the Collar Consideration of G go-ri to Improve Drafting Method - (제도법 개선을 위한 저고리 깃 구성의 재고찰)

  • 정옥임
    • Journal of the Korean Home Economics Association
    • /
    • v.34 no.4
    • /
    • pp.249-263
    • /
    • 1996
  • According to the design method for constructing the G gori(the traditional Korean jacket)collar, there are differences in form after its completion. In the construction design of the midsection of the gusset as in that of the basic G gori, not only was the positioning of the two sides of the collar not smooth, but also, when the collar strip was attached, there would be an imbalance on one side or the other so that it was difficult to achieve symetry. Therefore in this project, by applying the pattern design of the gusset midsection to that of the collar midsection, not only did attaching the collar and the collar strip create a visual effect by equalizing the lengths of the tow sides, but the construction was also easy. This method of construction introduces the three-dimensional aspect of the human form in its conic, spherical and cylindrical aspects, so that, through schematizing the scientific character of Korea's clothing, its appropriateness is verified. As a matter of fact, since th-ere in no standardization of pattern whether for educational use or for mass-produced clothing, so that even the patterns used in computer-assisted design are executed according to the designer's personal skill, the reality is that after completion of construction the quality has not been uniform. For this schematization, inverse calculation of measurements pertaining to the calculation formula and of teaching materials has been referenced. In particular, the partial requlation of the calculation formula pertaining to the basic pattern construction, the method of making the collar midsection, and the construction method of the extreme and mean ratio adjustment can be adjusted for all measurements, thereby providing the establishment of a design criterion and the possibility of the standardization of construction methods. The production method for the pattern design is as follows: 1) The conic angle for the G gori's girth, length and neck width is fixed at 70 degrees. 2) The radius of the cone is B/2. 3) The calculation formula is B/4 + 1.5cm 4) The armhole formula is B/4, the same as in the basic method. 5) The width formula is B/10. 6) The ratio of the collar junction(width of collar + width of collar strip)to the gusset length is 5:8. 7) The length of the side seam is a length intersecting the armhole line and the conic radius (B/2), that is an arc that exceeds the length of the G gori's midsection; the component ratio of this length to the collar junction is accordingly 13:5. 8) The curve frame length of the back midsection is an arc exceeding B/4(the armhole line). 9) The ratio of the sleeve opening calculation formula to the armhole length is 8:5, forming an arc with the midsection length.

  • PDF

Partial Drainage Characteristics of Clayey Silt with Low Plasticity from the West Coast (서해안 저소성 점토질 실트 지반의 부분배수 특성)

  • Kim, Seok-Jo;Lee, Sang-Duk;Kim, Ju-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.9
    • /
    • pp.17-27
    • /
    • 2016
  • Parial drainage characteristics of clayey silt with low plasticity from the west coast (Incheon and Hwaseong) was analyzed using CPTU based existing correlation equations and compulsory replacement method. Generally, the estimated $OCRs={\kappa}{\cdot}((q_t-{\sigma}_{vo})/{\sigma}^{\prime}_{vo})$ using Powell and Quartman(1988) were higher than those obtained by the oeodometer tests. These trends were noticeable for the layers containing a lot of silty and sand soils. The assessment of partial drainage conditions was performed through Schnaid et al. (2004)'s equation; it is based on plotting the normalized cone resistance, $Q_t$ versus the pore pressure parameter, $B_q$ in combination with the strength incremental ratio, $s_u/{\sigma}^{\prime}_{vo}$ to the CPTU data. It is evident that more than half of the data fall in the range where $B_q$ < 0.3, corresponding to the domain in which the partial drainage prevails when testing normally consolidated soils at a standard rate of penetration (2 cm/s). To estimate the replacement depth of clayey silt with low plasticity, back analysis was carried out to evaluate the internal friction angle based on where the design depths are equal to the checked depths using bearing capacity equation. The internal friction angels obtained from the back analysis tended to increase as the plasticity index decreases, which is ranged approximately from ${\varphi}^{\prime}=2^{\circ}$ to ${\varphi}^{\prime}=7^{\circ}$.

Digital technique in diagnosis and restoration of maxillary anterior implant: a case report (디지털 기법을 활용한 상악 전치부의 진단 및 수복 증례)

  • Haemin, Bang;Woohyung, Jang;Chan, Park;Kwi-Dug, Yun;Hyun-Pil, Lim;Sangwon, Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.249-256
    • /
    • 2022
  • The implant prosthesis of anterior maxilla requires careful consideration in planning. In order to satisfy both esthetic and functional needs of a patient, fusion of intra-oral scan in Cone-beam computed tomography (CBCT) and facial scan can be considered. Bony structures and soft tissues captured in CBCT and occlusal surfaces of intra oral scan were incorporated into personal characteristics from facial scan. The patient had insufficient buccal bone on maxillary anterior area. The maxillary implants could not be placed on the most ideal position. However, the "top down" approach completed by computer-generated arranging of teeth in implant planning and surgery with surgical guide resulted in esthetically and functionally satisfying result regardless of the limitation. Careful diagnosis with digital technique and the usage of surgical guide resulted in successful surgery and esthetic restoration. The temporary fixed prostheses were designed, restored and evaluated. The patient was not satisfied with the first design of temporary prosthesis, which showed uneven space distribution between teeth due to the position of maxillary implant. The design was modified by changing proximal emergence contours and line angle to alter the perceived since of incisors. The patient was satisfied with the new design of provisional restoration. A digital occlusion analyzer (Arcus Digma II, KaVo, Leutkirch, Germany) was used to measure inherent condylar guidance and anterior guidance of a patient to provide a definitive prosthesis.