• 제목/요약/키워드: Conductor Loss

Search Result 220, Processing Time 0.038 seconds

Characteristic Analysis on Radio Propagation Path Loss Characteristics of Vertical Electric Dipole in Time Domain (시간영역에서 수직 다이폴의 전파경로손실 특성 해석)

  • Hong, Ic-Pyo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.7
    • /
    • pp.1558-1563
    • /
    • 2013
  • In this paper, we analyze the radio propagation path loss characteristics for the vertical electric dipole radiation over the perfect electric conductor(PEC) ground plane. Most research have been performed about the electromagnetic analysis of vertical electric dipole in free space for time domain or frequency domain. But this paper present the radio propagation path loss over PEC ground plane in time domain under the assumption of the vertical electric dipole as a base station. From the simulated results, the ground plane effect can change the location of near field from transmitting antenna and the transient responses at mobile are calculated. The results of this paper can be applied to surface radar or signal processing applications.

Analysis of a Tapered Rectangular Waveguide for V to W Millimeter Wavebands

  • Lee, Sangsu;Son, Dongchan;Kwon, Jae-Yong;Park, Yong Bae
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.4
    • /
    • pp.248-253
    • /
    • 2018
  • An electromagnetic boundary-value problem of a tapered rectangular waveguide is rigorously solved based on eigenfunction expansion and the mode-matching method. Scattering parameters of the tapered rectangular waveguide are represented in a series form and calculated in terms of different rectangular waveguide combinations. Computation is performed to analyze reflection and transmission characteristics. Conductor loss by surface current density is also calculated and discussed.

Design of a 2-Layer HTS Power Transmission Cable Core According to the effect of Winding Direction (연방향 영향을 고려한 2층 고온초전도 전력케이블 코어 설계)

  • 주진홍;김석환;조전욱;배준한;김해종;김해준;성기철;홍정표
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.58-61
    • /
    • 2003
  • A typical HTS power transmission cable has multi-layer conductor structure to increase the current capacity. The current distribution among the conductor tapes is controlled mainly by pitches and winding directions of the layers, because the inductance of the layer is determined by the pitch and the winding direction. However, usually the current is not evenly distributed among the layers. This paper describes a method to make the current distribution more uniform and hence reduce the AC loss. If we choose a good combination we can find the optimal pitches and make an even current distribution. We studied the effect of the winding direction on a 2-layer cable by a statistical way. Calculation results and discussions will be presented.

  • PDF

Zinc Loss Detection in ACSR Power Lines using the Removable Type of Eddy Current Sensor (착탈형 와류센서를 이용한 ACSR전선의 아연손실량 검출)

  • Jang, T.I.;Jo, S.B.;Kang, J.W.;Kang, Y.W.;Yang, B.M.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1963-1965
    • /
    • 2000
  • This paper deals with a problem of detecting the inner corrosion of the ACSR(Aluminum Conductor Steel Reinforced) power lines using a detector which consists of an ECT(Eddy Current Test) sensor, a constant current service, a signal processing unit, and a RF transmitter/receiver unit. The detector runs on the ACSR transmission line and inspects the corrosion of the conductor using the technic of the nondestructive eddy current test. The experimental result shows this detector can efficiently find the zinc loss in ACSR power lines.

  • PDF

Non Leaky Conductor-Backed CPW Based on Thin Film Polyimide on CMOS-grade Silicon for Ku-band Application

  • Lee, Sang-No;Lee, Joon-Ik;Yook, Jong-Gwan;Kim, Yong-Jun
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.4
    • /
    • pp.165-169
    • /
    • 2004
  • This paper reports a miniaturized conductor-backed CPW (CBCPW) bandpass filter based on a thin film polyimide layer coated on CMOS-grade silicon. With a 20 ${\mu}{\textrm}{m}$-thick polyimide interface layer and back metallization on the CMOS-grade silicon, the interaction of electromagnetic fields with the lossy silicon substrate has been isolated, and as a result a low-loss and low-dispersive CBCPW line has been obtained. Measured attenuation constant at 20 GHz is below 1.2 ㏈/cm, which is compatible with the CPW on GaAs. In addition, by using the proposed CBCPW geometry, miniaturized BPF for Ku band application is designed and its measured frequency response shows excellent agreement with the predicted value with validating the performances of the proposed CBCPW geometry for RFIC interconnects and filter applications.

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.822-828
    • /
    • 2001
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings. Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other. This may result in wiring failure of the neutral conductor and overloading of the distribution transformer. In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed [6]. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions. The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system. This remedies overloading and power loss of the system. The experimental results on a prototype validate the proposed control approach.

  • PDF

AC loss of a 50MVA HTS-cable sample in perfect shielding (완전차폐시 50MVA급 HTS-케이블 샘플의 교류손실)

  • Ma, Y.H.;Li, Z.Y.;Jin, H.B.;Ryu, K.;Lim, J.H.;Sohn, S.H.;Hwang, S.D.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.296_297
    • /
    • 2009
  • 다층구조의conductor와 shield로 구성되는 HTS-cable의 교류손실 특성 연구를 위하여 2005년부터 실증시험 중에 있는 22.9kV, 50MVA, 100m급 KEPCO HTS-cable system에 사용된 케이블과 동일한 두개의 short-sample에 대하여DC 및 AC 특성을 실험적으로 조사하였다. KEPCO HTS-cable system에서처럼 shield전류를 conductor와 크기는 같게 하고 방향을 반대로하여 수주기동안 AC pulse전류를 인가했을 때, shield의 임계전류가 conductor보다 작음에도 불구하고 conductor-lead에 대하여 측정된 AC loss가 shield의 것과 비교하여 약 1.5배 큰 것을 알 수 있었다

  • PDF

Dual-band Open Loop Antenna using Strip-conductor for an RFID Reader (RFID 리더용 이중대역 도체스트립 개방루프 안테나)

  • Lim, Jung-Hyun;Kang, Bong-Soo;Kim, Ji-Yoon;Kim, Heung-Soo;Yang, Doo-Yeong
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.63-64
    • /
    • 2006
  • In this paper, the open loop antenna using a strip-conductor for an RFID reader at dual-band frequency(910MHz, 2.45GHz) is proposed. The impedance is matched by varying the antenna parameters such as the length of strip-conductor and the gap of between two strip-conductors. Return loss and gain of designed antenna are -11.919dB, 2.5dBi at 910MHz, and -15.766dB, 5.65dBi at 2.45GHz, respectively.

  • PDF

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • Journal of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.151-158
    • /
    • 2003
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other This may result in wiring failure of the neutral conductor and overloading of the distribution transformer In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system This remedies overloading and power loss of the system The experimental results on a prototype validate the proposed control approach.

Selection Criteria for the Traction Power Supply Line of the Light Rail Transit System (경량전철 전차선 용량 선정방법)

  • Chung S.G.;Jeong R.G.;Cho H.S.;Han S.Y.;Lee A.H.;Baek B.S.
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.409-414
    • /
    • 2003
  • In this study we examined the method to select the size of the conductor rail for light rail system. Study results shows that using the conductor rail with lower resistivity requires fewer power substation, which results in lower construction cost. It also produces less copper loss. Therefore first choose the conductor rail with lowest resistivity and select the substation location, Next conduct computer simulation study to confirm it meets voltage requirement. if the minimum voltage is well above the required minimum voltage, substation number can probably be further reduced.

  • PDF