Application of a geophysical well log technique for determining permeability in borehole

  • Kim Y.;Park J.
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.432-436
    • /
    • 2003
  • Geophysical well logging techniques which are useful for delineating permeability of geological formation have been reviewed. A new technique for obtaining permeability using conductivity log technique has been discussed. This conductivity logging technique has been tested by monitoring the conductivity change within the model hole using borehole environment water and incoming-outgoing water of different salinity with constant flow rate by maintaining balance between inflow and outflow. Conductivity variation features depended mainly on flow rate, density contrasts due to salinity and temperature contrasts between fluid within the hole and incoming-outgoing fluid. The results of the experiment show uniform change of fluid conductivity within bore hole with time, and a fairly good correlation between the flow rate and the conductivity change rate. This conductivity logging technique is expected to be an efficient tool for determining permeability.

  • PDF

Journal of the Environmental Sciences A Study on the Operating Conditions to Eliminate Feedpipe Backmixing for Fast Competitive Reactions

  • Jang, Jeong-Gook;Jo, Myung-Chan
    • 한국환경과학회지
    • /
    • 제20권8호
    • /
    • pp.929-942
    • /
    • 2011
  • A novel conductivity technique was developed to detect penetration depth of the vessel fluid into the feedpipe. For a given reactor geometry, critical agitator speeds were experimentally determined at the onset of feedpipe backmixing using Rushton 6 bladed disk turbine (6BD) and high efficiency axial flow type 3 bladed (HE-3) impellers. The ratio of the feedpipe velocity to the critical agitator speed ($v_f/v_t$) was constant for either laminar or turbulent feedpipe flow regimes. Compared to the results of fast competitive reaction, feedpipe backmixing had to penetrate at least one feedpipe diameter into the feedpipe to significantly influence the yield of the side product. However, higher $v_f/v_t$ than that for L/d = 0 (position at the feedpipe end) of the conductivity technique is recommended to completely eliminate feedpipe backmixing in conservative design criteria. The conductivity technique was successful in all feedpipe flow conditions of laminar, transitional and turbulent flow regimes.

전기 도전율의 DC와 AC특성 (The DC and AC Properties of Electrical Conductivity)

  • 강전홍;김한준;유광민;박영태;한상옥;김종석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.599-600
    • /
    • 2005
  • The measurement method of electrical conductivity of the metal use a generally DC technique. Traceability to national standards in many countries is achieved using DC measurement technique and recently it's interested in AC technique. As a results for AC technique, the properties of electrical conductivity of non-ferrous and ferrous metals is decreasing at low frequency level.

  • PDF

불포화 투수계수함수에 대한 연구 (Determination of the Unsaturated Hydraulic Conductivity Function)

  • 황창수;김태형
    • 한국지반공학회논문집
    • /
    • 제20권3호
    • /
    • pp.47-51
    • /
    • 2004
  • 불포화 투수계수함수는 흙수분 특성곡선과 함께 불포화토를 이해 연구하는데 있어서 없어서는 안 될 중요한 요소이다. 일반적으로 불포화 투수계수함수를 직접 측정하기에는 많은 어려움이 있기에, 흙수분 특성곡선에 근거한 예측함수를 사용하여 불포화 투수계수함수를 구하곤 했다. 본 연구에서는 이러한 예측함수를 사용하지 않고, 피스톤 펌프기법과 역해석 기법을 이용한 불포화 투수계수함수를 구하는 방법을 제시한다. 이렇게 구해진 불포화 투수계수함수는 예측함수를 사용하지 많았기 때문에, 흙수분 특성곡선으로부터 독립적이며 예측함수를 사용한 경우보다 보다 정확한 불포화토의 특성을 보여준다.

Van der Pauw 측정법을 이용한 금속 도전율의 직류와 교류특성 (DC and AC Characterization of Metals Conductivity using the van der Pauw Measurement Method)

  • 강전홍;한상옥
    • 전기학회논문지P
    • /
    • 제56권4호
    • /
    • pp.157-160
    • /
    • 2007
  • The van der Pauw technique is one of the popular methods for determining the conductivity of flat metal samples. Traceability of the national standard for the conductivity has been achieved by direct current measurement techniques in national measurement institutes of many countries. But recently, alternative current measurement techniques for determining the conductivity of flat metal samples is also interested. In this study, we measured the conductivity of non-ferrous and ferrous flat metals at alternative current using van der Pauw technique. As measurement results, the conductivities of the samples were decreased according to increasing the test frequency even though the decreasing ratio was different.

2파장 펌프-프로브 기법을 이용한 질화규소 박막의 열물성 평가 (Thermal Property Evaluation of a Silicon Nitride Thin-Film Using the Dual-Wavelength Pump-Probe Technique)

  • 김윤영
    • 한국재료학회지
    • /
    • 제29권9호
    • /
    • pp.547-552
    • /
    • 2019
  • In the present study, the thermal conductivity of a silicon nitride($Si_3N_4$) thin-film is evaluated using the dual-wavelength pump-probe technique. A 100-nm thick $Si_3N_4$ film is deposited on a silicon (100) wafer using the radio frequency plasma enhanced chemical vapor deposition technique and film structural characteristics are observed using the X-ray reflectivity technique. The film's thermal conductivity is measured using a pump-probe setup powered by a femtosecond laser system of which pump-beam wavelength is frequency-doubled using a beta barium borate crystal. A multilayer transient heat conduction equation is numerically solved to quantify the film property. A finite difference method based on the Crank-Nicolson scheme is employed for the computation so that the experimental data can be curve-fitted. Results show that the thermal conductivity value of the film is lower than that of its bulk status by an order of magnitude. This investigation offers an effective way to evaluate thermophysical properties of nanoscale ceramic and dielectric materials with high temporal and spatial resolutions.

RF Conductivity Measurement of Conductive Zell Fabric

  • Nguyen, Tien Manh;Chung, Jae-Young
    • Journal of electromagnetic engineering and science
    • /
    • 제16권1호
    • /
    • pp.24-28
    • /
    • 2016
  • This study presents a conductivity measurement technique that is applicable at radio frequencies (RF). Of particular interest is the measurement of the RF conductivity of a flexible Zell fabric, which is often used to implement wearable antennas on clothes. First, the transmission coefficient is measured using a planar microstrip ring resonator, where the ring is made of a Zell fabric. Then, the fabric's conductivity is determined by comparing the measured transmission coefficient to a set of simulation data. Specifically, a MATLAB-based root-searching algorithm is used to find the minimum of an error function composed of measured and simulation data. Several error functions have been tested, and the results showed that an error function employing only the magnitude of the transmission coefficient was the best for determining the conductivity. The effectiveness of this technique is verified by the measurement of a known copper foil before characterizing the Zell fabric. The conductivity of the Zell fabric at 2 GHz appears to be within the order of $10^4S/m$, which is lower than the DC conductivity of $5{\times}10^5S/m$.

플로우 펌프기법을 이용한 포천지역 화강 풍화토의 함수특성곡선 (Soil-Water Characteristic Curve of Weathered Granite Soils in Pocheon Area using Flow Pump Technique)

  • 이강일;이준용;백원진
    • 한국농공학회논문집
    • /
    • 제51권1호
    • /
    • pp.11-20
    • /
    • 2009
  • Flow pump technique was used in order to determine the soil-water characteristic curve of weathered granite soils in Pocheon area. This technique enables measurement to be more convenient and accurate as it is based on the CU condition of triaxial compression test. Besides, it is also able to measure dry and moisture curves continuously since the test is controled by means of a computer automatically. In this study, not only a hydraulic conductivity of weathered granite soils at fully saturated state in Pocheon area, but also a soil-water characteristic curve throughout unsaturate flow tests were determined. In addition, Brooks and Corey's model and Genuchten's model were used to simulate the soil-water characteristic curve. On the basis of the simulation an unsaturate hydraulic conductivity was predicted.

굴착영향영역(EDZ) 투수특성의 실험적 평가기술 (In-Situ Evaluation Technique for Hydraulic Conductivity in Excavation Disturbed Zone (EDZ))

  • 김형목;류동우;신중호
    • 터널과지하공간
    • /
    • 제18권2호
    • /
    • pp.91-97
    • /
    • 2008
  • 본 고에서는 공동굴착에 따른 주변 영향영역 암반의 투수 특성 변화를 간접적 방법이 아닌 직접적으로 측정 가능한 현장수리시험장비를 소개하고 국내 지하연구시설(URL) 현장실험에 적용한 결과를 수록하였다. 굴착공동 주변 수리학적 EDZ의 투수계수 측정의 정밀도 향상을 위해서는 잘 설계된 시험장비와 함께 시험결과를 분석 평가하는 기술이 통합된 시스템 개발이 필요할 것으로 생각된다. 이를 통해 지하수면 아래 건설되는 공동의 안정성 평가, 방배수 시스템 및 그라우팅 설계의 신뢰도 향상에 기여할 수 있을 것으로 기대된다.

흙-벤토나이트월에 대한 전기전도도 모니터링 기법의 적용성 평가 (Applicability of Electrical Conductivity Monitoring Technique for Soil-bentonite Barrier)

  • 오명학;유동주;김용성;박준범
    • 한국지반공학회논문집
    • /
    • 제23권7호
    • /
    • pp.47-55
    • /
    • 2007
  • 본 연구에서는 흙-벤토나이트월과 같은 차단벽체에 대한 전기전도도 모니터링 기법의 적용성을 평가하였다. 벤토나이트 함량, 투수계수 및 중금속 농도에 따른 전기전도도 변화를 파악하기 위하여 투수실험과 주상실험을 실시하였다. 흙-벤토나이트 혼합 다짐시편의 전기전도도는 벤토나이트 함량이 증가함에 따라 선형적으로 증가하는 경향을 나타내었다. 또한 흙-벤토나이트 차단벽체의 투수계수는 벤토나이트 함량과 반비례하는 경향을 나타내었으며, 전기전도도와도 반비례하는 경향을 나타내었다. 주상실험을 통하여 전기전도도 파과곡선과 농도 파과곡선을 동시에 구할 수 있었다. 이 결과는 전기전도도 측정기법이 벽체 내부의 임의 지점에서 중금속의 이동을 감지하고 오염물질의 누출 가능성을 확인하는 유용한 방법으로 활용될 수 있음을 나타낸다. 본 연구결과에 의하면 전기전도도 측정기법이 차단벽체 모니터링에 효과적으로 적용될 수 있을 것으로 기대된다.