• Title/Summary/Keyword: Conditioning simulation

Search Result 999, Processing Time 0.023 seconds

Neural-based Blind Modeling of Mini-mill ASC Crown

  • Lee, Gang-Hwa;Lee, Dong-Il;Lee, Seung-Joon;Lee, Suk-Gyu;Kim, Shin-Il;Park, Hae-Doo;Park, Seung-Gap
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.12 no.6
    • /
    • pp.577-582
    • /
    • 2002
  • Neural network can be trained to approximate an arbitrary nonlinear function of multivariate data like the mini-mill crown values in Automatic Shape Control. The trained weights of neural network can evaluate or generalize the process data outside the training vectors. Sometimes, the blind modeling of the process data is necessary to compare with the scattered analytical model of mini-mill process in isolated electro-mechanical forms. To come up with a viable model, we propose the blind neural-based range-division domain-clustering piecewise-linear modeling scheme. The basic ideas are: 1) dividing the range of target data, 2) clustering the corresponding input space vectors, 3)training the neural network with clustered prototypes to smooth out the convergence and 4) solving the resulting matrix equations with a pseudo-inverse to alleviate the ill-conditioning problem. The simulation results support the effectiveness of the proposed scheme and it opens a new way to the data analysis technique. By the comparison with the statistical regression, it is evident that the proposed scheme obtains better modeling error uniformity and reduces the magnitudes of errors considerably. Approximatly 10-fold better performance results.

High Efficiency H-Bridge Multilevel Inverter System Using Bidirectional Switches (양방향 스위치를 이용한 고효율 H-Bridge 멀티레벨 인버터 시스템)

  • Lee, Hwa-Chun;Hwang, Jung-Goo;Kim, Sun-Pil;Choi, Woo-Seok;Lee, Sang-Hyeok;Park, Seong-Mi;Park, Sung-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.16-26
    • /
    • 2014
  • This paper proposes new 13-level inverter topology and DC/DC converter buck-boost structure topology for multilevel, compounding uni-directional and bi-directional switches, and proposes high-efficient multilevel inverter system in which the proposed two PCS(Power Conditioning System) was connected in series. In proposed multilevel inverter of forming a output 13-level phase voltage by using total 18 switching parts, Then bi-directional switch has a characteristic of reducing conduction loss and controlling the reactive power effectively by separating electrically from the neutral point. DC/DC converter for supplying in dependent 3 DC voltage to the proposed multi-level inverter generates 180-degree phase shifted PWM by the symmetrically combined structure of 2 buck-boost converter and twice switching frequency efficiency can be obtained, meanwhile, the converter can step up/down the output voltage and 20% output can be generated comparing the input voltage. This proposed system is verified with the simulation and laboratory test.

Context Aware Services using Multi-Environmental Sensors and Its application for Ubiquitous Home Networks

  • Quang, Bui Dang;Torregoza, John Paul M.;Hwang, Won-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.6
    • /
    • pp.786-798
    • /
    • 2007
  • As we go about our daily lives, people often collect surrounding information and adapt to the situation. Computer development trends show that one wants computers to work like human beings, i.e. computers can sense its context and adapt corresponding to context changes. To implement this expectation, a context aware service layer is needed. In this layer, sensors capture its environment and send this information to the service center. Considering received information as its context, the service center seeks the suitable operation according to the context. Tills paper presents a context aware service which is applied in controlling air-conditioner. The air-conditioner includes sensors which are installed at some special positions in a room. Each of these sensors gathers comfort-influenced information like temperature, humidity and sends them to air-conditioner. The air-conditioner adapts its operation to the environment according to the sensed information. To control the air-conditioner effectively, we use a genetic algorithm which is suitable in adaptation issues. The simulation shows that the room condition can be maintained at a comfortable level by using context-aware services in the operation of the air-conditioning system.

  • PDF

Optimal pre-conditioning and support designs of floor heave in deep roadways

  • Wang, Chunlai;Li, Guangyong;Gao, Ansen;Shi, Feng;Lu, Zhijiang;Lu, Hui
    • Geomechanics and Engineering
    • /
    • v.14 no.5
    • /
    • pp.429-437
    • /
    • 2018
  • In order to reduce deformation of roadway floor heave in deep underground soft rockmass, four support design patterns were analyzed using the Fast Lagrangian Analysis of Continua (FLAC)3D, including the traditional bolting (Design 1), the bolting with the backbreak in floor (Design 2), the full anchorage bolting with the backbreak in floor (Design 3) and the full anchorage bolting with the bolt-grouting backbreak in floor (Design 4). Results show that the design pattern 4, the full anchorage bolting with the bolt-grouting backbreak in floor, was the best one to reduce the deformation and failure of the roadway, the floor deformation was reduced at 88.38% than the design 1, and these parameters, maximum vertical stress, maximum horizontal displacement and maximum horizontal stress, were greater than 1.69%, 5.96% and 9.97%. However, it was perfectly acceptable with the floor heave results. The optimized design pattern 4 provided a meaningful and reliable support for the roadway in deep underground coal mine.

High Performance Switched Reluctance Motor Drive for Automobiles using C-dump Converters

  • Song Sang-Hoon;Yoon Yong-Ho;Lee Tae-Won;Kim Yeun-Chung;Won Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.992-996
    • /
    • 2004
  • Small electric motors in an automobile perform various tasks such as engine cooling, pumping, and in heating, ventilating, and air-conditioning (HVAC) system. At present, most of dc motors are supplied by 12V or 24V batteries. However, DC motors surfer from lack of efficiency, low life cycles and unreliability. Therefore, there is a growing interest in substituting DC motors for advanced AC motors including switched reluctance motors. Although there are several other forms SRM converters, they are either unsatisfactory to the control performance or unsuitable for the 12V-battery powered 3-phase SRM drives. Taking into account the requirement for effective operation and simplicity structure of converter in the limited internal environment of automobiles, the author inclines toward selecting the modified C-dump converter as well as the energy efficient C-dump converter. This is so that more economical and efficient converter topology in automobile industries can be utilized. This paper describes the foundation for the design and development of a 12V-250W-3000rpm SRM drives for automobiles. Furthermore, complete circuit, computer simulation and experiment results are presented to verify the performance of the C-dump converters.

  • PDF

Study on Thermal Comfort in according to Rate of Opening Windows of Flat-type Apartment (판상형 아파트의 창문개폐율에 따른 열쾌적도 분석)

  • Kim, Sung Gil
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.93-98
    • /
    • 2013
  • The purpose of this study is to analyze the rate of opening windows that makes residents of a flat-type apartment feel pleasant in summer time. A few conditions were simulated on the wind flow that pass through internal and external spaces of the flat-type apartment, utilizing CFX program. The simulation was made with the criteria for the rates of opening window at 20%, 50%, 70% and 100%. When the rate of window opening was more 50%, the wind speed(more than 1m/s) that makes the residents feel pleasant was observed in more 60% of the internal space. When the all windows of the apartments were opened, the heat island phenomenon was almost disappeared and the pleasant wind flow was more evenly distributed in the external spaces. If residents of apartments recognize the result of this study and practice in agrement on opening windows in summer, it is expected to contribute to minimizing the energy consumption for air conditioning.

A Study of Modular Architecture's Design to Dwelling Environment in Antarctica (극한지 모듈러 건축물의 설계, 시공 및 거주환경에 대한 연구)

  • Lee, Won-Hak;Song, Young-Hak;Lim, Seok-Ho
    • Journal of the Korean housing association
    • /
    • v.25 no.2
    • /
    • pp.11-18
    • /
    • 2014
  • This study looked at designing, building and operating temporary camp, the first structures that South Korea built in the Antarctica. While there may be differences in accordance with the topography, ground surfaces in the Antarctica are covered broken stones, glaciers and snow. Hence, such topographical characteristics should be taken into account when conducting any construction work. To ensure successful assembly construction in the Antarctica using modules, prior trial assembly work should be done in Korea to identify any possible trouble in the actual construction process. Assuming that the workers will have to spend at least one winter in the temporary camp, the work will be more severely affected by adverse weather conditions and snow drift, resulting in the need to clear snow. This can be by designing roofs with curved surfaces. Also, quantitative effects will need to be verified through simulation and actual measurement. It will also be necessary to assess the camp's thermal environment and examine its air-conditioning methods. To identify the temporary camp's thermal system, the temperatures and humidities were measured, and the heating system was designed not to offer automatic control or desired value selection functions.

Analysis of voltage sag effect at load side during fault according to change of power system condition (계통조건(系統條件) 변경(變更)에 따른 고장시(故障時) 부하측(負荷側)의 순간전압강하(瞬間電壓降下) 영향분석(影響分析))

  • Yoon, Gi-Seob;Baik, Seung-Do;Gu, Sung-Wan;Lee, Chong-Soo;Lee, Hong-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.156-158
    • /
    • 2002
  • In this paper, we analyze about voltage sag effect at load side during fault according to change of power system condition. through the case studies, we find that there is no close connection between substation bus transfer and voltage sag during fault. however, we find that other feeder connecting with the faulted transmission is directly affected by fault type and magnitude, therefore, the main subject can be divided into the utility and customer side countermeasures, utilities concentrate their effort to prevent the faults and to modify the fault clearing practice in power system. however, the faults in power system can never be completely eliminated. therefore, customer side solutions usually involve the power conditioning equipment for sensitive loads aiso, we investigate that the several methods to reduce the number and severity of voltage sag and to dull the sensitivity of equipment for voltage sag have developed. moreover, about SEMI, the industry association for the semiconductor two voltage sag immunity standards.(SEMI F47, SEMI F42) The simulation is accomplished by PSS/E 26.

  • PDF

Single-Chip Controller Design for Piezoelectric Actuators using FPGA (FPGA를 이용한 압전소자 작동기용 단일칩 제어기 설계)

  • Yoon, Min-Ho;Park, Jungkeun;Kang, Taesam
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.7
    • /
    • pp.513-518
    • /
    • 2016
  • The piezoelectric actuating device is known for its large power density and simple structure. It can generate a larger force than a conventional actuator and has also wide bandwidth with fast response in a compact size. To control the piezoelectric actuator, we need an analog signal conditioning circuit as well as digital microcontrollers. Conventional microcontrollers are not equipped with an analog part and need digital-to-analog converters, which makes the system bulky compared with the small size of piezoelectric devices. To overcome these weaknesses, we are developing a single-chip controller that can handle analog and digital signals simultaneously using mixed-signal FPGA technology. This gives more flexibility than traditional fixed-function microcontrollers, and the control speed can be increased greatly due to the parallel processing characteristics of the FPGA. In this paper, we developed a floating-point multiplier, PWM generator, 80-kHz power control loop, and 1-kHz position feedback control loop using a single mixed-signal FPGA. It takes only 50 ns for single floating-point multiplication. The PWM generator gives two outputs to control the charging and discharging of the high-voltage output capacitor. Through experimentation and simulation, it is demonstrated that the designed control loops work properly in a real environment.

Multi-Central System for Large Scale PV Power Generation (대용량 태양광 발전용 멀티센트럴 시스템)

  • Park, Jong-Hyoung;Ko, Kwang-Soo;Kim, Heung-Geun;Nho, Eui-Cheol;Chun, Tae-Won
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.427-432
    • /
    • 2012
  • This paper proposes efficient operation method of PV system consisted of multi-central which is suitable for large scale system. The multi-central system used switch at a DC-link and applied proposed algorithm can improve the efficiency and the reliability on the existing system. This algorithm, with advantage of Multi-Central system can minimize the effect of different characteristic of each PV array due to a shadow or damaged PV cell. Each system is analysed and maximum power point tracking control, DC-link voltage control and output current control is used commonly. The validity is verified after comparing of the existing system and proposed system by simulation.

  • PDF