• Title/Summary/Keyword: Conditioning diagnosis

Search Result 80, Processing Time 0.019 seconds

A Study on Estimating Real-time Thermal Load During GHP Operation in Heating Mode (GHP 난방 모드 운전시 실시간 부하 추정방법에 관한 연구)

  • Seo, Jeong-A;Shin, Young-Gy;Oh, Se-Je;Jeong, Sang-Duck;Ji, Kyoung-Chul;Jeong, Jin-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.32-37
    • /
    • 2011
  • The present study has been conducted to propose an algorithm regarding real-time load estimation of a gas engine-driven heat pump. In the study, thermal load of an indoor unit is estimated in terms of air-side and refrigerant-side. The air-side estimation is based on a typical heat exchanger model and is found to be in good agreement with experimental data. When it comes to the refrigerant-side load, a pressure difference across a valve must be estimated. For the estimation, it is assumed to be proportional to a bigger pressure difference that is available either by measurement or by estimation. Relative good agreement between the air- and refrigerant-sides suggests that the assumption may be plausible for the load estimation. The summed flow rate of all of indoor units is in good agreement with the throughput of the compressor which are calculated from the manufacturer's software. Accordingly, estimated thermal loads are also in good agreement. The proposed algorithm may be further developed for improved control algorithm and fault diagnosis.

A study on the 3-step classification algorithm for the diagnosis and classification of refrigeration system failures and their types (냉동시스템 고장 진단 및 고장유형 분석을 위한 3단계 분류 알고리즘에 관한 연구)

  • Lee, Kangbae;Park, Sungho;Lee, Hui-Won;Lee, Seung-Jae;Lee, Seung-hyun
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.8
    • /
    • pp.31-37
    • /
    • 2021
  • As the size of buildings increases due to urbanization due to the development of industry, the need to purify the air and maintain a comfortable indoor environment is also increasing. With the development of monitoring technology for refrigeration systems, it has become possible to manage the amount of electricity consumed in buildings. In particular, refrigeration systems account for about 40% of power consumption in commercial buildings. Therefore, in order to develop the refrigeration system failure diagnosis algorithm in this study, the purpose of this study was to understand the structure of the refrigeration system, collect and analyze data generated during the operation of the refrigeration system, and quickly detect and classify failure situations with various types and severity . In particular, in order to improve the classification accuracy of failure types that are difficult to classify, a three-step diagnosis and classification algorithm was developed and proposed. A model based on SVM and LGBM was presented as a classification model suitable for each stage after a number of experiments and hyper-parameter optimization process. In this study, the characteristics affecting failure were preserved as much as possible, and all failure types, including refrigerant-related failures, which had been difficult in previous studies, were derived with excellent results.

A Development of the On-line Maintenance and Management System for the HVAC system Using IT (IT를 활용한 공조설비의 온라인 유지관리시스템 개발)

  • Lee, Tae-Won;Kim, Yong-Ki;Kang, Sung-Ju;Woo, Nam-Sub
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.48-53
    • /
    • 2008
  • The performances of the building service equipment relay on the individual superintendent's share for the assessment of performance, fault detection, deterioration diagnosis of the building service equipment. A major use of building energy management system(BEMS) is for monitoring plant and building's energy consumption. National building management system (N-BMS) presented in this study links buildings into a network group in order to monitor and control the buildings. How to construct the N-BMS was considered to save energy resource and to conserve performance of building service equipment. The FEMIS, facility, energy/environmental management & information system, for building service offer management process integrated with BAS, FMS and EMS and so on.

  • PDF

A Construction of the N-BMS Focused on the Building Service Equipment (N-BMS : National Building Management System) (건물 군관리시스템 구축방안)

  • Lee, Tae-Won;Kim, Yong-Ki;Kang, Sung-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.149-154
    • /
    • 2007
  • Now, in Korea, the performances of the building service equipment relay on the individual superintendent's share for the assessment of performance, fault detection, deterioration diagnosis of the building service equipment. As the result, very different quality of the performance or the durability of equipment is being obtained with his skill and effort and it is also not easy to assess that quality. This finally lead to the waste of labor force and the operating cost due to the high-cost, low-efficiency system. How to construct the N-BMS was considered to save energy, resource and to conserve performance of building service equipment. The FEMIS, facility, energy/environmental management & information system, for building service offer management process integrated with BAS, FMS and EMS and so on.

  • PDF

Phonetic improvement by adjusting the shape of the anterior palate of the maxillary complete denture: a case report (상악 총의치 전방 구개 부위 형태 조정을 통한 발음개선 증례)

  • Yoon, Myeong Ah;Lee, HagYoung;Kim, Jee Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.37-43
    • /
    • 2022
  • Patients tend to return to normal pronunciation patterns after fitting new dentures. However, for some patients, it takes a long time to adapt the new complete denture. In this case, the patient came to the hospital at the address of wanting to remake dentures due to wear and tear. After diagnosis through clinical and radiological examination, the maxillary complete denture and mandibular removable partial denture were remade. The patient complained whistling /s/ sound at the first check-up after placement of the new denture. The anterior palatal area of polished surface of the new maxillary complete denture was concave comparing to old denture, and this was the cause of the whistling /s/ sound. A tissue conditioning material was applied to the maxillary complete denture and patient made /s/ sound. The tissue conditioning material was replaced with self-curing type denture base resin, and the patient was immediately satisfied with clear /s/ sound. As an objective assessment, palatogram and speech analytics software was applied. In this case, a patient who received denture treatment complaining of difficulty in pronunciation underwent immediate denture repair, which resulted in patient satisfaction and improved pronunciation through objective evaluation.

A comparative evaluation of $CO_2$ and erbium-doped yttrium aluminium garnet laser therapy in the management of dentin hypersensitivity and assessment of mineral content

  • Belal, Mahmoud Helmy;Yassin, Abdulaziz
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.5
    • /
    • pp.227-234
    • /
    • 2014
  • Purpose: Dentin hypersensitivity is a potential threat to oral health. Laser irradiation may provide reliable and reproducible treatment but remains controversial. The present study aimed to evaluate the effects of $CO_2$ or erbium-doped yttrium aluminium garnet (Er:YAG) laser therapy, and to assess mineral content. Methods: Eighteen human single-rooted teeth affected with advanced periodontitis were obtained. Buccal and lingual surfaces were planed to form 36 specimens. Ethylenediaminetetraacetic acid gel (24%) was applied to remove the smear layer and simulate hypersensitive teeth. The experimental groups were: group 1, control (no irradiation); group 2, $CO_2$ laser (repetitive pulsed mode, 2 W, $2.7J/cm^2$); and group 3, Er:YAG laser (slight contact mode, 40 mJ/pulse and 10 Hz). To evaluate dentinal tubule occlusion, six specimens per group (2-mm thickness) were prepared and observed using scanning electron microscopy (SEM) for calculation of the occlusion percentage. To evaluate the mineral content, six specimens per group (0.6-mm thickness) were used, and then the levels of Ca, K, Mg, Na, and P were measured by inductively coupled plasma-atomic emission spectrometry. In addition, the surface temperature of the specimens during laser irradiation was analyzed by a thermograph. Results: The SEM photomicrographs indicated melted areas around exposed dentinal tubules and a significantly greater percentage of tubular occlusion in the $CO_2$ and Er:YAG laser groups than the control, and in the Er:YAG group than the $CO_2$ laser group. In addition, no significant differences were noted among the experimental groups for the mineral elements analyzed. The $CO_2$ laser group showed an evident thermal effect compared to the Er:YAG group. Conclusions: $CO_2$ and Er:YAG laser are effective in treating dentin hypersensitivity and reducing its symptoms. However, the Er:YAG laser has a more significant effect; thus, it may constitute a useful conditioning item. Furthermore, neither $CO_2$ nor Er:YAG lasers affected the compositional structure of the mineral content.

A Study on the Facility and Equipment of Laboratory Medicine in General Hospital - Focused on more than 550 bed sized hospitals (종합병원 진단검사의학과 검사실의 시설 설비 현황 조사 - 550 병상 이상 종합병원을 중심으로)

  • Kim, Youngaee;Song, Sanghoon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.1
    • /
    • pp.73-84
    • /
    • 2020
  • Purpose: Though Korean healthcare services have been upgraded, infection and fire had been broken out in general hospitals. And higher concerns about quality assessment made it to clinical laboratory design guideline studies. So, this study investigates the facilities, equipment and personnel of laboratory medicine focusing on more than five hundred fifty bed hospital, and contributes to make guidelines for safety and efficiency in lab. Methods: Questionnaires to supervisor technologist and field surveys to medical laboratories in korean hospitals have been conducted for the data collection. 16 answers have been analysed statistically by MS Excel program. Results: Most of the sample tests such as hematology, clinical chemistry, immunology, transfusion, urinalysis, microbiology and molecular diagnosis are performed by more than 80% in large sized general hospital laboratory. In the test methods, automatic analyzers are used up to 80%, total laboratory automation up to 43% in clinical chemistry and immunology, and manual tests in all sorts of the test. There are placed in single lab or two and three labs above the ground, which are all in semi-open lab. There is some correlation with the number of specimens and the number of lab people depending on the number of hospital beds. Laboratory environment shows that work distance is good, but evacuation path width, visibility, separation of staff area from automatic analyzer, and equipment installations are needed to have more spaces and gears. Most of the infection controls are equipped with mechanical ventilation, air-conditioning, washbasin and wastewater separation, BSC installation and negative pressure lab room. Implications: Although the laboratory space area is calculated considering the number of hospital beds, type of tests and number of staff, hospital's expertise and the samples numbers per year should be taken into account in the planning of the hospital.

Demand Analysis of Technology Development for Smart Village based on Community Activities (공동체 활동을 기반으로 한 스마트빌리지 기술개발 수요분석)

  • Park, So Yeon;Cho, Hyejin;Jung, Nam-Su
    • Journal of Korean Society of Rural Planning
    • /
    • v.26 no.2
    • /
    • pp.117-126
    • /
    • 2020
  • In this study, demands of smart technology development were analyzed for rural village communities. Questionnaire items were derived by grasping the current status of information and communication technology. 49 villages in 8 regions were selected and surveys and statistical analysis were conducted. The main results of the study are as follows. First, 92% of community leaders use smartphones, search for information (38%), communicate with the Internet (36%) using smartphones, use KakaoTalk (31%), and Facebook (24%). Second, in the rural and urban exchange activities, promote support information service (51%) and promote method suggestion service (48.5%) showed that the demand for services in promote field was high. It is linked to the creation of economic opportunities. Third, in the income and production activities, demand for distribution services technology (39.3%) was high in the field of production and distribution, and cold chains that help maintain freshness until food, such as meat, fish, and vegetables are delivered to consumers when agricultural products are distributed. The constant temperature control system needs to be actively introduced. Fourth, autonomy activities showed the highest demand for air conditioning and control systems (34.2%) of community building, and the lowest demand for electronic voting (9.4%) and videoconferencing (9.4%) services. Lastly, in the general activity area of the community, the demand for technology of emergency services (37.1%) and health self-diagnosis service (35.4%), which are technologies in the welfare sector, ranked first and second respectively.

Implementation and Evaluation of the LUTS Diagnosis System Using FPGA (FPGA를 이용한 LUTS 진단 시스템 구현 및 평가)

  • Jeong, Do-Un;Chung, Wan-Young;Jeon, Gye-Rock
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.1
    • /
    • pp.6-14
    • /
    • 2007
  • The purpose of urodynamic investigation is to determine information on the function of the urinary system. One of the most frequently used measurement procedures in urodynamics is filling and voiding cystometry using invasive method. But in this method transurethral catheter is use and it makes patients uncomfortable. The aim of this study was to implement the system that could evaluate the function of urinary tract with noninvasive and comfortable method. Therefor in this study, a sensor and measuring system were implemented to measure uroflow, urophonography and noninvasive bladder pressure signal during urination for diagnosing the LUTS(lower urinary tract symptoms) using noninvasive method. The implemented system compose of the sensor parts, signal conditioning parts, system control parts using FPGA and PC monitoring program. For the evaluation of the implemented system, the simulation of system's control part was performed and the model system for the lower urinary system was designed. From the evaluation of the model system, the mean error rate of the uroflow measurement part was 1.08% and coefficient of variation was 1,48. And the mean error rate of the noninvasive bladder pressure measurement part was 2.41% and coefficient of variation was 2.81. urophongraphy signal analysis was accomplished in a time domain and frequency domain. Average RMS power was used in a time domain analysis, and MF was used in a frequency domain analysis. From the evaluation of the model system average RMS power and MF was dependent on the occlusion degree significantly and median frequency range of $60{\sim}160Hz$ was correlated with the occlusion.

  • PDF

Endocrine dysfunction after bone marrow transplantation during childhood and adolescence (소아 및 청소년기에서 골수이식 후에 발생할 수 있는 내분비 기능 부전)

  • Jin, Hye Young;Choi, Jin-Ho;Im, Ho-Joon;Seo, Jong-Jin;Moon, Hyung-Nam;Yoo, Han-Wook
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.3
    • /
    • pp.420-427
    • /
    • 2010
  • Purpose : Several complications can occur in patients who received bone marrow transplantation (BMT) during childhood and adolescence. This study aims to investigate endocrine dysfunctions after BMT so that better care can be provided to care for long-term survivors of BMT. Methods : One hundred patients (61 males, 39 females) were included in this study. Clinical parameters such as initial diagnosis, age at BMT, conditioning regimen, presence of graft-versus-host disease (GVHD), growth pattern, thyroid function, and pubertal status were retrospectively reviewed to evaluate risk factors associated with endocrine dysfunction. Results : Height standard deviation score (SDS) at BMT, after 1 year of BMT, and at the last visit were $0.08{\pm}1.04$, $-0.09{\pm}1.02$, and $-0.27{\pm}1.18$, respectively (P =0.001). Height SDS significantly decreased in patients who received total body irradiation (TBI) (P =0.017). One of the patients who received TBI demonstrated growth hormone deficiency. Thirty (31.9%) of 94 patients had compensated hypothyroidism. Incidence of compensated hypothyroidism was higher among those who had GVHD (odds ratio 2.82, P =0.025). Of the 32 patients (17 males, 15 females) who were over 14 years in male and 13 years in female at the last visit, 16 (3 males, 13 females) had increased luteinizing hormone (LH) or follicle-stimulating hormone (FSH). Abnormal elevation of LH or FSH was more common in females (odds ratio 30.3, P =0.001). Conclusion : The most common endocrine dysfunction was ovarian insufficiency. Regular check-up for endocrine function needs to be required due to high incidence of endocrine dysfunction in patients with BMT.