• Title/Summary/Keyword: Conditioners

Search Result 312, Processing Time 0.028 seconds

Effects of the Temperature Glide and Superheat of R407C on the Performance of Evaporator (R407C의 온도구배와 과열도가 증발기 성능에 미치는 영향)

  • 김창덕;전창덕;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.852-859
    • /
    • 2003
  • R407C is considered as an alternative refrigerant of R22 for air conditioners. An experiment was carried out to investigate the characteristics of the evaporation heat transfer and pressure drop for refrigerant R407C flowing in a fin-and-tube heat exchanger used for commercial air-conditioning unit. The experimental data were useful in analyze the effects of the temperature glide and superheat for R407C. Test were conducted at the conditions of inlet refrigerant evaporation temperature of 7$^{\circ}C$, inlet air relative humidity of 50%, and refrigerant mass fluxes varying from 150 to 250 kg/m$^2$s. Representative results show that the heat exchanger performance for R407C evaporation is significantly affected by the change of the flow pattern from two-phase to super-heated vapor flow.

Sensorless Control for a PM Synchronous Motor in a Single Piston Rotary Compressor

  • Cho Kwan-Yuhl
    • Journal of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.29-37
    • /
    • 2006
  • A sensorless control for an IPM (Interior Permanent Magnet) synchronous motor in a single piston rotary compressor is presented in this study. The rotor position is estimated from the d-axis and q-axis current errors between the real system and a motor model of the position estimator. The torque pulsation of the single piston rotary compressor is compensated to reduce speed ripples, as well as, mechanical noise and vibration. The proposed sensorless drive enables the compressor to operate at a lower speed which increases energy savings and reduces mechanical noise. It also gives high speed operations by a flux weakening control for rapid air-cooling and heating of the heat pump air-conditioners.

Utility Interactive Inverter with High-frequency Link for Photovoltaic Power System (고주파링크 방식을 이용한 계통연계형 태양광발전시스템)

  • Jung, Y.S.;Yu, G.W.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1050-1052
    • /
    • 2000
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system (3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation. a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

Experimental Study on the Cooling seasonal Performance Factor of Room Air-conditioner (에어컨의 냉방기간 에너지 효율 산출을 위한 실험적 연구)

  • Lee, H.W.;Moon, J.H.;Bae, Y.D.;Park, J.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.3
    • /
    • pp.204-216
    • /
    • 1992
  • In most cases, EER(Energy Efficiency Ratio) is available to present energy efficiency of air-conditioners. But, EER is not adapt to measure energy efficiency at actual life environment because it is based on fixed temperature and humidity contditions. To overcome this disadvantage, there is need to introduce SEER(Seasonal Energy Efficiency Ratio) established at time varient temperature and humidity conditions. In this paper, SEER measurement method and conditions based on actual life environment of the country is introduced, and discussed SEER value about two air-conditioner type, that is, non inverter air-conditioner and inverter air-conditioner. As a result of, inverter air-conditioner was superior to non inverter air-conditioner at cooling seasonal energy efficiency.

  • PDF

Analysis of Oil Supply System of a R134a Rotary Vane Compressor (R134a 로타리 베인 압축기 급유 계통 해석)

  • Kim, Ho-Young;Kim, Hyun-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.113-118
    • /
    • 2008
  • For a R134a rotary vane compressor used for car air conditioners, characteristics of gas compression and oil supply have been studied. The compressor model under investigation has the low volume ratio of suction to discharge volumes so that there occur flow reversal from discharge port to compression chamber as the leading vane passes over the discharge port. As a result, the volumetric and adiabatic efficiencies turn out to be relatively low compared to other types of displacement compressors. Oil supply mechanism has been comprehended for mathematical modeling and oil flow rate has been calculated for the individual oil passages. This study on the gas compression and oil supply of a rotary vane compressor can be applied to a future design practice on a similar type of compressor.

  • PDF

Development of the Dynamic Simulation Program for the Multi-Inverter Heat Pump Air-Conditioner (멀티 인버터 히트펌프의 동특성 해석 프로그램의 개발)

  • ;;小山繁
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1079-1088
    • /
    • 2001
  • A dynamic simulation model was developed to analyse the transient characteristics of a multi-inverter heat pump. The programs included a basic air conditioning system such as a evaporator, condenser, compressor, linear electronic expansion valve (LEV) and by-pass circuit. The theoretical model was derived from mass conservation and energy conservation equations to predict the performance of the multi-inverter heat pump at various operating conditions. Calculated results were compared with the values obtained from the experiments at different operation frequencies of compressor, area of the LEV and configuration of indoor units operation. The results of the simulation model showed a good agreement with the experimental ones, so that the model could be used as an efficient tool for thermodynamic design and control factor design of air-conditioners.

  • PDF

Experimental study on the hydrophilic performance of pre-coated aluminum foil (알루미늄 호일의 친수코팅 성능 개선에 관한 실험적 연구)

  • 김영생;길용현;박환영;윤백;김자수소;김병열
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.725-732
    • /
    • 1999
  • It is usual to use hydrophilic-coated aluminum foil for evaporator fin of air-conditioners to reduce air flow resistance caused by the water droplets condensed on the fin surface. The major effect of a hydrophilic coating is to reduce the contact angle of the condensate and prevent bridging of the condensate between the adjacent fins. The performance of hydrophilic coating generally tends to be degraded as it is used since the coating material is washed down by the condensate. In the present work, several types of hydrophilic coatings were evaluated in terms of durability of hydrophilicity, corrosion resistance and heat resistance. Results showed that an improved hydrophilic coating of resin type presented superb qualify in terms of durability and corrosion resistance while having almost the same level of qualify in heat resistance compared with the others.

  • PDF

Thermal Performance Analysis of Circular Coil Type Internal Heat Exchanger for Transcritical $CO_2$ System (천임계 $CO_2$ 시스템용 코일형 내부 열교환기의 열성능 해석)

  • 박병규;김근오;김무근
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.7
    • /
    • pp.531-542
    • /
    • 2002
  • Transcritical$CO_2$ systems are under consideration for use as residential/mobile air conditioners. In these systems, an internal heat exchanger is usually adopted to improve both capacity and/or COP of the $CO_2$ system in lower operating pressure range of gas cooler. A program has been developed to analyse the performance of internal heat exchangers using the section-by-section method. The internal heat exchanger of coaxial configuration is first analyzed and fairly good agreements with the data are obtained, And then the internal heat exchanger of multiple circular coil configuration has been investigated. The results obtained from the parametric study provide the guidelines for the initial design and manufacturing concepts of the internal heat exchanger in transcritical $CO_2$ system. Further studies are necessary to develop the heat transfer correlations of carbon dioxide in the tubes to obtain more accurate results.

A Study on the Economic Analysis of Cooling-Heating System Using Ground Source Heat in a public library (공공도서관에 지열시스템 적용시 경제성에 관한 연구)

  • Choi, Chang-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.1
    • /
    • pp.56-66
    • /
    • 2012
  • This study evaluated the economic benefits by comparing Cooling-Heating System with the existing system in the public library. The building's annual energy consumption was measured by adding the figures of the absorber chillers, the air conditioners and heaters in the building. The total amount of annual energy consumption was 143.51RT in air-conditioning and 83.66RT in heating. So, We made the capacity of geothermal heat pumps three 50RTs in order to check up this system. In order to estimate each construction and equipment cost and to evaluate economical efficiency, LCC(Life Cycle Cost) method was used and the service life of the building was sixty years. The result of analysis was that the geothermal cooling-heating system was more efficient than the existing system in public library.

A Study on the Development of Forming Process for a Compressor Shell Body (압축기용 쉘바디의 성형공정 개발에 관한 연구)

  • Kim, Min-Jeong;Oh, Won-Jung;Shin, Dong-Cho;Lee, Choon-Man
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.8
    • /
    • pp.635-640
    • /
    • 2016
  • The shell body is the main exterior part of a compressor, and production of shell bodies has increased along with a growing demand for air conditioners, refrigerators, air compressors, and so on. Cracks frequently occur in the process of welding a shell body. In this study, a deep drawing process for creating a shell body from a blank is developed. The technique consists of a four-step deep drawing and a two-step trimming process. Analysis is performed by DEFORM software to examine the safety of the deep drawing and trimming processes. The deep drawing process for the shell body developed in this study would have wide application in many industrial fields.