• Title/Summary/Keyword: Condition check

Search Result 804, Processing Time 0.027 seconds

Performance Evaluation Method of a Swing Check Valve (스윙형 역지밸브 성능 평가 방법)

  • Kim, Y.S.;Lee, D.W.;Kim, D.W.;Park, S.K.;Hong, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.881-886
    • /
    • 2003
  • In spite of its simple design, structure and operating mechanism, swing check valves are one of the critical components which adversely affect the safety of the nuclear power plants if they fail to function properly. Therefore, it is important to evaluate the performance condition of the swing check valves in safety-related systems. The performance characteristics of swing check valves include opening characteristics, the minimum required flow velocity, the pressure drop at design flow, the disc stability, and the effect of the upstream disturbances. Among factors to identify the performance of a swing check valve, a method to evaluate the opening characteristics and the minimum required flow velocity, which guarantees to fully open the disc and hold the disc without motion, are presented to determine the operating region of the swing check valve, such as stable, tapping, or oscillation. Based on the determined operating region and opening characteristics, the simple methods of wear and fatigue analyses of the specific parts of the valve are also described.

  • PDF

A Study on the Marking Efficiency of Check-Patterned Shirts (체크무늬 Shirts의 Marking 효율성에 관한 연구)

  • Hong, Eun-Hee;Suh, Mi-A
    • The Research Journal of the Costume Culture
    • /
    • v.17 no.5
    • /
    • pp.746-757
    • /
    • 2009
  • This study is focused on the elucidation of efficient and correct marking methods by comparing and analyzing marker efficiency depending on the marking job condition such as interval of checking-pattern, width of materials, and marker orientation using man's shirts. To compare the marking efficiency of shirts, plain and check-patterned materials with the intervals of $1.5{\times}1.5cm$, $3{\times}3cm$, and $5{\times}5cm$ were selected. First, in the comparison of marking efficiency depending on materials width, the highest efficiency was obtained with nap-either-way position of 150cm, plain materials and lowest efficiency with nap-one-way position of 150cm, $5{\times}5cm$ check-pattern materials. Regardless of the direction of marker position, the marking efficiency of 150cm width was higher than 110cm width in the plain, $1.5{\times}1.5cm$ and $3{\times}3cm$ check-pattern interval, but the marking efficiency of 110cm width was higher than 150cm width in the $1.5{\times}1.5cm$ check-pattern interval. Second, in the comparison of marking efficiency depending on the direction of marker position, regardless of check-pattern interval and material width, the highest efficiency was obtained with nap-either-way position. And nap-up-and-down and nap-one-way follows next. Third, in the comparison of marking efficiency depending on check-pattern interval, the efficiency of plain materials was higher than those of check-patterned materials. And increasing the intervals decreased marking efficiency and vice versa. So the lowest efficiency was obtained with $5{\times}5cm$ check patterned materials.

  • PDF

A Study on the Investigation Technique for Deterioration State of Window·Door and Tile of Apartment Houses (공동주택 창호 및 타일의 열화상태 조사기법에 관한 연구)

  • Lee, Jung-Hun;Bae, Kee-Sun;Lee, Seong-Bok;Oh, Sang-Keun;Choi, Soo-Kyung;Seo, Chi-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.27-30
    • /
    • 2011
  • Analysis data of basics which are used for LCC(Life Cycle Cost) analysis of buildings and maintenance plan, are demanded to secure according as replacement cycle of repairs of apartment houses has come. However, investigation techniques and systems for investigating condition of deterioration of apartment houses, have not been made yet in Korea. For this reason, this study was wanted to make investigation techniques and systems, so the process for maintenance of apartment houses was researched and the required quality and deterioration factors of interior/exterior materials were investigated. As a result Check-List for investigating condition of deterioration, was made. if this is used during a nonscheduled, a routine, a regular and a urgency check, the methodical investigation will be achieved. Furthermore, if this is used for maintenance of apartment houses, it will be helped to select the repair cycle and the long-term repair plan.

  • PDF

IMPROVING HABITAT OF FORMOSAN LANDLOCKED SALMON BY DAM REMOVAL

  • Yeh, Chao-Hsien;Lien, Hui-Pang
    • Water Engineering Research
    • /
    • v.6 no.4
    • /
    • pp.149-159
    • /
    • 2005
  • With increasing recognition on conservation of endangered species in Taiwan, one of the major conservation projects is the habitat restoration of Formosan Landlocked Salmon which is major threatened by check dams in the channel for their blockading pathway to upstream and causing the problems of population isolation and close-blood mating. By creating an opening in the central dam body appropriately, partial removal dams can provide pathway for the fish for the better upstream channel habitat. Four check dams at Gau-Shan Creek were remodeled between April of 1999 and September of 2002 with information supported from model experiments under certain hydraulic condition of field environment. Based on the follow-up investigation, the channel morphology of observation sections is in stable condition and the total number of Formosan Landlocked Salmon in this creek increased promptly at the reach containing partial-removed dams.

  • PDF

Study on the Real-Time Leak Monitoring Technique for Power Plant Valves (발전용 밸브누설 실시간 감시기술 연구)

  • Lee, S.G.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.39-44
    • /
    • 2007
  • The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

A study on Fire Hazard of Electric Radiant Heating Systems with Thermal Storage Using Off-peak Electricity (심야용 축열식 전기온풍기의 화재 위험성에 관한 연구)

  • Park, Min-Yeong;Mun, Yong-Su
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.8 no.1
    • /
    • pp.41-48
    • /
    • 2006
  • The purpose of this study is to identify the fire danger of the electric radiant heating system and check the way how to use it and the problems that could be possible through a actual case. We carry out an experiment to identify the possibility of the fire in the similar condition of the actual fire case. The results of this study are as follows. It is a possible condition to fire if the air blast of the electric radiant heating system is blocked by some combustible materials such as plastic bags continuously. A temperature sensor and a residual current device are necessary to disconnect the power source. It is also necessary to attach a notice in front of the electric radiant hearing system that shows users the fire danger to forbid the possible fire. Fires could be happened by internal defects of the electronic products. However, we can also find many external reasons to happen fires. Therefore, we need to check all reasons to make fires in the scene of a fire.

  • PDF

Normal Mode Vibrations of a Beam with a Nonlinear Boundary Condition (비선형 경계조건을 가진 보의 정규모드진동)

  • 김현기;이원경
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.392-398
    • /
    • 1998
  • In order to check the validity of nonlinear normal modes of continuous, systems by means of the energy-based formulation, we consider a beam with a nonlinear boundary condition. The initial and boundary e c6nsl of a linear partial differential equation and a nonlinear boundary condition is reduced to a linear boundary value problem consisting of an 8th order ordinary differential equations and linear boundary conditions. After obtaining the asymptotic solution corresponding to each normal mode, we compare this with numerical results by the finite element method.

  • PDF

Interference Check for Reactor In-Core Instrumentation Guide Tube Routing (원자로 노내계측기 안내관의 배열을 위한 간섭검증)

  • Cho, Duk-Sang
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.3 no.3
    • /
    • pp.201-207
    • /
    • 2000
  • In this study, methodologies for checking the interference between in-core instrumentation (ICI) guide tubes for routing of ICI guide tubes in the reactor coolant system of typical Pressurized Water Reactor under cold and normal operation (NOP) conditions are presented. The closest points of ICI guide tubes under cold condition are calculated by using minimize technique and are used as data for NOP analysis. Movements of ICI guide tubes under NOP condition are performed by the commercial computer code, SUPERPIPE.

  • PDF

REMARKS ON METALLIC MAPS BETWEEN METALLIC RIEMANNIAN MANIFOLDS AND CONSTANCY OF CERTAIN MAPS

  • Akyol, Mehmet Akif
    • Honam Mathematical Journal
    • /
    • v.41 no.2
    • /
    • pp.343-356
    • /
    • 2019
  • In this paper, we introduce metallic maps between metallic Riemannian manifolds, provide an example and obtain certain conditions for such maps to be totally geodesic. We also give a sufficient condition for a map between metallic Riemannian manifolds to be harmonic map. Then we investigate the constancy of certain maps between metallic Riemannian manifolds and various manifolds by imposing the holomorphic-like condition. Moreover, we check the reverse case and show that some such maps are constant if there is a condition for this.