• 제목/요약/키워드: Condenser pressure

검색결과 249건 처리시간 0.025초

스펀지 볼을 이용한 원전용 복수기 튜브 세정 시스템 개발 (Development on Cleaning System of Condenser for Nuclear Power Plant by Using Sponge Ball)

  • 이중섭;이치우
    • 한국기계가공학회지
    • /
    • 제14권6호
    • /
    • pp.21-26
    • /
    • 2015
  • This study presents a development of the cleaning system in a nuclear power plant condenser. The tube cleaning system is very important equipment in a power plant condenser. Specially, removal of the fouling is a key process in the condenser tube. The objective of this study is development of a ball collector system for cleaning a condenser by using a sponge ball. This study uses CFD in order to optimize design of the ball strainer screen. Through the CFD, the implication of the ball strainer screen for static pressure distribution is examined. Results of research, this study have developed a 1/5 scale model for application to the power plant and developed a performance test equipment.

가역원리에 의한 1인치 표준 컨덴서 마이크로폰의 정밀교정 (Precision Calibration of 1-Inch Standard Condenser Microphone by Reciprocity Technique)

  • 서상준;조문재
    • 한국음향학회지
    • /
    • 제8권5호
    • /
    • pp.23-32
    • /
    • 1989
  • 표준 컨덴서 마이크로폰의 정밀 교정은 가역원리를 이용한 가역교정에 의해 이루어진다. 본 연구에서는 가역교정 중에서도 결합기를 이용하는 음압교정(pressure calibration)을 수행하여 세 개의 1인치 컨덴서 마이크로폰의 음압감도를 결정하였다. 마이크로본의 음압감도를 정밀하게 결정하기 위해서는 전압이나 결합기의 치수를 정밀하게 측정하여야 하며 결합기의 구조상 발생하는 제반 현상들에 대한 보정을 정확하게 해 주어야 한다. 이와같은 사항들을 정화하게 고려할 경우 가역교정에 의한 교정정밀도는 저주파와 중간 주파수 영역에서 0.05dB이며 10kHz 이상에서는 0.ldB가 된다.

  • PDF

자동차용 에어컨의 고밀도 응축기(SCC)에서 배플의 위치 변화에 따른 성능향상에 관한 연구 (Effects of Baffle Location on the Performance of a Super Compact Condenser in an Automotive Air Conditioning System)

  • 이명재;박복춘;백병준;염동석;한창섭
    • 한국자동차공학회논문집
    • /
    • 제5권6호
    • /
    • pp.128-140
    • /
    • 1997
  • A new super compact condenser(SCC), which has been developed recently is especially suitable for an alternative refrigerant HFC-134a due to its high performance and compactness. The SCC is composed of two pipe headers, baffles, narrow multi-rectangular channels, and louvered fin arrays. Alternating inlet and outlet by the inserted baffles in pipe headers guide refrigerant to and from the narrow multi-rectangular channels. Since the flow rate and its lengh are changed depending on the number and location of baffles, the corresponding pressure drop and heat transfer rate are changed. The present study aims to theoretically and experimentally investigate the effects of baffle location and its number on the pressure drop and thermal performance of the SCC with 40 multi-rectangular channels. The results show that the present method provides an acceptable prediction of pressure drop and heat transfer rate for a 4 pass SCC. However, the model significantly under predicts the performance of a 3 pass SCC, which may be attributed to the phase separation of refrigerant flowing through header pipes. Pressure drop is more signifi- cantly influenced than heat transfer rate by the baffle location.

  • PDF

자동차용 리시버/건조기 일체형 응축기의 성능해석 (Performance Analysis of Integral Receiver/Dryer Condenser for Automobile)

  • 원성필
    • 설비공학논문집
    • /
    • 제19권3호
    • /
    • pp.245-252
    • /
    • 2007
  • The important problems from the point of view of preventing global warming are to save the power consumption of automotive air-conditioning systems and reduce the refrigerant amount filled. To achieve such requirements, integral receiver/dryer (R/D) condensers were developed recently. Typical integral R/D condensers have extra headers that play the role of R/D. Except an extra header and somewhat complex tube array resulting from the extra header, the most integral R/D condensers have almost the same specification that tube has multi channels, fin has louvers, flow in tube is parallel, etc. When integral condensers are applied, it is known that the refrigerating effect increases, resulting from the increase of subcooling degree in condenser, and the refrigerant amount used saves. In spite of several merits, integral condensers have not been applied a lot. That is why there is an uncertainty in performance, using integral condensers. The objective of this study is to theoretically optimize the tube array in an integral R/D condenser that is really being applied to some vehicles. The tube array has a great effect on the performance of the integral condenser as well as common ones. Through computer simulation, we could see that the tube array, 14-6-3-5-3-4, in the same condenser was the best, comparing heat release rate, pressure drop, etc. to the real array, 17-5-3-3-2-5. It should be noted that the optimization is based on the condenser performance only.

Impacts of Fouling and Cleaning on the Performance of Plate Fin and Spine Fin Heat Exchangers

  • Pak, Bock-Choon;Baek, Byung-Joon;Eckhard A. Groll
    • Journal of Mechanical Science and Technology
    • /
    • 제17권11호
    • /
    • pp.1801-1811
    • /
    • 2003
  • An experimental study was conducted to investigate the effects of air-side fouling and cleaning on the performances of various condenser coils used in unitary air-conditioning systems. A total of six condenser coils with different fin geometry and row number were tested. Performance tests were performed at three different conditions: clean-as-received, after fouling, and after cleaning. In all cases, it was observed that the fouling was mostly confined to the frontal face of the heat exchanger as reported in the previous investigations. The amount of deposited dust was more dependent on fin geometry for the single-row heat exchangers than for the double-row heat exchangers. The predominant effect of fouling was to cause a more significant increase in air-side pressure drop than a degradation in heat transfer performance. For the single-row heat exchangers, the pressure drop increased by 28 to 31%, while the heat transfer performance decreased by 7 to 12% at the standard air face velocity of 1.53 m/s depending on fin shape. For the double-row heat exchangers, the pressure drop increased by 22 to 37%, and heat transfer performance decreased by only 4-5% at the same air face velocity. Once the contaminated coils were cleaned according to the given cleaning procedure the original performance of the heat exchangers could almost be recovered completely. The pressure drop could be restored within 1 to 7% and the heat transfer performance could be recovered to within 1 to 5% of the originally clean heat exchangers. Therefore, it is concluded that a periodic application of the specified cleaning technique will be effective in maintaining the thermal performance of the condenser coils.

냉수공장에서 열전달을 고려한 응축기와 증발기의 물 압력강하 특성 (Characteristics of the Water Pressure Drop Considering Heat Transfer in the Evaporator and Condenser of a Water Chiller)

  • ;이근식
    • 대한기계학회논문집B
    • /
    • 제35권12호
    • /
    • pp.1293-1300
    • /
    • 2011
  • 물 냉각기의 응축기와 증발기의 형상(길이, 관 직경, 관수, 통로 수)은 설비비용에 관련된 열전달 면적과 운전비용에 관련된 압력강하와의 조화로 결정될 수 있다. 물 냉각기 (냉동사이클)의 쉘-관 형상의 열교환기(응축기와 증발기)의 관 내부로 물이 통과할 때, 주어진 냉각부하와 요구조건을 만족하면서, 물 압력강하가 작은 설계조건에 초점을 맞추었다. 상업용 강화튜브의 사용과 상용 소프트웨어를 사용한 해석결과의 검증으로 실용성과 신뢰성 확보를 도모하였다. 해석결과, 관 통로 수를 적게, 관 직경을 크게, 관 수를 많게 선정하면, 관 길이를 짧게 하므로 물측 압력강하를 줄일 수 있었다. 그러나, 관수가 특정값보다 많을 때는 오히려 작은 관 직경을 사용하는 것이, 내부열저항의 감소로 인한 단위 길이 당 총열저항 감소 때문에, 관 길이를 짧게 하여 설비비용을 줄일 수 있었다.

선박용 해수 열교환방식 A/C 응축기의 부식원인 (Study on the corrosion of A/C condenser in the ship)

  • 백상민;양정현;김기준;문경만;이명훈
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.283-284
    • /
    • 2006
  • The ship performs heat exchange using seawater to keep main engine and auxiliary machinery at optimum temperature. In heat exchanger, refrigerant located outside of copper tube is cooled by seawater flowing through inside of copper tube. On the other hand, seawater erosion and corrosion nay occasionally cause the corrosion of the copper tube in A/C(Air Conditioner) condenser. This corrosion of copper tube makes seawater and refrigerant mixed, seriously damaging A/C system. In this study, accordingly, the exact ive mechanism of the corrosion on the condenser entailing serious problems occasional is investigated through the electrochemical polarization experiments on the condenser's component materials. According to the experiments, the corrosive procedures on the copper tube was verified by the fact that passive film of the copper tube surface which is destroyed by the pressure of sucked seawater, is damaged by the corrosive ingredients in the seawater.

  • PDF

대형 에어컨에 적용된 PF열교환기의 성능평가 (Performance evaluation of PF-condenser adapted to Large Size air-conditioner)

  • 조진표;최영훈;김재호;김내현;김정오
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.1-6
    • /
    • 2000
  • In this study, We evaluated the Performance of PFC and the system performance of large size air-conditioner applying to outdoor condenser. PFC can meet the same cooling capacity in 40.42% of volume to fin-tube condenser. Although the fin-tube condenser requires 3600g of refrigerant charging, PFC requires 1700g, 1800g, 1900g, 2000g refrigerant charging for each 2.0mm, 2.5mm, 3.0mm and 3.5mm fin pitches. Difference of condensing and evaporation pressure is the biggest point 2.0mm fin pitch and the smallest point 2.5mm fin pitch.

  • PDF

응축기 배열회수에 의한 흡수식 냉동기의 고효율화에 관한 연구 (A Study on the COP Improvement of Absorption Chillers by Recovering Heat from the Condenser)

  • 박찬우
    • 설비공학논문집
    • /
    • 제18권9호
    • /
    • pp.738-744
    • /
    • 2006
  • In order to utilize the condensation heat of refrigerants in condenser on the absorption chiller system, the solution cooled condenser (SCC) was proposed using the weak solution of absorber as a cooling medium. The increase of COP with the increase of UA of the solution cooled condenser was approximately 0.009 in maximum with single effect one, and is about maximum 0.008 in occasion of double effect one with series flow compared to that without. In the case of heat exchanger, effectiveness is about 0.85, it's increments are 0.008 and 0.0072, respectively. And solution cooled condenser is more effective device in the single effect absorption system than double effect system for the principle of operation. On the other hand, as the solution split ratio increases when the value of UA is fixed, COP is increased and as the solution split ratio increases when the value of UA is fixed, COP is increased. If the flow rate of cooling water or the value of UA is reduced in order to increases the heat recovery of solution cooled condenser, heat recovery of solution cooled condenser is increased a little but COP is decreased as the system pressure is increased.

볼 여과기 스크린 모듈의 단면 폐쇄효과에 관한 수치해석적 연구 (Numerical Analysis of Ball Strainer Screen Module Blockage Effects)

  • 정경철;이해수;이치우
    • 동력기계공학회지
    • /
    • 제19권1호
    • /
    • pp.83-89
    • /
    • 2015
  • A ball strainer screen module, which is used for a condenser tube cleaning system, is a critical mechanical component for maintaining condenser cleanliness. Despite of this importance, not many research have been focused on this module because of its relatively low usage. Employing CFD, this study examines the implication of fluid velocity change and blockage ratio on the ball strainer screen velocity and the static pressure distribution. Through this study, the impact of blockage in the space between ball strainer screen modules is verified. Also, it is found that the ranges of non-dimensional velocity distribution and static pressure distribution decrease as blockage ratio becomes smaller.