• Title/Summary/Keyword: Concrete repair

Search Result 808, Processing Time 0.024 seconds

Bonding Properties of Steel-reinforced Polymer Cement Mortar Evaluated by Pull-off Test and FEM Modeling (폴리머 시멘트 모르타르의 철근부착력 평가를 위한 인발실험과 모델링)

  • Park, Dong-Cheon;Yoneda, Nobutosi;Cho, Bong-Suk
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.3
    • /
    • pp.216-222
    • /
    • 2014
  • Chloride attack to reinforced concrete structures located in seaside can cause a serious problem of durability and maintenance during the service life. Corrosion of reinforced steel bars in concrete decreases the bond strength and finally causes the detachment of concrete cover. Polymer cement mortar is usually adopted to repair the deteriorated RC structures because of its strong bonding property. The recovered load-carrying capacity after the repair was simulated by non-linear FEM analysis. The properties of concrete, repairing materials, bonding materials and reinforced bar were used as input data. Four types of redispersible polymer powders were used as components of polymer cement mortar. Pull-off tests were carried out to examine the bond properties such as rigidity and strength. Effects of a corrosion inhibitor and the loss of reinforced bars due to the corrosion were also considered in this study. FEM modeling and analysis were conducted to propose the universal model. Physical bonding in the relationship between repair materials and steel reinforced bar is more dominant than chemical bonding.

The Research on the Ladder System for Corrosion Monitoring (부식 모니터링을 위한 Ladder system에 관한 연구)

  • 송호진;문홍식;이상국;정영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.671-676
    • /
    • 2001
  • Reinforcement corrosion is major problem for those who own and maintain reinforced concrete structures exposed to chlorides. It is well understood that the form of corrosion is more problematic than corrosion found elsewhere, Because concrete has no apparent signs that there is anything amiss until the process of deterioration is relatively far advanced. The objective of this research is to develop the ladder system which monitors the corrosion of reinforcing steels in concrete. This system can be used to assess the corrosion condition and corrosion rate of steel in concrete, which can give timely repair and strengthening of steel in concrete structure.

  • PDF

Test for Concrete Crack Depth Measurement Using Ultrasonic Pulsevelocity Technique (초음파 속도를 이용한 콘크리트의 균열깊이 측정)

  • 이장화;김성욱;송영철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1991.04a
    • /
    • pp.117-120
    • /
    • 1991
  • Cracks of concrete structure must be analyzed and estimated synthetically in order to have a maintenance and to insure the safety and the durability of structure. Concrete cracks have to be surveyed with respect to depth, width, shape and direction etc, but crack depth among these items is not measured easily. Occasionally, it needs to measure the crack depth of concrete structure for the purpose of evaulating the safe capacity and the necessity of repair. Therefore, this research is performed to verify the applicability and the accuracy of Ultra-sonic Pulse Velocity Technique(Tester), in non-destructive testing methods of concrete crack depth.

  • PDF

Structural behavior of R/C Slabs Strengthened with Steel Plate, Carbon fiber sheets, and Carbon Fiber Laminate. (강판, 탄소섬유쉬트, 탄소섬유판으로 휨보강된 철근콘크리트 슬래브의 구조적 거동)

  • Lee, Young-Jea;Moon, Heui-Jeung;Lee, Kyung-Un;Chung, Lan;Jung, Sang-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.601-606
    • /
    • 1998
  • In recent years, strengthening by steel plate, carbon fiber sheets, and carbon fiber laminate in spotlighted in order to repair and rehabilitation of R/C slabs. In this study, 3 method of rehabilitation are analyzed from the tests. Test parameters are the width of cracks, the method of repair and rehabilitation, the magnitude of pre-load. Deflection, failure load, strains of reinforcing bar, strains of sheet and plates are measured during tests. The failure mode and separption load analyzed from these measured data.

  • PDF

Repair and Strengthening Method Using Near Surface Mounted FRP Rods and Overlay (FRP Rod를 이용한 표면매립 및 단면 확대 복합 보수$\cdot$보강 공법)

  • Hwang Gum-sic;Park Chin-ki;Won Jong-pil
    • Composites Research
    • /
    • v.18 no.4
    • /
    • pp.66-74
    • /
    • 2005
  • This paper reports new repair and strengthening mathod using improved material. This mathod have two type according to covering thickness of reinforcement. One type is near surface mounted FRP rod. Anther type is overay. Fiber Reinforced Plastic (FRP) materials has become very popular in recent years. FRP material used to rehabilitate many types of structures with superior characteristics such as high strength and stiffness and corrosion resistance. This strengthening mathod were used FRP rod which have better bond and shear strangth than current FRP rod. Development of FRP rod due to 3-D winding system. In addition, Ductile hybrid FRP has a certain plastic deformation and an elongation greater than 3% at maximum load is usually required for steel reinforcement in concrete structures. Moerover this mathod can be effective repair of base concrete by sprayed polymer mortar.

A Fundamental Study in order to Utilize Waste Glasses Powder as Admixtures of Repair Mortar (폐유리 미분말을 보수모르타르의 혼합재료로 활용하기 위한 기초적 연구)

  • Choi, Yun-Wang;Jung, Moon-Yung;Kang, Hyun-Jin;Jung, Woo-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.341-344
    • /
    • 2006
  • The waste glasses among plenty of wastes put out lately is limited in recycling and reusing, and the phenomenon hasn't been improved quite much. And besides, the recycling rate shows the 70.1%, relatively low. These waste glasses is currently used for road pavement materials, interior and exterior decorating materials in architecture, road painting meterials, auxiliary lagging materials for heat-retaining, coldness-retaining and soundproofing, and glass bottles. 30% of waste glasses powder is, however, not reused pratically. Therefore, in this research, we operated some tests including flow of mortar mixed with waste glasses powder, setting time, rheology and compressive strength to utilize waste glasses powder put out in the precess of recycling for admixture for repair mortar. As a result, we've found out that we can utilize waste glasses powder for admixture for repair mortar.

  • PDF

Evaluation Repair Performance of Damaged R/C Beams due to Reinforcement Corrosion (철근 부식에 의해 단면이 손상된 R.C보의 보수성능평가)

  • Jeong, Sang-In;Hong, Geon-Ho;Shin, Yeong-Soo;Chung, Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.733-738
    • /
    • 2000
  • This paper was aimed to evaluate the structural performance of flexural members repaired by polymer cement and epoxy mortar at soffit. Main test variables were repair materials, ratio of reinforcement and additional reinforcing bars. Test results shows that the repaired beams could change flexural capacity by materials and additional reinforcing bars. In polymer cement, the section repaired can carry same load, cracking moment and the flexural stiffness of the monolithic beams with same size. In epoxy mortar, all data were greater than the shotcrete. However, note that epoxy mortar may conduct member into brittle failure mode.

  • PDF

Structural behavior of R/C Beam Strengthened with Steel Plate, Carbon Fiber Sheets, and Carbon Fiber Laminate. (강판, 탄소섬유쉬트, 탄소섬유판으로 휨보강된 천근콘크리트보의 구조적 거동)

  • Lee, Young-Jea;Moon, Heui-Jeung;Lee, Kyung-Un;Jung, Sang-Jin;Chung, Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.691-696
    • /
    • 1997
  • In recent years, stengthening of beam by steel plate, carbon fiber sheets, and carbon fiber laminate is spotlighted in order to repair and rehabilitation of R/C structures. In this study, 3 method of rehabilitation technic are analyzed from the tests. Test parameters are the width of cracks, the method of repair and rehabilitation, the magnitude of existing load. Deflection, failure load, strains of reinforcing bar, strains of sheet and plates are measured during tests. The failure mode and ultimate load are analyzed from these measured data. Test result shows that the width of cracks and the magnitude of existing load do not make any difference of ultimate flexural capacity.

  • PDF

An Evaluation on the Flexural Strength of Concrete Beams Repaired by Polymer Resin (폴리머계로 보수한 철근콘크리트 보의 휨성능 평가)

  • Kim, Byung-Guk;Shin, Young-Soo;Hong, Gi-Suop;Hong, Yung-Kyun;Choi, Oan-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.1 no.1
    • /
    • pp.107-112
    • /
    • 1997
  • A series of reinforced concrete beams was tested to evaluate the flexural performance of the repaired RC beams. The key parameters for this study were the size and location of the patch, and the repair materials, including polymer, polymer-cementitious and cementitious materials. The repaired specimens failed by a typical flexural mode with minor interfacial bond failure. Beams repaired with polymer, polymer-cementitious and cementitious materials recover 100%, 91%, and 97% of the flexural strength respectively, while beams with cement mortar lose approximately 30% of the strength. Compared with the pressure injection techniques the specimens repaired with patching techniques show low flexural strength, with significant interfacial bond failure. Location and size of the repaired part do not affect the recovering performance. Interfacial behavior between repair and strengthening materials is the major influencing factor for the composite structures.

  • PDF