• Title/Summary/Keyword: Concrete ground

Search Result 1,312, Processing Time 0.028 seconds

A Study on the Open Cut Restoration of Underground Cavity Using Concrete Mat (콘크리트매트를 이용한 개착식 지반공동 복구방법에 관한 연구)

  • Park, Jeong-Jun;Shin, Heesoo;Chung, Yoonseok;You, Seung-Kyong;Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.1
    • /
    • pp.55-65
    • /
    • 2019
  • This paper describes results of experimental and numerical analyses, in order to analyze a reinforcement effect of concrete mat on open cut restoration of underground cavity. The plate loading tests were conducted to evaluate a reinforcement effect of concrete mat, at reinforcement depths from the ground surface of 10 cm, 20 cm, and 30 cm. The result showed that the reduction ratio of stress (earth pressure) was about 60% at all reinforcement depth. The reinforcement effect considering ground surface settlement and reduction ratio of stress based on laboratory tests and numerical analysis was significant, at reinforcement depths from the ground surface of 10 cm~20 cm. LFWD test results showed that subgrade modulus was the largest when concrete mat was installed 20 cm below ground surface. Therefore, it is effective to reinforce concrete mat within 20 cm from the surface, when the underground cavity due to damage of underground utilities was formed in the height direction to the bottom of the pavement layer.

The relation Between Carbonation and Rebar Corrosion of Concrete Containing Ground Granulated Blast Furnace Slag (고로슬래그 미분말 혼입 콘크리트의 탄산화 및 철근부식의 관계)

  • 송형수;김형래;윤상천;지남용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1193-1198
    • /
    • 2001
  • The glass of Ground Granulated Blast Furnace Slag(GGBFS) was released by the hydroxyl ions during the hydration of the Portland cement. That results in relatively less $Ca(OH)_{2}$ in the concrete replaced with GGBFS than in ordinary portland cement concrete(OPCC). As the quantity of $Ca(OH)_{2}$ is decreased, the rate of carbonation in the concrete replaced GGBFS is faster than OPCC. Therefore, it has been misunderstood that the concrete replaced GGBFS has negative effect on the corrosion of steel by carbonation. Therefore, this study aimed at the relation between carbonation and rebar corrsion in the concrete with GGBFS, measuring air.water permeability, half cell, and corrosion rate by the depth of carbonation.

  • PDF

Estimation on the Sulfate Ion Diffusivity in Concrete by Accelerated Test (촉진시험에 의한 콘크리트중의 황산이온 확산계수 추정)

  • 문한영;김성수;김홍삼;이승태;최두선
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.425-428
    • /
    • 2000
  • When concrete structures are exposed to sulfate or marin environments, sulfate ions penetrated into concrete make it deteriorate. An accelerated test under potential difference method was performed to evaluate not only the sulfate ion diffusivity in ordinary portland cement and ground granulated blast-furnace slag cement concretes but the effect of slag replacement and water-cement ratio on the sulfate ions diffusivity. As the result of this study, we assumed the sulfate ion diffusivity was significantly related with total passed charge and initial current in concrete. Moreover sulfate ions penetration resistance of ordinary portland cement concrete was superior to that of ground granulated blast-furnace slag cement concrete.

  • PDF

Chloride Transport Rate in Blended Concrete Depending on Different Test Methods

  • Balamurugan, Loganathan;Kim, Sang-Hyo;Ann, Ki-Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.477-478
    • /
    • 2010
  • Concretes with binary blends of Portland cement, silica fume, fly ash and ground granulated blast furnace slag were produce to investigate their effects on compressive strength and chloride transport in rapid chloride permeability. Ten different mix of concrete with 0.45 water/binder were produced. Portland cement was replacedby: (i) 10%, 20%, 30% Fly ash (ii) 3%, 5%, 10% Silica Fume (iii) 20%, 40%, 60% GGBS. Compressive strength of concrete with the pozzolans is higher compared to that of the Portland cement concrete. The test results indicate the fly ash, silica fume, and ground granulated furnace slag greatly reduce the rapid chloride permeability of concrete. It was concluded that pozzolans are more effective to reduce chloride permeability of concrete.

  • PDF

Finite Element Analysis of the Effect of Chloride Ion on the Coastal Concrete Structure with Ground Granulated Blast Furnace Slag (고로슬래그 미분말을 사용한 해양콘크리트 구조물의 염분침투해석)

  • 여경윤;김은겸
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.945-950
    • /
    • 2000
  • Coastal concrete structure is harmed by physical and chemical action of sea water, impact load, meteorological effect and etc. especially, premature reinforcement corrosion in concrete exposed to sea water has an important problem. In this study, the behavior of chloride ions penetrated through the coastal concrete structure with ordinary portland cement or ground granulated blast furnace slag(GGBFS) was modeled. The physicochemical processes including the diffusion of chloride and the chemical reaction of chloride ion with calcium silicate hydrate and the other constituents of hardened cement paste such as$C_3A$ and $C_4AF$were analyzed by using the Finite Element Method. From analysis result, the corrosion of concrete structure with GGBFS begins 1.69~1.76 times later than that of concrete structure with ordinary portland cement.

An Experimental Study on the Application of the Maturity Method of Ground Granulated Blast Furnace Slag(GGBFS) Concrete to Calculate the Concrete Strength Correction Value(mSn) (고로슬래그 콘크리트의 구조체 보정강도(mSn) 산정을 위한 고로슬래그 혼입 구조체 콘크리트의 적산온도법 적용에 관한 실험적 연구)

  • Kim, Han-Sol;Jeong, Min-Gu;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.147-148
    • /
    • 2023
  • Recently, as blast furnace slag concrete has become widely used, managing the strength of concrete has become important. mSn is a method of correcting the difference in strength between standard cured specimens and concrete exposed to changes in temperature. In this study, the predicted strength based on the maturity of the central and outer parts of the blast furnace slag concrete structure is compared with the actual strength measured through coring. As a result, the actual strength difference between the center and the outer part of the concrete mixed with blast furnace slag was larger than the predicted strength difference.

  • PDF

An Experimental Study on the characteristics of Mortar Using the Ground Granulated Blast-Furnace Slag (고로서냉슬래그 미분말 사용 모르터의 물성에 관한 실험적 연구)

  • Park, Jung-Woo;Choi, Chang-Ki;Kim, Woo-Jae;Kim, Sung-Sik;Lim, Nam-Gi;Jung, Sang-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.107-112
    • /
    • 2000
  • In this study, when ground granulated blast-furnace slag is intermixed to mortar, the strength test, watertightness test, resistance to chemical attack of hardened mortar are compared and analyzed according to the replacement rate of slag. w/(cc+Bs) and Ground Granulated Blast-furnace slag. As a result, compared with ordinary portland cement, ground granulated blast-furnace slag intermixed concrete shows development of a long term strength, chemical-resistance, and excellent watertightness.

  • PDF

Shaking Table Test of a 1/5 Scale 3-Story Nonductile infilled Reinforced Concrete Frame (조적채움벽이 있는 1/5 축소 3층 비연성 철근콘크리트 골조의 진동대 실험)

  • 이한선;우성우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10a
    • /
    • pp.541-546
    • /
    • 1998
  • The objective of this research is to observe the actual response of low-rise nonseismic moment-resisting infilled reinforced concrete frame subjected to varied levels of earthquake ground motions. First of all, the reduction scale for the model was determined as 1 : 5 considering the capacity of the shaking table to be used. This model was, then, subjected to the shaking table motions simulating Taft N21E component earthquake ground motions, whose peak ground accelerations(PGA`s) were modified to 0.12g, 0.2g, 0.3g, and 0.4g. The global behavior and failure mode were observed. The lateral accelerations and displacements at each story and local deformations at the critical portions of structure were measured. Before and after each earthquake simulation test, free vibration tests were performed to find the changes in the natural period of the model.

  • PDF

An Experimental study on evaluation of reinforcing installation increasing the penetration depth about upset of concrete pole (콘크리트 전주의 근입깊이 증대를 위한 보강장치의 실험적 성능평가)

  • Shin, Dong-Geun;Yoon, Ki-Yong;Lee, Seung-Hyun;Lee, Gyu-Se;Kang, Young-Jong
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.71-74
    • /
    • 2008
  • For reinforcing the overturn of concrete pole instituted in slope ground and weak ground, in this paper, develop the reinforcing installation. The installation increase penetration depth and effect of increasing the penetration depth is verified by experimental paper of Lim, jong suk(2004). In this research, through the experiment of bending test using the reinforcing installation, evaluate the performance. In the result of experiment, concrete pole behave elastically in design load and all sample are safe up to failure load.

  • PDF

Fundamental periods of reinforced concrete building frames resting on sloping ground

  • De, Mithu;Sengupta, Piyali;Chakraborty, Subrata
    • Earthquakes and Structures
    • /
    • v.14 no.4
    • /
    • pp.305-312
    • /
    • 2018
  • Significant research efforts were undertaken to evaluate seismic performance of vertically irregular buildings on flat ground. However, there is scarcity of study on seismic performance of buildings on hill slopes. The present study attempts to investigate seismic behaviour of reinforced concrete irregular stepback building frames with different configurations on sloping ground. Based on extensive regression study of free vibration results of four hundred seventeen frames with varying ground slope, number of story and span number, a modification is proposed to the code based empirical fundamental time period estimation formula. The modification to the fundamental time period estimation formula is a simplified function of ground slope and a newly introduced equivalent height parameter to reflect the effect of stiffness and mass irregularity. The derived empirical formula is successfully validated with various combinations of slope and framing configurations of buildings. The correlation between the predicted and the actual time period obtained from the free vibration analysis results are in good agreement. The various statistical parameters e.g., the root mean square error, coefficient of determination, standard average error generally used for validation of such regression equations also ensure the prediction capability of the proposed empirical relation with reasonable accuracy.