• 제목/요약/키워드: Concrete Structures Repair

검색결과 365건 처리시간 0.021초

하천통과 지하구조물의 누수 보수 대책 (A Case Study on Repairing Work of Leakage of River-crossing Underground Structure)

  • 이종은;최석원;노현창
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.801-809
    • /
    • 2000
  • Until recently as a method of repairing leaking problem, generally urethane series were used for many structures as subway, box culvert etc. However the lacking of sufficient penetration capacity have made it difficult to repair such structures completely. Now, we could achieve enhanced quality of repairing work by using new material which was compounded of urethane series and cement series properly. This material can penetrate concrete structure efficiently and move interactively with the structure in case of the thermal expansion. Besides of this, we could prevent expecting leakage through several improvements on the aspects of design, materials and site implementation.

  • PDF

탄소섬유시트 보강보 휨해석에 영향을 미치는 섬유시트 인장강도 감소계수 평가 (Evaluation of CFS Tensile Strength Reduction Factor for Bending Analysis of RC Beams Strengthened with Carbon Fiber Sheets)

  • 윤진섭;이우철;정진환;김성도;조백순
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.359-362
    • /
    • 2003
  • Carbon fiber sheet is attractive due to its good tensile strength, resistance to corrosion, and low weight. The strengthening of concrete structures with externally bonded carbon fiber sheets is increasingly being used for repair and rehabilitation of existing structures. However CFS strengthened beams break down under the service loads. As rupture strain is not reached ultimate value, reduction of the tensile strength is recommended. This study evaluate CFS tensile strength reduction factor which is required to analyze bending moment.

  • PDF

지하 습윤 환경에서 콘크리트 구조물 균열 누수에 사용되는 주입형 보수재료의 부착 성능과 거동 대응 성능 평가의 상관성 분석 연구 (Comparative Analysis of Substrate Wet Surface Adhesion and Substrate Movement Response Performance Testing Methods for Injection Type Repair Materials Used in Leakage Cracks of Concrete Structure in Underground Environment)

  • 김수연;오규환;오상근
    • 대한건축학회논문집:구조계
    • /
    • 제34권9호
    • /
    • pp.19-26
    • /
    • 2018
  • The focus of this study was centered around 15 common injection type water leakage repair materials (3 different types for each; synthetic polymer, cementitious, acrylic, epoxy, urethane) used in concrete structures of Korea and analyzing their wet surface adhesion performance in accordance to the ISO TS 16774 Test Method for Repair Materials for Water-leakage Cracks in Underground Concrete Structures, Part 4: Test Method for Adhesion on Wet Concrete Surface, and the results of this study was taken to be place under a comparative analysis with the results of the preceeding study on response to substrate movement performance study. The results of this comparative study showed that other than 1 specimen of 1 type of the acrylic and 3 specimens of 1 type of the synthetic polymer type materials, all of the 93% of the specimens used in this study showed stable adhesion on wet substrate surface, and we were able to determine that materials that have proper response properties against substrate movement are highly flexible and have high adhesion properties, but their adhesion properties on wet substrate would change based on their viscosity.

염해를 입은 RC 구조물의 최적 보수주기 산정 기법에 관한 연구 (Estimation of Optimum Maintenance Cycle for the Chloride Damaged RC Structure)

  • 윤선영;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2010년도 춘계 학술논문 발표대회 1부
    • /
    • pp.235-236
    • /
    • 2010
  • Since many structures in the sea environment are damaged by chloride, appropriate repair strategy is required. Therefore in the paper, optimum period for the RC structure's repair is calculated with consideration of economic efficiency. Moreover, when the concrete members are repaired with the other material such as polymer mortar forr section restoration, their expected service life also calculated to predict more accurate repair period during the life span.

  • PDF

전기저항형 센서 및 전기화학적 방법을 이용한 철근콘크리트 구조물의 부식속도 측정 방법에 관한 연구 (Study on The Corrosion Rate Monitoring of Steel in Concrete Using Electric resistance Sensor and Electrochemical Methods.)

  • 조용범;김용철;장상엽;고영태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.1185-1192
    • /
    • 2001
  • This paper reviews available techniques for monitoring corrosion of steel in concrete. The need for early detection and diagnosis of corrosion related deterioration in reinforced structures is widely acknowledged. This is particularly important in reinforced concrete structures on account of the economic and social significance of the problem. The current generally used on-site procedure for corrosion monitoring of reinforced structures employs a method of half-cell surface potential measurements. While the technique has provided a useful means of delineating areas of high or low corrosion risk, there are difficulties in its use and interpretation when assessing rates of deterioration. Electrochemical techniques are by far the most suitable for corrosion monitoring purpose and meet most of the requirements. The aim of this paper is to describe the electric resistance sensor(ER sensor) and electrochemical techniques employed to monitor and estimate corrosion rates of reinforcement. Early detection and diagnosis of corrosion hazards allows preventive measures to be taken, hence the typically expensive repair of severely deteriorated structures can be avoided.

  • PDF

해양콘크리트구조물의 부식 방지를 위한 고내구성 재료의 성능비교 (Comparison of High-Durability Materials for Prevention of Corrosion in Marine Concrete Structures)

  • 이동근;김명유;양은익;이성태;한상훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.581-584
    • /
    • 2006
  • The durability of reinforced concrete structures is severely degraded by mainly corrosion due to seawater attack and chloride ion diffusion in concrete. The deterioration of durability causes high repair cost for maintenance of marine concrete structure. In this paper, high-durability materials for prevention of rebar corrosion are investigated to promote the durability in marine concrete structures. For these, the effect of the mineral materials addition(SF, FA and BFS), the modified steel(stainless and coating steel). and corrosion inhibitors are compared.

  • PDF

남해고속도로 섬진강교 내염보수공사 시공 (Repair of Seonjingang Bridge in Namhae Highway Route Deteriorated by Chloride Attack)

  • 한복규;지한상;정해문;안태송
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.355-358
    • /
    • 2005
  • Corrosion of reinforced concrete structures in marine environment is one of the most important mechanisms of deterioration. Under Korean highway bridge, the time for the steel reinforcement in the concrete to exhibit initial signs of corrosion is within three decades. Therefore, 'SUM JIN' highway bridge, located in a corrosive marine environment on the south of Korea, had been examined the current condition of the steel reinforcement corrosion in concrete by half-cell potentials, chloride contamination of concrete and so on. According to the tests, the protecting film around the reinforcement is deteriorated and corrosion activity developed in tidal zone. The purpose of this paper is to report the effects of 'SUM JIN' highway bridge damaged by chlodide attack and to present the results of repair of 'SUM JIN' highway concrete bridge in domestic marine environment.

  • PDF

초기 손상을 입은 비연성 철근콘크리트 골조의 FRP재킷으로 보수된 기둥의 수치해석모델 (Numerical Column Model for Damaged Non-ductile Reinforced Concrete Frame Repaired Using FRP Jacketing System)

  • 신지욱;전종수;김준희
    • 한국지진공학회논문집
    • /
    • 제22권5호
    • /
    • pp.291-298
    • /
    • 2018
  • Existing reinforced concrete building structures have seismic vulnerabilities under successive earthquakes (or mainshock-aftershock sequences) due to their inadequate column detailing, which leads to shear failure in the columns. To improve the shear capacity and ductility of the shear-critical columns, a fiber-reinforced polymer jacketing system has been widely used for seismic retrofit and repair. This study proposed a numerical modeling technique for damaged reinforced concrete columns repaired using the fiber-reinforced polymer jacketing system and validated the numerical responses with past experimental results. The column model well captured the experimental results in terms of lateral forces, stiffness, energy dissipation and failure modes. The proposed column modeling method enables to predict post-repair effects on structures initially damaged by mainshock.

Behavior of Laterally Damaged Prestressed Concrete Bridge Girders Repaired with CFRP Laminates Under Static and Fatigue Loading

  • ElSafty, Adel;Graeff, Matthew K.;Fallaha, Sam
    • International Journal of Concrete Structures and Materials
    • /
    • 제8권1호
    • /
    • pp.43-59
    • /
    • 2014
  • Many bridges are subject to lateral damage for their girders due to impact by over-height vehicles collision. In this study, the optimum configurations of carbon fiber reinforced polymers (CFRP) laminates were investigated to repair the laterally damaged prestressed concrete (PS) bridge girders. Experimental and analytical investigations were conducted to study the flexural behavior of 13 half-scale AASHTO type II PS girders under both static and fatigue loading. Lateral impact damage due to vehicle collision was simulated by sawing through the concrete of the bottom flange and slicing through one of the prestressing strands. The damaged concrete was repaired and CFRP systems (longitudinal soffit laminates and evenly spaced transverse U-wraps) were applied to restore the original flexural capacity and mitigate debonding of soffit CFRP longitudinal laminates. In addition to the static load tests for ten girders, three more girders were tested under fatigue loading cycles to investigate the behavior under simulated traffic conditions. Measurements of the applied load, the deflection at five different locations, strains along the cross-section height at mid-span, and multiple strains longitudinally along the bottom soffit were recorded. The study investigated and recommended the proper CFRP repair design in terms of the CFRP longitudinal layers and U-wrapping spacing to obtain flexural capacity improvement and desired failure modes for the repaired girders. Test results showed that with proper detailing, CFRP systems can be designed to restore the lost flexural capacity, sustain the fatigue load cycles, and maintain the desired failure mode.