• 제목/요약/키워드: Concrete Filled Tubular Column

검색결과 168건 처리시간 0.028초

종리브로 보강한 콘크리트충전원형강관기둥-H형강보 접합부의 구조적 거동에 관한 연구 (The Structural Behavior of CFCT Column to H-Beam Connections With Longitudinal Rib of Column at Joint)

  • 강현식;문태섭
    • 한국강구조학회 논문집
    • /
    • 제10권2호통권35호
    • /
    • pp.291-301
    • /
    • 1998
  • 종리브로 보강된 충전형 원형강관에 H형강보를 사용한 접합부 모델실험 결과와 항복선이론 및 수치해석을 이용하여 접합부 국부내력의 추정을 위한 기초 자료를 제시하고 궁극적으로는 원형강관 접합부의 보강법을 연구하여 다이아프램이 없는 콘크리트 충전강관 기둥-H형강보 접합부의 개발을 위한 기초자료를 제시하고자 한다.

  • PDF

Modeling of composite MRFs with CFT columns and WF beams

  • Herrera, Ricardo A.;Muhummud, Teerawut;Ricles, James M.;Sause, Richard
    • Steel and Composite Structures
    • /
    • 제43권3호
    • /
    • pp.327-340
    • /
    • 2022
  • A vast amount of experimental and analytical research has been conducted related to the seismic behavior and performance of concrete filled steel tubular (CFT) columns. This research has resulted in a wealth of information on the component behavior. However, analytical and experimental data for structural systems with CFT columns is limited, and the well-known behavior of steel or concrete structures is assumed valid for designing these systems. This paper presents the development of an analytical model for nonlinear analysis of composite moment resisting frame (CFT-MRF) systems with CFT columns and steel wide-flange (WF) beams under seismic loading. The model integrates component models for steel WF beams, CFT columns, connections between CFT columns and WF beams, and CFT panel zones. These component models account for nonlinear behavior due to steel yielding and local buckling in the beams and columns, concrete cracking and crushing in the columns, and yielding of panel zones and connections. Component tests were used to validate the component models. The model for a CFT-MRF considers second order geometric effects from the gravity load bearing system using a lean-on column. The experimental results from the testing of a four-story CFT-MRF test structure are used as a benchmark to validate the modeling procedure. An analytical model of the test structure was created using the modeling procedure and imposed-displacement analyses were used to reproduce the tests with the analytical model of the test structure. Good agreement was found at the global and local level. The model reproduced reasonably well the story shear-story drift response as well as the column, beam and connection moment-rotation response, but overpredicted the inelastic deformation of the panel zone.

용접조립 각형 CFT 기둥-보 외다이아프램 접합부의 구조 거동 (Structural Behavior of Welded Built-up Square CFT Column to Beam Connections with External Diaphragm)

  • 이성희;김영호;최성모
    • 한국강구조학회 논문집
    • /
    • 제28권2호
    • /
    • pp.75-83
    • /
    • 2016
  • 기존 콘크리트충전 각형강관(CFT) 구조에 사용하는 각형강관은 4개의 판을 용접하여 제작하는 박스칼럼이 일반적이다. 그러나 이러한 강관은 제작효율이 저하되며, 또한 기둥-보 접합부에는 내측 다이아프램과 관통 다이아프램을 용접하는데 특수한 용접기술이 필요하다. 따라서, 얇은 강판을 절곡하는 방식으로 응력집중 위치의 용접을 피하고, 단면효율이 극대화된 내부앵커 돌출형의 용접조립 각형강관을 개발하게 되었다. 용접조립 각형강관은 강관내부에 스티프너가 설치되어 내측 다이아프램과 관통 다이아프램과 간섭이 발생하게 되므로 본 연구에서는 용접조립 각형CFT 기둥-보 접합부로 외다이아프램형식을 채택하고 외다이아프램의 설계식을 제안하였으며, 기둥-보 접합부의 거동을 파악하기 위해 실대형 4개 실험체를 제작하여 구조거동 및 내력을 분석하였다.

외다이아프램 응력경로에 따른 용접조립 각형기둥-보 접합부의 내진성능 평가 (Seismic Evaluation of Welded-formed square Column-Beam Connection for External Diaphragm Stress path)

  • 김선희;염경수;최성모
    • 한국강구조학회 논문집
    • /
    • 제26권4호
    • /
    • pp.311-322
    • /
    • 2014
  • 콘크리트 충전강관 기둥에 모멘트 접합부를 만들기 위해서는 추가적인 다이아프램 설치가 필요하다. 그 중 내측 다이아프램과 관통 다이아프램을 용접하기 위해서는 기둥강관에 특수한 용접기술이 필요하다. 하지만 이런 기술은 제작업체의 특수장비 보유에 따라서 제작성 저하와 생산단가 상승 유도 등의 문제를 갖고 있다. 따라서 본 연구에서는 외다이아프램을 갖는 실대형 기둥-보 접합부를 제작하였고, 반복가력 실험을 수행하였다. 다이아프램의 용접 유무와 콘크리트 충전 여부, 형상에 따른 총 6개의 T자형 접합부 실험을 통해 내진성능을 평가하였다. 또한 외다이아프램 내력식에 대한 분석이 이뤄졌다. 본 실험에서 나온 결과를 인장내력식의 적절성을 검토 하였다.

인장측 보플랜지의 항복선 모델을 이용한 CFCT기둥-H형강보 접합부의 국부내력평가 (Estimation of the Local Load-Carrying Capacities of CFCT Column to H-Beam Connections by Yield Line Model -With regard to the Tensile side of Beam flange-)

  • 강현식;문태섭
    • 한국강구조학회 논문집
    • /
    • 제10권3호통권36호
    • /
    • pp.525-536
    • /
    • 1998
  • 본 연구는 콘크리트 충전형 원형강관에 H형강보를 사용한 접합부의 내력을 항복선이론을 이용하여 구하였다. 3가지 유형의 항복선 모델이 제시되어 있다. 첫째는 단순화된 모델이며, 두 번째는 x와 kx로 수정된 모델이다. 나머지 하나는 모리타모델이다. 각 경우의 이론치와 실험치가 비교되었으며, 궁극적으로는 콘크리트 충전 원형강관기둥 접합부의 보강법을 연구하여 다이아프램이 없는 콘크리트 충전강관 기둥-H형강보 접합부의 개발을 위한 기초자료를 제시하는 것을 목적으로 하고 있다.

  • PDF

수직다이아프램을 사용한 충전형 각형강관기둥 접합부의 내력평가 (Structural Strength of Beam-to-CFT Connections with Vertical Diaphragm)

  • 김경태;이헌우;김영기;김태진;김종호
    • 한국강구조학회 논문집
    • /
    • 제29권3호
    • /
    • pp.237-247
    • /
    • 2017
  • 본 연구에서는 각형 강관 내부에 수직 다이아프램이 적용된 CFT 기둥 접합부의 구조적 특성에 대해 알아보았다. 각형 CFT 기둥의 거동을 파악하기 위해 실대형 3개 실험체를 제작하여 실험을 수행하였다. 유한요소해석을 통해 다이아프램의 거동을 확인하였으며 접합부 내력식을 제안하였다.

Reliability-based assessment of American and European specifications for square CFT stub columns

  • Lu, Zhao-Hui;Zhao, Yan-Gang;Yu, Zhi-Wu;Chen, Cheng
    • Steel and Composite Structures
    • /
    • 제19권4호
    • /
    • pp.811-827
    • /
    • 2015
  • This paper presents a probabilistic investigation of American and European specifications (i.e., AISC and Eurocode 4) for square concrete-filled steel tubular (CFT) stub columns. The study is based on experimental results of 100 axially loaded square CFT stub columns from the literature. By comparing experimental results for ultimate loads with code-predicted column resistances, the uncertainty of resistance models is analyzed and it is found that the modeling uncertainty parameter can be described using random variables of lognormal distribution. Reliability analyses were then performed with/without considering the modeling uncertainty parameter and the safety level of the specifications is evaluated in terms of sufficient and uniform reliability criteria. Results show that: (1) The AISC design code provided slightly conservative results of square CFT stub columns with reliability indices larger than 3.25 and the uniformness of reliability indices is no better because of the quality of the resistance model; (2) The uniformness of reliability indices for the Eurocode 4 was better than that of AISC, but the reliability indices of columns designed following the Eurocode 4 were found to be quite below the target reliability level of Eurocode 4.

T형 스티프너를 이용한 콘크리트 충전강관 기둥-보 접합부의 해석에 관한 연구 (Analysis of CFT Beam-to-Column Connections with T-Stiffeners)

  • 신경재;김현성
    • 한국강구조학회 논문집
    • /
    • 제17권3호통권76호
    • /
    • pp.375-384
    • /
    • 2005
  • 본 논문은 T형 스티프너를 이용한 콘크리트 충전각형강관-H형강보 접합부의 응력전달 메카니즘을 유한요소해석을 통해 정확히 이해하고, T스티프너에 관한 설계기본자료를 제공하는데 그 목적이 있다. 선행된 실대형 접합부의 실험결과에서 나타난 문제점을 파악하기 위해 실험체와 동일한 형상의 비선형 유한요소해석을 수행하여 결과를 비교하였다. 접합부의 응력전달 메카니즘을 이해하기 위해 T형 스티프너의 형상을 변수로 하여 주요 부위의 여러 응력 및 변형도 지수를 사용하였다. 해석 모델은 크게 T형스티프너 상세에 따라 3개의 계열로 분류하였다. 유한요소해석을 통한 변수해석의 결과를 이용하여 보플랜지와 수평스티프너 접합부의 응력집중을 감소시킬 수 있는 방안을 모색하였다. 접합부 상세에 따른 여러 지수의 변화를 토대로 하여 T형 스티프너의 설계를 위한 기본자료와 최소 크기를 제시하였다.

탄소섬유쉬트(CFRP Sheets)로 보강된 폭두께비가 큰 콘크리트 충전 각형강관 기둥의 중심축하중거동 (Axial Loading Behaviors of Square Concrete-Filled Tubular Columns with Large Width-to-Thickness Ratio Retrofitted using Carbon Fiber Reinforced Polymer Sheets(CFRP Sheets))

  • 박재우;유정한
    • 한국강구조학회 논문집
    • /
    • 제26권3호
    • /
    • pp.169-176
    • /
    • 2014
  • 본 연구에서는 콘크리트 충전 각형강관 (CFTP) 단주기둥에 CFRP 쉬트를 횡방향으로 보강하고 중심축하중 실험을 수행하였다. 실험변수는 b/t, CFRP쉬트 보강겹수이며, 총 6개의 실험체가 제작되었다. 실험변수로 사용된 판폭두께비는 b/t는 60, 80, 100이고 CFRP쉬트는 3겹 보강하였다. 실험결과 판폭두께비 100 실험체에서 CFRP쉬트 3겹 보강을 통해 내력을 16% 상승시켜 보강효과를 검증하였다. 내력 저하율을 검토한 결과 국부좌굴이 발생하지 않는 단면강도를 기준으로 최대 41%정도 내력이 저하되었으나, CFRP보강을 통해 32% 정도의 내력이 저하되어 보강효과를 검증할 수 있었다. 하중-변형를 관계를 보면 강재는 항복강도 이전에 국부좌굴이 발생하였으며, CFRP쉬트의 보강을 통해 국부좌굴을 지연시킴을 확인하였다.

Behavior of stiffened and unstiffened CFT under concentric loading, An experimental study

  • Deifalla, Ahmed F.;Fattouh, Fattouh M.;Fawzy, Mona M.;Hussein, Ibrahim S.
    • Steel and Composite Structures
    • /
    • 제33권6호
    • /
    • pp.793-803
    • /
    • 2019
  • Concrete-filled steel tubular (CFST) beam-columns are widely used owing to their good performance. They have high strength, ductility, large energy absorption capacity and low costs. Externally stiffened CFST beam-columns are not used widely due to insufficient design equations that consider all parameters affecting their behavior. Therefore, effect of various parameters (global, local slenderness ratio and adding hoop stiffeners) on the behavior of CFST columns is studied. An experimental study that includes twenty seven specimens is conducted to determine the effect of those parameters. Load capacities, vertical deflections, vertical strains and horizontal strains are all recorded for every specimen. Ratio between outer diameter (D) of pipes and thickness (t) is chosen to avoid local buckling according to different limits set by codes for the maximum D/t ratio. The study includes two loading methods on composite sections: steel only and steel with concrete. The case of loading on steel only, occurs in the connection zone, while the other load case occurs in steel beam connecting externally with the steel column wall. Two failure mechanisms of CFST columns are observed: yielding and global buckling. At early loading stages, steel wall in composite specimens dilated more than concrete so no full bond was achieved which weakened strength and stiffness of specimens. Adding stiffeners to the specimens increases the ultimate load by up to 25% due to redistribution of stresses between stiffener and steel column wall. Finally, design equations previously prepared are verified and found to be only applicable for medium and long columns.