• 제목/요약/키워드: Concrete)

검색결과 28,713건 처리시간 0.039초

CFRD 차부벽콘크리트의 수성수축균열 제어특성에 관한 실험적 연구 (An Experimental Study on the Control Property of PlasticShrinkage Crack for CFRD Face Slab Concrere)

  • 김완영;최세진;원종필
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.118-121
    • /
    • 2000
  • CFRD (Concrete Faced Rockfill Dam) face slab concrete has a much capability to occur crack due to drying shrinkage, hydration heat and bas compaction etc. Because of crack of concrete induce structural problem and decrease durability of concrete, it is need to reduce crack of concrete. This is an experimental study to analyze the Control Property of Plastic Shrinkage Crack for CFRD face slab concrete. For this purpose, it was investigated and analyzed the engineering properties of plain concrete and using admixtures (polypropylene fiber, fly-ash) according to test result As the result, it was found that crack width and area of concrete using admixtures less than of plain concrete.

  • PDF

CFRD 차수벽콘크리트에서의 섬유보강효과에 관한 실험적 연구 (An Experimental Study on the Effect if Fiber Reinforced on CFRD Face Slab Concrere)

  • 최세진;임정열;김완영;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.122-125
    • /
    • 2000
  • CFRD (Concrete Faced Rockfill Dam) face slab concrete has a much capability to occur crack due to drying shrinkage, hydration heat and bas compaction etc. Because of crack of concrete induce structural problem and decrease durability of concrete, it is need to reduce crack of concrete. This is an experimental study to analyze the effect of fiber reinforced on CFRD face slab concrete. for this purpose, it was investigated and analyzed the engineering properties of plain concrete and polypropylene fiber reinforced concrete (PFRC) according to test result ; the test include slump, air content, compressive strength, tensile strength, drying shrinkage and permeability etc. As the results, it was found permeability and drying shrinkage of PFRC less than that of plain concrete.

  • PDF

방청제를 함유한 콘크리트의 염소 이온 확산 특성 (Chloride Diffusion Properties of Concrete with Corrosion Inhibitor)

  • 구현본;이광명;정영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.694-699
    • /
    • 2000
  • Recently, the degradation of reinforced concrete structures due to physical and chemical attack has been a major issue in construction engineering. One of the main causes of degradation of concrete structures can be ascribed to chloride-induced corrosion, i.e., the rapid penetration of chloride ions into concrete. To estimate durability of reinforced concrete structures exposed to marine environment, many different kinds of accelerated tests to evaluate the concrete diffusivity were proposed. In this study, present test methods are reviewed and a proper test method for concrete is selected. The diffusion coefficients of concrete with corrosion inhibitor are measured using the proposed method, and then, measured values are compared to those of concrete without corrosion inhibitor. It is found from experimental results that diffusion coefficient re decreased with curing ages.

  • PDF

편심하증을 받는 고강도 철근콘크리트 기둥의 역학적 특성 (Mechanical Characteristics of Eccentrically Loaded High Strength Reinforced Concrete Columns)

  • 김인식;최봉섭;권영웅
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.399-404
    • /
    • 2000
  • This paper are the mechanical characteristics of eccentrically loaded normal strength and high strength reinforced concrete columns based on the test results. The columns are $120\times120$mmat the mid-section and are haunched at the ends to apply the eccentric loading and prevent premature failure. Variables are concrete strengths(361, 672, 974 kgf/$\textrm{cm}^2$), $\textrm{cm}^2$longitudinal reinforcement ratios (1.98, 3.54, 1 5.53%), spacing of lateral reinforcement (30, 60, 120mm), and eccentricities (24, 40mm). As a results, the main conclusions obtained from the comparison and analysis for the strength tendency, deformation and ductility of high strength reinforced concrete columns with variables are as follows; As the concrete compressive strength concrete and lateral reinforcement increases, the ductility index of high strength reinforced concrete columns decrease, but it increase with the increase of eccentricity and longitudinal reinforcement ratio. The confinement ratio must be greater than 20 percent in order for the level of ductility between high strength reinforced concrete columns and normal strength reinforced concrete columns to be almost equal.

  • PDF

매립형 철골합성구조의 부등건조수축에 따른 내부강재구속효과에 관한 연구 (Embeded-Steel Restraining Effects due to Differential Drying Shrinkage in SRC(Steel Reinforced Concrete ) Structures)

  • 조병환;김성호;김영진;고상윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.303-308
    • /
    • 2000
  • During the past few decades, several composite steel-concrete structural systems have been used and the demand of SRC (Steel Reinforced Concrete) structure increases on the construction of coping structures. But drying shrinking of concrete which is not uniform and the additional restraining effects of encased steel in concrete may cause the crack which leads to harmful damage to structure. In this study, specimens were made to show the restraining effects of embeded-steel in concrete and the differential drying shrinkage strains at various position of concrete were measured and analysed by Compensation Line Method. The results showed that there were remarkable difference in the drying shrinkage according to 속 depth of the concrete, and the tensile stress of the concrete near to encased steel showed the significant amount of stress contrary to 속 specimen which has no embeded-steel.

  • PDF

한중 콘크리트의 현장 실용화에 대한 연구 (An Experimental Study on the Practical Use of Cold Weather Concrete)

  • 소현창;정병욱;정경화;정문영;문성규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.861-865
    • /
    • 2000
  • During the placement of concrete in cold weather, there are serious problems due to frozen concrete in the early stage. These adverse effects prevent the hardening of concrete. There are special mixing, handling, placement and crying to minimize problems. Heat crying and sheet curing have been used in crying steps in order to reduce problems. However, these curing methods are not efficient because it is hard to obtain the good quality and strength of concrete, and moreover, it needs additional works for curing. In this study, we evaluate the application of cold weather concrete by the dose antifreezing admixture in concrete mix design. Because it is easy to handle inconstruction site and improve the quality of concrete. As the result of this paper is to present a successful case for the practical use of cold weather concrete.

  • PDF

철근 콘크리트 시험편의 철근방식에 관한 측정법 (Corrosion Measurements on Reinforcing Rebars in Reinforced Concrete Specimen)

  • 이강균;장지원;한기훈;정영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.281-286
    • /
    • 1997
  • Recent construction activities and maintenance of marine facilities have been accelerating to keep up with rapid economic growth in Korea. Marine concrete structures are exposed to salts an chloride from ocean environments. The corrosion of reinforcement steel caused by chloride-penetration into concrete may severely effect the durability of concrete structures. The objective of this research is to develop a durable concrete by investigating the corrosion resistance of various corrosion protection systems utilizing different water/cement ratio, silica fumes, corrosion inhibitors and etc. A tow-year verification test on various corrosion protection systems has been doing in the laboratory and at the seaside. Corrosion investigations on reinforcement steel are now under progress for more than 180 concrete specimen. Corrosion-related measurements include macrocell corrosion current, instant-off voltage between corroding and noncorroding reinforcement, chloride contents, the corroded surface areas on the reinforcement steel, and etc. A low level of corrosion is investigated on reinforcement steels in concrete specimen made with corrosion inhibitors or applied aqueous impregnating corrosion inhibitors into their surface, even though high chloride contents of concrete specimen.

  • PDF

콘크리트 표면처리와 CFRP 단부정착 방법에 따른 부착특성실험 (Experimental Study on the Bond[ Behavior with Concrete Surface Preparation. and Anchorage Type of CFRP)

  • 유영준;조정래;정우태;박종섭;박영환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.579-584
    • /
    • 2003
  • For strengthening deteriorated concrete structures, externally bonded FRP sheets or plates using epoxy resins are widely used. For the external FRP composites to be effective in improving the performance of the structure, bond between FRP composites and concrete is required. In general, the most frequently observed failure mode in FRP strengthened concrete structures is debonding failure at the interfacial section between FRP and concrete. Therefore, it is very important to find out the interfacial behavior properties. This paper presents experimental results of the relationship of concrete and FRP sheet for some conditions including concrete compressive strength, concrete surface preparation to observe the bond behavior between concrete and FRP sheet and various anchorage types to increase the bond capacity of FRP sheet.

  • PDF

팽창재를 혼입한 철근콘크리트 슬래브의 휨 거동에 관한 실험적 연구 (Experimental Study on Flexural Behavior of RC Slabs with Expansive Additives)

  • 박홍용;김철영;최익창;배상욱;이호석
    • 콘크리트학회논문집
    • /
    • 제12권4호
    • /
    • pp.31-40
    • /
    • 2000
  • This study aims to improve serviceability of concrete by inducing chemical prestress with the application of expansive additives for concrete. For this purpose, material tests and 4 point-bending tests of RC slabs were performed to verify the effect of expansive additives on the concrete. and the critical aspects of the structural behavior were investigated. The results of the material tests show that the optimal proportion of expansive additives is 13% of total cement weigth and the properties of expansive concrete in that proportion are the same as those of plain concrete. Both the experimental cracking load and service load of the expansive concrete slabs are increased in comparison with those of the plain concrete. In addition to the above results, the deflection of expansive concrete is smaller than that of plain concrete, and permanent strains resulting from cyclic load are decreased. It can be concluded that the use of expansive additives to induce chemical prestress in RC slabs greatly improves the serviceability.

폐콘크리트로부터 재생된 골재의 합리적 평가에 관한 연구 (A Study on Rational Evaluation of Recycled Aggregates Extracted from Demolished Concrete)

  • 송하원;변근주;하주형
    • 콘크리트학회논문집
    • /
    • 제12권5호
    • /
    • pp.3-12
    • /
    • 2000
  • Recently, the amount of disposed construction materials like demolished concrete is growing fast and the shortage of natural concrete aggregates is becoming serious. Therefore, recycling of aggregates extracted from the demolished concrete is getting important and use of the recycled aggregates for concrete has been seriously considered. However, the use of the recycled aggregates even for low performance concretes is very limited because there are few rational standard evaluation criteria for recycled aggregates which should be different from that for natural aggregates. In this study, rational evaluation criteria for the recycled aggregates are proposed for their use as concrete aggregates. The study also shows that the performance for both the recycled aggregates and the recycled concrete manufactured with the recycled aggregates can be evaluated effectively according to water absorption ratio of recycled aggregates.