• Title/Summary/Keyword: Concentration factor

Search Result 3,846, Processing Time 0.034 seconds

Study of atmosphere parameters of the IVV-2M reactor hall

  • M.E. Vasyanovich;M.V. Zhukovsky;E.I. Nazarov;I.M. Russkikh
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.3935-3939
    • /
    • 2023
  • The paper presents the results of a study of radioactive noble gases and from decay products in the atmosphere of the reactor hall of the research nuclear reactor IVV-2M. The distribution of short-lived 88Rb and 138Cs activity by sizes of aerosol particles was measured in the range of 0.5-1000 nm. It is shown that radioactive aerosols are characterized by three main modes with AMTD 2-3 nm, 7-15 nm and 400 nm. About 70% of aerosol activity is due to 88Rb. The equilibrium factor between 88Kr and 88Rb is 0.2 ± 0.1. The total concentration of aerosols particles was measured using an aerosol diffusion spectrometer. The value of unattached fraction of radioactive aerosols in the atmosphere of reactor hall IVV2M was f = 0.15-0.25 at the average total aerosol particles concentration from 20,000 cm3 to 53,000 cm3.

Stress concentration factors for multi-planar tubular KK-joints of jacket substructures in offshore wind turbines

  • Hamid Ahmadi;Adel Alizadeh Atalo
    • Ocean Systems Engineering
    • /
    • v.14 no.3
    • /
    • pp.237-259
    • /
    • 2024
  • Although the investigation on the effect of loaded out-of-plane braces on the values of the stress concentration factor (SCF) in offshore tubular joints has been the objective of numerous research works, a number of quite important cases still exist that have not been studied thoroughly due to the diversity of joint types and loading conditions. One of these cases is the multi-planar tubular KK-joint subjected to axial loading. Tubular KK-joints are among the most common joint types in jacket substructure of offshore wind turbines (OWTs). In the present research, data extracted from the stress analysis of 243 finite element (FE) models, verified against available experimental data, was used to study the effects of geometrical parameters on the chord-side SCFs in multi-planar tubular KK-joints subjected to axial loading. Parametric FE study was followed by a set of nonlinear regression analyses to develop three new SCF parametric equations for the fatigue analysis and design of axially loaded multi-planar KK-joints.

Optimization for the Bacterial Cellulose Production of Acetobacter xylinum KJ1 by Factorial Design (Factorial design에 의한 Acetobacter xylinum KJ1의 Bacterial cellulose 생산조건의 최적화)

  • 김성준;이지은;정상기;이용운
    • KSBB Journal
    • /
    • v.17 no.3
    • /
    • pp.228-234
    • /
    • 2002
  • Acetobacter xylinum KJ1 efficiently producing bacterial cellulose(BC) In shaking culture was isolated from a rotten grape. The strain was used to investigate optimum operating conditions for increasing BC production and factorial design model was employed for the optimization. The results of experiments were statistically analyzed by SAS program. Reciprocal effects of each factors(carbon source concentration, shaking speeds(rpm), oxygen pressure, and CSL concentration) and culture condition of BC production were examined by getting regression equation of the dependent variable. Comparisons between experimental results and predicted results about BC concentration were done in total 24 experiments by combination of each factors using SAS program, and the correlation coefficients of BC concentration and BC yield were 0.91 and 0.81, respectively. The agitated cultures were peformed in various operation conditions of factors which affected considerably to BC production in jar fermentor. The results showed that BC concentration was 11.67 g/L in 80 hours cultivation under the condition of carbon source concentration : shaking speeds(rpm) : oxygen pressure : CSL concentration : 4% : 460 rpm : 0.28 : 6%. On the other hand BC yield was 0.42 g/g in 80 hours cultivation under the condition of carbon source concentration : shaking speeds(rpm) : oxygen pressure : CSL concentration : 4% : 564 rpm : 0.21 : 2%. The BC production could be enhanced up to more than 2.4 times by factorial design. The result of a verifying experiment under the optimal conditions determined by the factorial design to the BC production showed that the model was appropriate by obtaining BC concentration of 11.47 g/L in the optimum condition.

A Study on Estimation of NOx and CO Emission Factor from Industrial and Commercial LNG Boilers (천연가스 사용 난방 및 산업보일러의 NOx와 CO 배출계수 산정 연구)

  • Jang, Young-Kee;Choi, Sang-Jin;Kim, Kwan;Song, Ki-Pong;Kim, Ho-Jung;Jung, Bong-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.5
    • /
    • pp.615-623
    • /
    • 2004
  • This study was conducted for developing the emission factors of nitrogen oxide(NOx) and carbon monoxide (CO) from the combustion boilers burning liquefied natural gas (LNG). These emission factors were compared with those of U.S. EPA and European Environment Agency (EEA). NOx and CO concentration in the flow gas were measured using Kane-May, KM9106 and Thermo Environmental Instruments Inc., 42C-HL. Measurement were conducted at thirty industrial and commercial LNG boilers. Emission factors were calculated on the basis of fuel consumption (kg-pollutant/㎥-fuel burned). NOx concentration at industrial boiler was 14~125 ppm and it was measured as 35~125 ppm at commercial boiler. NOx emission factors of industrial boiler and commercial boiler were 1.84kg/$m^3$ and 2.09kg/$m^3$, respectively. NOx emission factor of commercial boiler was higher than that of industrial boiler. The NOx emission factors estimated in this study were lower than those of U.S. EPA and higher than those of EEA. Average CO emission factor of industrial boiler was 0.65 kg/$m^3$ and at commercial boiler it was 0.70kg/$m^3$, CO emission factor at industrial boiler was lower than that at commercial boiler.

Nitrogen-Oxygen Separation Characteristics by Polyimide Membrane System for Controlled Atmosphere Storage (CA저장을 위한 폴리이미드 막 시스템의 질소-산소 분리특성)

  • 이호원;현명택;고정삼
    • Food Science and Preservation
    • /
    • v.5 no.3
    • /
    • pp.239-246
    • /
    • 1998
  • Polyimide membrane system was designed for manufacturing nitrogen-enriched gas, and basic technical data was suggested for appling this system to controlled atmosphere storage. The permeability characteristics of pure oxygen and nitrogen could be explained by dual-mode sorption model. There was substantial decrease in the permeation rates of oxygen, which is the more permeable gas, through the polyimide membrane due to the presence of nitrogen in comparison with pure oxygen. However, the permeation rates of nitrogen was increased by the presence of oxygen. The ideal separation factor was in the range of 5 to 6 in the range of temperature and pressure difference studied, and the separation factor of air was lower than the ideal separation factor. The increase of ideal separation factor with increasing temperature is due to the fact that the activation energy for oxygen is larger than that for nitrogen. Nitrogen concentration decreased rapidly with increasing product recovery, and it was found that this is a major operating factor to obtain nitrogen concentration required for controlled atmosphere storage. A relation equation, by which nitrogen concentration in storehouse can be predicted, was suggested under the establishment of a hypothetical model for controlled atmosphere storage process using polyimide membrane system.

  • PDF

An Effect of TIG Dressing on Fatigue Characteristics of Non Load-Carrying Fillet Welded Joints (TIG처리에 따른 하중비전달형 필렛용접부의 피로특성)

  • Jung, Young Hwa;Kyung, Kab Soo;Hong, Sung Wook;Kim, Ik Gyeom;Nam, Wang Hyone
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.5 s.48
    • /
    • pp.617-628
    • /
    • 2000
  • In this study, the 4-point bending test has been performed in order to estimate the effect of TIG-dressing on fatigue strength and fatigue characteristics quantitatively for non load-carrying fillet welded joints subjected to pure bending. As a result of fatigue tests, fatigue strength of as-welded specimens has been satisfied the grade of fatigue strength prescribed in specifications of domestics and AASHTO & JSSC, and fatigue strength at $2{\times}106cycles$ of TIG-dressing specimens has been increased compared with as-welded specimens. As the result of beachmark tests, fatigue cracks have been occurred at several points, where the radius of curvature and flank angle in the weld bead toes are low, and grown as semi-elliptical cracks, then approached to fracture. As a result of finite element analysis, stress concentration factor in weld bead toes has been closely related to the flank angel and radius of curvature, and between these, the radius of curvature has more largely affected in stress concentration factor than flank angle. As a result of fracture mechanics approaches, the crack correction factor of test specimens has been largely affected on stress gradient correction factor in case a/t is below 0.4. From the relations between stress intensity factor range estimated from FEM analysis and fatigue crack growth rate, fatigue life has been correctly calculated.

  • PDF

Characteristics of PM10 in Gwangju Using Factor Analysis (인자분석을 이용한 광주지역 미세먼지(PM10)의 특성 연구)

  • Lee, Se-Haeng;Seo, Gwang-yeop;Yoon, Sang-Hoon;Yang, Yoon-Cheol;Kim, Sun-Jung;Cho, Young-gwan;Bae, Seok-Jin
    • Journal of Environmental Science International
    • /
    • v.27 no.4
    • /
    • pp.241-250
    • /
    • 2018
  • The objective of this study was to estimate air quality trends in the study area by surveying monthly and seasonal concentration trends. To do this, the mass concentration of $PM_{10}$ samples and the metals, ions, and total carbon in the $PM_{10}$ were analyzed. The mean concentration of $PM_{10}$ was $33.9{\mu}g/m^3$. The composition of $PM_{10}$ was 39.2% ionic species, 5.1% metallic species, and 26.6% carbonic species (EC and OC). Ionic species, especially sulfate, ammonium, and nitrate, were the most abundant in the $PM_{10}$ and had a high correlation coefficient with $PM_{10}$. Seasonal variation of $PM_{10}$ showed a similar pattern to those of ionic and metallic species. with high concentration during the winter and spring seasons. $PM_{10}$ showed high correlation with the ionic species $NO_3{^-}$ and $NH_4{^+}$. In addition, $NH_4{^+}$ was highly correlated with $SO{_4}^{2-}$ and $NO_3{^-}$. We obtained four factors through factor analysis and determined the pollution sources using the United States Environmental Protection Agency(U.S. EPA) pollution profile. The first factor accounted for 51.1% of $PM_{10}$ from complex sources, that is, soil, motor vehicles, and secondary particles: the second factor indicated marine sources; the third factor, industry-related sources; and the last factor, heating-related sources. However, the pollution profile used in this study may be somewhat different from the actual situation in Korea because it was from US EPA. Therefore, to more accurately estimate the pollutants present, it is necessary to create a pollution profile for Korea.

The Study of CYFRA 21-1 and Epidermal Growth Factor Receptor Levels in Cancer Tissue of Bronchogenic Carcinoma Patients (폐암환자의 암조직내 CYFRA 21-1과 Epidermal Growth Factor Receptor의 측정치에 대한 연구)

  • 김대연;김송명
    • Journal of Chest Surgery
    • /
    • v.30 no.9
    • /
    • pp.854-861
    • /
    • 1997
  • CYPRA 21-1 is known to be a cytokeratin 19 fragment, and it can be detected by using two specific monoclonal antibodies (KS 19-1 and BM 19-21) and can be clinically applied as a useful circulating tumor marker The epidermal growth factor receptor (EGF-R) expression was evaluated and characterized by its tyrosine protein kinase activity and by its ligand-stimulated autophosphorylation, a property shared with other peptide growth factor receptors. Autocrine or para'urine action was initiated by a growth factor, or by a transforming growth factor o, which had an extensive homology with EGP and which also stimulated tyrosine kinase activity on the EGF-R. The CYFRA 21-1 and the EGF-R levels in 30 patients with primary lung tumors were investigated. There were 24 patients with squamous cell carcinomas and 6 patients with adenocarcinomas. Specimen 5 mm3 in size were sampled at three different locations ; the main lesion, the boundary between the lesion and the unaffected tissue, and the unaffected tissue of the patients. The results were as follows 1. The CYPRA 21-1 concentration in the cancer boundary, the most malignant region,(348.6 : 89.9 ng/ml) was the lowest value. The CYFRA 21-1 concentration in unaffected tissue,(718.4$\pm$77.8 ng/ml) was higher than that in the main lesion. which had intact cellularity. 2. The EGF-R concentration in the main lesion was higher than that in the unaffected tissue, and the EGF-R concentration in a squamous cell cacinoma was higher than that in an adenocarcinoma. also, the EGF-R concentration in the cancer b undary was highest at stage 1, ll. The EGF-R concentration was higher in the main cancer lesion that in the unaffected tissue at stage 111, IV. 3. The CYFRA 21-1 was a cytoplasmic skeleton and the EGF-R was a cell-wall component; there was no correlation. In conclusion, CYFRA 21-1 was abundant in the cytoplasm but had a higher concentration in the unaffected tissue than in the main cancer lesion. The CYFRA 21-1 concentration of the tissue did not reflect the amount of cancer activity, the EGP-R was located in the cell membrane, the level of tissue that reflects cancer activity, so the main cancer lesion had a higher concentration than the unaffected tissue. CYFRA 21-1 is not a useful tumor maker at the tissue level. Because the EGF-R concentration re(looted the cancer activity, its a useful tumor marker for lung cancer.

  • PDF

Effects of Titrated Extract of Centella asiatica and Epidermal Growth Factor on the Proliferation of Human Epidermal Keratinocyte (Centella asiatica 추출물 및 표피성장인자가 각질형성세포의 증식에 미치는 효과)

  • 김홍표;김영중
    • Biomolecules & Therapeutics
    • /
    • v.3 no.1
    • /
    • pp.80-84
    • /
    • 1995
  • Effects of titrated extract of Centella asiatica (TECA) and epidermal growth factor (EGF) isolated from the urine of pregnant horse on the proliferation of human epidermal keratinocyte in culture were studied. An increase in the number of keratinocyte was observed with the treatment of TECA at the concentration ranges from 1 $\mu\textrm{g}$/mι to 100 $\mu\textrm{g}$/mι. Effects of low molecular weight EGF (LEGF) and high molecular weight EGF (HEGF) on the proliferation of keratinocyte in culture were also studied. The number of keratinocyte in culture was significantly increased with LEGF and HEGF respectively at the concentration of 10 ng/mι. Simultaneous treatment of the keratinocyte with LEGF, HEGF and TECA led to the increased proliferation of keratinocytes resulting 96% of the effect of a positive control, EGF isolated from mouse submaxillary glands.

  • PDF

An experimental study on the fragility factor of high strength concrete (고강도 콘크리트의 취도계수에 관한 실험적 연구)

  • Kim, Hui-Doo;Yang, Seong-Hwan
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.148-149
    • /
    • 2014
  • In modern society, population overcrowding and concentration of facilities are happened because of the concentration on to city. So this phenomenon demands improvement of material's performance, technical development of structure analysis and design and improvement of constructing ability .High strength concrete has some merits. High strengthening makes the cross section reduced, and that cause decrease of structure weight. And using high durable and superplasticizer promote liquidity, thus high quality concrete can be produced. Because of these advantages, this study is for showing validity of using it by compression/tensile strength experiment. As this experiment's result, when concrete become stronger, interface intensity coefficient between cement and aggregate is different and they don't adhere to each other. So there is brittle failure. Fragility factor also steadily increase with strong concrete, it tells high strength concrete has problem. Therefore the sources used in high strength concrete like cement and aggregate must have great quality. So the source's performance must be supervised well because their quality decides performance criteria.

  • PDF