• Title/Summary/Keyword: Concentration breakthrough curve

Search Result 62, Processing Time 0.028 seconds

Desorption characteristics of Activated Carbon and Activated Carbon Fiber by Development of Sorbent Tube for Measurement of Organic Solvent (유기용제 측정용 흡착관 개발을 위한 AC 및 ACF의 흡착특성)

  • 원정일;김기환;신창섭
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.3
    • /
    • pp.99-109
    • /
    • 2002
  • Charcoal $tube/CS_2$ method are more popularly used than any other in the measurement of the working environment for the exposure evaluation of organic solvent, but it is some weak points that the lower accuracy can be obtained on the polar materials and within the range of the low concentration. Thus solvent desorption method has been developed to make accuracy higher and to overcome some weak points. However, because of high price of adsorption tube for thermal desorption and the short of study on its application to the working environment, it is not popularly used in the domestic industrial hygiene fields. This dissertation aims to develop thermal desorption and adsorption tubes for measuring organic solvents in the working environment, by comparing and analyzing breakthrough condition and adsorption capacity with ACF. Specific surface area of ACF used in this study is wider than the one of AC and micropore of ACF related with adsorption has been developed, and adsorption velocity and adsorption amount are very excellent by linking a pore of surface and an inside well into micropore. 1. Result of analysis on physical characteristics of adsorbent, the specific surface area of ACF was 1.3 times higher than that of AC. Distribution ratio of micropore related to adsorption was 94% on ACF and AC. Result of SEM, micropore of the AC is opened to the surface. In contrast, ACF shows that extremely fast adsorption speed. Because of micropore are exposed on the surface and penetrate through each other. 2. Breakthrough characteristics of adsorbents was not different from slop of breakthrough curve. The effluent concentration reaches 10% of initial concentration($C_{out}/C_{in}=0.1$, break point) of ACF was 30~316min longer than that of AC. Therefore, the adsorption capacities of ACF was 1.1~4.6 times higher than that of AC. ACF can be used as a proper adsorbent for measurement of organic solvent.

Characterization of Adsorbents for the Simultaneous Solid-Phase Extraction of Trace $\beta$-Blockers from Biological Samples (생체시료로부터 미량 $\beta$-Blockers의 동시고상추출에 사용될 흡착제들의 특성)

  • Kim, Kyoung Rae;Kim, Do Jeong
    • Analytical Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.375-381
    • /
    • 1993
  • The efficiencies of four different solid absorbents were evaluated for the simultaneous solid-phase extraction of six ${\beta}$-blockers from biological sample. Chromosorb 107 using methanol as the eluting solvent gave the highest solid-phase extraction yield. From the breakthrough studies of ${\beta}$-blockers, the excellent sorption and desorption properties of the Chromosorb 107 column were verified. The usefulness of Chromosorb 107/methanol was examined for the simultaneous solid-phase extraction of the ${\beta}$-blockers from serum in the concentration range of 2~8ppm.

  • PDF

Breakthrough Curves and Miscible Displacement of Cadmium Through Double-Layered Reclaimed Soils Amended with Macroporous Granule

  • Kim, Hye-Jin;Ryu, Jin-Hee;Kim, Si-Ju;Park, Mi-Suk;Chung, Doug-Young
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.1
    • /
    • pp.15-21
    • /
    • 2011
  • Transport of heavy metals such as Cd is affected by several rate-limiting processes including adsorption and desorption by exchange reactions in soils. In this study, column transport and batch kinetic experiments were performed to assess Cd mobility in a double-layered soil with a reclaimed saline and sodic soil (SSS) as top soil and macroporous granule (MPG) as a bottom layer. For individual soil layer having different physical and chemical properties, Cd was considered to be nonlinear reactivity with the soil matrix in layered soils. The dispersive equation for reactive solutes was solved with three types of boundary conditions for the interface between soil layers. The adsorption of Cd with respect to the saline-sodic sandy loam and the MPG indicated that the nature of the sites or the mechanisms involved in the sorption process of Cd was different and the amounts of Cd for both of samples increases with increasing amounts of equilibrium concentration whereas the amount of Cd adsorbed in saline-sodic sandy loam soil was higher than that in MPG. The results of breakthrough curve indicating relative Cd retardation accompanied by layer material and sequence during leaching showed that the number of pore volumes to reach the maximum relative concentration of 1 increased in the order of MPG, SSS, and double layer of SSS-MPG. Breakthrough curves (BTCs) from column experiments were well predicted with our double-layered model where independently derived solute physical and retention parameters were implemented.

Adsorption Charateristics of Tartrazine by Activated Carbon (활성탄에 의한 Tartrazine의 흡착 특성)

  • Yoon, Sung Wook;Lee, Jong-Jib
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.568-572
    • /
    • 2009
  • The adsorption characteristics of tartrazine by granular activated carbon were experimentaly investigated in the batch adsorber and the packed column. The adsorptivity of activated carbon for tartrazine was largely improved by pH control, and 98 percent of initial concentration could be removed at pH 3. It was estabilished that the adsorption equilibrium of tartrazine on granular activated carbon was sucessfully fitted by Freundlich isotherm equation in the concentration range from 50 mg/L to 1,000 mg/L. The characteristics of breakthrough curve of activated carbon packed column, which depend on the design variables such as initial concentration, bed height, and flow rate, were studied.

Adsoption Removal of PCBs by Activated Carbon (활성탄에 의한 PCBs의 흡착제거)

  • Yu, Yong-Ho;Lee, Jong-Jig
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.1 s.73
    • /
    • pp.59-64
    • /
    • 2006
  • In this study, adsorption characteristics of PCBs on granular activated carbon were experimentally investigated in a batch reactor and in a fixed bed reactor. Granular activated carbon removed above 98.4% of initial concentration, 1000mg/L, of PCBs. It was estabilished that the adsorption equilibrium of PCBs on granular activated carbon was more successfully fitted by Freundlich isotherm equation in the concentration range from 1 to 1000mg/L. Because Freundlich parameter, ${\beta}$ is 0.346, removall treatment of PCBs by activated carbon accounts for the fact that toxicity reduction can be achieved through this process. Appearance time of breakthrough curve is faster with the increase flow rate and inflow concentration of liquid. The utility of granular activated carbon is enhanced with the increase of bed height and with the decrease of inflow rate.

Removal of Amaranth by Activated Carbon Adsorption (활성탄 흡착에 의한 Amaranth의 제거)

  • Lee, Jong-Jib;Yoon, Sung-Wook
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.4
    • /
    • pp.34-39
    • /
    • 2009
  • The adsorption characteristics of amatanth by granular activated carbon were experimently investigated in the batch adsorber and the packed column. The adsorptivity of activated carbon for amaranth were largely improved by pH control, and 94 percent of initial concentration(100mg/L) could be removed at pH 9. It was estabilished that the adsorption equilibrium of amaranth on granular activated carbon was sucessfully fitted by Freundlich isotherm equation in the concentration range from 1mg/L to 100mg/L. The characteristics of breakthrough curve of activated carbon packed column, which depend on the design variables such as initial concentration, bed height, and flow rate, were studied.

Adsorption Characteristics of Toluene Vapor in Fixed-bed Activated Carbon Column (고정층 활성탄 흡착반응기에서 기상 톨루엔의 흡착특성)

  • Lim Jin-Kwan;Lee Song-Woo;Kam Sang-Kyu;Lee Dong-Whan;Lee Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.14 no.1
    • /
    • pp.61-69
    • /
    • 2005
  • Adsorption characteristics of toluene vapor, which is one of important source of volatile organic compounds (VOCs), by activated carbon were investigated using a fixed bed adsorption column. The operating parameters such as breakthrough curve, adsorption capacity, mass transfer zone (MTZ), and length of unused bed (LUB) were studied. The experimental results showed that the breakthrough time decreased with increasing inlet toluene concentration and gas flow rate. MTZ and LUB increased with the increase of inlet concentration, gas flow rate, and particle size of activated carbon. The adsorption capacity increased with the increase of inlet toluene concentration, while it decreased with increasing particle size. However, it was kept at constant value regardless of the increase of gas flow rate. Adsorption isotherm of toluene vapor could be represented by the Freundlich adsorption equation fairly well. From the adsorption experiments using some VOC gases such as toluene, xylene, butyl acetate. butanol and acetone, it was also found that the adsorption capacity was higher in the case of gas with higher boiling point and lower vapor pressure.

Study on Retardation Effect of a Heavy Metal in Sandy Soils

  • Kim, Dong-Ju;Sung, Baek-Doo
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.06a
    • /
    • pp.43-49
    • /
    • 1998
  • Retardation effect of heavy metals in soils caused by adsorption onto the surfaces of solids particles is well known phenomena. The adsorption of metal ions has been recognized more strong in clay mineral and organic matter contents rather than sands and gravels. In this study, we investigated the retardation effect in two sandy soils by conducting batch and column tests. The column tests were conducted to obtain the relationship between concentration and time known as breakthrough curve (BTC). We applied pulse type injection of ZnCl$_2$solution on the inlet boundary and monitored the effluent concentration at the exit boundary under steady state condition using EC-meter and ICP-AES. Batch test consisted of an equilibrium procedure for fine fractions collected from two sandy soils for various initial ZnCl$_2$concentrations, and analysis of Zn ions in equilibrated solution using ICP-AES. The results of column test showed that i) the peak concentration of Zn analyzed by ICP was far less than that detected by EC-meter for both soils and ii) travel times for peak concentration were more less identical for two different monitoring techniques. The first result can be explained by ion exchange between Zn and other cations initially present in the soil particles since ICP analysis showed a significant amount of Ca, Mg ions in the effluent. From the second result, we found that retardation effect was not present in these soils due to strong cation exchange capacity of Zn ion over other cations since we did not apply a solution containing more adsorptive cations such as Al. The result of batch test also showed high distribution coefficients (K$_{d}$) for two soils supporting the dominant ion exchange phenomena. Based on the retardation factor obtained from the Kd, we predicted the BTC using CDE model and compared with the BTC of Zn concentration obtained from ICP The predicted BTC, however, disagreed with the monitored in terms of travel time and magnitude of the peak concentrations. The only way to describe the prominent decrease of Zn ion was to introduce decay or sink coefficient in the CDE model to account for irreversible decrease of Zn ions in liquid phase.e.

  • PDF

Adsorption Characteristics of H2S on Adsorbent Made by Sewage Sludge in Fixed Bed Adsorption Column (하수슬러지를 활용하여 제조한 흡착제의 고정흡착층에서의 H2S 흡착특성)

  • Park, Chun-Dong;Youn, Ju-Young;Park, Yeong-Seong
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.718-722
    • /
    • 2012
  • $H_2S$ adsorption characteristics of adsorbent made by sewage sludge were investigated. For analyses of the manufactured adsorbent, various methods such as Iodine adsorptivity, scanning electron microscope (SEM), and measurements of BET surface area and pore volume were adopted. As the major adsorption characteristic, breakthrough curve was measured by using a continuous fixed bed adsorption column for operating variables such as adsorption temperature ($25{\sim}45^{\circ}C$), aspect ratio (L/D)(3~9), gas flow rate (0.1~2.0 liter/min) and $H_2S$ gas concentration (50~200 ppm). The experimental result showed that the carbonization and activation of sewage sludge are very important for the improvement in $H_2S$ adsorption capacity.

Continuous Ion Exchange Characteristics of Ni, Co and Ag Ions in Acidic-Oxidizing Conditions (산성-산화성 분위기에서 니켈(Ni), 코발트(Co) 및 은(Ag) 이온의 연속식 이온교환 특성)

  • Kim, Young H.;Yang, Hyun S.;Kim, Woong K.
    • Applied Chemistry for Engineering
    • /
    • v.10 no.2
    • /
    • pp.218-224
    • /
    • 1999
  • Continuous ion exchange characteristics of the synthetic coolant contained Ni, Co and Ag ions of low concentration in acidic-oxidizing conditions have been studied to suggest the guideline for the optimum operation of mixed-bed demincralizer during the shutdown period of a pressurized water reactor (PWR). In the effect of the form of cation resins on the removal capacity of metal ions, the performance of a $H^+$-form resin was about 6% higher than that of a $Li^+$-form resin. Mixed-bed of cation and anion resins in comparison with nonmixed-bed of them, had no affected on the removal capacity of metal ions but very slightly increased the slope of breakthrough curves of metal ions. In the effect related to acidic-oxidizing conditions of the coolant, the addition of boric acid very slightly decreased the slope of breakthrough curves of metal ions, while the addition of hydrogen peroxide slightly decreased the removal capacity of metal ions.

  • PDF