Characterization of Adsorbents for the Simultaneous Solid-Phase Extraction of Trace $\beta$-Blockers from Biological Samples

생체시료로부터 미량 $\beta$-Blockers의 동시고상추출에 사용될 흡착제들의 특성

  • 김경례 (성균관대학교 약학대학 제약학과) ;
  • 김도정 (성균관대학교 약학대학 제약학과)
  • Received : 1993.12.02
  • Published : 1993.10.25

Abstract

The efficiencies of four different solid absorbents were evaluated for the simultaneous solid-phase extraction of six ${\beta}$-blockers from biological sample. Chromosorb 107 using methanol as the eluting solvent gave the highest solid-phase extraction yield. From the breakthrough studies of ${\beta}$-blockers, the excellent sorption and desorption properties of the Chromosorb 107 column were verified. The usefulness of Chromosorb 107/methanol was examined for the simultaneous solid-phase extraction of the ${\beta}$-blockers from serum in the concentration range of 2~8ppm.

생체시료 중 ${\beta}$-blockers의 동시분석을 위한 시료 전처리 과정에서 고상추출법을 사용하기 위해 4가지 흡착제의 흡착 및 탈착 효율을 조사하였다. 용출 용매로서 methanol을 사용하였을 때 Chromosorb 107이 가장 높은 회수율을 보였다. ${\beta}$-Blockers의 breakthrough 조사를 하여 Chromosorb 107 컬럼의 우수한 흡착 및 탈착 성질을 혈청 중 2~8 ppm 농도 범위의 ${\beta}$-blockers를 동시에 고상추출하는 데 Chromosorb 107/methanol의 유용성을 조사하였다.

Keywords

Acknowledgement

Supported by : 한국과학재단