• 제목/요약/키워드: Concentration Characteristics

검색결과 9,718건 처리시간 0.039초

Analysis of Seasonal Airborne Radon Concentration Characteristics in Public-Use Facilities

  • Young-Do KIM;Woo-Taeg KWON
    • 웰빙융합연구
    • /
    • 제6권2호
    • /
    • pp.1-7
    • /
    • 2023
  • Purpose: The purpose of this study is to investigate the characteristics of airborne radon concentration by season in public-use facilities in South Korea. Research design, data and methodology: The data is provided by the public data portal, and public-use facilities nationwide where radon in the air is measured are specialized sanatorium for senior citizens, libraries, childcare facilities, postpartum care centers, medical institutions, funeral halls, underground shopping malls, and underground subway stations. Results: The facility with the highest radon concentration in public-use facilities was childcare facilities with an average of 50.2 ± 21.7 Bq/m3, while the average of medical institutions was the lowest at 24.8 ± 5.7 Bq/m3. The season with the largest difference in average radon concentration between childcare facilities and medical institutions was in the order of fall (28.6 Bq/m3), followed by winter (28.1 Bq/m3), spring (23.0 Bq/m3), and summer (22.0 Bq/m3). Conclusions: The main concentration levels of each public-use facility shown in this study are all below domestic and international standards, but there is a significant concentration difference between facilities. By season, winter showed the highest average concentration (40.6 ± 21.3 Bq/m3) and summer showed the lowest average concentration (23.8 ± 14.0 Bq/m3).

농촌유역에서의 오염부하특성 (Characteristics of Pollutant Loadings in a Rural Watersheds)

  • 조재원;김진수;오광영
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2002년도 학술발표회 발표논문집
    • /
    • pp.449-452
    • /
    • 2002
  • Characteristics of pollutant load during irrigation and non-irrigation periods was investigated for streamwater from a rural watershed. Water was sampled and discharge was measured at 5-days intervals at outlet of study area. The mean concentrations of TN and TP in an irrigation period are higher than in an non-irrigation period, while mean COD concentration in an irrigation period is lower than in a non-irrigation period. For increasing discharge during an irrigation period, TN concentration increase, TP concentration is nearly unchanged, and COD concentrations decreases.

  • PDF

유우종모우 정액의 생상간 상관관계에 관한 연구 (Studies on the Correlation among the Semen Characteristics of Holstein Bulls)

  • 김인철;김학규;정행기;김경남;정길생
    • 한국가축번식학회지
    • /
    • 제10권2호
    • /
    • pp.188-191
    • /
    • 1986
  • This experiment was carried out to examine the correlation among the semen characteristics of Holstein bulls. Seventy-two samples of semen were collected from 6 Holstein bulls, 2 to 10 years old. The characteristics of the semen were estimated by ordinary methods. The results obtained in this experiment were summarized as follows: 1. Semen characteristics on an average were 6.0 ml of volume, 16${\times}$108/ml of concentration, 92.4${\times}$108 of total sperm number(TSN), 72.1% of motility and 4.6% of abnormality. 2. Semen volume was positively high correlated (P<0.01) with total sperm number, but negative correlation was observed with the sperm motility (P<0.05) and semen concentration. 3. In relation to their age, older bulls semen volume and total sperm number were increased (P<0.01), but semen concentration and motility were decreased (P<0.01).

  • PDF

Electrical Characteristics of Poly(ethylene oxide)-urea Complex Films

  • Cho, Mi-Yeon;Cho, Kyoung-Ah;Kim, Sang-Sig
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권3호
    • /
    • pp.136-138
    • /
    • 2012
  • The electrical characteristics of complex films composed of poly(ethylene oxide) (PEO) and urea as a function of the urea concentration were examined in this study. Moreover, their structural characteristics were also compared. Depending on the urea concentration, the structural phases were classified as PEO+${\beta}$-phase composite, ${\beta}$-phase+${\alpha}$-phase composites, or ${\alpha}$-phase composite+urea. At urea concentrations below ~0.064 M, the ${\beta}$-phase was dominant in the complex film. Moreover, the conductance increased rapidly with an increase in the urea concentration. For urea concentrations ranging from ~0.064 to ~0.25 M, the ${\beta}$-phase was gradually substituted by the ${\alpha}$-phase. As the film was composed entirely of the ${\alpha}$-phase at urea concentrations greater than ~0.25 M, its conductance was decreased. In this study, the electrical characteristics observed for the different phases are analyzed and discussed.

부산지역 겨울철 고농도 미세먼지 발생일의 기상학적 특성 (Meteorological Characteristics of the Wintertime High PM10 Concentration Episodes in Busan)

  • 전병일
    • 한국환경과학회지
    • /
    • 제21권7호
    • /
    • pp.815-824
    • /
    • 2012
  • The purpose of this study was to analyze the meteorological characteristics of wintertime high PM10 concentration episodes in Busan. $PM_{10}$ concentration has been reduced for the past four years and recorded near or exceeded 100 ${\mu}g/m^3$ (national standard of $PM_{10}$). High concentration episodes in Busan were 6 case, $PM_{2.5}/PM_{10}$ ratio was 0.36~0.39(mean 0.55). High $PM_{10}$ concentration occurred during higher air temperature, more solar radiation and sunshine, lower relative humidity, and smaller cloud amount. Synoptically, it also occurred when Busan was in the center or the edge of anticyclone and when sea breeze intruded. An analysis of upper air sounding showed that high $PM_{10}$ concentration occurred when surface inversion layer and upper subsidence inversion layer existed, and when boundary layer depth and vertical mixing coefficient were low. An analysis of backward trajectory of air mass showed that high $PM_{10}$ concentration was largely affected by long range transport considering that it occurs when air mass is intruded from China.

Biological Aerated Filter에서 유입 질소농도에 따른 아질산화 특성 (Nitritation Characteristics Depending on Influent Nitrogen Concentration in a Biological Aerated Filter)

  • 유익근
    • 한국물환경학회지
    • /
    • 제30권1호
    • /
    • pp.1-7
    • /
    • 2014
  • The purpose of this study was to investigate the nitrification characteristics of biological aerated filter (BAF) packed with ceramic media, especially focusing on nitrite build-up during nitrification. When increasing the nitrogen load above $1.63kgNH_4{^+}-N/m^3{\cdot}d$, ammonium removal efficiency decreased to less than 60% and the nitrite ratio ($NO_2{^-}-N/NO_x-N$) of higher than 75% was achieved due to the inhibitory free ammonia (FA, $NH_3-N$) concentration and oxygen limitation. FA inhibition, however, is not recommended strategy to promote nitrite build-up since FA concentration in the reactor is coupled with decreased ammonium removal efficiency. Nitrite ratio in the effluent was also affected by aeration rate and influent ammonium concentration. Ammonium oxidation was enhanced at a higher aeration rate regardless of influent ammonium concentration but, the nitrite ratio was dependent on both aeration rate and influent ammonium concentration. While a higher nitrite ratio was obtained when BAFs were fed with $50mgNH_4{^+}-N/L$ of influent, the nitrite ratio significantly decreased for a greater influent concentration of $200-300mgNH_4{^+}-N/L$. Taken together, aeration rate, influent ammonium concentration and FA concentrations kept in the BAF were found to be critical variables for nitrite accumulation in the BAF system.

Effect of Post-CMP Cleaning On Electrochemical Characteristics of Cu and Ti in Patterned Wafer

  • Noh, Kyung-Min;Kim, Eun-Kyung;Lee, Yong-Keun;Sung, Yun-Mo
    • 한국재료학회지
    • /
    • 제19권3호
    • /
    • pp.174-178
    • /
    • 2009
  • The effects of post-CMP cleaning on the chemical and galvanic corrosion of copper (Cu) and titanium (Ti) were studied in patterned silicon (Si) wafers. First, variation of the corrosion rate was investigated as a function of the concentration of citric acid that was included in both the CMP slurry and the post-CMP solution. The open circuit potential (OCP) of Cu decreased as the citric acid concentration increased. In contrast with Cu, the OCP of titanium (Ti) increased as this concentration increased. The gap in the OCP between Cu and Ti increased as citric acid concentration increased, which increased the galvanic corrosion rate between Cu and Ti. The corrosion rates of Cu showed a linear relationship with the concentrations of citric acid. Second, the effect of Triton X-$100^{(R)}$, a nonionic surfactant, in a post-CMP solution on the electrochemical characteristics of the specimens was also investigated. The OCP of Cu decreased as the surfactant concentration increased. In contrast with Cu, the OCP of Ti increased greatly as this concentration increased. Given that Triton X-$100^{(R)}$ changes its micelle structure according to its concentration in the solution, the corrosion rate of each concentration was tested.

부산 구덕산 미세먼지의 금속성분 및 이온성분 농도 특성 (Characteristics of Metallic and Ionic Elements Concentration in PM10 at Guducsan in Busan)

  • 전병일
    • 한국환경과학회지
    • /
    • 제25권5호
    • /
    • pp.715-726
    • /
    • 2016
  • This study investigates the characteristics of metallic and ionic elements concentration, concentration according to transport path, and factor analysis in $PM_{10}$ at Guducsan in Busan in the springtime of 2015. $PM_{10}$ concentration in Guducsan and Gwaebeopdong were $59.5{\pm}9.04{\mu}g/m^3$ and $87.5{\pm}20.2{\mu}g/m^3$, respectively. Contribution rate of water-soluble ions and secondary ion in $PM_{10}$ concentration in Guducsan were 37.0% and 27.8% respectively. [$NO_3{^-}/SO{_4}^{2-}$] ratio and contribution rate of sea salt of $PM_{10}$ in Guducsan and Gwaebeopdong were 0.91 and 1.12, 7.0% and 5.3%, respectively. The results of the backward trajectory analysis indicates that $PM_{10}$ concentration, total inorganic water-soluble ions and total secondary ions were high when the air parcels moved from Sandong region in China than non-Sandong and northen China to Busan area. The results of the factor analysis at Guducsan indicates that factor 1 was anthropogenic source effects such as automobile emissions and industrial combustion processes, factor 2 was marine sources such as sea salts from sea, and factor 3 was soil component sources.

부산지역의 입자상 대기오염물질의 농도특성에 관한 연구 (A Study on the Characteristics of Concentrations of Atmospheric Aerosols in Pusan)

  • 최금찬;유수영;전보경
    • 한국환경보건학회지
    • /
    • 제26권2호
    • /
    • pp.41-48
    • /
    • 2000
  • This study has been carried out to determine the seasonal characteristics of concentration of various ionic (CI-, NO3-, SO42-, Na+, NH+, K+, Ca2+) and heavy metallic (Pb, Mn, Cu, Ni) species in Pusan from August 1997 to April 1998. The concentrations of CI-, Na+, K+ were higher during summer with 2.98 ${\mu}{\textrm}{m}$/㎥. Seasonal variation of total concentration of but the concentration of NH4+ was higher during winter with 2.46${\mu}{\textrm}{m}$/㎥. Seasonal variation of total concentration of heavy metals(Pb, Cu, Mn, Ni) were 186.0 ng/㎥ in summer, 222.6 ng/㎥ in autumn, and 135.83 ng/㎥ in winter. Over the seasons inspected, the concentration of Mn was higher in coarse particles than fine particles and concentration of Ni was higher in fine particles than coarse particles. during yellow sand period, the concentration of TSP was increased about two times than that of other period. SO42-, Ca2+ concentrations were higher than other ionic components because of soil particles. The concentration of Ni showed 94.62ng/㎥ was increased about 4~5 times than other period. Principal component of the yellow sand, SO42-, Ca2+ could be discreased by rainfall and washout effect of atmospheric aerosol was higher in coarse particles than fine particles. Results from PCA(principal component analysis) showed that major pollutant was NaCl by seasalt particulate and (NH4)2SO4.

  • PDF

부산 지역 연무 발생일의 미세먼지 농도와 사례별 특성 (Characteristics of Fine Particle Concentration and Case during Haze Days in Busan)

  • 전병일
    • 한국환경과학회지
    • /
    • 제26권6호
    • /
    • pp.751-765
    • /
    • 2017
  • This research investigates the characteristics of meteorological variation and fine particles ($PM_{10}$ and $PM_{2.5}$) for case related to the haze occurrence (Asian dust, long range transport, stationary) in Busan. Haze occurrence day was 559 days for 20 years (from 1996 to 2015), haze occurrence frequency was 82 days (14.7%) in March, followed by 67 days (12.0%) in February and 56 days (10.0%) in May. Asian dust occurred most frequently in spring and least in winter, whereas haze occurrence frequency was 31.5% in spring, 29.7% in winter, 21.1% in fall, and 17.7% in summer. $PM_{10}$ concentration was highest in the occurrence of Asian dust, followed by haze and haze + mist, whereas $PM_{2.5}$ concentration was highest in the occurrence of haze. These results indicate that understanding the relation between meteorological phenomena and fine particle concentration can provide insight into establishing a strategy to control urban air quality.