• Title/Summary/Keyword: Concentrated control system

Search Result 189, Processing Time 0.025 seconds

Anti-sway System for Automatic Container Terminal (자동화 컨테이너 터미널용 Anti-Sway 시스템)

  • 박경택;박찬훈;김두형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.428-431
    • /
    • 2002
  • Yard cranes are very useful equipments for handling of heavy containers. But rope-driven yard cranes must have a little of sway and skew motion because ropes are passive mechanical device. So many researches have been concentrated on anti-sway algorithm controlling trolley speed. But control algorithm of trolley speed is not practical in windy weather. In this paper, we are going to propose a new structure for anti-sway. This structure uses aux. ropes. The control strategy with auxiliary rope is very useful to sway control of yard crane because rope length is shorter than quay-side container cranes. In this paper, we derive equations of motion of trolley system which have anti-sway controller to use auxiliary rope. And main schemes are introduced and explained briefly.

  • PDF

An Analysis Measure for Cybersecurity linked Threat against Diverse Protection Systems (다양성보호계통 사이버보안 연계 위협 분석 방안)

  • Jung, Sungmin;Kim, Taekyung
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.17 no.1
    • /
    • pp.35-44
    • /
    • 2021
  • With the development of information technology, the cybersecurity threat continues as digital-related technologies are applied to the instrumentation and control system of nuclear power plants. The malfunction of the instrumentation and control system can cause economic damage due to shutdown, and furthermore, it can lead to national disasters such as radioactive emissions, so countering cybersecurity threats is an important issue. In general, the study of cybersecurity in instrumentation and control systems is concentrated on safety systems, and diverse protection systems perform protection and reactor shutdown functions, leading to reactor shutdown or, in the worst case, non-stop situations. To accurately analyze cyber threats in the diverse protection system, its linked facilities should be analyzed together. Risk analysis should be conducted by analyzing the potential impact of inter-facility cyberattacks on related facilities and the impact of cybersecurity on each configuration module of the diverse protection system. In this paper, we analyze the linkage of the diverse protection system and discuss the cybersecurity linkage threat by analyzing the availability of equipment, the cyber threat impact of the linked equipment, and the configuration module's cybersecurity vulnerability.

Manufacture of Gouda Cheese from the Concentrated Milk by the Use of Ultrafiltration (Ultrafiltration을 이용한 Gouda Cheese의 제조)

  • Lee, Yong-Lim;Kim, Sang-Pil;Park, Hee-Kyung;Heo, Tae-Ryeon
    • Microbiology and Biotechnology Letters
    • /
    • v.22 no.1
    • /
    • pp.99-105
    • /
    • 1994
  • In this study we compared traditional cheesemaking process with the process utilizing ultrafiltration(UF) system. The whole milk retentates were prepared by ultrafiltration to volume concentration ratio(VCR) of 2.00:1, 2.25:1 and 2.50:1. Along with the untreated whole milk, there were studies in terms of the change of pH, titratable acidity and Soxhlet-Henkel($\circ $SH) value by mesophilic lactic starter and curd formation by rennet during Gouda cheese manufacture. Due to the increase of buffering effect titratable acidity and $\circ $SH value increased with the higher concentration ratio. When inoculated with the same volume of mesophilic lactic starter, less pH change occurred in UF retentates than in control milk. When added 0.0025% rennet, UF retentates coagulated 16~ 17 minutes ealier then the control milk. Gouda cheese yield from raw milk and UF retentates was 12.5~13.1% equally, but yield efficiency of UF retentate cheese was slightly higher than that of the raw milk cheese. Quantity of whey from retentate cheese was inversely related to VCR. But whey from retentate cheese contained higher percentage of amjor components than that from control milk cheese. In early ripening, the concentrations of lactose and soluble nitrogen compound were higher in retentate cheeses. Lactose content of control milk cheese was 3.49% and that of 2.00:1. 2.25:1, 2.50:1 VCR retentate was 3.77%, 4.89%, 7.03%, respectively. Thus, the more concentrated cheese contained a higher amount of lactose and all the lactose was hyerolyzed durion 35-day ripenion period. Soluble nitrogen compound of control milk cheese was 1.22% and that of UF cheeses was 1.82~2.06%. After 20-day ripening, soluble nitrogen compound increased starply in UF cheese.

  • PDF

Parameters Estimation Characteristics of Five-Phase Squirrel-Cage Induction Motor within Over Current Load (과전류 부하에서 5상 농형 유도전동기의 정수 특성)

  • Kim, Min-Huei
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.7
    • /
    • pp.38-46
    • /
    • 2015
  • This paper propose a variable parameter estimations for variable over current load of five-phase squirrel-cage induction motor(IM) to servo control system. In order to high performance control of AC motor using a field oriented control(FOC) and direct torque control(DTC) algorithm, there are required precise motor parameters for slip calculation, flux observer, controller gain, torque command of current components, rotor position, speed estimation, and so on. We are suggest a analyzed estimation results of the motor parameters that developing five-phase squirrel-cage IM have a stator of concentrated winding for experimental within variable over current load at rated input frequency. There are results of stator winding measurement, no-load test, locked-rotor test, variable over current load test, and estimated parameters of equivalent circuits using manufactured experimental apparatus by IEEE Standard Test Procedure for Polyphase Induction Motors and Generators 112-2004.

Parameters Estimation of Five-Phase Squirrel-Cage Induction Motor in Changing Variable Frequency (주파수 변화에 따른 5상 농형 유도전동기의 정수 추정)

  • Kim, Min-Huei
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.241-247
    • /
    • 2014
  • This paper propose a variable parameter estimations of five-phase squirrel-cage induction motor(IM) for speed control system. In order to high performance control of AC motor using a field oriented control(FOC) and direct torque control(DTC) algorithm, there are required precise motor parameters for slip calculation, flux observer, controller gain, rotor position, speed estimation, and so on. We are suggest a analyzed estimation results of the motor parameters that developing five-phase squirrel-cage IM have a stator of concentrated winding for experimental of variable input power frequency. There are results of stator winding test, no-load test, locked-rotor test, variable actual load test, and estimated parameters of equivalent circuits using manufactured experimental apparatus by IEEE Standard Test Procedure for Polyphase Induction Motors and Generators 112-2004.

(A study on the fuel economy in the vehicle using variable cylinder system) (가변실린더시스템을 이용한 차량의 연비향상에 관한 연구)

  • 이태표;김종부;박준훈
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.1
    • /
    • pp.71-76
    • /
    • 2002
  • Because the driving time is increased under the low speed by rapidly increasing of vehicles, this paper is presented a new ignition control system for improvement the fuel economy, which only some of cylinders are using under the idle status or low speed and preserving the engine rpm. is applicable to effective in fuel economy. An actual hardware was made to prove this new control system. The developed variable cylinder engine concentrated the heat neat the cylinders in idle status or low speed, so there was a problem in re-ignition. It was the reason of a lot of exhaust gas, high fuel consumption and instability of engine revolution. In this paper, in order to solve above problem to show the improvement fuel economy using the new ignition control system and valve opening period at idle status of low speed.

Comparative Study on 220V AC Feed System and 300V DC Feed System for Internet Data Centers

  • Kim, Hyo-Sung
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.157-163
    • /
    • 2012
  • Internet Data Centers (IDCs), which are essential facilities in the modern IT industry, typically have scores of MW of concentrated electric loads. The provision of an Uninterruptible Power Supply (UPS) is necessary for the power feed system of IDCs owing to the need for stable power. Thus, conventional IDC AC power feed systems have three cascaded power conversion stages, (AC-DC), (DC-AC), and (AC-DC), resulting in a very low conversion efficiency. In comparison, DC power feed systems require only a single power conversion stage (AC-DC) to supply AC main power to DC server loads, resulting in comparatively high conversion efficiency and reliability [4-11]. This paper compares the efficiencies of a 220V AC power feed system with those of a 300V DC power feed system under equal load conditions, as established by the Mok-Dong IDC of Korea Telecom Co. Ltd. (KT). Experimental results show that the total operation efficiency of the 300V DC power feed system is approximately 15% higher than that of the 220V AC power feed system.

Study on Performance Optimization of Clutch Master Cylinder (클러치 마스터 실린더의 성능최적화에 관한 연구)

  • Lee, Chun-Kon;Lee, Chang-Heon;Byun, Jae-Hyuk;Lee, Jae-Yul;Ro, Seung-Hoon;Lee, Jong-Hyung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.11 no.4
    • /
    • pp.165-170
    • /
    • 2008
  • The demand for the lighter parts compels new composite materials composed of nylon66 and glass fiber to be used for the clutch control hydraulic system to achieve the low cost, light weight and the simple production process. In this paper the feasibility of using those composite materials for the clutch system has been investigated. And the efforts have been concentrated to enhance the durability and the credibility of the system. The procedure has been developed to design the clutch system to satisfy the categories mentioned above and to analyze the durability of the system and to setup a simulation program for the realistic driving situations.

  • PDF

Comparative Study on AC and DC Feed System for Internet Data Center (인터넷데이터센터의 교류, 직류급전시스템 비교 분석)

  • Kim, Du-Hwan;Kim, Hyo-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.27-33
    • /
    • 2012
  • Internet Data Centers (IDC), as essential facilities for modern IT industry, typically have scores of MW of concentrated electric loads. Uninterruptible Power Supplies (UPS) are necessary for the power feed system of IDCs because of stable power requirement. Thus, conventional AC power feed systems of IDCs have three cascaded power conversion stages such as (AC-DC), (DC-AC), and (AC-DC), which results in very low conversion efficiency. On the contrary, DC power feed systems need just a single power conversion stage (AC-DC) supplying AC mains power to DC server loads, which gives comparatively high conversion efficiency and reliability. This paper compares the efficiencies between 220V AC power feed system and 300V DC power feed system on equal load conditions which were established in Mok-Dong IDC of Korea Telecom company (KT). Experimental results show that the total operation efficiency of the 300V DC power feed system is around 15% higher than that of the 220V AC power feed system.

Power Quality Analysis of Wind Farms interconnected in Jeju System during HVDC Overhaul (HVDC Overhaul 기간 중 제주계통에 연계된 풍력발전의 전력품질 분석)

  • Chae, Woo-Kyu;Yoon, Gi-Gab;Cho, Seong-Soo;Jung, Won-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.1946-1953
    • /
    • 2008
  • Power system of Jeju is interconnected to the mainland using HVDC and that is also interconnected to three wind farms. It will be difficult to control of Jeju power system if HVDC is disconnected or HVDC is overhauled under large scale wind farms interconnected. We measured and analysed the power quality of two substation and two wind farms to assess that wind farms have an effect on Jeju system during the HVDC overhaul last May. We concentrated on the power quality like frequency, voltage variation, voltage harmonics, current harmonics, flicker. We can found that the frequency of Jeju system is very unstable during overhaul, so the frequency of Jeju system can be variated easily by wind farm's rapid output power variation. There are some benefits and weak points in power quality between two wind farms because each wind farm is consist of different wind turbines.