• 제목/요약/키워드: Computer-aided design/computer-aided manufacturing

검색결과 403건 처리시간 0.025초

Trueness of 3D printed partial denture frameworks: build orientations and support structure density parameters

  • Hussein, Mostafa Omran;Hussein, Lamis Ahmed
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권3호
    • /
    • pp.150-161
    • /
    • 2022
  • PURPOSE. The purpose of the study was to assess the influence of build orientations and density of support structures on the trueness of the 3D printed removable partial denture (RPD) frameworks. MATERIALS AND METHODS. A maxillary Kennedy class III and mandibular class I casts were 3D scanned and used to design and produce two 3D virtual models of RPD frameworks. Using digital light processing (DLP) 3D printing, 47 RPD frameworks were fabricated at 3 different build orientations (100, 135 and 150-degree angles) and 2 support structure densities. All frameworks were scanned and 3D compared to the original virtual RPD models by metrology software to check 3D deviations quantitatively and qualitatively. The accuracy data were statistically analyzed using one-way ANOVA for build orientation comparison and independent sample t-test for structure density comparison at (α = .05). Points study analysis targeting RPD components and representative color maps were also studied. RESULTS. The build orientation of 135-degree angle of the maxillary frameworks showed the lowest deviation at the clasp arms of tooth 26 of the 135-degree angle group. The mandibular frameworks with 150-degree angle build orientation showed the least deviation at the rest on tooth 44 and the arm of the I-bar clasp of tooth 45. No significant difference was seen between different support structure densities. CONCLUSION. Build orientation had an influence on the accuracy of the frameworks, especially at a 135-degree angle of maxillary design and 150-degree of mandibular design. The difference in the support's density structure revealed no considerable effect on the accuracy.

사출성형공정에서 CAE 기반 품질 데이터와 실험 데이터의 통합 학습을 통한 인공지능 품질 예측 모델 구축에 대한 연구 (A study on the construction of the quality prediction model by artificial neural intelligence through integrated learning of CAE-based data and experimental data in the injection molding process)

  • 이준한;김종선
    • Design & Manufacturing
    • /
    • 제15권4호
    • /
    • pp.24-31
    • /
    • 2021
  • In this study, an artificial neural network model was constructed to convert CAE analysis data into similar experimental data. In the analysis and experiment, the injection molding data for 50 conditions were acquired through the design of experiment and random selection method. The injection molding conditions and the weight, height, and diameter of the product derived from CAE results were used as the input parameters for learning of the convert model. Also the product qualities of experimental results were used as the output parameters for learning of the convert model. The accuracy of the convert model showed RMSE values of 0.06g, 0.03mm, and 0.03mm in weight, height, and diameter, respectively. As the next step, additional randomly selected conditions were created and CAE analysis was performed. Then, the additional CAE analysis data were converted to similar experimental data through the conversion model. An artificial neural network model was constructed to predict the quality of injection molded product by using converted similar experimental data and injection molding experiment data. The injection molding conditions were used as input parameters for learning of the predicted model and weight, height, and diameter of the product were used as output parameters for learning. As a result of evaluating the performance of the prediction model, the predicted weight, height, and diameter showed RMSE values of 0.11g, 0.03mm, and 0.05mm and in terms of quality criteria of the target product, all of them showed accurate results satisfying the criteria range.

시뮬레이션을 활용한 폰카메라 렌즈모듈 부품용 사출금형개발 (A Simulation Study on the Development of Injection Mold for the Parts of Phone Camera Lens Module)

  • 김혜정;김재훈;김영규;송준엽;문덕희
    • 한국시뮬레이션학회논문지
    • /
    • 제22권4호
    • /
    • pp.83-92
    • /
    • 2013
  • 휴대폰 시장의 확산으로 인하여 휴대폰에 장착되는 카메라 렌즈모듈의 수요도 급증하고 있다. 렌즈모듈 부품의 경우 해상도의 증가에 따른 사출공정의 품질보증과 원가절감이라는 두 가지 목표를 달성해야 한다. 따라서 본 논문에서는 더블카세트 방식의 금형구조를 이용하여 경통과 쉴드 두 종류의 제품을 개발하기 위해 시뮬레이션을 활용한 사례를 소개한다. 개발과정에서 두 종류의 시뮬레이션 기술을 활용하였는데, 첫 번째는 금형 설계단계에서 사출품의 성형성을 분석하기 위한 시뮬레이션(일명 Computer Aided Engineering)을 Mold Flow$^{TM}$를 사용하여 수행하였고, 두 번째는 사출기에 금형을 장착한 후 제품이 사출되어 취출하는 동작을 분석하기 위한 동작 시뮬레이션을 DPM Assembly$^{TM}$를 이용하여 수행하였다. 개발 결과 기존 방식에 비해 제품의 생산성이 300% 이상 증가하는 효과를 얻었다.

3 차원 프린팅 기술로 제작된 조직공학용 3 차원 구조체 (Three-Dimensional Printed 3D Structure for Tissue Engineering)

  • 박정훈;장진아;조동우
    • 대한기계학회논문집B
    • /
    • 제38권10호
    • /
    • pp.817-829
    • /
    • 2014
  • 조직공학 분야에서의 3 차원 구조체는 세포의 성장과 분화를 유도하기 위한 미세 환경을 제공하고, 재생하고자 하는 조직의 형태를 유지할 수 있도록 지탱해 주는 역할을 수행한다. 현재까지 다양한 생체재료 및 이의 가공 기법들이 이러한 3 차원 구조체를 제작하는데 적용되고 있다. 특히, 3 차원 프린팅 기술은 다양한 재료를 이용하여 원하는 외부 형상과 내부 구조를 제작할 수 있기 때문에 오늘날 조직공학 분야에 많이 이용되고 있고, 이 기술을 통해 새로운 조직공학적 접근 방법도 시도되고 있다. 본 논문에서는, 현재 조직공학 분야에 적용되고 있는 3 차원 프린팅 기술과, 이를 통해 제작된 기능성 인공지지체 및 세포 프린팅 구조체, 그리고 이의 다양한 조직공학적 적용에 대해서 서술하고자 한다.

In vivo wear determination of novel CAD/CAM ceramic crowns by using 3D alignment

  • Aladag, Akin;Oguz, Didem;Comlekoglu, Muharrem Erhan;Akan, Ender
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권2호
    • /
    • pp.120-127
    • /
    • 2019
  • PURPOSE. To determine wear amount of single molar crowns, made from four different restoratives, and opposing natural teeth through computerized fabrication techniques using 3D image alignment. MATERIALS AND METHODS. A total of 24 single crowns (N = 24 patients, age range: 18 - 50) were made from lithium disilicate (IPS E-max CAD), lithium silicate and zirconia based (Vita Suprinity CAD), resin matrix ceramic material (Cerasmart, GC), and dual matrix (Vita Enamic CAD) blocks. After digital impressions (Cerec 3D Bluecam, DentsplySirona), the crowns were designed and manufactured (Cerec 3, DentsplySirona). A dualcuring resin cement was used for cementation (Variolink Esthetic DC, Ivoclar). Then, measurement and recording of crowns and the opposing enamel surfaces with the intraoral scanner were made as well as at the third and sixth month follow-ups. All measurements were superimposed with a software (David-Laserscanner, V3.10.4). Volume loss due to wear was calculated from baseline to follow-up periods with Siemens Unigraphics NX 10 software. Statistical analysis was accomplished by Repeated Measures for ANOVA (SPSS 21) at = .05 significance level. RESULTS. After 6 months, insignificant differences of the glass matrix and resin matrix materials for restoration/enamel wear were observed (P>.05). While there were no significant differences between the glass matrix groups (P>.05), significant differences between the resin matrix group materials (P<.05) were obtained. Although Cerasmart and Enamic were both resin matrix based, they exhibited different wear characteristics. CONCLUSION. Glass matrix materials showed less wear both on their own and opposing enamel surfaces than resin matrix ceramic materials.

치료의치와 CAD-CAM 기술을 이용한 불안정한 하악위를 가진 완전 무치악 환자의 치료 증례 (Full mouth rehabilitation in edentulous patient with unstable mandibular position using flat table treatment dentures and CAD-CAM technology)

  • 김유연;이영후;홍성진;백장현;노관태;김형섭;권긍록;배아란
    • 대한치과보철학회지
    • /
    • 제60권4호
    • /
    • pp.330-338
    • /
    • 2022
  • 과두 골절 및 형태 이상으로 인해 불안정한 하악 운동 및 비정상적인 안모를 갖는 무치악 환자의 경우 환자의 안정된 하악위를 찾는 것이 중요하다. 본 증례에서는 flat table 치료의치를 이용하여 환자의 안모개선, 하악 운동의 안정, 의치의 안정성이 향상시켰다. 또한 flat table 치료의치의 수직고경 및 구순 지지도를 유지하고자 CAD-CAM 기술을 이용하여 제작한 총의치 수복을 통해 환자의 불편감을 개선하는 양호한 결과를 얻었기에 이를 보고하는 바이다.

Microbiological cleaning and disinfection efficacy of a three-stage ultrasonic processing protocol for CAD-CAM implant abutments

  • Gehrke, Peter;Riebe, Oliver;Fischer, Carsten;Weinhold, Octavio;Dhom, Gunter;Sader, Robert;Weigl, Paul
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권5호
    • /
    • pp.273-284
    • /
    • 2022
  • PURPOSE. Computer-aided design and manufacturing (CAD-CAM) of implant abutments has been shown to result in surface contamination from site-specific milling and fabrication processes. If not removed, these contaminants can have a potentially adverse effect and may trigger inflammatory responses of the peri-implant tissues. The aim of the present study was to evaluate the bacterial disinfection and cleaning efficacy of ultrasonic reprocessing in approved disinfectants to reduce the microbial load of CAD-CAM abutments. MATERIALS AND METHODS. Four different types of custom implant abutments (total N = 32) with eight specimens in each test group (type I to IV) were CAD-CAM manufactured. In two separate contamination experiments, specimens were contaminated with heparinized sheep blood alone and with heparinized sheep blood and the test bacterium Enterococcus faecium. Abutments in the test group were processed according to a three-stage ultrasonic protocol and assessed qualitatively and quantitatively by determination of residual protein. Ultrasonicated specimens contaminated with sheep blood and E. faecium were additionally eluted and the dilutions were incubated on agar plates for seven days. The determined bacterial counts were expressed as colony-forming units (CFU). RESULTS. Ultrasonic reprocessing resulted in a substantial decrease in residual bacterial protein to less than 80 ㎍ and a reduction in microbiota of more than 7 log levels of CFU for all abutment types, exceeding the effect required for disinfection. CONCLUSION. A three-stage ultrasonic cleaning and disinfection protocol results in effective bacterial decontamination. The procedure is reproducible and complies with the standardized reprocessing and disinfection specifications for one- or two-piece CAD-CAM implant abutments.

서지컬 가이드를 이용한 하악 임플란트 피개의치 수복 증례 (Oral rehabilitation of edentulous patient with mandibular implant overdenture using surgical guide)

  • 이동환;류재준
    • 대한치과보철학회지
    • /
    • 제60권4호
    • /
    • pp.339-346
    • /
    • 2022
  • 전통적인 총의치와 비교했을 때 하악 임플란트 피개의치는 2개의 임플란트로도 좋은 지지와 유지를 얻을 수 있다는 장점이 있다. 2개의 임플란트를 이용하여 하악 임플란트 피개의치를 제작할 때는 정확한 위치에 임플란트를 식립하는 것이 중요하다. 2개의 임플란트를 교합평면에 수직 방향으로, 견치 자리에 서로 평행하게 식립해야 피개의치의 장기적인 예후에 좋다. 하지만 무치악 환자에서 2개의 임플란트를 올바른 위치에 식립하는 것은 어려운 일이며, 이 때 서지컬 가이드를 이용한다면 보철적으로 유리한 위치에 임플란트를 식립하는데 도움을 받을 수 있다. 본 증례는 57세 남환으로 치주질환으로 인해 상, 하악의 모든 치아가 발거된 상태로 본원에 내원했다. 이에 상악은 전통적인 총의치, 하악은 2개의 임플란트를 이용한 임플란트 피개의치로 수복하여 기능 및 심미적으로 만족스러운 결과를 얻었으므로 이를 보고하고자 한다.

835 MHz 및 1,800 MHz 대역에서 인체의 전기적 특성을 가지는 한국인 손 모양의 팬텀 제작 (Manufacturing of a Korean Hand Phantom with Human Electrical Properties at 835 MHz and 1,800 MHz Bands)

  • 최동근;김윤명;최재훈
    • 한국전자파학회논문지
    • /
    • 제24권5호
    • /
    • pp.534-540
    • /
    • 2013
  • 휴대전화의 이용이 증가하면서, 손에 미치는 전자파의 영향에 대한 관심이 증가하고 있다. IEC TC106에서도 휴대전화의 전자파 인체 노출량 평가 방법 표준에 손 영향을 반영하기 위하여 국제적인 교류 연구가 활발하게 진행되고 있다. 현재 상용화된 손 팬텀은 평균 서양인 손을 이용하고 있을 뿐만 아니라, 한 가지 형태의 파지(把持)만 가능하기 때문에, SAR 측정 결과에 대한 분석에 제한이 많은 실정이다. 손의 영향을 제대로 분석하기 위해서는 다양한 형태의 파지가 가능한 손 팬텀이 필요하다. 또한, 국내 환경에 맞는 손 팬텀의 개발이 필수적이다. 본 논문에서는 다양한 형태의 파지가 가능한 835 MHz 대역과 1,800 MHz 대역의 한국인의 젤리형 손 팬텀을 제작하였다. 제작된 손 팬텀의 전기적 특성은 비유전율과 도전율이 CTIA(미국이동통신산업협회) 권고 기준 값의 ${\pm}10%$이내로서, CTIA에서 제시하는 오차 기준(${\pm}20%$)보다 더 우수한 특성을 나타냈다. 또한, 손 팬텀의 3D CAD(3차원 컴퓨터 이용 설계) 파일을 개발하여 손에 의한 SAR 영향 분석을 위한 시뮬레이션에서 활용할 수 있도록 하였다. 본 연구를 통해 제작된 젤리형 손 팬텀과 3D 파일은 휴대 전화의 손 영향에 대한 연구에 유용하게 이용될 수 있을 것으로 본다.

비정형 구조물의 시공성을 고려한 3차원 디지털 설계 최적화 프로세스 (3D Digital Design Optimization Process Considering Constructability of Freeform Structure)

  • 류한국
    • 한국건설관리학회논문집
    • /
    • 제14권5호
    • /
    • pp.35-43
    • /
    • 2013
  • 최근 상당기간과 공사비를 최소화할 수 있는 비정형 건축물의 설계와 시공이 새로운 기술로 구현되고 있다. 이는 비정형 건축물의 최적화 설계와 부재화를 통한 공장 생산 시스템과 현장 조립 및 설치 기술로 가능하다. 비정형 건축물의 구현을 위한 연구가 진행되어 왔으나 여전히 비정형 건축물 시공은 설계오류와 시공자의 도면이해 부족, 시공경험 및 공법의 부재 등으로 인하여 시공 품질과 공기, 공사비 증가 등의 잠재적 리스크를 포함하고 있다. 비정형 건축물의 시공품질 향상과 공기단축 및 시공비 상승의 문제점을 해결하기 위한 3D 디지털 설계와 제작 기술을 적용하는 것이 중요하다. 이에 본 연구는 비정형 구조물의 시공성을 고려한 3차원 디지털 설계 최적화 프로세스를 제안한다. 궁극적으로 본 연구는 비정형 구조물의 구조검토, CNC(Computerized Numerical Control) 가공에 의한 부재의 정밀제작, 설치, 시공의 오차관리로 최적 시공의 근간이 되는 비정형 건축물 외피 시스템 구현을 위한 최적화 설계 프로세스를 제시한다.본 연구는 비정형 건축물을 구현한 사례를 살펴보고 디지털 설계 프로세스와 적용 프로그램을 살펴본다. 비정형 건축물의 설계도의 3D 디지털 데이터 구축과 디지털 최적화 구현 사례로 4대강 대표 물문화관(The ARC)을 중심으로 설계단계에서 적용된 최적화 기법을 순차적으로 분석하여 비정형 건축물의 3차원 좌표제어에 대한 방법론을 제시한다.