• Title/Summary/Keyword: Computer-aided design/computer-aided manufacturing

Search Result 410, Processing Time 0.027 seconds

Full mouth rehabilitation utilizing computer guided implant surgery and CAD/CAM (Computer guided implant surgery와 CAD/CAM을 활용한 전악 수복 증례)

  • Kim, Sungjin;Han, Jung-Suk;Kim, Sung-Hun;Yoon, Hyung-In;Yeo, In-Sung Luke
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.57-65
    • /
    • 2019
  • Computer aided design and manufacturing and implant surgery using a guide template improve restoration-driven implant treatment procedures. This case utilized those digital technologies to make definitive prostheses for a patient. According to the work flow of digital dentistry, cone beam computed tomography established the treatment plan, which was followed to make the guide template for implant placement. The template guided the implants to be installed as planned. The customized abutments and surveyed fixed restorations were digitally designed and made. The metal framework of the removable partial denture was cast from resin pattern using an additive manufacturing technique, and the artificial resin teeth were replaced with the zirconia onlays for occlusal stability. These full mouth rehabilitation procedures provided functionally and aesthetically satisfactory results for the patient.

Single-tooth dento-osseous osteotomy with a computer-aided design/computer-aided manufacturing surgical guide

  • Kang, Sang-Hoon;Kim, Moon-Key;Lee, Ji-Yeon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.2
    • /
    • pp.127-130
    • /
    • 2016
  • This clinical note introduces a method to assist surgeons in performing single-tooth dento-osseous osteotomy. For use in this method, a surgical guide was manufactured using computer-aided design/computer-aided manufacturing technology and was based on preoperative surgical simulation data. This method was highly conducive to successful single-tooth dento-osseous segmental osteotomy.

Fabrication of a custom polyetherketoneketone post-and-core with digital technology

  • Ju-Hyoung Lee;Gyu-Heon Lee
    • Journal of Technologic Dentistry
    • /
    • v.46 no.1
    • /
    • pp.15-19
    • /
    • 2024
  • An ideal post material should have physical properties similar to those of dentin. Post materials with high elastic moduli may cause root fractures. This clinical report describes the treatment of a severely damaged tooth using a recently introduced material. Polyetherketoneketone (PEKK) is a semicrystalline high-performance thermoplastic polymer. PEKK is a promising material for custom post-and-core fabrication because of its elasticity close to that of dentin, good shock absorbance, machinability, and low cost. A laboratory scanner was used to digitize the conventional impression of a severely damaged maxillary right first molar. A custom PEKK post-and-core was designed and milled using computer-aided design and computer-aided manufacturing technology. Using the proposed technique, a custom PEKK post-and-core was fabricated accurately and human error was reduced. Restoration was luted with resin cement. Custom PEKK post-and-core restorations are a viable alternative for treating severely damaged teeth.

Computer-aided design/computer-aided manufacturing of hydroxyapatite scaffolds for bone reconstruction in jawbone atrophy: a systematic review and case report

  • Garagiola, Umberto;Grigolato, Roberto;Soldo, Rossano;Bacchini, Marco;Bassi, Gianluca;Roncucci, Rachele;De Nardi, Sandro
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.2.1-2.9
    • /
    • 2016
  • Background: We reviewed the biological and mechanical properties of porous hydroxyapatite (HA) compared to other synthetic materials. Computer-aided design/computer-aided manufacturing (CAD/CAM) was also evaluated to estimate its efficacy with clinical and radiological assessments. Method: A systematic search of the electronic literature database of the National Library of Medicine (PubMed-MEDLINE) was performed for articles published in English between January 1985 and September 2013. The inclusion criteria were (1) histological evaluation of the biocompatibility and osteoconductivity of porous HA in vivo and in vitro, (2) evaluation of the mechanical properties of HA in relation to its porosity, (3) comparison of the biological and mechanical properties between several biomaterials, and (4) clinical and radiological evaluation of the precision of CAD/CAM techniques. Results: HA had excellent osteoconductivity and biocompatibility in vitro and in vivo compared to other biomaterials. HA grafts are suitable for milling and finishing, depending on the design. In computed tomography, porous HA is a more resorbable and more osteoconductive material than dense HA; however, its strength decreases exponentially with an increase in porosity. Conclusions: Mechanical tests showed that HA scaffolds with pore diameters ranging from 400 to $1200{\mu}m$ had compressive moduli and strength within the range of the human craniofacial trabecular bone. In conclusion, using CAD/CAM techniques for preparing HA scaffolds may increase graft stability and reduce surgical operating time.

Implant-assisted full denture using digital guide: a case report (무치악 환자에서 디지털 가이드를 이용한 임플란트 수복증례)

  • Kim, Wook Tae
    • Journal of Technologic Dentistry
    • /
    • v.43 no.4
    • /
    • pp.202-209
    • /
    • 2021
  • By classifying temporary denture production for surgical guides, digital guide-based surgery, and final prosthesis production, the problems of each process were assessed in advance and the factors that could be improved were confirmed in this study. The manufacturing process of fusion dental prosthesis uses virtual programs and computed tomography images to manufacture devices using the latest technologies of computer-aided design/computer-aided manufacturing and three-dimensional printing, which enables implants to be placed in the desired location in advance. Moreover, implant placement is not dependent on the skill and condition of the dentist, and because it uses a computer system, it can always be performed at a constant and optimal position. This can reduce the remanufacturing rate compared with the general method, shorten the treatment period, and eliminate patient discomfort. Unlike the traditional method of using impression materials and plaster models, digital fusion dental prostheses would be evaluated as a technology for producing prosthesis through professional design technology and communication.

IMPLEMENTATION OF PRODUCT DATA MANAGEMENT SYSTEM FOR DESIGN OF BRIDGE STRUCTURES

  • Jin-Suk Kang;Seung-Ho Jung;Yoon-Bum Lee;Kwang-Myong Lee
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1318-1323
    • /
    • 2009
  • In recent years, dramatic advances in information technology have motivated the construction industry to improve its productivity. Computer-based information technology includes Computer-Aided Design (CAD), Computer-Aided Engineering (CAE), Computer-Aided Manufacturing (CAM), Enterprise Resource Planning (ERP), Digital Mock-Up (DMU) and Product Data Management (PDM). Most construction industries are trying to apply these technologies for quality improvement, reduction of construction time and cost. PDM is very useful for managing data and process related to product design and manufacturing. PDM system has various functions such as drawing and engineering document management, product structure and structure modification management, part classification management, workflow management, and project management. In this paper, PDM system was applied to the design of steel-concrete composite girder bridge. To make a practical guidance for PDM implementation to bridge design, the procedure for its implementation was presented. Consequently, this paper could be useful to enhance the efficiency of bridge design.

  • PDF

Genioplasty using a simple CAD/CAM (computer-aided design and computer-aided manufacturing) surgical guide

  • Lim, Se-Ho;Kim, Moon-Key;Kang, Sang-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.44.1-44.6
    • /
    • 2015
  • Background: The present study introduces the design and fabrication of a simple surgical guide with which to perform genioplasty. Methods: A three-dimensional reconstruction of the patient's cranio-maxilla region was built, with a dentofacial skeletal model, then derived from CT DICOM data. A surgical simulation was performed on the maxilla and mandible, using three-dimensional cephalometry. We then simulated a full genioplasty, in silico, using the three-dimensional (3D) model of the mandible, according to the final surgical treatment plan. The simulation allowed us to design a surgical guide for genioplasty, which was then computer-rendered and 3D-printed. The manufactured surgical device was ultimately used in an actual genioplasty to guide the osteotomy and to move the cut bone segment to the intended location. Results: We successfully performed the osteotomy, as planned during a genioplasty, using the computer-aided design and computer-aided manufacturing (CAD/CAM) surgical guide that we initially designed and tested using simulated surgery. Conclusions: The surgical guide that we developed proved to be a simple and practical tool with which to assist the surgeon in accurately cutting and removing bone segments, during a genioplasty surgery, as preoperatively planned during 3D surgical simulations.

A Study on Weave Design of Supplementary Warp using Computer-Aided Weaving System (CAW(Computer-Aided Weaving) 시스템을 활용한 Supplementary Warp의 직조디자인 연구)

  • Song, Ha-Young
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.12 no.3
    • /
    • pp.43-55
    • /
    • 2010
  • The major advantages to use CAD System are that it reduce time and effort to manufacture products, and also can demonstrate the condition of the final product prior to the actual manufacturing process of the selected design using the simulation programs in CAD system. Specially in weave design, for use as Computer-Aided Weaving system, the complicated Dobby weave can figured out easily through calculating the complex weave plans of multi shafts. As to one of dobby weave structures, Supplementary warp is the warp threads which are in addition to the regular warps of the woven fabrics, and used for decorating the band or expressing some patterns. The purpose of this study is to research the weave design of Supplementary warp using Computer-Aided Weaving system, which is dobby weave design program of Weave Point. For performing this design study, it was researched the classified woven fabrics depending upon weaving processing, Computer-Aided Weaving system, and the characteristic of Supplementary warp fabrics. On the basis of the theoretical research, Supplementary warp was worked for the 24-shafts AVL computer dobby loom that applied to the various patterned images. The design work was done by Weave Point program of dobby weave, and simulated to fabrics before woven into the computer dobby loom. To see the visual images of fashion items, these simulated bobby fabrics were processed by three-dimension modeling through YoungWoo CNI CAD system. All the patterns of the Supplementary warp in this study could be applied for decorating the fashion clothing and accessories.

  • PDF

The factors caused errors in the production process of CAD/CAM prosthesis based on experience (임상가를 위한 특집 1 - CAD/CAM 보철물의 제작 과정에서 오류가 발생할 수 있는 요소들에 대한 경험적 고찰)

  • Huh, Jung-Bo;Shim, June-Sung
    • The Journal of the Korean dental association
    • /
    • v.52 no.6
    • /
    • pp.332-345
    • /
    • 2014
  • In recent years, precision machining of the dental prosthesis by computer assisted system is becoming pervasive in clinical dentistry. Prosthesis fabricating system that is designed by computer software and made by computer devices is called as a CAD/CAM (Computer-Aided Design/Computer-Aided Manufacturing) system. By the use of dental CAD/CAM system, the improvement of marginal compatibility and mechanical properties in prosthesis can be obtained more effectively, an aesthetic quality by using new materials such as zirconia can be increased. Also, the restoration process can be simple and efficient, the production time can be shortened, the process of manufacture can be standardized, and the mass production is possible. What is clear is that these benefits are theoretically possible, but the dentist or dental technician must understand the CAD/CAM basic principles and limitations for obtaining the maximum advantages of CAD/CAM system. For this reason, this article will be presented about the basic principles of CAD/CAM system and the factors of error that might occur in the CAD/CAM process based on my empirical study.

CAE/CAD/CAM system for factory automation (공장 자동화를 위한 CAE/CAD/CAM 시스템)

  • Chae, Heon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.443-447
    • /
    • 1986
  • 오늘날 제조업에 있어서는 시장의 다양화, 원가절감 및 리드타임의 단축이라는 대내외적 요구에 부응할 수 있는 기술 생산체재의 확립이 요구되고 있다. 이에 따라 설계 및 기술변경(Engineering Change)에따른 원가상승을 막기 위해 CAE(Computer aided engineering), CAD(Computer aided design)의 도입을 서두르게 되었고 CAD데이타의 효율적 이용에 의한 가공 및 생산적 측면에서 CAM(Computer aided manufacturing)의 도입도 검토하게 되었다. 본 논문은 이러한 개념의 발상동기와 이를 뒷받침하기 위한 한국 아이 비 엠이서 제공하는 하드웨어 및 소프트웨어를 소개하고 공장자동화를 위한 기술 생산 통합시스템의 구축이라는 측면에서 아이 비 엠이 추구하는 방향을 검토하고 있다.

  • PDF