The factors caused errors in the production process of CAD/CAM prosthesis based on experience

임상가를 위한 특집 1 - CAD/CAM 보철물의 제작 과정에서 오류가 발생할 수 있는 요소들에 대한 경험적 고찰

  • Huh, Jung-Bo (Department of Prosthodontics, School of Dentistry, Pusan National University) ;
  • Shim, June-Sung (Department of Prosthodontics, College of Dentistry, Yonsei University)
  • 허중보 (부산대학교 치의학전문대학원 치과보철학교실) ;
  • 심준성 (연세대학교 치과대학 치과보철학교실)
  • Received : 2014.05.16
  • Accepted : 2014.05.23
  • Published : 2014.06.01

Abstract

In recent years, precision machining of the dental prosthesis by computer assisted system is becoming pervasive in clinical dentistry. Prosthesis fabricating system that is designed by computer software and made by computer devices is called as a CAD/CAM (Computer-Aided Design/Computer-Aided Manufacturing) system. By the use of dental CAD/CAM system, the improvement of marginal compatibility and mechanical properties in prosthesis can be obtained more effectively, an aesthetic quality by using new materials such as zirconia can be increased. Also, the restoration process can be simple and efficient, the production time can be shortened, the process of manufacture can be standardized, and the mass production is possible. What is clear is that these benefits are theoretically possible, but the dentist or dental technician must understand the CAD/CAM basic principles and limitations for obtaining the maximum advantages of CAD/CAM system. For this reason, this article will be presented about the basic principles of CAD/CAM system and the factors of error that might occur in the CAD/CAM process based on my empirical study.

Keywords

References

  1. 고정성치과보철학교수협의회. 고정성치과보철학원리와 임상. 대한나래출판사 2012 page 440.
  2. Wagman SS. The role of coronal contour in gingival health. J Prosthet Dent. 1977 ;37:280-7. https://doi.org/10.1016/0022-3913(77)90070-1
  3. 배지철, 김원희, 전영찬, 정창모, 윤미정, 허중보. CAD/CAM의 복제 기법을 이용한 전방 유도의 재현 증례. 대한치과보철학회지 2014;52:121-127.
  4. 김성준, 조광헌, 이규복. 수종의CAD/CAM 시스템으로 제작한 지르코니아 기반 완전도재관의 적합도 비교. 대한치과보철학회지 2008;47:148-55.
  5. Reich S, Wichmann M, Nkenke E, Proeschel P. Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems. Eur J oral Sci 2005;113:174-9. https://doi.org/10.1111/j.1600-0722.2004.00197.x
  6. Nakamura T, Dei N, Kojima T. Wakabayashi K. Marginal and internal fit of Cerec 3 CAD/CAM allceramic crowns. Int J Prosthodont 2003;16:244-8.
  7. Zhang Y, Li J, Xue XQ, Chen ZY, Li XJ. A comparison of three-dimensional marginal adaptation among three all-ceramic crown systems. Shanghai Kou Qiang Yi Xue 2011;20:494-9.
  8. 허중보, 김우식, 김하영, 김종은, 이정렬, 김영수, 전영찬, 신상완. 다양한CAD/CAM 시스템으로 제작된 3 본 고정성 가공의치 지르코니아 코어의 변연 및 내면 적합도 평가. 대한치과보철학회지 2011;49:236-244.
  9. 허중보, 박청길, 김하영, 박찬경, 신상완. 수종의 CAD/CAM 시스템으로 제작한 지르코니아 코어에서 Replica Technique을 이용한 변연 및 내면 적합도 평가. 대한치과보철학회지 2010;48:135-142.
  10. Kim SY, Lee SH, Cho SK, Jeong CM, Jeon YC, Yun MJ, Huh JB. Comparison of the accuracy of digitally fabricated polyurethane model and conventional gypsum model. J Adv Prosthodont. 2014;6:1-7. https://doi.org/10.4047/jap.2014.6.1.1