• 제목/요약/키워드: Computer assisted radiotherapy planning

검색결과 7건 처리시간 0.022초

Volumetric-Modulated Arc Radiotherapy Using Knowledge-Based Planning: Application to Spine Stereotactic Body Radiotherapy

  • Jeong, Chiyoung;Park, Jae Won;Kwak, Jungwon;Song, Si Yeol;Cho, Byungchul
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.94-103
    • /
    • 2019
  • Purpose: To evaluate the clinical feasibility of knowledge-based planning (KBP) for volumetric-modulated arc radiotherapy (VMAT) in spine stereotactic body radiotherapy (SBRT). Methods: Forty-eight VMAT plans for spine SBRT was studied. Two planning target volumes (PTVs) were defined for simultaneous integrated boost: PTV for boost (PTV-B: 27 Gy/3fractions) and PTV elective (PTV-E: 24 Gy/3fractions). The expert VMAT plans were manually generated by experienced planners. Twenty-six plans were used to train the KBP model using Varian RapidPlan. With the trained KBP model each KBP plan was automatically generated by an individual with little experience and compared with the expert plan (closed-loop validation). Twenty-two plans that had not been used for KBP model training were also compared with the KBP results (open-loop validation). Results: Although the minimal dose of PTV-B and PTV-E was lower and the maximal dose was higher than those of the expert plan, the difference was no larger than 0.7 Gy. In the closed-loop validation, D1.2cc, D0.35cc, and Dmean of the spinal cord was decreased by 0.9 Gy, 0.6 Gy, and 0.9 Gy, respectively, in the KBP plans (P<0.05). In the open-loop validation, only Dmean of the spinal cord was significantly decreased, by 0.5 Gy (P<0.05). Conclusions: The dose coverage and uniformity for PTV was slightly worse in the KBP for spine SBRT while the dose to the spinal cord was reduced, but the differences were small. Thus, inexperienced planners could easily generate a clinically feasible plan for spine SBRT by using KBP.

Comparison of 2-Dimensional and 3-Dimensional Conformal Treatment Plans in Gastric Cancer Radiotherapy

  • Adas, Yasemin Guzle;Andrieu, Meltem Nalca;Hicsonmez, Ayse;Atakul, Tugba;Dirican, Bahar;Aktas, Caner;Yilmaz, Sercan;Akyurek, Serap;Gokce, Saban Cakir;Ergocen, Salih
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권17호
    • /
    • pp.7401-7405
    • /
    • 2014
  • Background: Postoperative chemoradiotherapy is accepted as standard treatment for stage IB-IV, M0 gastric cancer. Radiotherapy (RT) planning of gastric cancer is important because of the low radiation tolerance of surrounding critical organs. The purpose of this study was to compare the dosimetric aspects of 2-dimensional (2D) and 3-dimensional (3D) treatment plans, with the twin aims of evaluating the adequacy of 2D planning fields on coverage of planning target volume (PTV) and 3D conformal plans for both covering PTV and reducing the normal tissue doses. Materials and Methods: Thirty-six patients with stage II-IV gastric adenocarcinoma were treated with adjuvant chemoradiotherapy using 3DRT. For each patient, a second 2D treatment plan was generated. The two techniques were compared for target volume coverage and dose to normal tissues using dose volume histogram (DVH) analysis. Results: 3DRT provides more adequate coverage of the target volume. Comparative DVHs for the left kidney and spinal cord demonstrate lower radiation doses with the 3D technique. Conclusions: 3DRT produced better dose distributions and reduced radiation doses to left kidney and spinal cord compared to the 2D technique. For this reason it can be predicted that 3DRT will result in better tumor control and less normal tissue complications.

The accuracy of a 3D printing surgical guide determined by CBCT and model analysis

  • Ma, Boyoung;Park, Taeseok;Chun, Inkon;Yun, Kwidug
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.279-285
    • /
    • 2018
  • PURPOSE. The aim of this clinical study was to assess the accuracy of the implants placed using a universal digital surgical guide. MATERIALS AND METHODS. Among 17 patients, 28 posterior implants were included in this study. The digital image of the soft tissue acquired from cast scan and hard tissue from CBCT have been superimposed and planned the location, length, diameter of the implant fixture. Then digital surgical guides were created using 3D printer. Each of angle deviations, coronal, apical, depth deviations of planned and actually placed implants were calculated using CBCT scans and casts. To compare implant positioning errors by CBCT scans and plaster casts, data were analyzed with independent samples t-test. RESULTS. The results of the implant positioning errors calculated by CBCT and casts were as follows. The means for CBCT analyses were: angle deviation: $4.74{\pm}2.06^{\circ}$, coronal deviation: $1.37{\pm}0.80mm$, and apical deviation: $1.77{\pm}0.86mm$. The means for cast analyses were: angle deviation: $2.43{\pm}1.13^{\circ}$, coronal deviation: $0.82{\pm}0.44mm$, apical deviation: $1.19{\pm}0.46mm$, and depth deviation: $0.03{\pm}0.65mm$. There were statistically significant differences between the deviations of CBCT scans and cast. CONCLUSION. The model analysis showed lower deviation value comparing the CBCT analysis. The angle and length deviation value of the universal digital guide stent were accepted clinically.

Dosimetric advantages and clinical outcomes of simultaneous integrated boost intensity-modulated radiotherapy for anal squamous cell carcinoma

  • Sakanaka, Katsuyuki;Itasaka, Satoshi;Ishida, Yuichi;Fujii, Kota;Horimatsu, Takahiro;Mizowaki, Takashi;Sakai, Yoshiharu;Hiraoka, Masahiro
    • Radiation Oncology Journal
    • /
    • 제35권4호
    • /
    • pp.368-379
    • /
    • 2017
  • Purpose: The purpose of this study was to explore the dosimetric difference between simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT) and three-dimensional conformal radiotherapy (3DCRT), and the clinical outcomes of anal squamous cell carcinoma (ASCC) chemoradiotherapy featuring SIB-IMRT. Materials and Methods: This study included ten patients with ASCC who underwent chemoradiotherapy using SIB-IMRT with 5-fluorouracil and mitomycin C. SIB-IMRT delivered 54 Gy to each primary tumor plus metastatic lymph nodes and 45 Gy to regional lymph nodes, in 30 fractions. Four patients received additional boosts to the primary tumors and metastatic lymph nodes; the median total dose was 54 Gy (range, 54 to 60 Gy). We additionally created 3DCRT plans following the Radiation Therapy Oncology Group 9811 protocol to allow dosimetric comparisons with SIB-IMRT. Locoregional control, overall survival, and toxicity were calculated for the clinical outcome evaluation. Results: Compared to 3DCRT, SIB-IMRT significantly reduced doses to the external genitalia, bladder, and intestine, delivering the doses to target and elective nodal region. At a median follow-up time of 46 months, 3-year locoregional control and overall survival rates were 88.9% and 100%, respectively. Acute toxicities were treated conservatively. All patients completed radiotherapy with brief interruptions (range, 0 to 2 days). No patient experienced ${\geq}grade$ 3 late toxicity during the follow-up period. Conclusion: The dosimetric advantages of SIB-IMRT appeared to reduce the toxicity of chemoradiotherapy for ASCC achieving high locoregional control in the extended period.

A predictive model to guide management of the overlap region between target volume and organs at risk in prostate cancer volumetric modulated arc therapy

  • Mattes, Malcolm D.;Lee, Jennifer C.;Elnaiem, Sara;Guirguis, Adel;Ikoro, N.C.;Ashamalla, Hani
    • Radiation Oncology Journal
    • /
    • 제32권1호
    • /
    • pp.23-30
    • /
    • 2014
  • Purpose: The goal of this study is to determine whether the magnitude of overlap between planning target volume (PTV) and rectum ($Rectum_{overlap}$) or PTV and bladder ($Bladder_{overlap}$) in prostate cancer volumetric-modulated arc therapy (VMAT) is predictive of the dose-volume relationships achieved after optimization, and to identify predictive equations and cutoff values using these overlap volumes beyond which the Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC) dose-volume constraints are unlikely to be met. Materials and Methods: Fifty-seven patients with prostate cancer underwent VMAT planning using identical optimization conditions and normalization. The PTV (for the 50.4 Gy primary plan and 30.6 Gy boost plan) included 5 to 10 mm margins around the prostate and seminal vesicles. Pearson correlations, linear regression analyses, and receiver operating characteristic (ROC) curves were used to correlate the percentage overlap with dose-volume parameters. Results: The percentage $Rectum_{overlap}$ and $Bladder_{overlap}$ correlated with sparing of that organ but minimally impacted other dose-volume parameters, predicted the primary plan rectum $V_{45}$ and bladder $V_{50}$ with $R^2$ = 0.78 and $R^2$ = 0.83, respectively, and predicted the boost plan rectum $V_{30}$ and bladder $V_{30}$ with $R^2$ = 0.53 and $R^2$ = 0.81, respectively. The optimal cutoff value of boost $Rectum_{overlap}$ to predict rectum $V_{75}$ >15% was 3.5% (sensitivity 100%, specificity 94%, p < 0.01), and the optimal cutoff value of boost $Bladder_{overlap}$ to predict bladder $V_{80}$ >10% was 5.0% (sensitivity 83%, specificity 100%, p < 0.01). Conclusion: The degree of overlap between PTV and bladder or rectum can be used to accurately guide physicians on the use of interventions to limit the extent of the overlap region prior to optimization.

자궁암의 고선량율 근접 방사선치료시 전산화 치료계획 시스템과 in vivo dosimetry system 을 이용하여 측정한 직장 선량 비교 (Comparison between the Calculated and Measured Doses in the Rectum during High Dose Rate Brachytherapy for Uterine Cervical Carcinomas)

  • 정은지;이상훈
    • Radiation Oncology Journal
    • /
    • 제20권4호
    • /
    • pp.396-404
    • /
    • 2002
  • 목적 : 자궁암의 방사선치료시 호발하는 직장 부작용은 직장 방사선량과 관계가 있다는 보고들이 많다. ICRU 38에 따른 직장 선량을 측정함으로 강내 방사선치료 시에 조사되는 직장선량의 정도 관리에 기여할 수 있다고 생각하여 전산상 계산된 선량과 강내치료시 다이오드 검출기로 직접 측정된 직장 선량의 차이를 비교해 보고자 하였다. 대상 : 2001년 6월-2002년 2월까지 고선량율 Iridium-192 동위원소를 이용하여 고선량율 강내 방사선치료를 시행 받은 자궁경부암 환자 9명을 대상으로 하였다. 강내치료는 주 2회씩 A점에 총 $6\~8$회간 총 $28\~32\;Gy$ 시행되었다 9명에서 총 44회의 강내치료 중 선량 측정이 가능하였고, 모의치료 계획시의 필름 및 분할 고선량율 강내 방사선치료 시에 촬영한 필름을 기준으로 전산화 계획 시스템상 계산한 직장 기준점 선량과 강내치료를 하면서 다이오드 직장 검출기에서 측정된 선량을 각각 분석하였다. 결과 : 모의치료시 필름을 기준한 직장의 전산화 계획상의 선량과 강내치료 시마다 촬영한 필름으로 다시 전산화 계획상 계산한 직장선량값 사이에는 상당한 차이가 있었다. 강내치료시에 촬영한 사진을 기준으로 전산화 설계에서 계산된 값과 강내치료 중에 검출기로 측정한 직장 선량 사이에도 차이가 많았다. 직장 검출기 표시점의 치료계획 선량을 5개 점에서 계산해 보았을 때 ICRU 38 직장 기준점이 최대 직장 선량점과 일치하는 경우는 $22.2\%$ (2/9)에 불과하였다. 결론 : 자궁암에서 고선량율 강내 방사선치료 선량을 계획할 때 모의 치료시 촬영한 필름만 가지고 직장 선량을 최적화하는 것이 가장 적절한 방법이라고 볼 수는 없다. 본 연구를 통해 고선량율 강내치료시의 직장 선량이 치료시마다 상당히 변화가 많다는 사실을 확인하였으므로 가능하면 직장선량을 실측하거나 아니면 최소한 직장표지기를 삽입하고 측방 투시를 함으로 직장 위치를 파악하는 것이 자궁암의 고선량을 강내 방사선치료에서 정도관리 면에서 중요한 과정이라 생각한다.

Piroxicam, Mitoxantrone, and Hypofractionated Radiation Therapy with Volumetric Modulated Arc Therapy for Treating Urinary Transitional Cell Carcinoma in a Dog: A Case Report

  • Hwang, Tae-Sung;An, Soyon;Choi, Moon-Young;Huh, Chan;Song, Joong-Hyun;Jung, Dong-In;Lee, Hee Chun
    • 한국임상수의학회지
    • /
    • 제39권1호
    • /
    • pp.16-22
    • /
    • 2022
  • A 12-year-old spayed female beagle dog was presented with pollakiuria and stranguria. Abdominal ultrasonography identified irregular a marginated, hyperechoic mass in the urethra and trigon area of the bladder. Computed tomography (CT) revealed a heterogeneous mass in the trigone area leading to a urethra. There was no evidence of regional or distant metastasis. Cytologic analysis suspected transitional cell carcinoma (TCC). The patient was treated with piroxicam, mitoxantrone, and once weekly fractionated radiation therapy (RT) with volumetric modulated arc therapy (VMAT). A follow-up CT scan at 6 months after RT revealed a reduction in tumor size. At 17 months after the start of RT, the patient became severely anorectic and lethargic. Ultrasound examination revealed a hyperechoic mass in the apex area of bladder while the trigone area of the bladder and urethra appeared normal. Multiple hypoechoic nodules of various sizes were found in the liver and spleen. The patient was humanely euthanized at the request of the owner. A combination of piroxicam, mitoxantrone, and hypofractionated RT with VMAT protocol was well tolerated. This case described tumor response and survival time of a canine TCC treated with piroxicam, mitoxantrone, and once weekly palliative RT using computer-assisted planning and VMAT.