• 제목/요약/키워드: Computer assisted image analysis

검색결과 41건 처리시간 0.031초

Comparison of instrumental methods for color change assessment of Giomer resins

  • Luiza de Almeida Queiroz Ferreira;Rogeli Tiburcio Ribeiro da Cunha Peixoto ;Claudia Silami de Magalhaes;Tassiana Melo Sa;Monica Yamauti ;Francisca Daniele Moreira Jardilino
    • Restorative Dentistry and Endodontics
    • /
    • 제47권1호
    • /
    • pp.8.1-8.9
    • /
    • 2022
  • Objectives: The aim of this study was to compare the color change of the Giomer resin composite (Beautifil-Bulk) by using photographs obtained with a smartphone (iPhone 6S) associated with Adobe Photoshop software (digital method), with the spectrophotometric method (Vita Easyshade) after immersion in different pigment solutions. Materials and Methods: Twenty resin composite samples with a diameter of 15.0 mm and thickness of 1.0 mm were confectioned in A2 color (n = 5). Photographs and initial color readings were performed with a smartphone and spectrophotometer, respectively. Then, samples were randomly divided and subjected to cycles of immersion in distilled water (control), açai, Coke, and tomato sauce, 3 times a day, 20 minutes for 7 days. Later, new photographs and color readings were taken. Results: The analysis (2-way analysis of variance, Holm-Sidak, p < 0.05) demonstrated no statistical difference (p < 0.005) between the methods in all groups. Similar color changes were observed for all pigment solutions when using the spectrophotometric method. For the digital method, all color changes were clinically unacceptable, with distilled water and tomato sauce similar to each other and with statistical differences (p < 0.005) for Coke and açai. Conclusions: Only the tomato sauce produced a color change above the acceptability threshold using both methods of color assessment. The spectrophotometric and digital methods produce different patterns of color change. According to our results, the spectrophotometric method is more recommended in color change assessment.

컴퓨터단층촬영을 이용한 상악동 중격의 형태학적 분석 (Morphological analysis of maxillary sinus septum using computed tomography)

  • 채종범;이상한;김진수;김종배;권대근
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권1호
    • /
    • pp.36-42
    • /
    • 2011
  • Introduction: The current study examined the morphological characteristics of maxillary sinus septum by computed tomography (CT). Materials and Methods: Two hundred and four patients (408 maxillary sinuses) who visited dental clinic were evaluated. CT were examined. The height of the septum measured from the sinus floor to the apex of the septum more than 3 mm was defined as "sinus septum". Results: The prevalence of sinus septa was 21.3% (87/408), and 31.4% (64/204) of patients had more than 1 sinus septum. Females showed higher and thinner sinus septa than males. The anatomic location of the septa were distributed in the 2nd molar region (43.7%), 1st molar region (31.0%), 2nd premolar region (21.8%) and 1st premolar region (3.5%). In 57 patients with chronic disease, there was no significant difference between sinus disease and the presence of sinus septa. The loss of remaining teeth and teeth adjacent to the sinus septum area was not related to the presence of sinus septa. Older subjects showed a reduced height and length of the septum, and a thicker septum. Conclusion: These results show that the maxillary sinus septum undergoes atrophy with age.

A feasibility study evaluating the relationship between dose and focal liver reaction in stereotactic ablative radiotherapy for liver cancer based on intensity change of Gd-EOB-DTPA-enhanced magnetic resonance images

  • Jung, Sang Hoon;Yu, Jeong Il;Park, Hee Chul;Lim, Do Hoon;Han, Youngyih
    • Radiation Oncology Journal
    • /
    • 제34권1호
    • /
    • pp.64-75
    • /
    • 2016
  • Purpose: In order to evaluate the relationship between the dose to the liver parenchyma and focal liver reaction (FLR) after stereotactic ablative body radiotherapy (SABR), we suggest a novel method using a three-dimensional dose distribution and change in signal intensity of gadoxetate disodium-gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) hepatobiliary phase images. Materials and Methods: In our method, change of the signal intensity between the pretreatment and follow-up hepatobiliary phase images of Gd-EOB-DTPA-enhanced MRI was calculated and then threshold dose (TD) for developing FLR was obtained from correlation of dose with the change of the signal intensity. For validation of the method, TDs for six patients, who had been treated for liver cancer with SABR with 45-60 Gy in 3 fractions, were calculated using the method, and we evaluated concordance between volume enclosed by isodose of TD by the method and volume identified as FLR by a physician. Results: The dose to normal liver was correlated with change in signal intensity between pretreatment and follow-up MRI with a median $R^2$ of 0.935 (range, 0.748 to 0.985). The median TD by the method was 23.5 Gy (range, 18.3 to 39.4 Gy). The median value of concordance was 84.5% (range, 44.7% to 95.9%). Conclusion: Our method is capable of providing a quantitative evaluation of the relationship between dose and intensity changes on follow-up MRI, as well as determining individual TD for developing FLR. We expect our method to provide better information about the individual relationship between dose and FLR in radiotherapy for liver cancer.

Correlation analysis of periodontal tissue dimensions in the esthetic zone using a non-invasive digital method

  • Kim, Yun-Jeong;Park, Ji-Man;Cho, Hyun-Jae;Ku, Young
    • Journal of Periodontal and Implant Science
    • /
    • 제51권2호
    • /
    • pp.88-99
    • /
    • 2021
  • Purpose: Direct intraoral scanning and superimposing methods have recently been applied to measure the dimensions of periodontal tissues. The aim of this study was to analyze various correlations between labial gingival thickness and underlying alveolar bone thickness, as well as clinical parameters among 3 tooth types (central incisors, lateral incisors, and canines) using a digital method. Methods: In 20 periodontally healthy subjects, cone-beam computed tomography images and intraoral scanned files were obtained. Measurements of labial alveolar bone and gingival thickness at the central incisors, lateral incisors, and canines were performed at points 0-5 mm from the alveolar crest on the superimposed images. Clinical parameters including the crown width/crown length ratio, keratinized gingival width, gingival scallop, and transparency of the periodontal probe through the gingival sulcus were examined. Results: Gingival thickness at the alveolar crest level was positively correlated with the thickness of the alveolar bone plate (P<0.05). The central incisors revealed a strong correlation between labial alveolar bone thickness at 1 and 2 mm, respectively, inferior to the alveolar crest and the thickness of the gingiva at the alveolar crest line (G0), whereas G0 and labial bone thickness at every level were positively correlated in the lateral incisors and canines. No significant correlations were found between clinical parameters and hard or soft tissue thickness. Conclusions: Gingival thickness at the alveolar crest level revealed a positive correlation with labial alveolar bone thickness, although this correlation at identical depth levels was not significant. Gingival thickness, at or under the alveolar crest level, was not associated with the clinical parameters of the gingival features, such as the crown form, gingival scallop, or keratinized gingival width.

Ektaspeed plus 필름을 이용한 일반 방사선시스템과 Digora를 이용한 디지탈 영상시스템의 밀도변화 비교연구 (Consideration of density matching technique of the plate type direct radiologic image system and the conventional X-ray film;first step for the subtraction)

  • 소성수;노현수;김창성;최성호;김기덕;조규성
    • Journal of Periodontal and Implant Science
    • /
    • 제32권1호
    • /
    • pp.199-211
    • /
    • 2002
  • Digital substraction technique and computer-assisted densitometirc analysis detect minor change in bone density and thus increase the diagnostic accuracy. This advantage as well as high sensitivity and objectivity which precludes human bias have drawn interest in radiologic research area. The objectives of this study are to verify if Radiographic density can be recognized in linear pattern when density profile of standard periapical radiograph with the aluminium stepwedge as the reference, was investigated under varies circumstances which can be encountered in clinical situations, and in addition to that to obtain mutual relationship between the existing standard radiographic system, and future digital image systems, by confirming the corelationship between the standard radiograph and Digora system which is a digital image system currently being used. In order to make quantitative analysis of the bone tissue, digital image system which uses high resolution automatic slide scanner as an input device, and Digora system were compared and analyzed using multifunctional program, Brain3dsp. The following conclusions were obtained. 1. Under common clinical situation that is 70kVp, 0.2 sec., and focal distance 10cm, Al-Equivalent image equation was found to be Y=11.21X+46.62 $r^2=0.9898$ in standard radiographic system, and Y=12.68X+74.59, $r^2=0.9528$ in Digora system, and linear relation was confirmed in both the systems. 2. In standard radiographic system, when all conditions were maintained the same except for the condition of developing solution, Al-Equivalent image equation was Y=10.07X+41.64, $r^2=0.9861$ which shows high corelationship. 3. When all conditions were maintained the same except for the Kilovoltage peak, linear relationship was still maintained under 60kVp, and Al-Equivalent image equation was Y=14.60X+68.86, $r^2=0.9886$ in the standard radiograhic system, and Y=13.90X+80.68, $r^2=0.9238$ in Digora system. 4. When all conditions were maintained the same except for the exposure time which was varied from 0.01 sec. to 0.8 sec., Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9188 to 0.9900, and in general, standard radiographic system showed higher R-square than Digora system. 5. When all conditions were maintained the same except for the focal distance which was varied from 5cm to 30cm, Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9463 to 0.9925, and the standard radiographic system had the tendency to show higher R-square in shorter focal distances.

How image-processing parameters can influence the assessment of dental materials using micro-CT

  • Torres, Fernanda Ferrari Esteves;Jacobs, Reinhilde;EzEldeen, Mostafa;de Faria-Vasconcelos, Karla;Guerreiro-Tanomaru, Juliane Maria;dos Santos, Bernardo Camargo;Tanomaru-Filho, Mario
    • Imaging Science in Dentistry
    • /
    • 제50권2호
    • /
    • pp.161-168
    • /
    • 2020
  • Purpose: The aim of this study was to evaluate the influence of voxel size and different post-processing algorithms on the analysis of dental materials using micro-computed tomography (micro-CT). Materials and Methods: Root-end cavities were prepared in extracted maxillary premolars, filled with mineral trioxide aggregate (MTA), Biodentine, and Intermediate Restorative Material (IRM), and scanned using micro-CT. The volume and porosity of materials were evaluated and compared using voxel sizes of 5, 10, and 20 ㎛, as well as different software tools(post-processing algorithms). The CTAn or MeVisLab/Materialise 3-matic software package was used to perform volume and morphological analyses, and the CTAn or MeVisLab/Amira software was used to evaluate porosity. Data were analyzed using 1-way ANOVA and the Tukey test(P<0.05). Results: Using MeVisLab/Materialise 3-matic, a consistent tendency was observed for volume to increase at larger voxel sizes. CTAn showed higher volumes for MTA and IRM at 20 ㎛. Using CTAn, porosity values decreased as voxel size increased, with statistically significant differences for all materials. MeVisLab/Amira showed a difference for MTA and IRM at 5 ㎛, and for Biodentine at 20 ㎛. Significant differences in volume and porosity were observed in all software packages for Biodentine across all voxel sizes. Conclusion: Some differences in volume and porosity were found according to voxel size, image-processing software, and the radiopacity of the material. Consistent protocols are needed for research evaluating dental materials.

방사선사진에서의 골질과 임상적으로 평가한 골질 분류의 상관관계 (Correlation of bone quality in radiographic images with clinical bone quality classification)

  • 김현우;허경회;박관수;김정화;이원진;허민석;이삼선;최순철
    • Imaging Science in Dentistry
    • /
    • 제36권1호
    • /
    • pp.25-32
    • /
    • 2006
  • Purpose : To investigate the validity of digital image processing on panoramic radiographs in estimating bone quality before endosseous dental implant installation by correlating bone quality in radiographic images with clinical bone quality classification. Materials and Methods : An experienced surgeon assessed and classified bone quality for implant sites with tactile sensation at the time of implant placement. Including fractal dimension eighteen morphologic features of trabecular pattern were examined In each anatomical sites on panoramic radiographs. Finally bone quality of 67 implant sites were evaluated in 42 patients. Results : Pearson correlation analysis showed that three morphologic parameters had weak linear negative correlation with clinical bone quality classification showing correlation coefficients of -0.276, -0.280, and - 0.289, respectively (p<0.05). And other three morphologic parameters had obvious linear negative correlation with clinical bone quality classification showing correlation coefficients of -0.346, -0.488, and -0.343 respectively (p<0.05). Fractal dimension also had a linear correlation with clinical bone quality classification with correlation coefficients -0.506 significantly (p<0.05). Conclusion : This study suggests that fractal and morphometric analysis using digital panoramic radiographs can be used to evaluate bone quality for implant recipient sites.

  • PDF

유방암 방사선치료에 있어 치료도중 및 분할치료 간 위치오차에 대한 전자포탈영상의 컴퓨터를 이용한 자동 분석 (Computer Assisted EPID Analysis of Breast Intrafractional and Interfractional Positioning Error)

  • ;;;;진호상;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제17권1호
    • /
    • pp.24-31
    • /
    • 2006
  • 유방암 환자의 방사선치료에 있어 치료도중(intrafractional) 및 분할 치료 간(intefractional)에 발생되는 오차를 측정하는 자동분석소프트웨어를 개발하였다. 오차 분석 결과는 3차원 입체조형 방사선치료를 임상에 적용하기에 앞서 적절한 치료계획용적(Planning Target Volume, PTV)을 설정하는 데 있어 매우 중요하다. 본 연구에서는 전자포탈영상장치(Electrical Portal imaging Device, EPID)로써 Portal Vision LC250 액체 충전형 이온화 검출기를 사용하였다(fast frame-averaging 모드, 초당 1.4 프레임, 256X256 픽셀). 12명의 환자에 대해 최소 7일 이상씩 영상을 획득하였다. 매 치료마다 평균 8 내지 9개의 영상을 각 빔에 대해 얻었다(분당 400 MU 선량률). 총 2,931 (720 측정을 포함하는)개의 영상을 정량적으로 분석할 수 있는 자동화 영상 분석 소프트웨어를 개발하였다. 이를 통해 호흡으로 인해 발생하는 치료도중 오차와 분할 치료간 발생하는 분할치료오차의 표준편차($\sigma$)들을 계산하였다. 신뢰 구간 95%로 임상표적체적(Clinical Target Volume, CTV)을 포함할 수 있는 PTV 마진은 $2\;(1.96\;{\sigma})$으로 계산되었다. 주로 호흡으로 인해 유발되는 치료도중오차를 보상하기 위해 필요한 PTV 마진은 2 mm에서 4 mm이었다. 반면에 분할 치료간 오차를 보상하기위해 필요한 PTV 마진은 7 mm에서 31 mm이었다. 12명의 환자에 대한 전체 평균오차는 17 mm이었다. 분할치료 간 오차는 호흡에 의해 유발되는 치료도중 오차에 비해 2배에서 15배까지 더 크게 나타났다. 유방암 치료에 있어 3차원 입체정형조사나 세기조절방사선치료(Intensity Modulated Radiation Therapy, IMRT)를 적용하기에 앞서 반드시 셋업 오차의 크기를 측정하여 PTV에 적절히 반영되어야 한다. 유방에 대한 3차원 입체정형조사나 세기조절방사선치료를 위해 반드시 필요한 것은 아니지만, 큰 PTV 마진을 줄여주기 위해서는 영상유도방사선치료(Image Guided Radiation Therapy, IGRT)가 매우 유용하게 이용될 수 있다. 전자포탈영상장치 들은 본 보고서에서 기술한 바와 같은 자동분석소프트웨어를 반드시 포함하여야 한다. 이를 통해 수많은 EPID 영상들을 자동화 처리하고 오차분석을 시행함으로써 각 병원의 임상적용 방법 및 환경에 따라 상이하게 나타날 수 있는 오차의 크기를 감안한 적절한 PTV마진을 구하는데 도움을 얻을 수 있다. 이러한 장치들은 또한 최소의 노력으로 환자 치료를 관찰할 수 있는 귀중한 정보를 제공해 준다.

  • PDF

디지털 및 일반 측방두부규격방사선사진에서 측정 방법에 따른 계측치의 비교 (The comparison of cephalometric measurements between measuring methods in digital and conventional lateral cephalometric radiograph)

  • 김미자;허경회;이원진;허민석;이삼선;이진구;안병근;최순철
    • Imaging Science in Dentistry
    • /
    • 제35권1호
    • /
    • pp.15-23
    • /
    • 2005
  • Purpose : To compare cephalometric measurement between measuring methods in digital and conventional lateral cephalometric radiograph. Materials and Methods : Twenty digital and conventional lateral cephalometric radiographs were selected. In digital group, cephalometric measurements were performed manually using hardcopies and automatically using $V-Ceph^{TM}$ program on the monitor. In conventional group, the same measurements were performed manually on conventional films, and for automatic measurement conventional films were digitized by scanner. All measurements were performed twice by 4 observers, and 24 cephalometric variables were calculated and the time spent for each measurement was recorded. The differences in measurements data and the time spent for each measurement were compared within each group. Intra-observer and inter-observer comparisons were performed. Results : In both groups, no statistically significant difference between manual and automatic measurements was observed and most of the variables didn't show statistically significant differences between methods. The observer with less experience tended to show statistically significant differences of measurements between methods, and differences from other observers. The differences of measurements between methods in digital group were lesser than those of conventional group with statistical significance in 8 variables out of 24. With automatic method and in digital group, the spent time was shorter. Conclusion : With direct digital radiograph, automatic method using manually idenitified landmarks can be preferable in cephalometric analysis. (Korean J Oral Maxillofac Radiol 2005; 35 : 15-23)

  • PDF

Morphologic Alterations in Amygdala Subregions of Adult Patients with Bipolar Disorder

  • Lee, Hyun-Jae;Han, Kyu-Man;Kim, Aram;Kang, Wooyoung;Kang, Youbin;Kang, June;Won, Eunsoo;Tae, Woo-Suk;Ham, Byung-Joo
    • 생물정신의학
    • /
    • 제26권1호
    • /
    • pp.22-31
    • /
    • 2019
  • Objectives Previous studies have revealed inconsistent results on amygdala volume in adult bipolar disorder (BD) patients compared to healthy controls (HC). Since the amygdala encompasses multiple subregions, the subtle volume changes in each amygdala nucleus might have not been fully reflected in the measure of the total amygdala volume, causing discrepant results. Thus, we aimed to investigate volume changes in each amygdala subregion and their association with subtypes of BD, lithium use and clinical status of BD. Methods Fifty-five BD patients and 55 HC underwent T1-weighted structural magnetic resonance imaging. We analyzed volumes of the whole amygdala and each amygdala subregion, including the anterior amygdaloid area, cortico-amygdaloid transition area, basal, lateral, accessory basal, central, cortical, medial and paralaminar nuclei using the atlas in the FreeSurfer. The volume difference was analyzed using a one-way analysis of covariance with individual volumes as dependent variables, and age, sex, and total intracranial volume as covariates. Results The volumes of whole right amygdala and subregions including basal nucleus, accessory basal nucleus, anterior amygdaloid area, and cortico-amygdaloid transition area in the right amygdala of BD patients were significantly smaller for the HC group. No significant volume difference between bipolar I disorder and bipolar II disorder was found after the Bonferroni correction. The trend of larger volume in medial nucleus with lithium treatment was not significant after the Bonferroni correction. No significant correlation between illness duration and amygdala volume, and insignificant negative correlation were found between right central nucleus volume and depression severity. Conclusions Significant volume decrements of the whole amygdala, basal nucleus, accessory basal nucleus, anterior amygdaloid area, and cortico-amygdaloid transition area were found in the right hemisphere in adult BD patients, compared to HC group. We postulate that such volume changes are associated with altered functional activity and connectivity of amygdala nuclei in BD.