• Title/Summary/Keyword: Computer aided design(CAD)

Search Result 529, Processing Time 0.029 seconds

A 48-month clinical performance of hybrid ceramic fragment restorations manufactured in CAD/CAM in non-carious cervical lesions: case report

  • Michael Willian Favoreto;Gabriel David Cochinski;Eveline Claudia Martini;Thalita de Paris Matos;Matheus Coelho Bandeca;Alessandro Dourado Loguercio
    • Restorative Dentistry and Endodontics
    • /
    • v.49 no.3
    • /
    • pp.32.1-32.12
    • /
    • 2024
  • From the restorative perspective, various methods are available to prevent the progression of non-carious cervical lesions. Direct, semi-direct, and indirect composite resin techniques and indirect ceramic restorations are commonly recommended. In this context, semi-direct and indirect restoration approaches are increasingly favored, particularly as digital dentistry becomes more prevalent. To illustrate this, we present a case report demonstrating the efficacy of hybrid ceramic fragments fabricated using computer-aided design (CAD)/computer-aided manufacturing (CAM) technology and cemented with resin cement in treating non-carious cervical lesions over a 48-month follow-up period. A 24-year-old male patient sought treatment for aesthetic concerns and dentin hypersensitivity in the cervical region of the lower premolar teeth. Clinical examination confirmed the presence of two non-carious cervical lesions in the buccal region of teeth #44 and #45. The treatment plan involved indirect restoration using CAD/CAM-fabricated hybrid ceramic fragments as a restorative material. After 48 months, the hybrid ceramic material exhibited excellent adaptation and durability provided by the CAD/CAM system. This case underscores the effectiveness of hybrid ceramic fragments in restoring non-carious cervical lesions, highlighting their long-term stability and clinical success.

Full-mouth rehabilitation in an amelogenesis imperfecta patient with anterior open bite using CAD/CAM system (전치부 개방교합을 보이는 법랑질형성부전증 환자의 CAD/CAM system을 이용한 전악 수복 증례)

  • Lee, Sang-Hoon;Yi, Yang-Jin;Jo, Deuk-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.410-418
    • /
    • 2017
  • Amelogenesis imperfecta characterized as abnormally formed enamel is caused by a defect of unique group of genes. Patients affected by this disease might have difficulties in social and psychological aspects due to non-esthetic teeth as well as functional problems caused by enamel detachment and tooth wear from their early ages. Adult patients with amelogenesis imperfecta can be treated with full-mouth restorations, which make functional and esthetic rehabilitations of severely worn tooth. However, the anterior open bite and lack of occlusal clearance for posterior teeth restorations due to compensatory extrusion are the intervening factors in the prosthetic treatment. Therefore, the determination of anterior tooth lengths, vertical dimension, and anterior guidance should be set carefully. Recently, computer-aided design and computer-aided manufacturing (CAD/CAM) techniques help systematic approaches and enable dentists to reduce time-consuming procedures in the diagnosis and treatment of full-mouth rehabilitation. This case report demonstrates the successful full mouth rehabilitation using a CAD/CAM system in a young adult patient with amelogenesis imperfecta and anterior open bite.

The Development of Small and Medium Watergate Design System to the CIM Basement (CIM 기반용 중.소형 수문설계시스템 개발)

  • 성백섭;박창언;김일수;김인주;차용훈;김성현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.330-335
    • /
    • 2001
  • Characteristics of the present world market include demanding and sophisticated customers, requirement of high quality and innovative products, greater product diversity, increasing labour and products costs, availability of diverse alternatives to the customers and smaller batch sizes to satisfy a variety of customer profiles. To fulfil these characteristics, manufacturing companies need to be flexible adaptable, proactive and able to produce variety of products in short time at low cost. The aim of the study is to develop a computer-aided design system for water-gate on AutoCAD R2000 system. The developed system has been written in AutoCAD and VisualLISP with a personal computer, and is composed four modules which are the gate-lifter input module, guide-frame input module, and upgrade module. Based on knowledge-based rules, the system is designed by considering several factors, such as width and height of a water-gate, material, object of product and maximum depth of water.

  • PDF

Development of the Design System for a Small and Medium Watergate (중소형 수문 설계 시스템 개발)

  • 김인주;김일수;박창언;성백섭;송창재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.535-539
    • /
    • 2001
  • The aim of this paper presents to develop a computer-aided design system for water gate on AutoCAD R2000system. The developed system has been written in AutoCAD and Visua ILISP with a personal computer, and is composed four modules which are the gate-lifter input module, guide-frame input module, template input module and upgrade module. Based on knowledge-based rules, the system is designed by considering several factors, such as width and height of a water gate, material, object of product and maximum depth of water. Employing the developed system enable the designer and manufactures of water gate to be more efficient in this field, and its potential capability for enhancement included FEM(Finite Element Method) and quotation system.

  • PDF

Computer-aided design of control loop diagrams

  • Matsunaga, Kiyoshi;Shinoda, Takuya
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10a
    • /
    • pp.807-811
    • /
    • 1987
  • This paper describes the application of CAD/CAM systems to the sales and order entry/engineering stages as well as the design of control systems. Large quantities of drawings are required, and the use of graphic CAD systems can result in considerable savings. Some applications of CAD to system engineering/system generation are described.

  • PDF

Full-mouth rehabilitation of a patient with loss of posterior support and collapsed occlusion utilizing dental CAD-CAM system (구치부 지지 소실 및 무너진 교합관계를 보이는 환자에서 Dental CAD-CAM system을 활용한 완전 구강 회복 증례)

  • Jung, Jiwon;Heo, Seong-Joo;Kim, Seong-Kyun;Koak, Jai-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.44-54
    • /
    • 2022
  • Without proper treatment on the multiple tooth missing area, the lack of posterior support and the supra-eruption of the teeth cause many severe complications of occlusion, vertical dimension and masticatory function. This report is a case of full-mouth rehabilitation of a patient with loss of posterior support and collapsed occlusion due to missing teeth area left untreated for a long time. The patient who is 68-year old male patient had some teeth fallen out while removing his old maxillary denture and was complaining about pain in the region of anterior teeth due to traumatic contact. The vertical dimension was corrected by 4 mm from the top cervical point of the canine through various evaluations and the edentulous area was treated with the implant fixed prostheses through computer guided implant surgery based on the diagnosis and treatment plan for definitive prostheses supported by computed tomography (CT) data analysis and CAD-CAM (Computer-aided design/computer-aided manufacturing) technique. After full mouth rehabilitation, the patient was very satisfied with remarkable improvements in mastication, function, and aesthetics.

A Study on Development of the Water-gate Design System for CIM Basement (CIM 기반을 위한 수문설계 시스템 개발에 관한 연구)

  • 김일수;박창언;송창재
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.416-421
    • /
    • 2000
  • Today, manufacturing market is highly competitive due to more complex and variable products, shorter delivery lead times, intensified product development rate, customers's increasing concern about quality, durability, maintainability, safety and environmental performance. To survive this environment, development of the automated design system is needed using AutoCAD. This paper represents a computer aided design system for watergate by using AutoCAD R2000 system and its Visual LISP computer language. The developed system ultimately generates the design for water gate through AutoCAD.

  • PDF

A computer aided two-dimensional analysis of MOSFET and large signal modeling (Computer에 의한 MOSFET의 2차원적 해석과 large signal modeling에 관한 연구)

  • 손일헌;우형주
    • 전기의세계
    • /
    • v.28 no.8
    • /
    • pp.51-56
    • /
    • 1979
  • MOSFET의 모델을 설정하여 여러 bias 조건하에서 연결방정식과 Poisson 방정식을 numerical method로 풀어 그 해로서 전자와 정공의 분포와 전위분포를 구하였으며 또한 그 결과를 종래의 analytic한 이론들과 비교하여 보다 정확하고 CAD(Computer Aided Design)에 적합한 모델을 제안하였다.

  • PDF

Computer-aided design and manufacturing-based full mouth rehabilitation for a patient with excessive attrition and restricted vertical dimension: A case report (심한 치아 마모와 수복 공간 부족을 보이는 환자에서 CAD/CAM 기술을 활용한 완전 구강 회복: 증례 보고)

  • Cho, Jun-Ho;Yoon, Hyung-In;Yeo, In-Sung;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.495-505
    • /
    • 2019
  • This study reported the treatment of a patient with excessive worn dentition and limited maxillo-mandibular space for restoration, utilizing the computer-aided design and computer-aided manufacturing (CAD/CAM) technology. After the thorough examination of the patient's occlusal vertical dimension (OVD), full mouth rehabilitation was planned with increase of the OVD. The patient was satisfied with the provisional restorations establishing the increased OVD. The horizontal and vertical data of the patient's jaw relation that the provisional restorations contained were transferred to the definitive metal ceramic fixed prostheses by double scanning and three-dimensional printing. After the fixed restorations were cemented to the abutments, electronic surveying and three-dimensional printing were used to fabricate metal frameworks for the patient's removable partial dentures. The mandibular definitive removable prostheses were delivered to the patient's mouth and the full mouth rehabilitation procedures were completed. The digital technologies used for this case produced fixed and removable restorations satisfactory in masticatory, phonetic and aesthetic functions to both the patient and the dental clinician.

Effect of different tooth preparation designs on the marginal and internal fit discrepancies of cobalt-chromium crowns produced by computer-aided designing and selective laser melting processes

  • Yu, Na;Dai, Hong-Wei;Tan, Fa-Bing;Song, Jin-Lin;Ma, Chao-Yi;Tong, Xue-Lu
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.5
    • /
    • pp.333-342
    • /
    • 2021
  • PURPOSE. To evaluate the impact of five different tooth preparation designs on the marginal and internal fit discrepancies of cobalt-chromium (CoCr) crowns produced by computer-aided designing (CAD) and selective laser melting (SLM) processes. MATERIALS AND METHODS. Five preparation data were constructed, after which design crowns were obtained. Actual crowns were fabricated using an SLM process. After the data of actual crowns were obtained with structural light scanning, intaglio surfaces of the design crown and actual crown were virtually superimposed on the preparation. The fit-discrepancies were displayed with colors, while the root means square was calculated and analyzed with one-way analysis of variance (ANOVA), Tukey's test or Kruskal-Wallis test (α = .05). RESULTS. The marginal or internal color-coded images in the five design groups were not identical. The shoulder-lip and sharp line angle groups in the CAD or SLM process had larger marginal or internal fit discrepancies compared to other groups (P < .05). In the CAD process, the mean marginal and internal fit discrepancies were 10.0 to 24.2 ㎛ and 29.6 to 31.4 ㎛, respectively. After the CAD and SLM processes, the mean marginal and internal fit discrepancies were 18.4 to 40.9 ㎛ and 39.1 to 47.1 ㎛, respectively. The SLM process itself resulted in a positive increase of the marginal (6.0 - 16.7 ㎛) and internal (9.0 - 15.7 ㎛) fit discrepancies. CONCLUSION. The CAD and SLM processes affected the fit of CoCr crowns and varied based on the preparation designs. Typically, the shoulder-lip and sharp line angle designs had a more significant effect on crown fit. However, the differences between the design groups were relatively small, especially when compared to fit discrepancies observed clinically.