• Title/Summary/Keyword: Computed tomography(CT), quantitative

Search Result 153, Processing Time 0.034 seconds

Development of Triaxial Cells Operable with In Situ X-ray CT for Hydro-Mechanical Laboratory Testing of Rocks (원위치 X-ray CT 촬영이 가능한 암석의 수리-역학 실험용 삼축셀 개발)

  • Zhuang, Li;Yeom, Sun;Shin, Hyu-Soung
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.9
    • /
    • pp.45-55
    • /
    • 2020
  • X-ray computed tomography (CT) is very useful for the quantitative evaluation of internal structures, particularly defects in rock samples, such as pores and fractures. In situ CT allows 3D imaging of a sample subjected to various external treatments such as loading and therefore enables observation of changes that occur during the loading process. We reviewed state-of-the-art of in situ CT applications for geomaterials. Two triaxial cells made using relatively low density but high strength materials were developed aimed at in situ CT scanning during hydro-mechanical laboratory testing of rocks. Preliminary results for in situ CT imaging of granite and sandstone samples with diameters ranging from 25 mm to 50 mm show a resolution range of 34~105 ㎛ per pixel pitch, indicating the feasibility of in situ CT observations for internal structural changes in rocks at the micrometer scale. Potassium iodide solution was found to improve the image contrast, and can be used as an injection fluid for hydro-mechanical testing combined with in situ CT scanning.

Reduced Regional Cerebral Blood Flow in Patients with Traumatic Brain Injury Who Had No Structural Abnormalities on Magnetic Resonance Imaging : A Quantitative Evaluation of Tc-99m-ECD SPECT Findings (정상 MRI 소견을 보이는 외상성 뇌손상 환자에서 국소뇌혈류량의 이상)

  • Kim, Nam-Hee;Chung, Young-Ki
    • Korean Journal of Biological Psychiatry
    • /
    • v.9 no.2
    • /
    • pp.152-158
    • /
    • 2002
  • Background & Purpose:Neuropsychological disorders after traumatic brain injury(TBI) are poorly correlated with structural lesions detected by structural neuroimaging techniques such as computed tomography(CT) scan or magnetic resonance imaging(MRI). It is well known that patients with TBI have cognitive and behavioral disorders even in the absence of structural lesions of the brain. This study investigated whether there are abnormalities of regional cerebral blood flow(rCBF) in TBI patients without structural abnormality on MRI, using technetium 99m ethyl cysteinate dimer(Tc-99m-ECD) single photon emission computed tomography(SPECT) scans. Materials and Methods:Twenty-eight TBI patients without structural abnormality on MRI(mild, n=13/moderate, n=9/severe, n=6) and fifteen normal controls were scanned by SPECT. A voxel-based analysis using statistical parametric mapping(SPM) was performed to compare the patients with the normal controls. Results:rCBF was reduced in the right uncus and the right lateral orbitofrontal gyrus in the TBI patients. However, no increase of rCBF was noted in the patients in comparison to the normal controls. Conclusions:These results suggest that the TBI patients, even in the absence of structural lesion of the brain, may have dysfunction of the brain, particularly of the orbitofrontal and anterior pole of the temporal cortex. They also suggest that SPECT can be a useful method to identify brain dysfunctions in combination with structural brain imaging and neuropsychological tests.

  • PDF

Evaluation on usefulness of three dimensional reconstructive computed tomography images after pedicle screws fixation (척추경 나사못 고정술 시행 후 3차원 재구성CT영상의 유용성 평가)

  • Kim, Hyeon-Ju;Jang, Hyun-Chul;Cho, Jae-Hwan
    • Journal of Digital Contents Society
    • /
    • v.11 no.4
    • /
    • pp.553-559
    • /
    • 2010
  • By applying the various reformation techniques by using a circle raw data of after computed tomography image in the patient enforcing the spine screw fixation, this research tried to look into the various information including the exact location of the position of the screw spike and accuracy of an operation. In a clinical, by applying the or multi planar reformatting(MPR), that is the re-composition technique used mainly, maximum intensity projection (MIP), and volume rendering technique(VRT) and transformation removal from a register modifying VRT, video data were compared and were analyzed by the quantitative method and qualitative method. It is judged as the transformation volume rendering technique of the re-composition technique which is most useful in minimizing the artifact shadow by the exact location of the position of a screw and metal among the analysis and evaluation result computed tomography image reformation technique of the reformation image after the spine screw fixation.

Optimizing the reconstruction filter in cone-beam CT to improve periodontal ligament space visualization: An in vitro study

  • Houno, Yuuki;Hishikawa, Toshimitsu;Gotoh, Ken-ichi;Naitoh, Munetaka;Mitani, Akio;Noguchi, Toshihide;Ariji, Eiichiro;Kodera, Yoshie
    • Imaging Science in Dentistry
    • /
    • v.47 no.3
    • /
    • pp.199-207
    • /
    • 2017
  • Purpose: Evaluation of alveolar bone is important in the diagnosis of dental diseases. The periodontal ligament space is difficult to clearly depict in cone-beam computed tomography images because the reconstruction filter conditions during image processing cause image blurring, resulting in decreased spatial resolution. We examined different reconstruction filters to assess their ability to improve spatial resolution and allow for a clearer visualization of the periodontal ligament space. Materials and Methods: Cone-beam computed tomography projections of 2 skull phantoms were reconstructed using 6 reconstruction conditions and then compared using the Thurstone paired comparison method. Physical evaluations, including the modulation transfer function and the Wiener spectrum, as well as an assessment of space visibility, were undertaken using experimental phantoms. Results: Image reconstruction using a modified Shepp-Logan filter resulted in better sensory, physical, and quantitative evaluations. The reconstruction conditions substantially improved the spatial resolution and visualization of the periodontal ligament space. The difference in sensitivity was obtained by altering the reconstruction filter. Conclusion: Modifying the characteristics of a reconstruction filter can generate significant improvement in assessments of the periodontal ligament space. A high-frequency enhancement filter improves the visualization of thin structures and will be useful when accurate assessment of the periodontal ligament space is necessary.

A Measurement Method for Cervical Neural Foraminal Stenosis Ratio using 3-dimensional CT (3차원 컴퓨터단층촬영상을 이용한 신경공 협착률 측정방법)

  • Kim, Yon-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.975-980
    • /
    • 2020
  • Cervical neural foraminal stenosis is a very common spinal disease that affects a relatively large number of people of all ages. However, since imaging methods that quantitatively provide neural foraminal stenosis are lacking, this study attempts to present quantitative measurement results by reconstructing 3D computed tomography images. Using a 3D reconstruction software, the surrounding bones were removed, including the spinous process, transverse process, and lamina of the cervical spine so that the neural foramen were well observed. Using Image J, a region of interest including the neural foramen area of the 3D image was set, and the number of pixels of the neural foramen area was measured. The neural foramen area was calculated by multiplying the number of measured pixels by the pixel size. In order to measure the widest area of the neural foramen, it was measured between 40-50 degrees in the opposite direction and 15-20 degrees toward the head. The measured cervical neural foramen area showed consistent measurement values. The largest measured area of the right neural foramen C5-6 was 12.21 ㎟, and after 2 years, the area was measured to be 9.95 ㎟, indicating that 18% stenosis had progressed. Since 3D reconstruction using axial CT scan images, no additional radiation exposure is required, and the area of stenosis can be objectively presented. In addition, it is good to explain to patients with neural stenosis while viewing 3D images, and it is considered a good method to be used in the evaluation of the progression of stenosis and post-operative evaluation.

Usefulness of Bone SPECT/CT for Predicting Avascular Necrosis of the Femoral Head in Children with Slipped Capital Femoral Epiphysis or Femoral Neck Fracture

  • Yoo Sung Song;Won Woo Lee;Moon Seok Park;Nak Tscheol Kim;Ki Hyuk Sung
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.264-270
    • /
    • 2022
  • Objective: This study aimed to investigate the usefulness of bone single-positron emission tomography/computed tomography (SPECT/CT) of the hip in predicting the later occurrence of avascular necrosis (AVN) after slipped capital femoral epiphysis (SCFE) or femoral neck fracture in pediatric patients. The quantitative parameters of SPECT/CT useful in predicting AVN were identified. Materials and Methods: Twenty-one (male:female, 10:11) consecutive patients aged < 18 years (mean age ± standard deviation [SD], 11.0 ± 2.7 years) who underwent surgery for SCFE or femoral neck fracture and postoperative bone SPECT/CT were included. The maximum standardized uptake value (SUV), mean SUV, and minimum SUV of the femoral head were measured. The ratios of the maximum SUV, mean SUV, and minimum SUV of the affected femoral head to the contralateral side were determined. Patients were followed up for > 1 year after the surgery. The SPECT/CT parameters were compared between patients who developed AVN and those who did not. The accuracy of SPECT/CT parameters for predicting AVN was assessed. Results: Six patients developed AVN. There was a significant difference in the ratio of the mean SUV among patients who developed AVN (mean ± SD, 0.8 ± 0.3) and those who did not (1.1 ± 0.2, p = 0.018). However, there were no significant differences in the ratios of the maximum and minimum SUV between the groups (all p = 0.205). For the maximum, mean, and minimum SUVs, no significant differences were observed between the groups (p = 0.519, 0.733, and 0.470, respectively). The cutoff mean SUV ratio of 0.87 yielded a 66.7% sensitivity and 93.2% specificity for predicting AVN. Conclusion: Quantitative bone SPECT/CT is useful for evaluating femoral head viability in pediatric patients with SCFE or femoral neck fractures. Clinicians should consider the high possibility of later AVN development in patients with a decreased mean SUV ratio.

Prognostic Implication of Volumetric Quantitative CT Analysis in Patients with COVID-19: A Multicenter Study in Daegu, Korea

  • Byunggeon Park;Jongmin Park;Jae-Kwang Lim;Kyung Min Shin;Jaehee Lee;Hyewon Seo;Yong Hoon Lee;Jun Heo;Won Kee, Lee;Jin Young Kim;Ki Beom Kim;Sungjun Moon;Sooyoung, Choi
    • Korean Journal of Radiology
    • /
    • v.21 no.11
    • /
    • pp.1256-1264
    • /
    • 2020
  • Objective: Lung segmentation using volumetric quantitative computed tomography (CT) analysis may help predict outcomes of patients with coronavirus disease (COVID-19). The aim of this study was to investigate the relationship between CT volumetric quantitative analysis and prognosis in patients with COVID-19. Materials and Methods: CT images from patients diagnosed with COVID-19 from February 18 to April 15, 2020 were retrospectively analyzed. CT with a negative finding, failure of quantitative analysis, or poor image quality was excluded. CT volumetric quantitative analysis was performed by automated volumetric methods. Patients were stratified into two risk groups according to CURB-65: mild (score of 0-1) and severe (2-5) pneumonia. Outcomes were evaluated according to the critical event-free survival (CEFS). The critical events were defined as mechanical ventilator care, ICU admission, or death. Multivariable Cox proportional hazards analyses were used to evaluate the relationship between the variables and prognosis. Results: Eighty-two patients (mean age, 63.1 ± 14.5 years; 42 females) were included. In the total cohort, male sex (hazard ratio [HR], 9.264; 95% confidence interval [CI], 2.021-42.457; p = 0.004), C-reactive protein (CRP) (HR, 1.080 per mg/dL; 95% CI, 1.010-1.156; p = 0.025), and COVID-affected lung proportion (CALP) (HR, 1.067 per percentage; 95% CI, 1.033-1.101; p < 0.001) were significantly associated with CEFS. CRP (HR, 1.164 per mg/dL; 95% CI, 1.006-1.347; p = 0.041) was independently associated with CEFS in the mild pneumonia group (n = 54). Normally aerated lung proportion (NALP) (HR, 0.872 per percentage; 95% CI, 0.794-0.957; p = 0.004) and NALP volume (NALPV) (HR, 1.002 per mL; 95% CI, 1.000-1.004; p = 0.019) were associated with a lower risk of critical events in the severe pneumonia group (n = 28). Conclusion: CRP in the mild pneumonia group; NALP and NALPV in the severe pneumonia group; and sex, CRP, and CALP in the total cohort were independently associated with CEFS in patients with COVID-19.

Evaluation of Merkel Cell Carcinoma Metastasis Using Positron Emission Topography/CT (양전자방출단층촬영술(PET/CT)을 이용한 메르켈 세포암(Merkel cell carcinoma)의 전이 평가)

  • Kwon, Soon Hong;Song, Jin Kyung;Yoo, Gyeol;Byeon, Jun Hee
    • Archives of Plastic Surgery
    • /
    • v.33 no.2
    • /
    • pp.233-236
    • /
    • 2006
  • Merkel cell carcinoma is rare skin malignancy originated from epidermal mechanoreceptor of neural origin. The tumor usually affects older individuals at sun exposed area such as head, neck and extremity. Subclinical involvement of regional lymph node is reported frequently at the time of initial treatment. Thus even asymptomatic patients who present with clinically localized tumor should undergo evaluation with computed tomography and lymphangiography. Positron emission tomography(PET) scans can imaging the metabolic difference of malignant tumors. Increased glucose uptake of malignant tumor cells are detected by PET scanner. PET scans can provide qualitative and quantitative informations about systemic metastasis of tumors. Although there are no data that define the efficacy of PET scans in the initial diagnostic evaluation of head and neck cancer, they could be considered. Current standards of treatment of Merkel cell carcinoma is wide surgical excision and regional lymphadenectomy if there are suspicious lymph nodes. The author reported a patient with Merkel cell carcinoma of cheek. Wide surgical excision and postoperative PET/CT was done for evaluation of regional lymph node and distant metastasis. There were two hot-uptakes in patient's neck, so they were considered as metastatic node, but finally they were proved to be tuberculosis lymphadenitis after excision.

Quantification of the tug-back by measuring the pulling force and micro computed tomographic evaluation

  • Jeon, Su-Jin;Moon, Young-Mi;Seo, Min-Seock
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.273-281
    • /
    • 2017
  • Objectives: The aims of this study were to quantify tug-back by measuring the pulling force and investigate the correlation of clinical tug-back pulling force with in vitro gutta-percha (GP) cone adaptation score using micro-computed tomography (${\mu}CT$). Materials and Methods: Twenty-eight roots from human single-rooted teeth were divided into 2 groups. In the ProTaper Next (PTN) group, root canals were prepared with PTN, and in the ProFile (PF) group, root canals were prepared using PF (n = 14). The degree of tug-back was scored after selecting taper-matched GP cones. A novel method using a spring balance was designed to quantify the tug-back by measuring the pulling force. The correlation between tug-back scores, pulling force, and percentage of the gutta-percha occupied area (pGPOA) within apical 3 mm was investigated using ${\mu}CT$. The data were analyzed using Pearson's correlation analysis, one-way analysis of variance (ANOVA) and Tukey's test. Results: Specimens with a strong tug-back had a mean pulling force of 1.24 N (range, 0.15-1.70 N). This study showed a positive correlation between tug-back score, pulling force, and pGPOA. However, there was no significant difference in these factors between the PTN and PF groups. Regardless of the groups, pGPOA and pulling force were significantly higher in the specimens with a higher tug-back score (p < 0.05). Conclusions: The degree of subjective tug-back was a definitive determinant for master cone adaptation in the root canal. The use of the tug-back scoring system and pulling force allows the interpretation of subjective tug-back in a more objective and quantitative manner.

A Phantom Study for the Optimal Low-dose Protocol in Chest Computed Tomography Examination (흉부 전산화단층촬영검사를 위한 최적의 저선량 프로토콜에 관한 팬텀연구)

  • Kim, Young-Keun;Yang, Sook;Wang, Tae-uk;Kim, Eun-Hye
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.101-107
    • /
    • 2021
  • The purpose of this study was to evaluate optimal CT scan parameters to minimize patient dose to the irradiation and maintain satisfactory image quality in low-dose chest computed tomography (CT) scans. In a chest anthropomorphic phantom, chest CT scans were performed at different kVp and mA within reference of 3.4mGy in volume CT Dose Index (CTDIvol). The following quantitative parameters had been statistically evaluated: image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM). Nine radiographers conducted the blind test to select the optimal kVp-mA combination. Results indicated that the kVp-mA combination of 80kVp-90mA, 100kVp-50mA, 120kVp-30mA and 140kVp-30mA were obtained high SNR and CNR. The 120kVp-30mA combination offered good compromise in the FOM, which showed the quality and dose performance. In the blind test, an image of 80kVp-90mA obtained a high score with 4.7 points, and 120kVp-10mA or 140kVp-10mA with a low tube current were observed severe noise and poor image quality, thus resulting in decreased diagnostic accuracy. On the other hand, in the combination of high kVp and high mA(140kVp-90mA), the image quality was improved, but the radiation dose was also increased. the FOM value of 140kVp-90mA was lower than 120kVp-30mA. The application of appropriate scan parameters in low-dose chest CT scans produced satisfactory results in dose and image quality for the accuracy of the clinical diagnosis.