• Title/Summary/Keyword: Computed tomography(CT), quantitative

Search Result 153, Processing Time 0.041 seconds

A Size Change of Bone Defect Area after Autogenous Calvarial Bone Graft (자가 머리뼈 이식 후 뼈결손부의 면적 변화)

  • Hyun, Kyung Bae;Kim, Dong Suk;Yoo, Sun Kook;Kim, Hee Joung;Kim, Yong Oock;Park, Be-young Yun
    • Archives of Plastic Surgery
    • /
    • v.32 no.4
    • /
    • pp.467-473
    • /
    • 2005
  • Calvarial bone grafting in craniomaxillofacial trauma and facial reconstructive surgery is now widely recognized and accepted as a standard procedure. One of the commonly reported problems of calvarial bone graft is the contour defect caused by partial resorption of the graft. But, there are few reports that discuss the fate of the calvarial bone graft based on the quantitative data. In this article, the changes of grafted calvarial bone were evaluated using 3-dimensional computed tomography(CT). 9 patients were observed with the CT scans at 2mm thickness immediately after operation and at the time of last follow-up. The area of the bone defect was segmented on the 3-dimensional CT image and calculated by AnalyzeDirect 5.0 software. The immediate postoperative bone defect area of the recipient site and the donor site were $612.9mm^2$ and $441.5mm^2$, respectively, which became $1028.1mm^2$ and $268.8mm^2$, respectively at the last follow-up. In conclusion, the bone defect area was less increased on the donor site of calvarial bone graft than on the recipient site. And the CT scan is a valuable imaging method to assess and follow-up the clinical outcome of calvarial bone grafting.

Quantitative CT Evaluation for Lung Volume and Density in Dogs (개에서 정량적 컴퓨터단층촬영을 이용한 폐용적과 폐밀도의 평가)

  • Choi, Soo-Young;Lee, In;Jeong, Woo-Chang;Heng, Hock Gan;Lee, Young-Won;Choi, Ho-Jung
    • Journal of Veterinary Clinics
    • /
    • v.31 no.5
    • /
    • pp.376-381
    • /
    • 2014
  • In this study, we analyzed the computed tomography (CT) measurements of lung volume and density in dogs with relation to body weight, age, sex, and breed. The multi-detector CT examination of the thorax was performed on dogs without respiratory or cardiovascular diseases. Three-dimensional reconstruction of CT images facilitated measurement of lung volume and density. There was a statistical significant correlation between body weight and lung volume (p < 0.0001). Lung density significantly decreased with an increase in body weight (p = 0.0078). However, no correlation was seen between these lung parameters and either sex or age of the dogs. In conclusion, this study shows that body weight is an important factor to consider when interpreting total lung volume and density values measured by quantitative CT. We highlight the need for further study using quantitative CT in identifying the potential effects of sex, age, and disease status on these parameters.

COMPARATIVE HISTOMORPHOMETRIC ANALYSIS OF MANDIBLE AND ILIAC BONE ON BONE DENSITY (하악골과 장골의 조직형태계측 비교)

  • Yoo, So-Jeong;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.1
    • /
    • pp.12-25
    • /
    • 2000
  • To demonstrate possible influences of general bone density on the mandible, histomorphometric analysis was carried out in mandibles and iliac bones and the correlation of the two bone densities was tested. Comparison of bony density in women and men over 60 years in the mandible was carried out too. Quantitative computed tomography(QCT) was taken in cross-section of mandibles at the same site where histomorphometric analysis was peformed to evaluate the reliability of QCT. The analysis included 40 cadavers with no known diseases affecting the bones. The subjects consisted of 15 females and 25 males with a mean age of 60.3 years. Spearman correlation analysis and Wilcoxon rank sum test was performed. The results were as follows. 1. There was statistically no correlation between the mandible and iliac bone in the values of corrected cortical width(CCW), cortical porosity(POR) in cortex, and total bone volume(TBV), mean trabecular plate thickness(MTPT), mean trabecular plate density(MTPD), and mean trabecular plate separation(MTPS) in trabecular bone. 2. Comparison of women and men over 60 years, men had statistically higher bone density than women except fir POR of buccal and lingual cortex, and WTPD of alveolar trabeculae in mandible. 3. There was statistically significant correlation between TBV of trabecular bone and CT No., but not between POR and CT No. in mandible. According to the results above, there was no correlation between mandible and iliac bone density and between mandibular bony density and age. Further studies are required to support the results. A more noninvasive method to be able to measure the bone density of mandible should be developed and it is necessary to accumulate data on the normal values of bone density of mandible according to age and sex. Further study should be carried out about QCT to measure mandibular bony density using QCT.

  • PDF

Quantitative Analysis of Developmental Process of Cranial Suture in Korean Infants

  • Sim, Sook-Young;Yoon, Soo-Han;Kim, Sun-Yong
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.1
    • /
    • pp.31-36
    • /
    • 2012
  • Objective : The purpose of this study was to elucidate the anatomical development of physiologic suture closure processes in infants using three dimensional reconstructed computed tomography (CT). Methods : A consecutive series of 243 infants under 12 months of age who underwent three dimensional CT were included in this study. Four major cranial sutures (sagittal, coronal, lambdoidal and metopic suture) were classified into four suture closure grades (grade 0=no closure along the whole length, grade 1=partial or intermittent closure, grade 2=complete closure with visible suture line, grade 3=complete fusion (ossification) without visible suture line), and measured for its closure degree (suture closure rates; defined as percentage of the length of closed suture line divided by the total length of suture line). Results : Suture closure grade under 12 months of age comprised of grade 0 (n=195, 80.2%), grade 1 (n=24, 9.9%) and grade 2 (n=24, 9.9%) in sagittal sutures, whereas in metopic sutures they were grade 0 (n=61, 25.1%), grade 1 (n=167, 68.7%), grade 2 (n=6, 24%) and grade 3 (n=9, 3.7%). Mean suture closure rates under 12 months of age was 58.8% in metopic sutures, followed by coronal (right : 43.8%, left : 41.1%), lambdoidal (right : 27.2%, left : 25.6%) and sagittal sutures (15.6%), respectively. Conclusion : These quantitative descriptions of cranial suture closure may help understand the process involved in the cranial development of Korean infants.

Median Modified Wiener Filter for Noise Reduction in Computed Tomographic Image using Simulated Male Adult Human Phantom (시뮬레이션된 성인 남성 인체모형 팬텀을 이용한 전산화단층촬영 에서의 노이즈 제거를 위한 Median Modified Wiener 필터)

  • Ju, Sunguk;An, Byungheon;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.21-28
    • /
    • 2021
  • Computed tomography (CT) has the problem of having more radiation exposure compared to other radiographic apparatus. There is a low-dose imaging technique for reducing exposure, but it has a disadvantage of increasing noise in the image. To compensate for this, various noise reduction algorithms have been developed that improve image quality while reducing the exposure dose of patients, of which the median modified Wiener filter (MMWF) algorithm that can be effectively applied to CT devices with excellent time resolution has been presented. The purpose of this study is to optimize the mask size of MMWF algorithm and to see the excellence of noise reduction of MMWF algorithm for existing algorithms. After applying the MMWF algorithm with each mask sizes set from the MASH phantom abdominal images acquired using the MATLAB program, which includes Gaussian noise added, and compared the values of root mean square error (RMSE), peak signal-to-noise ratio (PSNR), coefficient correlation (CC), and universal image quality index (UQI). The results showed that RMSE value was the lowest and PSNR, CC and UQI values were the highest in the 5 x 5 mask size. In addition, comparing Gaussian filter, median filter, Wiener filter, and MMWF with RMSE, PSNR, CC, and UQI by applying the optimized mask size. As a result, the most improved RMSE, PSNR, CC, and UQI values were showed in MMWF algorithms.

CT-based quantitative evaluation of radiation-induced lung fibrosis: a study of interobserver and intraobserver variations

  • Heo, Jaesung;Cho, Oyeon;Noh, O Kyu;O, Young-Taek;Chun, Mison;Kim, Mi-Hwa;Park, Hae-Jin
    • Radiation Oncology Journal
    • /
    • v.32 no.1
    • /
    • pp.43-47
    • /
    • 2014
  • Purpose: The degree of radiation-induced lung fibrosis (RILF) can be measured quantitatively by fibrosis volume (VF) on chest computed tomography (CT) scan. The purpose of this study was to investigate the interobserver and intraobserver variability in CT-based measurement of VF. Materials and Methods: We selected 10 non-small cell lung cancer patients developed with RILF after postoperative radiation therapy (PORT) and delineated VF on the follow-up chest CT scanned at more than 6 months after radiotherapy. Three radiation oncologists independently delineated VF to investigate the interobserver variability. Three times of delineation of VF was performed by two radiation oncologists for the analysis of intraobserver variability. We analysed the concordance index (CI) and inter/intra-class correlation coefficient (ICC). Results: The median CI was 0.61 (range, 0.44 to 0.68) for interobserver variability and the median CIs for intraobserver variability were 0.69 (range, 0.65 to 0.79) and 0.61(range, 0.55 to 0.65) by two observers. The ICC for interobserver variability was 0.974 (p < 0.001) and ICCs for intraobserver variability were 0.996 (p < 0.001) and 0.991 (p < 0.001), respectively. Conclusion: CT-based measurement of VF with patients who received PORT was a highly consistent and reproducible quantitative method between and within observers.

Comparative Analysis of Bone Mineral Contents with Dual-Energy Quantitative Computed Tomography (이중에너지광자선의 전산화단층촬영술을 이용한 정량적 골무기물함량의 비교분석)

  • Choi, Tae-Jin;Yoon, Seon-Min;Kim, Ok-Bae;Lee, Sung-Moon;Suh, Soo-Jhi
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.153-158
    • /
    • 1997
  • Purpose : The Dual-Energy Quantitative Computed Tomography(DEQCT) was compared with bone equivalent $K_2HPO_4$ standard solution and ash weight of animal cadaveric trabecular bone in the measurement of bone mineral contents(BMC). Method and Materials : The attenuation coefficient of tissues highly depends on the radiation energy density and effective atomic number of composition, The bone mineral content of DEQCT in this experiments was determined from empirical constants and mass attenuation coefficients of bone,fat and soft tissue equivalent solution in two photon spectra. In this experiments, the BMC of DEQCT with 80 and $120kV_p$ X rays was compared to ash weight of animal trabecular bone. Results : We obtained the mass attenuation coefficient of 0.2409 0.5608 and 0.2206 in $80kV_p$, and 0.2046, 0.3273 and $0.1971cm^2/g$ in $120kV_p$ X-ray spectra for water bone and fat equivalent materials, respectively. The BMC with DEQCT was acomplished with empirical constants $K_1=0.3232,\;K_2$=0.2450 and mass attenuation coefficients has very closed to ash weight of animal trabecular bone The BMC of empirical DEQCT and that of manufacturing DEQCT were correlated with ash weight as a correlation r= 0.998 and r= 0.996, respectively. Conclusion : The BMC of empirical DEQCT using the experimental mass attenuation coefficients and that of manufacture have showed very close to ash weight of animal trabecular bone.

  • PDF

A Method to Obtain the CT Attenuation Coefficient and Image Noise of Various Convolution Kernels in the Computed Tomography (Convolution Kernel의 종류에 따른 CT 감약계수 및 노이즈 측정에 관한 연구)

  • Kweon, Dae-Cheol;Yoo, Beong-Gyu;Lee, Jong-Seok;Jang, Keun-Jo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.21-30
    • /
    • 2007
  • Our objective was to evaluate the CT attenuation coefficient and noise of spatial domain filtering as an alternative to additional image reconstruction using different kernels in abdominal CT. Derived from thin collimated source images was generated using abdomen B10 (very smooth), B20 (smooth), B30 (medium smooth), B40 (medium), B50 (medium sharp), B60 (sharp), B70 (very sharp) and B80 (ultra sharp) kernels. Quantitative CT coefficient and noise measurements provided comparable HU (hounsfield) units in this respect. CT attenuation coefficient (mean HU) values in the abdominal were 60.4$\sim$62.2 HU and noise (7.6$\sim$63.8 HU) in the liver parenchyma. In the stomach a mean (CT attenuation coefficient) of -2.2$\sim$0.8 HU and noise (10.1$\sim$82.4 HU) was measured. Image reconstructed with a convolution kernel led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image medications of image sharpness and noise eliminate the need for reconstruction using different kernels in the future. CT images increase the diagnostic accuracy may be controlled by adjusting CT various kernels, which should be adjusted to take into account the kernels of the CT undergoing the examination.

  • PDF

Fluid Accumulation in Canine Tympanic Bulla: Radiography, CT and MRI Examinations

  • Lee, Young-Won;Kang, Sang-Kyu;Choi, Ho-Jung
    • Journal of Veterinary Clinics
    • /
    • v.25 no.3
    • /
    • pp.176-181
    • /
    • 2008
  • Fluid accumulation within the tympanic bulla is an important diagnostic indicator of canine otitis media although its identification can be a challenge using currently available imaging techniques. The purpose of this study was to compare radiography, computed tomography (CT) and magnetic resonance imaging (MRI) in the identification of fluid accumulation within canine tympanic bulla. Unilateral tympanic bulla in 10 beagles were experimentally filled with blood or saline. Quantitative analysis of CT images were obtained by using Hounsfield unit (HU). MR signal intensity was obtained by using region of interesting (ROI) and compared with those of gray matter. On the CT image, the presence of blood or saline produced a fluid opacity occupying the tympanic bulla. On the MR image, the appearance of blood in the tympanic bulla was isointense in T1-weighted images and hyperintense in T2-weighted images. However, the appearance of saline in the tympanic bulla was hypointense in T1-weighted images and hyperintense in T2-weighted images. This study suggest that CT and MR imaging are useful methods for detection and differentiation of fluid in canine tympanic bulla.

Intracerebral Hemorrhage Auto Recognition in Computed Tomography Images (CT 영상에서 뇌출혈의 자동인식)

  • Choi, Seok-Yoon;Kang, Se-Sik;Kim, Chang-Soo;Kim, Jung-Hoon;Kim, Dong-Hyun;Ye, Soo-Young;Ko, Seong-Jin
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.141-148
    • /
    • 2013
  • The CT examination sometimes fail to localize the cerebral hemorrhage part depending on the seriousness and may embarrass the pathologist if he/she is not trained enough for emergencies. Therefore, an assisting role is necessary for examination, automatic and quick detection of the cerebral hemorrhage part, and supply of the quantitative information in emergencies. the computer based automatic detection and recognition system may be of a great service to the bleeding part detection. As a result of this research, we succeeded not only in automatic detection of the cerebral hemorrhage part by grafting threshold value handling, morphological operation, and roundness calculation onto the bleeding part but also in development of the PCA based classifier to screen any wrong choice in the detection candidate group. We think if we apply the new developed system to the cerebral hemorrhage patient in his critical condition, it will be very valuable data to the medical team for operation planning.