• Title/Summary/Keyword: Computed muscle control

Search Result 23, Processing Time 0.031 seconds

The Effect of Microcurrent Electrical Stimulation on Muscle Atrophy Suppression in a Sciatic Nerve Injured Rat Model; Comparative Study by Current Intensity (좌골신경손상 쥐 모델을 이용한 미세전류 자극의 근위축 억제 효과 확인 및 자극 세기 별 비교)

  • Hwang, Donghyun;Kim, Seohyun;Lee, Hana;Jang, Seungjun;Kim, Sebin;kim, Tackjoong;Choi, Sooim;Kwak, Hoyoung;Kim, Han Sung
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.4
    • /
    • pp.175-182
    • /
    • 2017
  • Microcurrent electrical stimulation(MES) has been used to accelerate recovery of atrophied skeletal muscle. However, convincing stimulation parameters for suppressing muscle atrophy due to injured sciatic nerve remains unclear. The objective of this study was to investigate the effective intensity of MES on restraining muscle atrophy with rat model underwent sciatic nerve injury(SNI). Twenty-5-week-old Sprague Dawley male rats were equally assigned to five groups : Control group(Control, CON, n = 4), Denervation group(Denervation, D, n = 4), Denervation with MES of $22{\mu}A$ group(Denervation + $22{\mu}A$, D+22, n = 4), Denervation with MES of $100{\mu}A$ group (Denervation + $100{\mu}A$, D+100 n = 4), Denervation with MES of $400{\mu}A$ group(Denervation + $400{\mu}A$, D+400, n = 4). To induce muscle atrophy, all rats in the D, D+22, D+100, and D+400 groups, were subjected to sciatic nerve injury on their right hindlimb and allowed to have 1 week of resting period. Following this period, rats underwent daily MES(60 min/ a day, 5times/1week) for 4 weeks. After that, we investigate morphological changes in muscle volume by using in vivo micro-computed tomography at week 0, 1, 3 and 5. After 5 weeks, the muscle volume had the highest value in D+400 group, and also noticeably increased in D+100 group compared to it in D group. The results of this study imply that MES with current intensities between $100-400{\mu}A$ can suppress muscle atrophy effectively.

Immediate Debridement and Reconstruction with a Pectoralis Major Muscle Flap for Poststernotomy Mediastinitis

  • Jang, Yu-Jin;Park, Myong-Chul;Park, Dong-Ha;Lim, Hyo-Seob;Kim, Joo-Hyoung;Lee, Il-Jae
    • Archives of Plastic Surgery
    • /
    • v.39 no.1
    • /
    • pp.36-41
    • /
    • 2012
  • Background : Poststernotomy mediastinitis is a rare, but life-threatening complication, thus early diagnosis and proper management is essential for poststernotomy mediastinitis. The main treatment for mediastinitis is aggressive debridement. Several options exist for reconstruction of defects after debridement. The efficacy of immediate debridement and reconstruction with a pectoralis major muscle flap designed for the defect immediately after the diagnosis of poststernotomy mediastinitis is demonstrated. Methods : Between September 2009 and June 2011, 6 patients were referred to the Department of Plastic and Reconstructive Surgery and the Department of Thoracic and Cardiovascular Surgery of Ajou University Hospital for poststernotomy mediastinitis. All of the patients underwent extensive debridement and reconstruction with pectoralis major muscle flaps, advanced based on the pedicle of the thoracoacromial artery as soon as possible following diagnosis. A retrospective review of the 6 cases was performed to evaluate infection control, postoperative morbidity, and mortality. Results : All patients had complete wound closures and reduced severity of infections based on the erythrocyte sedimentation rate and C-reactive protein levels and a reduction in poststernal fluid collection on computed tomography an average of 6 days postoperatively. A lack of growth of organisms in the wound culture was demonstrated after 3 weeks. There were no major wound morbidities, such as hematomas, but one minor complication required a skin graft caused by skin flap necrosis. No patient expired after definitive surgery. Conclusions : Immediate debridement and reconstruction using a pectoralis major muscle flap is a safe technique for managing infections associated with poststernotomy mediastinitis, and is associated with minimal morbidity and mortality.

Effects of Transcranial Direct Current Stimulation on Lower Extremity Function of Stroke Patients : A meta-analysis of domastic research (뇌졸중 환자의 다리 기능에 대한 경두개직류자극의 효과: 국내 연구의 메타분석)

  • Lee, Jeong-Woo;Lim, Ji-Sun
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.3
    • /
    • pp.87-97
    • /
    • 2021
  • Purpose : The purpose of this meta-analysis was to evaluate the effects of transcranial direct current stimulation on the lower extremity function of stroke patients. Methods : Domestic data were gathered from studies that conducted clinical trials associated with transcranial direct current stimulation and its impact on lower extremity function of stroke patients. A total of 592 studies published between 2012 and 2020 were identified, with 7 studies satisfying the inclusion data. The studies consisted of patient, intervention, comparison, and outcome (PICO) data. The search outcomes were items associated with muscle activity, balance, muscle strength and walking ability. Cochrane risk of bias (ROB) was used to evaluate the quality of 3 randomized control trials. The quality of 4 non-randomized control trials was evaluated using risk of bias assessment tool for non-randomized studies (RoBANS). Effect sizes in this study were computed as the corrected standard mean difference (SMD). A random-effect model was used to analyze the effect size because of the high heterogeneity among the studies. Egger's regression and 'trim-and-fill' tests were carried out to analyze the publishing bias. Results : The following factors had a large total effect size (Hedges's g=2.10, 95 %CI=1.54~2.66) involving transcranial direct current stimulation on stroke patients: muscle activity (Hedges's g=2.38, 95 %CI=1.08~3.68), balance (Hedges's g4=2.41, 95 %CI=1.33~3.60), walking ability (Hedges's g=1.54, 95 %CI=0.49~2.59), and muscle strength (Hedges's g=2.45, 95 % CI: 0.85~4.05). Egger's regression test showed that the publishing bias had statistically significant differences but 'trim-and-fill' test showed that there was still statistical difference. Conclusion : This study provides evidence for the effectiveness of transcranial direct current stimulation on the lower extremity in terms of muscle activity, balance, walking ability, and muscle strength in stroke patients. However, due to the low quality of studies and high heterogeneity factors, the results of our study should be interpreted cautiously.

Effects of Differential Stability on Control of Multi-Joint Coordination in the Upper Extremity: A Torque Component Analysis

  • Ryu, Young Uk;Shin, Hwa Kyung
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Purpose: The purpose of the present current study was to examine control of upper limb multi-joint movements with differential coordination stability. To achieve the goals of the study, torque analyses were utilized to answer questions about how torque components were differed among various elbow-wrist coordination patterns. Methods: Eight self-reported right-handed college students (3 males and 5 females, mean age=20.6 yr) were volunteered. The task required participants to rhythmically coordinate the flexion-extension motions of their elbow and wrist with coordination relationship of $0^{\circ}$, $90^{\circ}$, and $180^{\circ}$relative phases between the two joints. Mean relative phase and phase stability (standard deviation of relative phase) were computed to for analysisze of overall coordination performance. To determine the figure out characteristics of torque components in elbow and wrist joints, impulse values of muscle torque (MT) and interactive torque (IT) and MT as a percentage of cycle duration (MT-PCD) were analyzed. Results: Torque results showed that the proximal elbow joint generated motions with mainly muscle efforts regardless of coordination patterns, while the distal wrist joint adjusted the coordination patterns by changing amount of MT. Impulse analyses showed that the least stable $90^{\circ}$ pattern was performed by utilizing a similar coordination strategy of the most stable $0^{\circ}$ pattern. Conclusion: The present current study suggests that the roles of distal and proximal joints differ in order to achieve various multi-joint coordination movements. This study provides information for use in gives an idea to development of rehabilitation or training programs for to persons with an impaired upper limb motor ability.

Use of the facial dismasking flap approach for surgical treatment of a multifocal craniofacial abscess

  • Ishii, Yoshitaka;Yano, Tomoyuki;Ito, Osamu
    • Archives of Plastic Surgery
    • /
    • v.45 no.3
    • /
    • pp.271-274
    • /
    • 2018
  • The decision of which surgical approach to use for the treatment of a multifocal craniofacial abscess is still a controversial matter. A failure to control disease progress in the craniofacial region can potentially put the patient's life at risk. Therefore, understanding the various ways to approach the craniofacial region helps surgeons to obtain satisfactory results in such cases. In this report, we describe a patient who visited the emergency department with a large swelling in his right cheek. A blood test and computed tomography revealed odontogenic maxillary sinusitis. The patient developed sepsis due to a progressive multifocal abscess. An abscess was seen in the temporal muscle, infratemporal fossa, and interorbital region. To control this multifocal abscess, we used the facial dismasking flap (FDF) approach. After debridement using the FDF approach, we succeeded in obtaining sufficient drainage of the abscess, and the patient recovered from sepsis. The advantages of the FDF approach are that it provides a wide surgical field, extending from the parietal region to the mid-facial region, and that it leaves no aesthetically displeasing scars on the face. The FDF approach may be one of the best options to approach multifocal abscesses in the craniofacial region.

Age-dependent Difference in the Computed Tomography Numbers of the Normal Parotid Gland of Koreans (나이에 따른 한국인 정상 이하선의 전산화단층촬영값의 차이)

  • Jeong Ho-Gul;Lee Eun-Sook;Kim Kee-Deog;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.451-458
    • /
    • 1999
  • Purpose : To determine normal CT number range of parotid gland by analyzing the change by age increase and the difference among individuals and between both sexes in CT number of normal parotid gland. Materials & Methods : 134 subjects who took the CT scan between the period of Jan. 1996 and Dec. 1997 at Yonsei University, Dental Hospital were selected. Criteria for selection were that the patients must be within the normal range clinically and radiologically, and the entire parotid gland on the axial view must be shown. Among the axial views. the one showing the greatest parotid gland size was selected and its CT number was recorded. Also. CT numbers from both masseter muscle were recorded as its control. Results : There was statistically significant correlation between CT number of right and left of parotid glands and masseter muscles. With the increase of age. there is a significant decrease in the CT number of parotid gland(p<0.05). There was no statistically significant difference in CT number between sexes except the 7th decade and beyond age group of parotid gland(p>0.05). Conclusion : As age increases, CT number of parotid gland has a tendency to decrease, and there is no significant difference in the CT numbers between left and right parotid gland. Therefore in the CT scan of patients suspected of having a salivary gland disease of the parotid gland. to consider normal range of the age-dependent CT numbers of parotid gland and compare the CT numbers of the right and left parotid gland might be useful in diagnosing the disease.

  • PDF

The Effects of Dietary Lysine Deficiency on Muscle Protein Turnover in Postweanling Pigs

  • Chang, Yi-Ming;Wei, Hen-Wei
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.9
    • /
    • pp.1326-1335
    • /
    • 2005
  • The main purpose of this study is to investigate the effects of dietary lysine deficiency on protein turnover of porcine muscles. There were 18 LYD three-breed-crossing postweanling barrows from six litters cannulated with gastric tubes through the esophagus at approximate 10 kg of body weight and allocated into three treatment groups. When their body weights reached over 12 kg, one group was sacrificed for determining the initial protein masses of m. masseter, m. longissimus dorsi, m. adductor and m. biceps femoris from the right body side. The others received a diet containing 100% or 61.4% (calculated values) of the lysine requirement (NRC, 1998) multiplied by 1.103 for a period of 17 days. Daily feed provision was computed for each pig according to body weight at the same day. All pigs were infused a flooding dose of $^2$H$_5$-phenylalanine to determine the fractional protein synthesis rates (FSR) of the aforementioned muscles in the end. Their four muscles from the right body side were also dissected for measuring the fractional rates of protein accretion (FAR). As for protein degradation, fractional rates (FDR) were calculated by differences between synthesis and accretion. Results showed that the lysine deficiency resulted in, significantly (p<0.05), lighter body weights, smaller muscles and a slower growth rate. The protein mass, accreted by the muscles, of the deficient group was only 54% averaged of the pigs fed adequately (p<0.05). The FAR of these muscles in the deficient group was significantly lower (p<0.05) and only achieved 61.1% averaged of the control; there was no significant difference (p>0.05), nevertheless, in the amino-acid composition of muscles between two groups. The lysine deficiency reduced significantly (p<0.05) the FSR of m. longissimus dorsi but did not influence its FDR. The m. biceps femoris also presented an inhibited FSR while its FDR reduced only exhibited a very high tendency (p = 0.055) compared to the adequately-fed pigs. As for the m. masseter and m. adductor, both of the FSR and FDR were depressed significantly (p<0.05) by the lysine deficiency, and changes in the FSR were severer than those in the FDR, so that their FAR were significantly slower (p<0.05) in comparison with the control group. The lysine deficiency also inhibited the RNA translation activity of the muscles while the effects on RNA capacity were not significant (p>0.05). In conclusion, the FAR of muscle protein was changed by the current lysine deficiency through the alterations in the FSR and/or FDR.

Characterization of Nutritional Value for Twenty-one Pork Muscles

  • Kim, J.H.;Seong, P.N.;Cho, S.H.;Park, B.Y.;Hah, K.H.;Yu, L. H.;Lim, D.G.;Hwang, I.H.;Kim, D.H.;Lee, J.M.;Ahn, C.N.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.1
    • /
    • pp.138-143
    • /
    • 2008
  • A study was conducted to evaluate nutritional value for twenty-one pork muscles. Ten market-weight crossbred pigs (five gilts and five barrows) were used for evaluating proximate chemical composition, cholesterol, total iron, calorie and fatty acid contents. As preliminary analysis revealed no noticeable sex effect, pooled data from both sexes were used for the final analysis. M. rectus femoris had the highest moisture content, while m. latissimus dorsi was lowest in moisture content (p<0.05). Protein content was highest for m. longissimus dorsi and lowest for m. supraspinatus (p<0.05). The tensor fasciae and latissimus dorsi muscles contained the highest intramuscular fat (p<0.05), while rectus femoris, adductor and vastus lateralis were lowest in intramuscular fat content. When simple correlations between chemical values were computed for the pooled dataset from all muscles, intramuscular fat had significant (p<0.05) negative linear relationships with moisture (r = -0.85) and protein (r = -0.51) contents. Calorie levels were not significantly affected by fat content, while rectus femoris and latissimus dorsi muscles showed lowest and highest calorie contents, respectively (p<0.05). Polyunsaturated fatty acid content was highest (p<0.05) for both m. adductor and m. rectus femoris, while it was lowest for m. longissimus dorsi. Collectively, the current study identified a large amount of variation in nutritional characteristics between pork muscles, and the data can be used for the development of muscle-specific strategies to improve eating quality of meats and meat products.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Successful Angiographic Embolization of Superficial Circumflex Iliac Artery Rupture Caused by Blunt Abdominal Trauma: A Case Report (복부 둔상에 의한 얕은엉덩휘돌이동맥 파열의 혈관조영색전술을 통한 성공적인 치료: 증례보고)

  • Lee, Sang Bong;Park, Sung Jin;Yeo, Kwang Hee;Kim, Ho Hyun;Park, Chan-Yong;Kim, Jae Hun;Kim, Chang Wan;Choi, Seon Uoo;Kim, Seon Hee;Hwang, Jung Joo;Cho, Hyun Min
    • Journal of Trauma and Injury
    • /
    • v.28 no.1
    • /
    • pp.39-42
    • /
    • 2015
  • Lat. abdominal wall hematoma with active bleeding is very rare but need prompt bleeding control. We report successful treatment by angiographic embolization of superficial circumflex iliac artery rupture caused by blunt trauma. A 60-year-old woman presented painful, enlarging, lat. abdominal wall mass with ecchymosis caused by blunt abdominal trauma. Contrast leakage of superficial circumflex iliac a. within the lt. ext. oblique m. hematoma was confirmed by abdominal computed tomography. Angiographic embolization was performed successfully. Patient was discharged at 4th day after trauma without complication. Angiographic embolization is important treatment option of lat. abdominal wall hematoma with active bleeding replacing emergency surgery.

  • PDF