• 제목/요약/키워드: Compressive stress Loading

검색결과 342건 처리시간 0.027초

The influence of various core designs on stress distribution in the veneered zirconia crown: a finite element analysis study

  • Ha, Seung-Ryong;Kim, Sung-Hun;Han, Jung-Suk;Yoo, Seung-Hyun;Jeong, Se-Chul;Lee, Jai-Bong;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.187-197
    • /
    • 2013
  • PURPOSE. The purpose of this study was to evaluate various core designs on stress distribution within zirconia crowns. MATERIALS AND METHODS. Three-dimensional finite element models, representing mandibular molars, comprising a prepared tooth, cement layer, zirconia core, and veneer porcelain were designed by computer software. The shoulder (1 mm in width) variations in core were incremental increases of 1 mm, 2 mm and 3 mm in proximal and lingual height, and buccal height respectively. To simulate masticatory force, loads of 280 N were applied from three directions (vertical, at a $45^{\circ}$ angle, and horizontal). To simulate maximum bite force, a load of 700 N was applied vertically to the crowns. Maximum principal stress (MPS) was determined for each model, loading condition, and position. RESULTS. In the maximum bite force simulation test, the MPSs on all crowns observed around the shoulder region and loading points. The compressive stresses were located in the shoulder region of the veneer-zirconia interface and at the occlusal region. In the test simulating masticatory force, the MPS was concentrated around the loading points, and the compressive stresses were located at the 3 mm height lingual shoulder region, when the load was applied horizontally. MPS increased in the shoulder region as the shoulder height increased. CONCLUSION. This study suggested that reinforced shoulder play an essential role in the success of the zirconia restoration, and veneer fracture due to occlusal loading can be prevented by proper core design, such as shoulder.

Experimental and numerical investigation of expanded polystyrene (EPS) geofoam samples under monotonic loading

  • Khalaj, Omid;Siabil, Seyed Mohammad Amin Ghotbi;Azizian, Mehran;Tafreshi, Seyed Naser Moghaddas;Masek, Bohuslav;Kepka, Miloslav;Kavalir, Tomas;Krizek, Michal;Jirkova, Hana
    • Geomechanics and Engineering
    • /
    • 제22권6호
    • /
    • pp.475-488
    • /
    • 2020
  • The recent increase in the use of Expanded Polystyrene (EPS) geofoam in construction and geotechnical projects has driven researchers to investigate its behavior, more deeply. In this paper, a series of experimental tests to investigate the stress-strain behavior and the mechanical properties of EPS blocks, under monotonic axial loading are presented. Four different densities of cylindrically shaped EPS with different dimensions are used to investigate the effects of loading rate, height and diameter, as well as the influence of the density of EPS on the stress-strain response. The results show that increasing the height of the EPS samples leads to instability of the sample and consequent lower resistance to the applied pressure. Large EPS samples show higher Young's modulus and compressive resistance due to some boundary effects. An increase in the rate of loading can increase the elastic moduli and compressive resistance of the EPS geofoam samples, which also varies depending on the density of the samples. It was also determined that the elastic modulus of EPS increases with increasing EPS density. By implementing an efficient numerical procedure, the stress-strain response of EPS geofoam samples can be reproduced with great accuracy. The numerical analysis based on the proposed method can used to evaluate the effect of different factors on the behavior of EPS geofoam.

족관절 근위부 골교정용 기능성 체외고정장치 개발 (Development of a Functional External Fixator System for Bone Deformity near Joints in Legs)

  • 이호중;전경진
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.162-169
    • /
    • 2005
  • The functional external fixator system fur bone deformity near joints in legs using the worm gear was developed for curing the difference angles in fracture bone and the lengthening bar for curing the difference length in fracture bone. Both experiments and FE analysis were performed to compare the elastic stiffness in several loading modes and to improve the functional external fixator system for the bone deformity. The FE model using the compressive and bending FE analysis was applied to the FE analysis due to the angle differences. The results show that the compressive stiffness value in experiment was 175.43N/mm; the bending stiffness value in experiment was 259.74N/mm; compressive stiffness value in FEM was 188.67N/mm; bending stiffness value in FEA was 285.71N/mm. The errors between experiments and FEA were less than 10%. The maximum stress (157MPa) to the angle of clamp was lower than the yield stress (176.4MPa) of SUS316L. The stiffnesses in both axial compressive and bending of the new fixator are about 2 times higher than other products except EBI (2003).

족관절 근위부 골교정용 기능성 체외고정장치 개발 (Development of a Functional External Fixator System for Bone Deformity near Joints in Legs)

  • 전경진;이호중
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1248-1251
    • /
    • 2004
  • The functional external fixator system for bone deformity near joints in legs using the worm gear was developed for curing the difference angles in fracture bone and the lengthening bar for curing the difference length in fracture bone. Both experiments and FE analysis were performed to compare the elastic stiffness in several loading modes and to improve the functional external fixator system for bone deformity near joints in legs. The FE model using the compressive and bending FE analysis was applied the FE analysis due to the angle differences. The results show that the compressive stiffness value in experiment was 175.43N/mm, the bending stiffness value in experiment was 259.74N/mm, compressive stiffness value in FEM was 188.67N/mm, bending stiffness value in FEA was 285.71N/mm. The errors between experiments and FEA were less than 10%. The maximum stress (157MPa) to the angle of clamp was lower than the yield stress (176.4MPa) of SUS316L. The stiffnesses in both axial compressive and bending of the new fixator are about 2 times higher than other products except EBI (2003).

  • PDF

Analysis of actively-confined concrete columns using prestressed steel tubes

  • Nematzadeh, Mahdi;Haghinejad, Akbar
    • Computers and Concrete
    • /
    • 제19권5호
    • /
    • pp.477-488
    • /
    • 2017
  • In this paper, an innovative technique for finite element (FE) modeling of steel tube-confined concrete (STCC) columns with active confinement under axial compressive loading is presented. In this method, a new constitutive model for the stress-strain relationship of actively-confined concrete is proposed. In total, 14 series of experimental STCC stub columns having active confinement were modeled using the ABAQUS software. The results obtained from the 3D model including the compressive strength at the initial peak point and failure point, as well as the axial and lateral stress-strain curves were compared with the experimental results to verify the accuracy of the 3D model. It was found that there existed a good agreement between them. A parametric study was conducted to investigate the effect of the concrete compressive strength, steel tube wall thickness, and pre-stressing level on the behavior of STCC columns with active confinement. The results indicated that increasing the concrete core's compressive strength leads to an increase in the compressive strength of the active composite column as well as its earlier failure. Furthermore, a reduction in the tube external diameter-to-wall thickness ratio affects the axial stress-strain curve and the confining pressure, while increasing the pre-stressing level has a negligible effect on the two.

마이크로 X-ray CT를 활용한 알루미늄 개방형 폼의 형상 및 압축 거동 분석 (Analysis of 3D Geometry and Compressive Behavior of Aluminum Open Cell Foam Using X-ray Micro CT)

  • 김영일;김지훈;이종국;김대용
    • 소성∙가공
    • /
    • 제20권7호
    • /
    • pp.518-523
    • /
    • 2011
  • The three dimensional geometries of an aluminum open cell foam before and after uniaxial compressive loading were investigated using the X-ray micro CT(computed tomography). Aluminum 6101-T6 open cell foams of 10, 20, 40 ppi (pore per inch) were considered in this work. After the serial sectioning CT images of aluminum foams were obtained from non-destructive X-ray images, the exact 3D structure were reproduced and visualized with commercial image processing program. The relative density ratio was around the 7.0 to 9.0 range, the unit cells showed anisotropic shapes having the different dimensional ratios of 1.1 to 1.3 between the rise and the transverse directions. The yield stress increased with the relative density ratio and the volumetric strain increased proportionally with compressive strain. The plateau stress in the compressive stress-strain curve was caused by the buckling of ligaments.

Development of a Functional Fixator System for Bone Deformity Near Joints

  • Chun, Keyoung-Jin;Lee, Ho-Jung
    • Journal of Mechanical Science and Technology
    • /
    • 제20권2호
    • /
    • pp.234-241
    • /
    • 2006
  • A functional external fixator system for bone deformity near the joints using worm gear was developed for curing the angle difference in fracture bones while the lengthening bar was developed for curing the differences in length, also in fracture bones. Both experiments and FE analysis were performed to compare the elastic stiffness in several loading modes and to improve the functional external fixator system for bone deformity near joints. The FE model using compressive and bending FE analysis was applied due to the angle differentiations. The results indicate that compressive stiffness value in the experiment was 175.43N/mm, bending stiffness value in the experiment was 259.74 N/mm, compressive stiffness value in the FEA was 188.67 N/mm, and bending stiffness value in the FEA was 285.71 N/mm. Errors between experiments and FEA were less than $10\%$ in both the 'compressive stiffness and the bending stiffness. The maximum stress (157 MPa) applied to the angle of the clamp was lower than the yield stress (176.4 MPa) of SUS316L. The degree of stiffness in both axial compression and bending of the new fixator are about 2 times greater than other products, with the exception of EBI (2003).

고온가열 및 하중재하에 따른 80, 130, 180 MPa 초고강도콘크리트의 역학적특성평가 (Evaluation of Properties of 80, 130, 180 MPa High Strength Concrete at High Temperature with Heating and Loading)

  • 최경철;윤민호;이태규;이승훈;김규용
    • 콘크리트학회논문집
    • /
    • 제25권6호
    • /
    • pp.613-620
    • /
    • 2013
  • 콘크리트는 고온에 강한재료로 인식되어 왔으나, 화재 등의 고온에 의해 내부조직의 물리 화학적 변화가 발생해 역학적 특성이 저하하게 된다. 이에, 고온시 콘크리트의 역학적 특성의 저하에 관한 연구보고 및 기준이 제시되고 있다. 그러나 고강도 콘크리트 및 하중을 재하한 상태에 관한 연구데이터는 적다. 따라서 이 연구에서는 고온 및 하중재하에 따른 고강도 콘크리트의 고온특성을 평가하였다. W/B 12.5%, 14.5%, 20%의 고강도 콘크리트를 대상으로 비재하상태 및 $0.25f_{cu}$의 하중조건을 설정하여, 고온시의 응력-변형, 최대하중에서의 변형, 압축강도, 탄성계수, 열팽창변형, 단기 고온크리프을 평가하였다. 실험 결과, 압축강도가 높아질수록 가열에 의한 압축강도의 저하가 크게 나타났고, $500^{\circ}C$이상의 온도에서 고온에 의한 열팽창변형과 하중재하에 의한 수축변형이 상쇄되어 압축강도 및 탄성계수의 잔존율이 높아지는 것을 확인할 수 있었다.

Compressive behavior of concrete under high strain rates after freeze-thaw cycles

  • Chen, Xudong;Chen, Chen;Liu, Zhiheng;Lu, Jun;Fan, Xiangqian
    • Computers and Concrete
    • /
    • 제21권2호
    • /
    • pp.209-217
    • /
    • 2018
  • The dynamic compressive behavior of concrete after freezing and thawing tests are investigated by using the split Hopkinson pressure bar (SHPB) technique. The stress-strain curves of concrete under dynamic loading are measured and analyzed. The setting numbers of freeze-thaw cycles are 0, 25, 50, and 75 cycles. Test results show that the dynamic strength decreases and peak strain increases with the increasing of freeze-thaw cycles. Based on the Weibull distribution model, statistical damage constitutive model for dynamic stress-strain response of concrete after freeze-thaw cycles was proposed. At last, the fragmentation test of concrete subjected to dynamic loading and freeze-thaw cycles is carried out using sieving statistics. The distributions of the fragment sizes are analyzed based on fractal theory. The fractal dimensions of concrete increase with the increasing of both freeze-thaw cycle and strain rate. The relations among the fractal dimension, strain rates and freeze-thawing cycles are developed.

스트럿-타이 모델에 의한 콘크리트 T형 교각 코핑부의 설계 (Design of RC T-type Pier Coping Using Strut-and-Tie Model)

  • 정광회;심별;송하원;변근주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.617-622
    • /
    • 2000
  • In this study, effective compressive strength and nodal zone of Strut-and-Tie Model are studied to propose a new design method for RC T-type pier coping for prevention of sudden brittle failure. The coping which transmits loads of bridge to pier should be properly designed to retain ductile behavior. In order to carry out this proper design using STM, tie must yield before concrete fails, and a stress at strut should not exceed a certain effective stress. Therefore, reasonable determination of the effective compressive strength of strut by considering stress states at the nodal zone exactly is very important. Since conventional STM is applied under assumption that all nodes are under hydrostatic stress state, actual non-hydrostatic stress state in nodal zone caused by geometrical characteristics, loading conditions, support conditions of structures can not be considered properly. In order to apply STM for design of RC T-type pier coping, the non-hydrostatic stress state of nodal zone is considered and effective compressive strength is proposed. Then, a new design method of RC T-type pier coping which applies the principle of superposition to obtain optimum ductile behavior is rationally designed.

  • PDF