• Title/Summary/Keyword: Compressive pressure

Search Result 608, Processing Time 0.032 seconds

FE Analyses of the Compressive Characteristics of Carbon Fabric/Polymeric Foam for Sandwich Structure (유한요소해석을 이용한 직조 탄소섬유 발포 고분자 샌드위치 구조의 압축특성)

  • Chang Seung Hwan;Cheon Seong Sik
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.194-197
    • /
    • 2004
  • In this paper, compressive characteristics of carbon fabric skin with polymeric foam core sandwich structure were investigated by FE analyses and compressive tests of polyurethane foam were also conducted with respect to temperature changes, which were determined by curing processes of epoxy or polyester resin to obtain mechanical behaviour of polyurethane foam. FE analyses indicated variation of parameters with respect to manufacturing pressure, which have comparatively massive effect upon mechanical properties of sandwich structures, i.e. wavelength as well as crimp angle of carbon fabric

  • PDF

Characterization of Piezoelectric Microspeaker Fabricated with C-axis Oriented ZnO Thin Film (C-축 배향된 ZnO 박막을 이용하여 제작한 압전형 마이크로 스피커의 특성 평가)

  • Yi Seung-Hwan;Seo Kyong-Won;Ryu Kum-Pyo;Kweon Soon-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.6
    • /
    • pp.531-537
    • /
    • 2006
  • A micromachined piezoelectric microspeaker was fabricated with a highly c-axis oriented ZnO thin film on a silicon-nitride film having compressive residual stress. When it was measured 3 mm away from the microspeaker in open field, the largest sound pressure level produced by the fabricated microspeaker was about 91 dB at around 2.9 kHz for the applied voltage of $6\;V_{peak-to-peak}$. The key technologies to these successful results were as follows: (1) the usage of a wrinkled diaphragm caused by the high compressive residual stress of silicon-nitride thin film, (2) the usage of the highly c-axis oriented ZnO thin film.

A data mining approach to compressive strength of CFRP-confined concrete cylinders

  • Mousavi, S.M.;Alavi, A.H.;Gandomi, A.H.;Esmaeili, M. Arab;Gandomi, M.
    • Structural Engineering and Mechanics
    • /
    • v.36 no.6
    • /
    • pp.759-783
    • /
    • 2010
  • In this paper, compressive strength of carbon fiber reinforced polymer (CFRP) confined concrete cylinders is formulated using a hybrid method coupling genetic programming (GP) and simulated annealing (SA), called GP/SA, and a robust variant of GP, namely multi expression programming (MEP). Straightforward GP/SA and MEP-based prediction equations are derived for the compressive strength of CFRP-wrapped concrete cylinders. The models are constructed using two sets of predictor variables. The first set comprises diameter of concrete cylinder, unconfined concrete strength, tensile strength of CFRP laminate, and total thickness of CFRP layer. The most widely used parameters of unconfined concrete strength and ultimate confinement pressure are included in the second set. The models are developed based on the experimental results obtained from the literature. To verify the applicability of the proposed models, they are employed to estimate the compressive strength of parts of test results that were not included in the modeling process. A sensitivity analysis is carried out to determine the contributions of the parameters affecting the compressive strength. For more verification, a parametric study is carried out and the trends of the results are confirmed via some previous studies. The GP/SA and MEP models are able to predict the ultimate compressive strength with an acceptable level of accuracy. The proposed models perform superior than several CFRP confinement models found in the literature. The derived models are particularly valuable for pre-design purposes.

A Study on the Vertical Bearing Capacity of Batter Piles Subjected to Vertical Load (연직하중을 받는 경사말뚝의 연직지지력에 관한 연구)

  • 성인출;이민희;최용규;권오균
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.49-55
    • /
    • 2003
  • In this study, based on the relationship of the vertical force - settlement of batter piles obtained by pressure chamber model tests, the vertical bearing capacity of vertical and batter piles according to the increase of pile inclination was analyzed. A model open - ended steel pipe pile with the inclination of 5$^\circ$, 10$^\circ$ and 15$^\circ$ was driven into saturated fine sand with relative density of 50 %, and the static compression load tests were performed under each confining pressure of 35, 70 and 120 kPa in pressure chamber. The vertical bearing capacity of pile obtained from pressure chamber tests increased with the pile inclination. In the case of the inclination of 5$^\circ$, 10$^\circ$, 15$^\circ$, increasing ratios of pile bearing capacity were 111, 121, 127 ~ 140 % of vertical bearing capacity respectively. In the case of the inclination of above 20$^\circ$, the model tests could not be performed because of pile of pile head during compressive loading on the pile head.

Response of Open-ended Pipe Pile Foundation at Offshore Sites to Seaquake Induced by the Vertical Seismic Excitation of the Seafloor (해저면의 수직 지진 진동에 의해 유발된 해진에 대한 해상 개단 강관 말뚝 기초의 거동)

  • 최용규;남문석
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.1
    • /
    • pp.11-21
    • /
    • 1998
  • During an earthquake, there are three main components of excitation : horizontal excitation of the ground, vertical excitation of the pile due to superstructure feedback produced by vertical excitation of the ground, and the seawater excitation induced by the vertical ground shaking, that is, "the seaquake." These excitations could have effects on the soil plugs in open-ended pie piles installed at offshore sites. In this study, seaquake excitation induced by the vertical ground shaking was simulated by pulsing the water pressure at the seabed. During a seaquake, due to the induced excess porewater pressure and pressure gradients in the soil, the capacity of open-ended pipe piles installed in a simulated sea depth of greate than 220 m was reduced serevely and the soil plugging resistance was degraded by more than 80% The soil plug was failed because of eh upward seepage forces that developed in the soil plug due to excess pore water pressure produced in the bottom of the soil plug during the seaquake, The compressive capacity of ar open-ended pile in a simulated sea depth of less than 220 m was reduced only by about 10% and the soil plug resistance was degraded by less than 5%.s than 5%.

  • PDF

Synthesis of Silica Aerogel at Ambient Pressure and Characterization (II) (실리카 에어로겔의 상압합성 및 특성연구(II))

  • 권영근;최세영;강신규
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.11
    • /
    • pp.1189-1197
    • /
    • 1999
  • Low-density silica gel monolith was synthesized at ambient pressure by surface modification with TMCS and sub-sequent heat treatment. The mechanical thermal and optical properties of gel were studied. Compressive strength and modulus of compression of 350$^{\circ}C$-heated gel with the density of 0.24g/cm3 were 250kPa and 0.2MPa respectively. The thermal conductivity of silica gels synthesized at ambient pressure exhibited 0.02 W/m$.$K for the density of 0.24g/cm3 which is similar to that of the gel via supercritical drying and their main thermal transfer mechanism is considered to be solid and radiation conduction at room temperature. Ambient-dried silica gels were transparent blue showing about 60% of transmittance in the wavelength of 1500-2100nm and typical absorption bands of existing bonds under heat treatment at 350$^{\circ}C$. Medium scale monolity(${\Phi}$=50mm) at ambient pressure could be successfully prepared through total 5-month process period.

  • PDF

To Study the Effect on Concrete Strength by Adding Waste Rubber Material from Worn Out Tires

  • Aleem, Muhammad;Ejaz, Naeem;Janjua, Nasir Sadiq;Gill, Tanveer;Sadiq, Muhammad Yasir
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.694-701
    • /
    • 2022
  • This paper introduces a study of concrete structures with a broken tire and a flat tire as a complete overhaul. The materials used to make concrete in this study are solid aggregate, cement, sand, flat tire, broken wheel, drinking water, and Ordinary Portland Cement. A total of 6 main compounds were thrown into solid cylinders and replaced by 0% as a controller followed by 5% and 10%. The cylinder pressure test of the concrete is done by applying the same pressure to the cylinders until a failure occurs. The results of the pressure test show that by applying 5% aggregation the pressure decreases. In Crumb wheel joints, the compression force decreases constantly as the percentage change increases. Therefore, the crumb wheel is not recommended for use as a complete replacement due to its compressive church power.

  • PDF

Effects of cement dosage and steel fiber ratio on the mechanical properties of reactive powder concrete

  • Erdogdu, Sakir;Kandil, Ufuk;Nayir, Safa
    • Advances in concrete construction
    • /
    • v.8 no.2
    • /
    • pp.139-144
    • /
    • 2019
  • In this study, the mechanical properties of reactive powder concrete (RPC) with a constant cement to silica fume ratio of 4 were investigated. In the experimental program, reactive powder concretes with steel fiber at different ratios were produced. Five productions using quartz sand with a maximum grain size of 0.6 mm were performed. A superplasticizer with a ratio of 3% of the cement was used for all productions. $40{\times}40{\times}160mm$ prismatic specimens were prepared and tested for flexural and compression. The specimens were exposed to two different curing conditions as autoclave and standard curing condition. Autoclave exposure was performed for 3 hours under a pressure of 2 MPa. It was observed that the compressive strength of concrete, along with the flexural strength exposed to autoclave was quite high compared to the strength of concretes subjected to standard curing. The results obtained indicated that the compressive strength, along with the flexural strength of autoclaved concrete increased as the amount of cement used increases. Approximately 15% increase in flexural strength was achieved with a 4% steel fiber addition. The maximum compressive strength that has been reached is over 210 MPa for reactive powder concrete for the same steel fiber ratio and with a cement content of $960kg/m^3$. The relationship between compressive strength and flexural strength of reactive powder concrete exposed to both curing conditions was also identified.

The Influence of Compressive Strength and Moisture Contents on Explosive Spalling of Concrete (압축강도 및 함수율이 콘크리트의 폭렬에 미치는 영향)

  • Kim, Dong-Joon;Han, Byung-Chan;Lee, Jae-Young;Harada, Kazunori;Kwon, Young-Jin
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.42-49
    • /
    • 2011
  • In the high temperature situation like in a fire, the high strength of concrete (HSC) has extreme danger named explosive spalling. It is assumed that the major cause of explosive spalling is water vapour pressure inside concrete. This paper examines the effect of the compressive strength and the moisture content on the initial occurrence of explosive spalling. For the effective experiment of the initial explosive spalling, the curve of ISO834 temperature profile is applied on the basis of 15 minute and 30 minute. As a result, the more increase the compressive strength and the moisture content, the more increase the occurrence and phenomenon of explosive spalling. This paper analyzes the territory of explosive spalling depending the compressive strength and the moisture content. The explosive spalling is not examined in the case of the compressive strength 50~100 MPa and the moisture content below 3% and the compressive strength over 100 MPa and the moisture content below 1%. Also, due to the HSC, which makes it more difficult to transport vapour and moisture, very high vapour-pressure may occur close to the surface, there is a greater risk that HSC spalls compared with normal strength concrete (NSC).

Compressive resistance behavior of UHPFRC encased steel composite stub column

  • Huang, Zhenyu;Huang, Xinxiong;Li, Weiwen;Zhang, Jiasheng
    • Steel and Composite Structures
    • /
    • v.37 no.2
    • /
    • pp.211-227
    • /
    • 2020
  • To explore the feasibility of eliminating the longitudinal rebars and stirrups by using ultra-high-performance fiber reinforcement concrete (UHPFRC) in concrete encased steel composite stub column, compressive behavior of UHPFRC encased steel stub column has been experimentally investigated. Effect of concrete types (normal strength concrete, high strength concrete and UHPFRC), fiber fractions, and transverse reinforcement ratio on failure mode, ductility behavior and axial compressive resistance of composite columns have been quantified through axial compression tests. The experimental results show that concrete encased composite columns with NSC and HSC exhibit concrete crushing and spalling failure, respectively, while composite columns using UHPFRC exhibit concrete spitting and no concrete spalling is observed after failure. The incorporation of steel fiber as micro reinforcement significantly improves the concrete toughness, restrains the crack propagation and thus avoids the concrete spalling. No evidence of local buckling of rebars or yielding of stirrups has been detected in composite columns using UHPFRC. Steel fibers improve the bond strength between the concrete and, rebars and core shaped steel which contribute to the improvement of confining pressure on concrete. Three prediction models in Eurocode 4, AISC 360 and JGJ 138 and a proposed toughness index (T.I.) are employed to evaluate the compressive resistance and post peak ductility of the composite columns. It is found that all these three models predict close the compressive resistance of UHPFRC encased composite columns with/without the transverse reinforcement. UHPFRC encased composite columns can achieve a comparable level of ductility with the reinforced concrete (RC) columns using normal strength concrete. In terms of compressive resistance behavior, the feasibility of UHPFRC encased steel composite stub columns with lesser longitudinal reinforcement and stirrups has been verified in this study.